Article
Refine
Year of publication
Document Type
- Article (1578) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- CellDrum (3)
- Label-free detection (3)
- biosensors (3)
- hydrogen peroxide (3)
- shakedown analysis (3)
- Bacillus atrophaeus (2)
- Bauingenieurwesen (2)
- CAD (2)
- Capacitive field-effect sensor (2)
- Einspielanalyse (2)
- Empirical process (2)
- Field-effect sensor (2)
- Goodness-of-fit test (2)
- Independence test (2)
- Light-addressable potentiometric sensor (2)
- Lipopolysaccharide (2)
- Paired sample (2)
- Parametric bootstrap (2)
- Raman spectroscopy (2)
- Shakedown analysis (2)
- Stiffness (2)
- Traglastanalyse (2)
- capacitive field-effect sensors (2)
- carbonized rice husk (2)
- civil engineering (2)
- constructive alignment (2)
- damage (2)
- examination (2)
- field-effect sensor (2)
- frequency mixing magnetic detection (2)
- impedance spectroscopy (2)
- likelihood ratio test (2)
- limit analysis (2)
- locomotion (2)
- long-term retention (2)
- multimodal (2)
- muscle fascicle behavior (2)
- not identically distributed (2)
- practical learning (2)
- shakedown (2)
- tobacco mosaic virus (TMV) (2)
- ultrasound (2)
- ultrasound imaging (2)
- (Bio)degradation (1)
- Acceleration (1)
- Achilles tendon (1)
- Adaptive control (1)
- Afterload (1)
- Ageing (1)
- Air purification (1)
- AlterG (1)
- Alternating plasticity (1)
- Alzheimer's disease (1)
- Analysis (1)
- Analytischer Zulaessigkeitsnachweis (1)
- Anastomotic leakage (1)
- Anatomy (1)
- Annulus Fibrosus (1)
- Architectural design (1)
- Architectural gear ratio (1)
- Architektur (1)
- Arthosetherapie (1)
- Assistive technology (1)
- Asymptotic efficiency (1)
- Aufschlagversuch (1)
- Autolysis (1)
- Automatic control (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- Bacillus atrophaeus spores (1)
- Bacillus sp (1)
- Bacterial cellulose (1)
- Balance (1)
- Basis Reduktion (1)
- Basis reduction (1)
- Bicharakteristikenverfahren (1)
- Bioabsorbable (1)
- Biocomposites (1)
- Biomechanical simulation (1)
- Bioreaktor (1)
- Biosolubilization (1)
- Blutzellenlagerung (1)
- Bone quality and biomechanics (1)
- Booster Station (1)
- Bootstrap (1)
- Bootstrapping (1)
- Brownian Pillow (1)
- CNOT (1)
- Calorimetric gas sensor (1)
- Capacitive field-effect (1)
- Capacitive model (1)
- Carbon sources (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- Categorial variable (1)
- Cell permeability (1)
- Cellular force (1)
- Cellulose nanostructure (1)
- Cement infiltration (1)
- Cementoblast (1)
- Censored data (1)
- Chemical images (1)
- Chemical imaging sensor (1)
- Chemical sensor (1)
- Circular Dichroism (1)
- Clusterion (1)
- Co-managed care (1)
- Collective risk model (1)
- Competitiveness (1)
- Complex System (1)
- Complex-valued eigenvalues (1)
- Compliance (1)
- Compression (1)
- Computational biomechanics (1)
- Concomitant (1)
- Conductive Boundary Condition (1)
- Constitutive model (1)
- Contractile tension (1)
- Contractility (1)
- Convex optimization (1)
- Cost-effectiveness (1)
- Coverage probability (1)
- Cramér-von-Mises statistic (1)
- Cramér-von-Mises test (1)
- Cross border adjustment mechanism (1)
- Crámer–von-Mises distance (1)
- Culture media (1)
- C–V method (1)
- DNA biosensor (1)
- DNA hybridization (1)
- DPA (dipicolinic acid) (1)
- Damage mechanics theory (1)
- Decomposition (1)
- Deep Learning (1)
- Deformation (1)
- Dehydrogenase (1)
- Design-by-analysis (1)
- Diaphorase (1)
- Disc Degeneration (1)
- Discontinuous fractures (1)
- Discrete Optimization (1)
- Distorsion des oberen Sprunggelenks (1)
- Druckbeanspruchung (1)
- Druckbehälter (1)
- Druckbelastung (1)
- Druckgeräte (1)
- Drug simulation (1)
- E-Mobility (1)
- EIS capacitive sensor (1)
- ELISA (1)
- ES-FEM (1)
- Eigenvalue trajectories (1)
- Einspiel-Analyse (1)
- Einspiel-Kriterium (1)
- Einspielen (1)
- Elastizität (1)
- Elderly (1)
- Electrolyte–insulator–semiconductor (1)
- Electromagnetism (1)
- Electromechanical modeling (1)
- Elektroenzephalographie (1)
- Elemental (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Endothelial dysfunction (1)
- Energy-intensive industry (1)
- Enterprise information systems (1)
- Environmental impact (1)
- Enzymatic biosensor (1)
- Enzyme coverage (1)
- Enzyme logic gate (1)
- Enzyme-linked immunosorbent assay (1)
- Epithel (1)
- Equivalence test (1)
- Esophageal Doppler monitor (1)
- Experiment (1)
- External knee adduction moments (1)
- FS-FEM (1)
- Fall prevention (1)
- Fault approximation (1)
- Fault detection (1)
- Fehlerstellen (1)
- Fibroblast (1)
- Field effect (1)
- Field-effect biosensor (1)
- Finite element analysis (1)
- Finite element modelling (1)
- Fließgrenze (1)
- Floor prices (1)
- Force (1)
- Forces (1)
- Fracture configuration (1)
- Fracture simulation (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Frequency mixing magnetic detection (1)
- Functional Delta Method (1)
- Fußball (1)
- Gamma distribution (1)
- Geriatric (1)
- German (1)
- Glaucoma (1)
- Global and local collapse (1)
- Gold nanoparticles (1)
- Gonarthrose (1)
- Goodness-of-fit tests for uniformity (1)
- Grenzwertberechnung (1)
- Ground-level falls (1)
- Hadamard differentiability (1)
- Haemodialysis (1)
- Handbike (1)
- Harnleiter (1)
- Heart tissue culture (1)
