Refine
Year of publication
Institute
- INB - Institut für Nano- und Biotechnologien (557) (remove)
Language
- English (557) (remove)
Document Type
- Article (503)
- Conference Proceeding (39)
- Part of a Book (8)
- Doctoral Thesis (3)
- Book (2)
- Other (2)
Keywords
- Biosensor (6)
- biosensors (4)
- frequency mixing magnetic detection (4)
- LAPS (3)
- Label-free detection (3)
- Light-addressable potentiometric sensor (3)
- capacitive field-effect sensor (3)
- field-effect sensor (3)
- hydrogen peroxide (3)
- magnetic nanoparticles (3)
- tobacco mosaic virus (TMV) (3)
- Acyl-amino acids (2)
- Aminoacylase (2)
- Bacillaceae (2)
- Bacillus atrophaeus (2)
- Biotechnological application (2)
- Calorimetric gas sensor (2)
- Capacitive field-effect sensor (2)
- Hydrogen peroxide (2)
- Raman spectroscopy (2)
- Subtilases (2)
- Subtilisin (2)
- Tobacco mosaic virus (TMV) (2)
- acetoin (2)
- capacitive field-effect sensors (2)
- gold nanoparticles (2)
- light-addressable potentiometric sensor (2)
- microfluidics (2)
- penicillinase (2)
- sterilisation (2)
- (Bio)degradation (1)
- Acylation (1)
- Alginate beads (1)
- Alkalihalobacillus okhensis (1)
- Bacillus atrophaeus spores (1)
- Bio-Sensors (1)
- Bioabsorbable (1)
- Biocatalysis (1)
- Biosensorik (1)
- Biosurfactants (1)
- Broad pH spectrum (1)
- CNOT (1)
- CRISPR/Cas9 (1)
- Capacitive field-effect (1)
- Capacitive model (1)
- Chaperone (1)
- Chaperone co-expression (1)
- Chemical images (1)
- Chemical imaging (1)
- Chemical imaging sensor (1)
- Chemical sensor (1)
- Coat protein (1)
- C–V method (1)
- DNA biosensor (1)
- DPA (dipicolinic acid) (1)
- Dehydrogenase (1)
- Detergent protease (1)
- Diaphorase (1)
- E. coli detection (1)
- EIS capacitive sensor (1)
- Electrolyte–insulator–semiconductor (1)
- Enzymatic biosensor (1)
- Enzyme coverage (1)
- Enzyme logic gate (1)
- Enzyme nanocarrier (1)
- Extracellular enzymes (1)
- Field effect (1)
- Field-effect biosensor (1)
- Field-effect device (1)
- Field-effect sensor (1)
- GaAs hot electron injector (1)
- Gas sensor (1)
- Glucose biosensor (1)
- Glucose oxidase (1)
- Gold nanoparticles (1)
- Gunn diode (1)
- Halotolerant protease (1)
- Heavy metal detection (1)
- Hypersecretion (1)
- ISFET (1)
- Impedance spectroscopy (1)
- Inclusion bodies (1)
- Lab-on-Chip (1)
- Layer-by-layer adsorption (1)
- LbL films (1)
- MOS (1)
- Marker-free mutagenesis (1)
- Master stamp (1)
- Multi-sensor system (1)
- Multianalyte detection (1)
- Multicell (1)
- Multiplexing (1)
- Nano Materials (1)
- Nanomaterial (1)
- Nanostructuring (1)
- Nanotechnologie (1)
- Negative impedance convertor (1)
- O2 plasma (1)
- Organic light-emitting diode display (1)
- Penicillin (1)
- Photolithographic mimics (1)
- Plant virus (1)
- Poly(allylamine hydrochloride) (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Polylactide acid (1)
- Potentiometry (1)
- Quartz crystal microbalance (1)
- Real-time monitoring (1)
- Resistive temperature detector (1)
- Resonance-mode measurement (1)
- Silk fibroin (1)
- Simultaneous determination (1)
- Sn₃O₄ (1)
- Stenotrophomonas maltophilia (1)
- Sterilisation process (1)
- Streptomyces griseus (1)
- Streptomyces lividans (1)
- Surface imprinted polymer (1)
- TMV adsorption (1)
- Ta₂O₅ gate (1)
- Tobacco mosaic virus (1)
