Refine
Year of publication
- 2004 (286) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (76)
- Fachbereich Elektrotechnik und Informationstechnik (35)
- INB - Institut für Nano- und Biotechnologien (35)
- Fachbereich Energietechnik (31)
- Fachbereich Wirtschaftswissenschaften (31)
- IfB - Institut für Bioengineering (26)
- Fachbereich Maschinenbau und Mechatronik (23)
- Fachbereich Luft- und Raumfahrttechnik (21)
- Fachbereich Bauingenieurwesen (20)
- Fachbereich Chemie und Biotechnologie (15)
Has Fulltext
- no (286) (remove)
Document Type
- Article (207)
- Book (35)
- Conference Proceeding (25)
- Part of a Book (5)
- Doctoral Thesis (4)
- Patent (4)
- Other (2)
- Contribution to a Periodical (1)
- Diploma Thesis (1)
- Report (1)
Keywords
- avalanche (1)
IT Service Level Agreements
(2004)
This study has been performed to design the combination of the new ClearPET TM (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal Positron Emission Tomography (PET) system, with a microComputed Tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material.
Integrierte Oberflächendigitalisierung für die flexible Automatisierung bei kleinen Losgrößen
(2004)
Info-Web-Generation
(2004)
MultiChannel Photomultipliers (PM), like the R7600-00-M64 or R5900-00-M64 from Hamamatsu, are often chosen as photodetectors in high-resolution positron emission tomography (PET). A major problem of this PM is the nonuniform channel gain. In order to solve this problem, light attenuating masks were created. The aim of the masks is a homogenization of the output of all 64 channels using different hole sizes at the channel positions. The hole area, which is individually defined for the different channels, is inversely proportional to the channel gain. The measurements by inserting light attenuating masks improved a homogenization to a ratio of 1:1.2.
Geotechnik
(2004)
Farbanalyse von gebackenen oder frittierten Nahrungsmitteln und Vorhersage des Acrylamid-Wertes
(2004)