- Hemoglobin structure (1)
- Heterostructure (1)
- Hip fractures (1)
- Hodgkin–Huxley models (1)
- Hoeffding-Blum-Kiefer-Rosenblatt independence test (1)
- Homogenization (1)
- Hotelling’s T² test (1)
- Human-Computer interaction (1)
- Hydrogen peroxide (1)
- Hämoglobin (1)
- Hämoglobinstruktur (1)
- Image Reconstruction (1)
- Impedance spectroscopy (1)
- Incomplete data (1)
- Induced pluripotent stem cells (1)
- Information extraction (1)
- Inotropic compounds (1)
- Integrated empirical distribution (survival) function (1)
- Interior transmission problem (1)
- Intervertebral Disc (1)
- Intradiscal Pressure (1)
- Inverse Scattering (1)
- Inverse dynamic problem (1)
- Inverse kinematic problem (1)
- Inverse scattering problem (1)
- Ion channels (1)
- Iterative learning control (1)
- Kinetic energy (1)
- Kniegelenkarthrose (1)
- Knochen (1)
- Knochenbildung (1)
- Knochenchirugie (1)
- Knochendichte (1)
- Kohlenstofffaser (1)
- LPS (1)
- Lab-on-Chip (1)
- Langevin theory (1)
- Layer-by-layer adsorption (1)
- LbL films (1)
- Light-addressable Potentiometric Sensor (1)
- Limit analysis (1)
- Liver (1)
- Long COVID (1)
- Luftreiniger (1)
- MBST (1)
- MCDA (1)
- MOS (1)
- Machine learning (1)
- Magnetic nanoparticles (1)
- Manipulated variables (1)
- Marginal homogeneity test (1)
- Materialermüdung (1)
- Mechanotransduction (1)
- Medusomyces gisevi (1)
- Metascintillator (1)
- Microcirculation (1)
- Micromagnetic simulation (1)
- Mild cognitive impairment (1)
- Mobility (1)
- Mobility tests (1)
- Mobility transition (1)
- Model-driven software engineering (1)
- Multi-criteria decision analysis (1)
- Multi-sample problem (1)
- Multianalyte detection (1)
- Multicell (1)
- Multiple TOF kernels (1)
- Multiplexing (1)
- Muscle (1)
- Muscle Fascicle (1)
- Muscle Force (1)
- Musculoskeletal model (1)
- Musculoskeletal system (1)
- Myocardial infarction and cardiac death (1)
- NONOate (1)
- Natural fibres (1)
- Negative impedance convertor (1)
- Neural Network (1)
- Nitric Oxide (1)
- Nitric Oxide Donor (1)
- Non-parallel fissures (1)
- Nonequilibrium dynamics (1)
- Nonlinear Dynamics (1)
- Nucleus Pulposus (1)
- Numerical inversion of Laplace transforms (1)
- Numerical linear algebra (1)
- O2 plasma (1)
- Ocular blood flow (1)
- Organic light-emitting diode display (1)
- Organkultur (1)
- Osteoporose (1)
- Osteoporosis (1)
- Paralympic sport (1)
- Penicillin (1)
- Permeability (1)
- Permeabilität (1)
- Peroxidase (1)
- Pflanzenphysiologie (1)
- Pflanzenscanner (1)
- Pflanzenstress (1)
- Pharmacology (1)
- Physiology (1)
- Plant virus (1)
- Plasmacluster ion technology (1)
- Plastizität (1)
- Poly(allylamine hydrochloride) (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Polylactide acid (1)
- Polymer-matrix composites (1)
- Post-COVID-19 syndrome (1)
- Preference assessment (1)
- Pressure loaded crack-face (1)
- Prevention (1)
- Product-integration (1)
- Progressive plastic deformation (1)
- Prophylaxis (1)
- Proximal humerus fracture (1)
- Psychiatrische Biomarker (1)
- Pulsations (1)
- Pump System (1)
- RVA (1)
- Ratchetting (1)
- Raumluft (1)
- Real-time monitoring (1)
- Recombinant activated protein C (1)
- Red blood cell storage (1)
- Regionalization (1)
- Rehabilitation Technology and Prosthetics (1)
- Rehabilitation engineering (1)
- Resampling test (1)
- Resistive temperature detector (1)
- Resolvent Operator (1)
- Resonance-mode measurement (1)
- Retinal vessel analysis (1)
- Retinal vessels (1)
- Robotic rehabilitation (1)
- Rohr (1)
- Rohrbruch (1)
- Rotator cuff (1)
- Running (1)
- S-FEM (1)
- ScaLAPACK (1)
- Schienbeinschoner (1)
- Schlafspindeldetektion (1)
- Schwammknochen (1)
- Semi-parametric random censorship model (1)
- Septic cardiomyopathy (1)
- Shakedown (1)
- Shakedown criterion (1)
- Silk fibroin (1)
- Simulation (1)
- Simultaneous determination (1)
- Skeletal muscle (1)
- Small Aral Sea (1)
- Sn₃O₄ (1)
- Software and systems modeling (1)
- Spleen (1)
- Sprunggelenkorthesen (1)
- Stahl (1)
- Steel industry (1)
- Sterilisation process (1)
- Stress concentrations (1)
- Strukturanalyse (1)
- SunRav BookEditor (1)
- Surgical Navigation and Robotics (1)
- Surgical staplers (1)
- Survival analysis (1)
- TMV adsorption (1)
- TOF PET (1)
- Ta₂O₅ gate (1)
- Technical Operations Research (TOR) (1)
- Temperaturabhängigkeit (1)
- Tendon Rupture (1)
- Tendon properties (1)
- Tendons (1)
- Tension (1)
- Tinetti test (1)
- Tissue Engineering (1)
- Tobacco mosaic virus (TMV) (1)
- Traglast (1)
- Transmission Eigenvalues (1)
- Ultrasound (1)
- Uniaxial compression test (1)
- Vapnik–Čhervonenkis class (1)
- Variable height stapler design (1)
- Vascular response (1)
- Vasomotions (1)
- Velocity (1)
- Vertebroplastie (1)
- Vertebroplasty (1)
- Viscous flow (1)
- Viskose Strömung (1)
- Viskosität (1)
- Visual field asymmetry (1)
- Volterra integral equation (1)
- Volume of confidence regions (1)
- Volume status (1)
- Wolff's Law (1)
- Wolffsches Gesetz (1)
- Wundheilung (1)
- XOR (1)
- Zeta potential (1)
- Zug-Druck Belastung (1)
- acetoin (1)
- acetoin reductase (1)
- achilles tendon (1)
- actin cytoskeleton (1)
- adipose-derived stromal cells (ASCs) (1)
- adsorption (1)
- agility (1)
- alcoholic beverages (1)
- allocation (1)
- alternierend Verformbarkeit (1)