- Uracil-phosphoribosyltransferase (1)
- Vibrio natriegens (1)
- Wafer (1)
- XOR (1)
- Zeta potential (1)
- acetoin reductase (1)
- actuator-sensor system (1)
- alcoholic beverages (1)
- aminooctanethiol (1)
- amperometric biosensors (1)
- annealing (1)
- aquaculture (1)
- artificial olfactory image (1)
- aseptic parameters (1)
- aspergillus (1)
- atomic layer deposition (1)
- bi-enzyme biosensor (1)
- bioburdens (1)
- biocompatible (1)
- biocompatible materials (1)
- biodegradabl (1)
- biodegradable electronic devices (1)
- biosensor (1)
- calorimetric gas sensor (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- capacitive EIS sensor (1)
- capacitive electrolyte–insulator–semiconductor sensors (1)
- capacitive field-effect biosensor (1)
- capacitive model (1)
- capillary micro-droplet cell (1)
- carbon electrodes (1)
- catalytic decomposition (1)
- catalytic metal (1)
- chemical sensor (1)
- chip-based sensor setup (1)
- colorization (1)
- control gate (1)
- coupled Néel–Brownian relaxation dynamics (1)
- detection of charged macromolecules (1)
- detergent protease (1)
- electrical conductivity of liquids (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- electrolyte-insulator-semiconductor capacitors (1)
- electronic nose (1)
- encapsulation materials (1)
- endospores (1)
- enzymatic biosensor (1)
- enzyme cascade (1)
- enzyme immobilization (1)
- enzyme kinetics (1)
- enzyme-logic gate (1)
- equivalent circuit (1)
- fibroin (1)
- field-effect structure (1)
- filamentous fungi (1)
- frequency mixing (1)
- gas sensor (1)
- gaseous hydrogen peroxide (1)
- genome engineering (1)
- glucose (1)
- glucose oxidase (GOx) (1)
- graphene oxide (1)
- halotolerant protease (1)
- heavy metals (1)
- high-alkaline subtilisin (1)
- horseradish peroxidase (HRP) (1)
- hydroxylation (1)
- immobilization (1)
- impedance spectroscopy (1)
- key performance indicators (1)
- layer expansion (1)
- layer-by-layer technique (1)
- light-addressable electrode (1)
- light-addressing technologies (1)
- magnetic actuation (1)
- magnetic beads (1)
- magnetic biosensing (1)
- magnetic relaxation (1)
- magnetic sandwich immunoassay (1)
- magnetic sensing (1)
- magnetic sensors (1)
- magnetic separation (1)
- magnetic tweezers (1)
- magnetophoretic velocity (1)
- metal-oxide-semiconductor structure (1)
- micromagnetic simulation (1)
- microwave generation (1)
- multi-sensing platform (1)
- multianalyte detection (1)
- multiparametric immunoassays (1)
- multiplex detection (1)
- nanobelts (1)
- nanomaterials (1)
- nanoparticle coverage (1)
- on-chip integrated addressable EISCAP sensors (1)
- optical sensor setup (1)
- optical spore trapping (1)
- optical trapping (1)
- organic PVC membranes (1)
- organosilanes (1)
- oxidative stable protease (1)
- pH sensors (1)
- pattern-size reduction (1)
- penicillin (1)
- photoelectrochemistry (1)
- plant virus detection (1)
- plug-based microfluidic device (1)
- polyaniline (1)
- polystyrene sulfonate (1)
- recombinant expression (1)
- scanned light pulse technique (1)
- self-aligned patterning (1)
- silanization (1)
- spore kill rate (1)
- sterility (1)
- sterility tests (1)
- sterilization (1)
- sterilization conditions (1)
- sterilization efficacy (1)
- sterilization methods (1)
