Article
Refine
Year of publication
Institute
- Fachbereich Energietechnik (605) (remove)
Language
- English (358)
- German (245)
- Multiple languages (1)
- Dutch (1)
Document Type
- Article (605) (remove)
Keywords
- Earthquake (4)
- Blitzschutz (3)
- Lightning protection (2)
- Algal Turf Scrubber (1)
- Algal–bacterial bioflm (1)
- Alternative Energiequelle (1)
- Antibias (1)
- Artificial intelligence (1)
- BIM (1)
- Basisisolierung (1)
Partikelmesstechnik
(2002)
We analyze the influence of dipole-dipole interactions in an electromagnetically induced transparency set up for a density at the onset of cooperative effects. To this end, we include mean-field models for the influence of local-field corrections and radiation trapping into our calculation. We show both analytically and numerically that the polarization contribution to the local field strongly modulates the phase of a weak pulse. We give an intuitive explanation for this local-field-induced phase modulation and demonstrate that it distinctively differs from the nonlinear self-phase-modulation that a strong pulse experiences in a Kerr medium.
In recent years, many onshore wind turbines are erected in seismic active regions and on soils with poor load bearing capacity, where pile grids are inevitable to transfer the loads into the ground. In this contribution, a realistic multi pile grid is designed to analyze the dynamics of a wind turbine tower including frequency dependent soil-structure-interaction. It turns out that different foundations on varying soil configurations heavily influence the vibration response. While the vibration amplitude is mostly attenuated, certain unfavorable combinations of structure and soil parameters lead to amplification in the range of the system's natural frequencies. This testifies the need for overall dynamic analysis in the assessment of the dynamic stability and the holistic frequency tuning of the turbines.
Plans for investigations of subthreshold K+ production in p+A collisions / O. W. B. Schult [u.a.]
(1995)
Prinzip und Anwendung der akustischen Gastemperaturmeßtechnik / Deuster, M. ; Brüssermann, Klaus
(1994)
Experimental determination of the cross sections of proton capture on radioactive nuclei is extremely difficult. Therefore, it is of substantial interest for the understanding of the production of the p-nuclei. For the first time, a direct measurement of proton-capture cross sections on stored, radioactive ions became possible in an energy range of interest for nuclear astrophysics. The experiment was performed at the Experimental Storage Ring (ESR) at GSI by making use of a sensitive method to measure (p,γ) and (p,n) reactions in inverse kinematics. These reaction channels are of high relevance for the nucleosyn-thesis processes in supernovae, which are among the most violent explosions in the universe and are not yet well understood. The cross section of the ¹¹⁸Te(p,γ) reaction has been measured at energies of 6 MeV/u and 7 MeV/u. The heavy ions interacted with a hydrogen gas jet target. The radiative recombination process of the fully stripped ¹¹⁸Te ions and electrons from the hydrogen target was used as a luminosity monitor. An overview of the experimental method and preliminary results from the ongoing analysis will be presented.
Pseudo-dynamische Versuche an Reihenmittelhäusern – Vergleich mit aktuellen Berechnungsansätzen
(2008)
Quantifying and minimizing uncertainty is vital for simulating technically and economically successful geothermal reservoirs. To this end, we apply a stochastic modelling sequence, a Monte Carlo study, based on (i) creating an ensemble of possible realizations of a reservoir model, (ii) forward simulation of fluid flow and heat transport, and (iii) constraining post-processing using observed state variables. To generate the ensemble, we use the stochastic algorithm of Sequential Gaussian Simulation and test its potential fitting rock properties, such as thermal conductivity and permeability, of a synthetic reference model and—performing a corresponding forward simulation—state variables such as temperature. The ensemble yields probability distributions of rock properties and state variables at any location inside the reservoir. In addition, we perform a constraining post-processing in order to minimize the uncertainty of the obtained distributions by conditioning the ensemble to observed state variables, in this case temperature. This constraining post-processing works particularly well on systems dominated by fluid flow. The stochastic modelling sequence is applied to a large, steady-state 3-D heat flow model of a reservoir in The Hague, Netherlands. The spatial thermal conductivity distribution is simulated stochastically based on available logging data. Errors of bottom-hole temperatures provide thresholds for the constraining technique performed afterwards. This reduce the temperature uncertainty for the proposed target location significantly from 25 to 12 K (full distribution width) in a depth of 2300 m. Assuming a Gaussian shape of the temperature distribution, the standard deviation is 1.8 K. To allow a more comprehensive approach to quantify uncertainty, we also implement the stochastic simulation of boundary conditions and demonstrate this for the basal specific heat flow in the reservoir of The Hague. As expected, this results in a larger distribution width and hence, a larger, but more realistic uncertainty estimate. However, applying the constraining post-processing the uncertainty is again reduced to the level of the post-processing without stochastic boundary simulation. Thus, constraining post-processing is a suitable tool for reducing uncertainty estimates by observed state variables.