- amperometric biosensors (1)
- anaesthetic complications (1)
- anisotropy (1)
- ankle braces (1)
- ankle sprain (1)
- annealing (1)
- aortic perfusion (1)
- architecture (1)
- aromatic amines (1)
- arthrosis therapy (1)
- artificial olfactory image (1)
- asymptotic relative efficiency (1)
- atomic layer deposition (1)
- barium strontium titanate (1)
- biaxial tensile experiment (1)
- bicharacteristics (1)
- bioburdens (1)
- biocompatible (1)
- biocompatible materials (1)
- biodegradabl (1)
- biodegradable electronic devices (1)
- biomechanics (1)
- biopotential electrodes (1)
- biosensor (1)
- bone density (1)
- bone structure (1)
- bootstrap (1)
- burst pressure (1)
- burst tests (1)
- calorimetric gas sensor (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- cancellous bone (1)
- capacitive electrolyte–insulator–semiconductor sensors (1)
- capacitive field-effect sensor (1)
- carbon electrodes (1)
- cardiomyocyte biomechanics (1)
- catalytic metal (1)
- cell aerosolization (1)
- cell atomization (1)
- central symmetry test (1)
- cerebral small vessel disease (1)
- chance constrained programming (1)
- chemical sensor (1)
- cognitive impairment (1)
- community dwelling (1)
- complete block symmetry (1)
- computational fluid dynamics analysis (1)
- conditional excess distribution (1)
- conditional expectation principle (1)
- confidence interval (1)
- connective tissue (1)
- constitutive modeling (1)
- contactless conductivity sensor (1)
- correlation (1)
- coupled Néel–Brownian relaxation dynamics (1)
- covariance principle (1)
- dental trauma (1)
- dialysis (1)
- difficult airway (1)
- direct method (1)
- distance learning (1)
- distorted element (1)
- double-lumen tube intubation (1)
- drop jump (1)
- e-books (1)
- e-issues (1)
- ecological structure (1)
- eigensolvers (1)
- elastic solids (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- electromyography (1)
- electronic nose (1)
- encapsulation materials (1)
- endoluminal (1)
- endospores (1)
- energy absorption (1)
- energy dissipation (1)
- enzymatic (bio)degradation (1)
- enzymatic biosensor (1)
- enzyme cascade (1)
- epithelization (1)
- exchangeability test (1)
- extracorporeal membrane oxygenation (1)
- fatigue analyses (1)
- fibroin (1)
- fibulare Bandruptur (1)
- field-effect structure (1)
- flaw (1)
- force generation (1)
- forecast (1)
- forehead EEG (1)
- fortschreitende plastische Deformation (1)
- frequency mixing (1)
- functional data (1)
- gait (1)
- gas sensor (1)
- glucose (1)
- glucose oxidase (GOx) (1)
- gonarthrosis (1)
- goodness-of-fit test (1)
- graphene oxide (1)
- healthy aging (1)
- heavy metals (1)
- hiPS cardiomyocytes (1)
- high-intensity exercise (1)
- high-k material (1)
- horseradish peroxidase (HRP) (1)
- huge dimensional data (1)
- human dermal fibroblasts (1)
- humic acid (1)
- hydroxylation (1)
- hyper-gravity (1)
- hyperelastic (1)
- hypo-gravity (1)
- immobilization (1)
- in-ear EEG (1)
- in-situ monitoring (1)
- independence test (1)
- intraclass correlation coefficient (1)
- key performance indicators (1)
- konvexe Optimierung (1)
- lable-free detection (1)
- large language models (1)
- layer-by-layer technique (1)
- light-addressable potentiometric sensor (1)
- light-addressing technologies (1)
- lignite (1)
- limit load (1)
- lipopolysaccharide (1)
- lipopolysaccharides (1)
- load limit (1)
- magnetic actuation (1)
- magnetic beads (1)
- magnetic biosensing (1)
- magnetic nanoparticles (1)
- magnetic relaxation (1)
- magnetic sandwich immunoassay (1)
- magnetic sensing (1)
- magnetic separation (1)
- magnetic tweezers (1)
- magnetophoretic velocity (1)
- mechanical buffer (1)
- metagenomics (1)
- metal-oxide-semiconductor structure (1)
- microbial diversity (1)
- micromagnetic simulation (1)
- multi-functional material (1)
- multinomial distribution (1)
- multiparametric immunoassays (1)
- multivariate normal distribution (1)
- muscle mechanics (1)
- nanobelts (1)
- nanomaterials (1)
- nanostructured carbonized plant parts (1)
- nanostrukturierte carbonisierte Pflanzenteile (1)
- naphtols (1)
- non-simplex S-FEM elements (1)
- novel photoexcitation method (1)
- optical sensor setup (1)
- optical spore trapping (1)
- optical trapping (1)
- organosilanes (1)
- overload (1)
- pH sensors (1)
- parabolic flight (1)
- penicillin (1)
- penicillinase (1)
- performance analysis (1)
- performance testing (1)
- phenols (1)
- photoelectrochemistry (1)
- physiology (1)
- pipes (1)
- plant scanner (1)
- plant stress (1)
- plant virus detection (1)
- plug-based microfluidic device (1)
- poly(d, l-lactic acid) (1)
- polyaniline (1)
- portfolio risk (1)
- prevention (1)
- psychosocial (1)
- random effects (1)
- random effects meta-regression model (1)
- ratchetting (1)
- rehabilitation (1)
- reliability analysis (1)
- reliability of structures (1)
- retinal microvasculature (1)
- retinal vessels (1)
- running (1)
- rupture of the fibular ligament (1)
- sEMG (1)
- sarcomere operating length (1)
- scanned light pulse technique (1)
- semantic role labeling (1)
- separable Hilbert space (1)
- series elastic element behavior (1)
- shakedown analyses (1)
- shotgun sequencing (1)
- shoulder (1)
- silanization (1)
- simulation (1)
- smooth muscle contraction (1)