- superparamagnetic bead (1)
- superparamagnetic nanoparticles (1)
- surface functionalization (1)
- temperature (1)
- thermometry (1)
- thin-film microsensors (1)
- titanium dioxide photoanode (1)
- turnip vein clearing virus (TVCV) (1)
- ultrathin gate insulators (1)
- urease (1)
- validation methods (1)
- visualization (1)
- wafer-level testing (1)
- α-aminoacylase (1)
- ε-lysine acylase (1)
A new microfluidic assembly method for semiconductor-based biosensors using 3D-printing technologies was proposed for a rapid and cost-efficient design of new sensor systems. The microfluidic unit is designed and printed by a 3D-printer in just a few hours and assembled on a light-addressable potentiometric sensor (LAPS) chip using a photo resin. The cell growth curves obtained from culturing cells within microfluidics-based LAPS systems were compared with cell growth curves in cell culture flasks to examine biocompatibility of the 3D-printed chips. Furthermore, an optimal cell culturing within microfluidics-based LAPS chips was achieved by adjusting the fetal calf serum concentrations of the cell culture medium, an important factor for the cell proliferation.
The metabolic activity of Chinese hamster ovary (CHO) cells was observed using a light-addressable potentiometric sensor (LAPS). The dependency toward different glucose concentrations (17–200 mM) follows a Michaelis–Menten kinetics trajectory with Kₘ = 32.8 mM, and the obtained Kₘ value in this experiment was compared with that found in literature. In addition, the pH shift induced by glucose metabolism of tumor cells transfected with the HPV-16 genome (C3 cells) was successfully observed. These results indicate the possibility to determine the tumor cells metabolism with a LAPS-based measurement device.
Die Detektion von Schadstoffen repräsentiert in der Umweltanalytik eine wichtige Aufgabenstellung. Gerade die Abwasser- bzw. Brauchwasseranalytik sowie die Prozesskontrolle haben einen hohen Stellenwert. Siliziumbasierte Dünnschichtsensoren bieten eine kostengünstige Möglichkeit, „online“-Messungen bzw. Vor-Ort-Messungen zeitnah durchzuführen. In dieser Arbeit wird ein potentiometrisches Sensorarray auf der Basis von Chalkogenidgläsern zur Detektion von Schwermetallen in wässrigen Medien vorgestellt.
Chalcogenide glass materials as membranes for potentiometric sensors for chemical analysis in solutions have been studied since more than 20 years. In this work, an electrolyte–insulator–semiconductor structure was combined with chalcogenide glass membranes prepared by means of the pulsed laser deposition technique. Depending on the membrane composition a selectivity to different ions (Cd2+ and Pb2+) is achieved. The different sensor membranes have been physically characterised using microscopy, ellipsometry, profilometry, atomic force microscopy (AFM), scanning electron microscopy (SEM) and Rutherford backscattering spectrometry (RBS). The electrochemical behaviour has been investigated via capacitance/voltage (C/V) and constant capacitance (ConCap) measurements and results in a Cd2+ sensitivity of 23.1 ± 0.6 mV per decade in a linear range from 7 × 10−6 to 10−2 mol/l and 24.4 ± 0.5 mV per decade in a linear range from 5 × 10−6 to 10−2 mol/l for Pb2+, respectively.
In industrial processes there is a variety of heavy metals (e.g., copper, zinc, cadmium, and lead) in use for wires, coatings, paints, alloys, batteries, etc. Since the application of these transition metals for industry is inevitable, it is a vital task to develop proper analytical techniques for their monitoring at low activity levels, especially because most of these elements are acutely toxic for biological organisms. The determination of ions in solution by means of a simple and inexpensive sensor array is, therefore, a promising task. In this work, a sensor array with heavy metal-sensitive chalcogenide glass membranes for the simultaneous detection of the four ions Ag⁺, Cu2⁺, Cd2⁺, and Pb2⁺ in solution is realized. The results of the physical characterization by means of microscopy, profilometry, Rutherford backscattering spectroscopy (RBS), and scanning electron microscopy (SEM) as well as the electrochemical characterization by means of potentiometric measurements are presented. Additionally, the possibility to expand the sensor array by polymeric sensor membranes is discussed.
The capacitive electrolyte–insulator–semiconductor (EIS) structure is a typical device based on a field-effect sensor platform. With a simple silicon-based structure, EIS have been useful for several sensing applications, especially with incorporation of nanostructured films to modulate the ionic transport and the flat-band potential. In this paper, we report on ion transport and changes in flat-band potential in EIS sensors made with layer-by-layer films containing poly(amidoamine) (PAMAM) dendrimer and single-walled carbon nanotubes (SWNTs) adsorbed on p-Si/SiO 2 /Ta 2 O 5 chips with an Al ohmic contact. The impedance spectra were fitted using an equivalent circuit model, from which we could determine parameters such as the double-layer capacitance. This capacitance decreased with the number of bilayers owing to space charge accumulated at the electrolyte–insulator interface, up to three PAMAM/SWNTs bilayers, after which it stabilized. The charge-transfer resistance was also minimum for three bilayers, thus indicating that this is the ideal architecture for an optimized EIS performance. The understanding of the influence of nanostructures and the fine control of operation parameters pave the way for optimizing the design and performance of new EIS sensors.
The control of molecular architecture provided by the layer-by-layer (LbL) technique has led to enhanced biosensors, in which advantageous features of distinct materials can be combined. Full optimization of biosensing performance, however, is only reached if the film morphology is suitable for the principle of detection of a specific biosensor. In this paper, we report a detailed morphology analysis of LbL films made with alternating layers of single-walled carbon nanotubes (SWNTs) and polyamidoamine (PAMAM) dendrimers, which were then covered with a layer of penicillinase (PEN). An optimized performance to detect penicillin G was obtained with 6-bilayer SWNT/PAMAM LbL films deposited on p-Si-SiO2-Ta2O5 chips, used in biosensors based on a capacitive electrolyte-insulator-semiconductor (EIS) and a light-addressable potentiometric sensor (LAPS) structure, respectively. Field-emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM) images indicated that the LbL films were porous, with a large surface area due to interconnection of SWNT into PAMAM layers. This morphology was instrumental for the adsorption of a larger quantity of PEN, with the resulting LbL film being highly stable. The experiments to detect penicillin were performed with constant-capacitance (ConCap) and constant-current (CC) measurements for EIS and LAPS sensors, respectively, which revealed an enhanced detection signal and sensitivity of ca. 100 mV/decade for the field-effect sensors modified with the PAMAM/SWNT LbL film. It is concluded that controlling film morphology is essential for an enhanced performance of biosensors, not only in terms of sensitivity but also stability and response time.