- softs (1)
- spatial resolution (1)
- speaker attribution (1)
- sprint start (1)
- standard error of measurement (1)
- sterilisation (1)
- sterility tests (1)
- sterilization (1)
- sterilization conditions (1)
- sterilization efficacy (1)
- sterilization methods (1)
- stiffness (1)
- stochastic programming (1)
- strain energy function (1)
- stretch reflex (1)
- stretch-shortening cycle (1)
- superparamagnetic bead (1)
- superparamagnetic nanoparticles (1)
- surface functionalization (1)
- surface modification (1)
- survival (1)
- temperature (1)
- tendon rupture (1)
- tension–torsion loading (1)
- test-retest reliability (1)
- thermal ratcheting (1)
- tilted constant illumination (1)
- titanium dioxide photoanode (1)
- tri-lineage differentiation (1)
- turnip vein clearing virus (TVCV) (1)
- twin-fluid atomizer (1)
- ultrasonography (1)
- ultrathin gate insulators (1)
- uniformly most powerful invariant test (1)
- unloading (1)
- validation methods (1)
- vessels (1)
- videolaryngoscopy (1)
- virgin passive (1)
- viscoelasticity (1)
- visualization (1)
- walking (1)
- walking gait (1)
- wound healing (1)
- yield stress (1)
- · Psychiatrische Erkrankungen/Diagnostik (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (1578) (remove)
One-chip integrated dual amperometric/field-effect sensor for the detection of dissolved hydrogen
(2011)
Objective
To investigate whether functional brain networks of epilepsy patients treated with antiepileptic medication differ from networks of healthy controls even during the seizure-free interval.
Methods
We applied different rules to construct binary and weighted networks from EEG and MEG data recorded under a resting-state eyes-open and eyes-closed condition from 21 epilepsy patients and 23 healthy controls. The average shortest path length and the clustering coefficient served as global statistical network characteristics.
Results
Independent on the behavioral condition, epileptic brains exhibited a more regular functional network structure. Similarly, the eyes-closed condition was characterized by a more regular functional network structure in both groups. The amount of network reorganization due to behavioral state changes was similar in both groups. Consistent findings could be achieved for networks derived from EEG but hardly from MEG recordings, and network construction rules had a rather strong impact on our findings.
Conclusions
Despite the locality of the investigated processes epileptic brain networks differ in their global characteristics from non-epileptic brain networks. Further methodological developments are necessary to improve the characterization of disturbed and normal functional networks.
Significance
An increased regularity and a diminished modulation capability appear characteristic of epileptic brain networks.
Background
Osteoporosis is associated with the risk of fractures near the hip. Age and comorbidities increase the perioperative risk. Due to the ageing population, fracture of the proximal femur also proves to be a socio-economic problem. Preventive surgical measures have hardly been used so far.
Methods
10 pairs of human femora from fresh cadavers were divided into control and low-volume femoroplasty groups and subjected to a Hayes fall-loading fracture test. The results of the respective localization and classification of the fracture site, the Singh index determined by computed tomography (CT) examination and the parameters in terms of fracture force, work to fracture and stiffness were evaluated statistically and with the finite element method. In addition, a finite element parametric study with different position angles and variants of the tubular geometry of the femoroplasty was performed.
Findings
Compared to the control group, the work to fracture could be increased by 33.2%. The fracture force increased by 19.9%. The used technique and instrumentation proved to be standardized and reproducible with an average poly(methyl methacrylate) volume of 10.5 ml. The parametric study showed the best results for the selected angle and geometry.
Interpretation
The cadaver studies demonstrated the biomechanical efficacy of the low-volume tubular femoroplasty. The numerical calculations confirmed the optimal choice of positioning as well as the inner and outer diameter of the tube in this setting. The standardized minimally invasive technique with the instruments developed for it could be used in further comparative studies to confirm the measured biomechanical results.
The porosity of surgical meshes makes them flexible for large elastic deformation and establishes the healing conditions of good tissue in growth. The biomechanic modeling of orthotropic and compressible materials requires new materials models and simulstaneoaus fit of deformation in the load direction as well as trannsversely to to load. This nonlinear modeling can be achieved by an optical deformation measurement. At the same time the full field deformation measurement allows the dermination of the change of porosity with deformation. Also the socalled effective porosity, which has been defined to asses the tisssue interatcion with the mesh implants, can be determined from the global deformation of the surgical meshes.