Layer-by-Layer Assembly of Carbon Nanotubes Incorporated in Light-Addressable Potentiometric Sensors
(2009)
The ideal combination among biomolecules and nanomaterials is the key for reaching biosensing units with high sensitivity. The challenge, however, is to find out a stable and sensitive film architecture that can be incorporated on the sensor’s surface. In this paper, we report on the benefits of incorporating a layer-by-layer (LbL) nanofilm of polyamidoamine (PAMAM) dendrimer and carbon nanotubes (CNTs) on capacitive electrolyte-insulator-semiconductor (EIS) field-effect sensors for detecting urea. Three sensor arrangements were studied in order to investigate the adequate film architecture, involving the LbL film with the enzyme urease: (i) urease immobilized directly onto a bare EIS [EIS-urease] sensor; (ii) urease atop the LbL film over the EIS [EIS-(PAMAM/CNT)-urease] sensor; and (iii) urease sandwiched between the LbL film and another CNT layer [EIS-(PAMAM/CNT)-urease-CNT]. The surface morphology of all three urea-based EIS biosensors was investigated by atomic force microscopy (AFM), while the biosensing abilities were studied by means of capacitance–voltage (C/V) and dynamic constant-capacitance (ConCap) measureaments at urea concentrations ranging from 0.1 mM to 100 mM. The EIS-urease and EIS-(PAMAM/CNT)-urease sensors showed similar sensitivity (∼18 mV/decade) and a nonregular signal behavior as the urea concentration increased. On the other hand, the EIS-(PAMAM/CNT)-urease-CNT sensor exhibited a superior output signal performance and higher sensitivity of about 33 mV/decade. The presence of the additional CNT layer was decisive to achieve a urea based EIS sensor with enhanced properties. Such sensitive architecture demonstrates that the incorporation of an adequate hybrid enzyme-nanofilm as sensing unit opens new prospects for biosensing applications using the field-effect sensor platform.
Strategies of miniaturised reference electrodes integrated in a silicon-based „one chip“ pH sensor
(2003)
Miniaturised reference electrodes for field-effect sensors compatible to silicon chip technology
(2005)
Gas sensor investigation based on a catalytically activated thin-film thermopile for H2O2 detection
(2010)
In aseptic filling systems, hydrogen peroxide vapour is commonly used for the reduction of microbial contaminations in carton packages. In this process, the germicidal efficiency of the vapour depends especially on the H₂O₂ concentration. To monitor the H₂O₂ concentration, a calorimetric H₂O₂ gas sensor based on a catalytically activated thin-film thermopile is investigated. Two different sensor layouts, namely a circular and a linear form, as well as two various material pairs such as tungsten/nickel and gold/nickel, have been examined for the realization of a thin-film thermopile. Additionally, manganese oxide and palladium particles have been compared as responsive catalysts towards H₂O₂. The thin-film sensors have been investigated at various H₂O₂ concentrations, gas temperatures and flow rates.
Field-effect EIS (electrolyte-insulator-semiconductor) sensors modified with a positively charged weak polyelectrolyte layer have been applied for the electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge. The EIS sensors are able to detect the existence of target DNA amplicons in PCR (polymerase chain reaction) samples and thus, can be used as tool for a quick verification of DNA amplification and the successful PCR process. Due to their miniaturized setup, compatibility with advanced micro- and nanotechnologies, and ability to detect biomolecules by their intrinsic molecular charge, those sensors can serve as possible platform for the development of label-free DNA chips. Possible application fields as well as challenges and limitations will be discussed.