An enzyme-based reversible Controlled NOT (CNOT) logic gate operating on a semiconductor transducer
(2017)
An enzyme-based biocatalytic system mimicking operation of a logically reversible Controlled NOT (CNOT) gate has been interfaced with semiconductor electronic transducers. Electrolyte–insulator–semiconductor (EIS) structures have been used to transduce chemical changes produced by the enzyme system to an electronically readable capacitive output signal using field-effect features of the EIS device. Two enzymes, urease and esterase, were immobilized on the insulating interface of EIS structure producing local pH changes performing XOR logic operation controlled by various combinations of the input signals represented by urea and ethyl butyrate. Another EIS transducer was functionalized with esterase only, thus performing Identity (ID) logic operation for the ethyl butyrate input. Both semiconductor devices assembled in parallel operated as a logically reversible CNOT gate. The present system, despite its simplicity, demonstrated for the first time logically reversible function of the enzyme system transduced electronically with the semiconductor devices. The biomolecular realization of a CNOT gate interfaced with semiconductors is promising for integration into complex biomolecular networks and future biosensor/biomedical applications.
A graphene-functionalized carbon fiber electrode was modified with adsorbed polyethylenimine to introduce amino functionalities and then with trigonelline and 4-carboxyphenylboronic acid covalently bound to the amino groups. The trigonelline species containing quarterized pyridine groups produced positive charge on the electrode surface regardless of the pH value, while the phenylboronic acid species were neutral below pH 8 and negatively charged above pH 9 (note that their pKa=8.4). The total charge on the monolayer-modified electrode was positive at the neutral pH and negative at pH > 9. Note that 4-carboxyphenylboronic acid was attached to the electrode surface in molar excess to trigonelline, thus allowing the negative charge to dominate on the electrode surface at basic pH. Negatively charged fluorescent dye-labeled insulin (insulin-FITC) was loaded on the modified electrode surface at pH 7.0 due to its electrostatic attraction to the positively charged interface. The local pH in close vicinity to the electrode surface was increased to ca. 9–10 due to consumption of H+ ions upon electrochemical reduction of oxygen proceeding at the potential of −1.0 V (vs. Ag/AgCl) applied on the modified electrode. The process resulted in recharging of the electrode surface to the negative value due to the formation of the negative charge on the phenylboronic acid groups, thus resulting in the electrostatic repulsion of insulin-FITC and stimulating its release from the electrode surface. The insulin release was characterized by fluorescence spectroscopy (using the FITC-labeled insulin), by electrochemical measurements on an iridium oxide, IrOx, electrode and by mass spectrometry. The graphene-functionalized carbon fiber electrode demonstrated significant advantages in the signal-stimulated insulin release comparing with the carbon fiber electrode without the graphene species.
A novel scheme for precise diagnostics and effective stabilization of currents in a fuel cell stack
(2010)
Farbanalyse von gebackenen oder frittierten Nahrungsmitteln und Vorhersage des Acrylamid-Wertes
(2004)
Bildrestauration in der digitalen Radiographie mit Hilfe parallel arbeitender Signalprozessoren
(1998)
Scale braking in inclusive charged particle production by e--e+ annihilation. TASSO Collaboration
(1982)
K0 production in e+e− annihilations at 30 GeV center of mass energy. TASSO Collaboration
(1980)
Test of QED in e+e− annihilation at energies between 12 and 31.6 GeV. TASSO Collaboration
(1980)
π0 production by e+e− annihilation at 14 and 34 GeV c.m. energy . TASSO Collaboration
(1982)
Λ, Image production in e+e- annihilation at 33 GeV centre of mass energy. TASSO Collaboration
(1981)
Search for new sequential leptons in e+e- annihilation at petra energies. TASSO Collaboration
(1981)
Following the success of PET/CT during the last decade and the recent increasing proliferation of SPECT/CT, another hybrid imaging instrument has been gaining more and more interest: MR-PET. First combined, simultaneous PET and MR studies carried out in small animals demonstrated the feasibility of the new approach. Concurrently, some prototypes of an MR-PET scanner for simultaneous human brain studies have been built, their performance is being tested and preliminary applications have already been shown. Through this pioneering work, it has become clear that advances in the detector design are necessary for further optimization.
Recently, the different issues related to the present state and future prospects of MR-PET were presented and discussed during an international 2-day workshop at the Forschungszentrum Jülich, Germany, held after, and in conjunction with, the 2008 IEEE Nuclear Science Symposium and Medical Imaging Conference in Dresden, Germany on October 27–28, 2008. The topics ranged from small animal MR-PET imaging to human MR-BrainPET imaging, new detector developments, challenges/opportunities for ultra-high field MR-PET imaging and considerations of possible future research and clinical applications. This report presents a critical summary of the contributions made to the workshop.
Exposure to prolonged periods in microgravity is associated with deconditioning of the musculoskeletal system due to chronic changes in mechanical stimulation. Given astronauts will operate on the Lunar surface for extended periods of time, it is critical to quantify both external (e.g., ground reaction forces) and internal (e.g., joint reaction forces) loads of relevant movements performed during Lunar missions. Such knowledge is key to predict musculoskeletal deconditioning and determine appropriate exercise countermeasures associated with extended exposure to hypogravity.
We present a sensor concept based on copper(II)oxide (CuO) nanofibres for the detection of hydrogen peroxide (H2O2) vapour in the percent per volume (% v/v) range. The fibres were produced by using the electrospinning technique. To avoid water condensation in the pores, the fibres were initially modified by an exposure to H2S to get an enclosed surface. By a thermal treatment at 350 °C the fibres were oxidised back to CuO. Thereby, the visible pores disappear which was verified by SEM analysis. The fibres show a decrease of resistance with increasing H2O2 concentration which is due to the fact that hydrogen peroxide is an oxidising gas and CuO a p-type semiconductor. The sensor shows a change of resistance within the minute range to the exposure until the maximum concentration of 6.9% v/v H2O2. At operating temperatures below 450 °C the corresponding sensor response to a concentration of 4.1% v/v increases. The sensor shows a good reproducibility of the signal at different measurements. CuO seems to be a suitable candidate for the detection of H2O2 vapour at high concentrations.
Resistance behaviour of the sensor under exposure to H2O2 vapours between 2.3 and 6.9% v/v at an operating temperature of 450 °C.