Proceedings of the 2nd Humboldt Kolleg, Hammamet, Tunisia Organizer: Alexander von Humboldt Stiftung, Germany. pdf 184 p. Welcome Address Dear Participants, Welcome to the 2nd Humboldt Kolleg in “Nanoscale Science and Technology” (NS&T’12) in Tunisia, sponsored by the "Alexander von Humboldt" foundation. The NS&T’12 multidisciplinary scientific program includes seven "hot" topics dealing with "Nanoscale Science and Technology" covering basic and application-oriented research as well as industrial (market) aspects: - Molecular Biophyics, Spectroscopy Techniques, Imaging Microscopy - Nanomaterials Synthesis for Medicine and Bio-chemical Sensors - Nanostructures, Semiconductors, Photonics and Nanodevices - New Technologies in Market Industry - Environment, Electro-chemistry, Bio-polymers and Fuel Cells - Nanomaterials, Photovoltaic, Modelling, Quantum Physics - Microelectronics, Sensors Networks and Embedded Systems We are deeply indebted to all members of the Scientific Committee and General Chairs for joint Sessions and to all speakers and chairmen, who have dedicated invaluable time and efforts for the realization of this event. On behalf of the Organizing Committee, we are cordially inviting you to join the conference and hope that your stay will be fruitful, rewarding and enjoyable. Prof. Dr. Michael J. Schöning, Prof. Dr. Adnane Abdelghani
In vitro studies of the degradation kinetic of biopolymers are essential for the design and optimization of implantable biomedical devices. In the presented work, a field-effect capacitive sensor has been applied for the real-time and in situ monitoring of degradation processes of biopolymers for the first time. The polymer-covered field-effect sensor is, in principle, capable to detect any changes in bulk, surface and interface properties of the polymer induced by degradation processes. The feasibility of this approach has been experimentally proven by using the commercially available biomedical polymer poly(D,L-lactic acid) (PDLLA) as a model system. PDLLA films of different thicknesses were deposited on the Ta₂O₅-gate surface of the field-effect structure from a polymer solution by means of spin-coating method. The polymer-modified field-effect sensors have been characterized by means of capacitance–voltage and impedance-spectroscopy method. The degradation of the PDLLA was accelerated by changing the degradation medium from neutral (pH 7.2) to alkaline (pH 9) condition, resulting in drastic changes in the capacitance and impedance spectra of the polymer-modified field-effect sensor.
The characterization of the degradation kinetics of biodegradable polymers is mandatory with regard to their proper application. In the present work, polymer-modified electrolyte–insulator–semiconductor (PMEIS) field-effect sensors have been applied for in-situ monitoring of the pH-dependent degradation kinetics of the commercially available biopolymer poly(d,l-lactic acid) (PDLLA) in buffer solutions from pH 3 to pH 13. PDLLA films of 500 nm thickness were deposited on the surface of an Al–p-Si–SiO2–Ta2O5 structure from a polymer solution by means of spin-coating method. The PMEIS sensor is, in principle, capable to detect any changes in bulk, surface and interface properties of the polymer induced by degradation processes. A faster degradation has been observed for PDLLA films exposed to alkaline solutions (pH 9, pH 11 and pH 13).
Impedance spectroscopy: A tool for real-time in situ monitoring of the degradation of biopolymers
(2013)
Investigation of the degradation kinetics of biodegradable polymers is essential for the development of implantable biomedical devices with predicted biodegradability. In this work, an impedimetric sensor has been applied for real-time and in situ monitoring of degradation processes of biopolymers. The sensor consists of two platinum thin-film electrodes covered by a polymer film to be studied. The benchmark biomedical polymer poly(D,L-lactic acid) (PDLLA) was used as a model system. PDLLA films were deposited on the sensor structure from a polymer solution by using the spin-coating method. The degradation kinetics of PDLLA films have been studied in alkaline solutions of pH 9 and 12 by means of an impedance spectroscopy (IS) method. Any changes in a polymer capacitance/resistance induced by water uptake and/or polymer degradation will modulate the global impedance of the polymer-covered sensor that can be used as an indicator of the polymer degradation. The degradation rate can be evaluated from the time-dependent impedance spectra. As expected, a faster degradation has been observed for PDLLA films exposed to pH 12 solution.
Designing novel or optimizing existing biodegradable polymers for biomedical applications requires numerous tests on the effect of substances on the degradation process. In the present work, polymer-modified electrolyte–insulator–semiconductor (PMEIS) sensors have been applied for monitoring an enzymatically catalyzed degradation of polymers for the first time. The thin films of biodegradable polymer poly(d,l-lactic acid) and enzyme lipase were used as a model system. During degradation, the sensors were read-out by means of impedance spectroscopy. In order to interpret the data obtained from impedance measurements, an electrical equivalent circuit model was developed. In addition, morphological investigations of the polymer surface have been performed by means of in situ atomic force microscopy. The sensor signal change, which reflects the progress of degradation, indicates an accelerated degradation in the presence of the enzyme compared to hydrolysis in neutral pH buffer media. The degradation rate increases with increasing enzyme concentration. The obtained results demonstrate the potential of PMEIS sensors as a very promising tool for in situ and real-time monitoring of degradation of polymers.