Differential modulation of valence and arousal in high-alexithymic and low-alexithymic individuals
(2010)
High-alexithymic individuals are characterized by an impaired ability to identify and communicate emotions whereas low-alexithymic individuals have a wide-ranging ability to deal with emotions. This study examined the hypothesis that valence and arousal modifications of emotional stimuli differentially modulate cortical regions in high-alexithymic and low-alexithymic individuals. To this end, 28 high-alexithymic and 25 low-alexithymic individuals were investigated with event-related fMRI using visual emotional stimuli. We found differential neural activations in the dorsal anterior cingulate, the insula and the amygdala. We suggest that these differences may account for the impaired ability of high-alexithymic individuals to appropriately handle emotional stimuli.
Background: One of the most prominent neurobiological models of alexithymia assumes an altered function of the anterior cingulate cortex (ACC) as the crucial neural correlate of alexithymia. So far functional imaging studies have yielded inconclusive results. Therefore, we tested this hypothesis in healthy alexithymics and nonalexithymics in an event-related fMRI study.
Methods: Thirty high- and 30 low-alexithymic right-handed male subjects (selected by the 20-item Toronto Alexithymia Scale, TAS-20) were investigated with event-related fMRI using a picture viewing paradigm. The stimuli consisted of happy, fearful and neutral facial expressions (Ekman-Friesen) as well as positive, negative and neutral pictures from the International Affective Picture System.
Results: Contrasting the high-alexithymic with the low-alexithymic group we observed increased activation of the supragenual ACC for different emotional valences as well as for different emotional stimuli. Moreover, there was a positive correlation of the ACC with the individual TAS-20 scores but no correlations with the individual Beck Depression Inventory scores. Additionally, there was no difference in activity of the amygdala.
Conclusions: We demonstrated that the supragenual ACC is constantly activated more strongly in alexithymic subjects and that this activation is related to the symptoms of alexithymia and not to associated symptoms such as depression. Therefore, our findings support the hypothesis of an altered function of the ACC in alexithymia.
Within the Crystal Clear Collaboration (CCC), four centers are developing second generation high performance small animal positron emission tomography (PET) scanners for different kinds of animals and medical applications. The first prototypes are photomultiplier tube (PMT)-based systems including depth of interaction (DOI) detection by using a phoswich layer of lutetium oxyorthosilicate (LSO) and lutetium yttrium aluminum perovskite (LuYAP). The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in fields of view (FOVs) caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN, Geneva, Switzerland) was used.
The optimization of light output and energy resolution of scintillators is of special interest for the development of high resolution and high sensitivity PET. The aim of this work is to obtain statistically reliable results concerning optimal surface treatment of scintillation crystals and the selection of reflector material. For this purpose, raw, mechanically polished and etched LSO crystals (size 2×2×10 mm3) were combined with various reflector materials (Teflon tape, Teflon matrix, BaSO4) and exposed to a 22Na source. In order to ensure the statistical reliability of the results, groups of 10 LSO crystals each were measured for all combinations of surface treatment and reflector material. Using no reflector material the light output increased up to 551±35% by mechanical polishing the surface compared to 100±5% for raw crystals. Etching the surface increased the light output to 441±29%. The untreated crystals had an energy resolution of 24.6±4.0%. By mechanical polishing the surface it was possible to achieve an energy resolution of 13.2±0.8%, by etching of 14.8±0.7%. In combination with BaSO4 as reflector material the maximum increase of light output has been established to 932±57% for mechanically polished and 895±61% for etched crystals. The combination with BaSO4 also caused the best improvement of the energy resolution up to 11.6±0.2% for mechanically polished and 12.2±0.3% for etched crystals. Relating to the light output there was no significant statistical difference between the two surface treatments in combination with BaSO4. In contrast to this, the statistical results of the energy resolution have shown the combination of mechanical polishing and BaSO4 as the optimum.
BACKGROUND: Muscle stretch reflexes are widely considered to beneficially influence joint stability and power generation in the lower limbs. While in the upper limbs and especially in the muscles surrounding the shoulder joint such evidence is lacking. OBJECTIVE: To quantify the electromyographical response in the muscles crossing the shoulder of specifically trained overhead athletes to an anterior perturbation force. METHODS: Twenty healthy male participants performed six sets of different external shoulder rotation stretches on an isokinetic dynamometer over a range of amplitudes and muscle pre-activation moment levels. All stretches were applied with a dynamometer acceleration of 10,000∘/s2 and a velocity of 150∘/s. Electromyographical response was measured via sEMG. RESULTS: Consistent reflexes were not observed in all experimental conditions. The reflex latencies revealed a significant muscle main effect (F (2,228) = 99.31, p< 0.001; η2= 0.466; f= 0.934) and a pre-activation main effect (F (1,228) = 142.21, p< 0.001; η2= 0.384; f= 1.418). The stretch reflex amplitude yielded a significant pre-activation main effect (F (1,222) = 470.373, p< 0.001; η2= 0.679; f= 1.454). CONCLUSION: Short latency muscle reflexes showed a tendency to an anterior to posterior muscle recruitment whereby the main internal rotator muscles of the shoulder revealed the most consistent results.
BACKGROUND: Muscle stretch reflexes are widely used to examine neural muscle function. The knowledge of reflex response in muscles crossing the shoulder is limited. OBJECTIVE: To quantify reflex modulation according to various subject postures and different procedures of muscle pre-activation steering. METHODS: Thirteen healthy male participants performed two sets of external shoulder rotation stretches in various positions and with different procedures of muscle pre-activation steering on an isokinetic dynamometer over a range of two different pre-activation levels. All stretches were applied with a dynamometer acceleration of 104∘/s2 and a velocity of 150∘/s. Electromyographical response was measured via sEMG. RESULTS: Consistent reflexive response was observed in all tested muscles in all experimental conditions. The reflex elicitation rate revealed a significant muscle main effect (F (5,288) = 2.358, ρ= 0.040; η2= 0.039; f= 0.637) and a significant test condition main effect (F (1,288) = 5.884, ρ= 0.016; η2= 0.020; f= 0.143). Reflex latency revealed a significant muscle pre-activation level main effect (F (1,274) = 5.008, ρ= 0.026; η2= 0.018; f= 0.469). CONCLUSION: Muscular reflexive response was more consistent in the primary internal rotators of the shoulder. Supine posture in combination with visual feedback of muscle pre-activation level enhanced the reflex elicitation rate.
Test-retest reliability of the internal shoulder rotator muscles' stretch reflex in healthy men
(2021)
Until now the reproducibility of the short latency stretch reflex of the internal rotator muscles of the glenohumeral joint has not been identified. Twenty-three healthy male participants performed three sets of external shoulder rotation stretches with various pre-activation levels on two different dates of measurement to assess test-retest reliability. All stretches were applied with a dynamometer acceleration of 104°/s2 and a velocity of 150°/s. Electromyographical response was measured via surface EMG. Reflex latencies showed a pre-activation effect (ƞ2 = 0,355). ICC ranged from 0,735 to 0,909 indicating an overall “good” relative reliability. SRD 95% lay between ±7,0 to ±12,3 ms.. The reflex gain showed overall poor test-retest reproducibility. The chosen methodological approach presented a suitable test protocol for shoulder muscles stretch reflex latency evaluation. A proof-of-concept study to validate the presented methodical approach in shoulder involvement including subjects with clinically relevant conditions is recommended.
It has been shown that muscle fascicle curvature increases with increasing contraction level and decreasing muscle–tendon complex length. The analyses were done with limited examination windows concerning contraction level, muscle–tendon complex length, and/or intramuscular position of ultrasound imaging. With this study we aimed to investigate the correlation between fascicle arching and contraction, muscle–tendon complex length and their associated architectural parameters in gastrocnemius muscles to develop hypotheses concerning the fundamental mechanism of fascicle curving. Twelve participants were tested in five different positions (90°/105°*, 90°/90°*, 135°/90°*, 170°/90°*, and 170°/75°*; *knee/ankle angle). They performed isometric contractions at four different contraction levels (5%, 25%, 50%, and 75% of maximum voluntary contraction) in each position. Panoramic ultrasound images of gastrocnemius muscles were collected at rest and during constant contraction. Aponeuroses and fascicles were tracked in all ultrasound images and the parameters fascicle curvature, muscle–tendon complex strain, contraction level, pennation angle, fascicle length, fascicle strain, intramuscular position, sex and age group were analyzed by linear mixed effect models. Mean fascicle curvature of the medial gastrocnemius increased with contraction level (+5 m−1 from 0% to 100%; p = 0.006). Muscle–tendon complex length had no significant impact on mean fascicle curvature. Mean pennation angle (2.2 m−1 per 10°; p < 0.001), inverse mean fascicle length (20 m−1 per cm−1; p = 0.003), and mean fascicle strain (−0.07 m−1 per +10%; p = 0.004) correlated with mean fascicle curvature. Evidence has also been found for intermuscular, intramuscular, and sex-specific intramuscular differences of fascicle curving. Pennation angle and the inverse fascicle length show the highest predictive capacities for fascicle curving. Due to the strong correlations between pennation angle and fascicle curvature and the intramuscular pattern of curving we suggest for future studies to examine correlations between fascicle curvature and intramuscular fluid pressure.
We consider a binary multivariate regression model where the conditional expectation of a binary variable given a higher-dimensional input variable belongs to a parametric family. Based on this, we introduce a model-based bootstrap (MBB) for higher-dimensional input variables. This test can be used to check whether a sequence of independent and identically distributed observations belongs to such a parametric family. The approach is based on the empirical residual process introduced by Stute (Ann Statist 25:613–641, 1997). In contrast to Stute and Zhu’s approach (2002) Stute & Zhu (Scandinavian J Statist 29:535–545, 2002), a transformation is not required. Thus, any problems associated with non-parametric regression estimation are avoided. As a result, the MBB method is much easier for users to implement. To illustrate the power of the MBB based tests, a small simulation study is performed. Compared to the approach of Stute & Zhu (Scandinavian J Statist 29:535–545, 2002), the simulations indicate a slightly improved power of the MBB based method. Finally, both methods are applied to a real data set.
Determination of the frictional coefficient of the implant-antler interface : experimental approach
(2012)
The similar bone structure of reindeer antler to human bone permits studying the osseointegration of dental implants in the jawbone. As the friction is one of the major factors that have a significant influence on the initial stability of immediately loaded dental implants, it is essential to define the frictional coefficient of the implant-antler interface. In this study, the kinetic frictional forces at the implant-antler interface were measured experimentally using an optomechanical setup and a stepping motor controller under different axial loads and sliding velocities. The corresponding mean values of the static and kinetic frictional coefficients were within the range of 0.5–0.7 and 0.3–0.5, respectively. An increase in the frictional forces with increasing applied axial loads was registered. The measurements showed an evidence of a decrease in the magnitude of the frictional coefficient with increasing sliding velocity. The results of this study provide a considerable assessment to clarify the suitable frictional coefficient to be used in the finite element contact analysis of antler specimens.
Background
For supratentorial craniotomy, surgical access, and closure technique, including placement of subgaleal drains, may vary considerably. The influence of surgical nuances on postoperative complications such as cerebrospinal fluid leakage or impaired wound healing overall remains largely unclear. With this study, we are reporting our experiences and the impact of our clinical routines on outcome in a prospectively collected data set.
Method
We prospectively observed 150 consecutive patients undergoing supratentorial craniotomy and recorded technical variables (type/length of incision, size of craniotomy, technique of dural and skin closure, type of dressing, and placement of subgaleal drains). Outcome variables (subgaleal hematoma/CSF collection, periorbital edema, impairment of wound healing, infection, and need for operative revision) were recorded at time of discharge and at late follow-up.