A sensor system for investigating (bio)degradationprocesses of polymers is presented. The system utilizes semiconductor field-effect sensors and is capable of monitoring the degradation process in-situ and in real-time. The degradation of the polymer poly(d,l-lactic acid) is exemplarily monitored in solutions with different pH value, pH-buffer solution containing the model enzyme lipase from Rhizomucormiehei and cell-culture medium containing supernatants from stimulated and non-stimulated THP-1-derived macrophages mimicking activation of the immune system.
Characterising an insect antenna as a receptor for a biosensor by means of impedance spectroscopy
(2001)
The Gram-positive endospore-forming bacterium Bacillus licheniformis can be found widely in nature and it is exploited in industrial processes for the manufacturing of antibiotics, specialty chemicals, and enzymes. Both in its varied natural habitats and in industrial settings, B. licheniformis cells will be exposed to increases in the external osmolarity, conditions that trigger water efflux, impair turgor, cause the cessation of growth, and negatively affect the productivity of cell factories in biotechnological processes. We have taken here both systems-wide and targeted physiological approaches to unravel the core of the osmostress responses of B. licheniformis. Cells were suddenly subjected to an osmotic upshift of considerable magnitude (with 1 M NaCl), and their transcriptional profile was then recorded in a time-resolved fashion on a genome-wide scale. A bioinformatics cluster analysis was used to group the osmotically up-regulated genes into categories that are functionally associated with the synthesis and import of osmostress-relieving compounds (compatible solutes), the SigB-controlled general stress response, and genes whose functional annotation suggests that salt stress triggers secondary oxidative stress responses in B. licheniformis. The data set focusing on the transcriptional profile of B. licheniformis was enriched by proteomics aimed at identifying those proteins that were accumulated by the cells through increased biosynthesis in response to osmotic stress. Furthermore, these global approaches were augmented by a set of experiments that addressed the synthesis of the compatible solutes proline and glycine betaine and assessed the growth-enhancing effects of various osmoprotectants. Combined, our data provide a blueprint of the cellular adjustment processes of B. licheniformis to both sudden and sustained osmotic stress.
In this paper, carbon nanotubes (CNTs) were incorporated in penicillinase-phospholipid Langmuir and Langmuir–Blodgett (LB) films to enhance the enzyme catalytic properties. Adsorption of the penicillinase and CNTs at dimyristoylphosphatidic acid (DMPA) monolayers at the air–water interface was investigated by surface pressure–area isotherms, vibrational spectroscopy, and Brewster angle microscopy. The floating monolayers were transferred to solid supports through the LB technique, forming mixed DMPA-CNTs-PEN films, which were investigated by quartz crystal microbalance, vibrational spectroscopy, and atomic force microscopy. Enzyme activity was studied with UV–vis spectroscopy and the feasibility of the supramolecular device nanostructured as ultrathin films were essayed in a capacitive electrolyte–insulator–semiconductor (EIS) sensor device. The presence of CNTs in the enzyme–lipid LB film not only tuned the catalytic activity of penicillinase but also helped conserve its enzyme activity after weeks, showing increased values of activity. Viability as penicillin sensor was demonstrated with capacitance/voltage and constant capacitance measurements, exhibiting regular and distinctive output signals over all concentrations used in this work. These results may be related not only to the nanostructured system provided by the film, but also to the synergism between the compounds on the active layer, leading to a surface morphology that allowed a fast analyte diffusion because of an adequate molecular accommodation, which also preserved the penicillinase activity. This work therefore demonstrates the feasibility of employing LB films composed of lipids, CNTs, and enzymes as EIS devices for biosensing applications.