Results
Early subgaleal fluid collection was observed in 36.7% (2.8% at the late follow-up), and impaired wound healing was recorded in 3.3% of all cases, with an overall need for operative revision of 6.7%. Neither usage of dural sealants, lack of watertight dural closure, and presence of subgaleal drains, nor type of skin closure or dressing influenced outcome. Curved incisions, larger craniotomy, and tumor size, however, were associated with an increase in early CSF or hematoma collection (p < 0.0001, p = 0.001, p < 0.01 resp.), and larger craniotomy size was associated with longer persistence of subgaleal fluid collections (p < 0.05).
Conclusions
Based on our setting, individual surgical nuances such as the type of dural closure and the use of subgaleal drains resulted in a comparable complication rate and outcome. Subgaleal fluid collections were frequently observed after supratentorial procedures, irrespective of the closing technique employed, and resolve spontaneously in the majority of cases without significant sequelae. Our results are limited due to the observational nature in our single-center study and need to be validated by supportive prospective randomized design.
Bonding of polymer-based microfluidics to polymer substrates still poses a challenge for Lab-On-a-Chip applications. Especially, when sensing elements are incorporated, patterned deposition of adhesives with curing at ambient conditions is required. Here, we demonstrate a fabrication method for fully printed microfluidic systems with sensing elements using inkjet and stereolithographic 3D-printing.
Plate osteosynthesis of displaced proximal phalangeal neck fractures of the hand allows early mobilization due to a stable internal fixation. Nevertheless, joint stiffness—because of soft tissue irritation—represents a common complication leading to high complication rates. Del Pinal et al. recently reported promising clinical results for a new, minimally invasive fixation technique with a cannulated headless intramedullary compression screw. Hence, the aim of this study was to compare plate fixation of proximal phalangeal neck fractures to less two less invasive techniques: Crossed k-wire fixation and intramedullary screw fixation. We hypothesized that these fixation techniques provide inferior stability when compared to plate osteosynthesis.
Surgical reconstruction of the interosseous membrane (IOM) could restore longitudinal forearm stability to avoid persisting disability due to capituloradial and ulnocarpal impingement in Essex Lopresti lesions. This biomechanical study aimed to assess longitudinal forearm stability of intact specimens, after sectioning of the IOM and after reconstruction with a TightRope construct using either a single or double bundle technique.
Treatment of posttraumatic osteoarthritis of the radial column of the elbow joint remains a challenging yet common issue.
While partial joint replacement leads to high revision rates, radial head excision has shown to severely increase joint instability. Shortening osteotomy of the radius could be an option to decrease the contact pressure of the radiohumeral joint and thereby pain levels without causing valgus instability. Hence, the aim of this biomechanical study was to evaluate the effects of radial shortening on axial load distribution and valgus stability of the elbow joint.
Many applications in computational science and engineering require the computation of eigenvalues and vectors of dense symmetric or Hermitian matrices. For example, in DFT (density functional theory) calculations on modern supercomputers 10% to 30% of the eigenvalues and eigenvectors of huge dense matrices have to be calculated. Therefore, performance and parallel scaling of the used eigensolvers is of upmost interest. In this article different routines of the linear algebra packages ScaLAPACK and Elemental for parallel solution of the symmetric eigenvalue problem are compared concerning their performance on the BlueGene/P supercomputer. Parameters for performance optimization are adjusted for the different data distribution methods used in the two libraries. It is found that for all test cases the new library Elemental which uses a two-dimensional element by element distribution of the matrices to the processors shows better performance than the old ScaLAPACK library which uses a block-cyclic distribution.
A novel photoexcitation method for the light-addressable potentiometric sensor (LAPS) is proposed to achieve a higher spatial resolution of chemical images. The proposed method employs a combined light source that consists of a modulated light probe, which generates the alternating photocurrent signal, and a ring of constant illumination surrounding it. The constant illumination generates a sheath of carriers with increased concentration which suppresses the spread of photocarriers by enhanced recombination. A device simulation was carried out to verify the effect of constant illumination on the spatial resolution, which demonstrated that a higher spatial resolution can be obtained.
A novel photoexcitation method for the light-addressable potentiometric sensor (LAPS) realized a higher spatial resolution of chemical imaging. In this method, a modulated light probe, which generates the alternating photocurrent signal, is surrounded by a ring of constant light, which suppresses the lateral diffusion of photocarriers by enhancing recombination. A device simulation verified that a higher spatial resolution could be obtained by adjusting the gap between the modulated and constant light. It was also found that a higher intensity and a longer wavelength of constant light was more effective. However, there exists a tradeoff between the spatial resolution and the amplitude of the photocurrent, and thus, the signal-to-noise ratio. A tilted incidence of constant light was applied, which could achieve even higher resolution with a smaller loss of photocurrent.
As a semiconductor-based electrochemical sensor, the light-addressable potentiometric sensor (LAPS) can realize two dimensional visualization of (bio-)chemical reactions at the sensor surface addressed by localized illumination. Thanks to this imaging capability, various applications in biochemical and biomedical fields are expected, for which the spatial resolution is critically significant. In this study, therefore, the spatial resolution of the LAPS was investigated in detail based on the device simulation. By calculating the spatiotemporal change of the distributions of electrons and holes inside the semiconductor layer in response to a modulated illumination, the photocurrent response as well as the spatial resolution was obtained as a function of various parameters such as the thickness of the Si substrate, the doping concentration, the wavelength and the intensity of illumination.
The simulation results verified that both thinning the semiconductor substrate and increasing the doping concentration could improve the spatial resolution, which were in good agreement with known experimental results and theoretical analysis. More importantly, new findings of interests were also obtained. As for the dependence on the wavelength of illumination, it was found that the known dependence was not always the case. When the Si substrate was thick, a longer wavelength resulted in a higher spatial resolution which was known by experiments. When the Si substrate was thin, however, a longer wavelength of light resulted in a lower spatial resolution. This finding was explained as an effect of raised concentration of carriers, which reduced the thickness of the space charge region.
The device simulation was found to be helpful to understand the relationship between the spatial resolution and device parameters, to understand the physics behind it, and to optimize the device structure and measurement conditions for realizing higher performance of chemical imaging systems.