Large scale central receiver systems typically deploy between thousands to more than a hundred thousand heliostats. During solar operation, each heliostat is aligned individually in such a way that the overall surface normal bisects the angle between the sun’s position and the aim point coordinate on the receiver. Due to various tracking error sources, achieving accurate alignment ≤1 mrad for all the heliostats with respect to the aim points on the receiver without a calibration system can be regarded as unrealistic. Therefore, a calibration system is necessary not only to improve the aiming accuracy for achieving desired flux distributions but also to reduce or eliminate spillage. An overview of current larger-scale central receiver systems (CRS), tracking error sources and the basic requirements of an ideal calibration system is presented. Leading up to the main topic, a description of general and specific terms on the topics heliostat calibration and tracking control clarifies the terminology used in this work. Various figures illustrate the signal flows along various typical components as well as the corresponding monitoring or measuring devices that indicate or measure along the signal (or effect) chain. The numerous calibration systems are described in detail and classified in groups. Two tables allow the juxtaposition of the calibration methods for a better comparison. In an assessment, the advantages and disadvantages of individual calibration methods are presented.
Ein vorausschauendes Risikomanagement beinhaltet, Risiken zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent,welche Risiken sinnvoll über Versicherungen abgedeckt werden sollten. Bei Unternehmen, die mit umfangreichen elektronischenEinrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Berücksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nichtverfügbarkeit der elektronischen Einrichtungen und damit derProduktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardwareschaden an der betroffenen Anlage oft bei weitem übersteigt.
Past earthquakes demonstrated the high vulnerability of industrial facilities equipped with complex process technologies leading to serious damage of process equipment and multiple and simultaneous release of hazardous substances. Nonetheless, current standards for seismic design of industrial facilities are considered inadequate to guarantee proper safety conditions against exceptional events entailing loss of containment and related consequences. On these premises, the SPIF project -Seismic Performance of Multi-Component Systems in Special Risk Industrial Facilities- was proposed within the framework of the European H2020 SERA funding scheme. In detail, the objective of the SPIF project is the investigation of the seismic behaviour of a representative industrial multi-storey frame structure equipped with complex process components by means of shaking table tests. Along this main vein and in a performance-based design perspective, the issues investigated in depth are the interaction between a primary moment resisting frame (MRF) steel structure and secondary process components that influence the performance of the whole system; and a proper check of floor spectra predictions. The evaluation of experimental data clearly shows a favourable performance of the MRF structure, some weaknesses of local details due to the interaction between floor crossbeams and process components and, finally, the overconservatism of current design standards w.r.t. floor spectra predictions.
A refined substructure technique in the frequency domain is developed, which permits consideration of the interaction effects among adjacent containers through the supporting deformable soil medium. The tank-liquid systems are represented by means of mechanical models, whereas discrete springs and dashpots stand for the soil beneath the foundations. The proposed model is employed to assess the responses of adjacent circular, cylindrical tanks for harmonic and seismic excitations over wide range of tank proportions and soil conditions. The influence of the number, spatial arrangement of the containers and their distance on the overall system's behavior is addressed. The results indicate that the cross-interaction effects can substantially alter the impulsive components of response of each individual element in a tank farm. The degree of this impact is primarily controlled by the tank proportions and the proximity of the predominant natural frequencies of the shell-liquid-soil systems and the input seismic motion. The group effects should be not a priori disregarded, unless the tanks are founded on shallow soil deposit overlying very stiff material or bedrock.
Die erdbebensichere Auslegung von erdverlegten Rohrleitungssystemen ist von wesentlicher Bedeutung zur Sicherstellung der Funktionalität der Versorgungsinfrastruktur nach einem Erdbebenereignis. Zur Vermeidung von Netzausfällen ist es erforderlich, die räumlich weit ausgedehnten Leitungssysteme mit geeigneten rechnerischen Modellen seismisch zu bemessen. Der vorliegende Beitrag behandelt die Beanspruchung von Rohrleitungssystemen durch seismische Welleneinwirkung und stellt geeignete Näherungsansätze und ein detailliertes Rechenmodell für seismische Leitungsanalysen vor. Mit den Ansätzen wird in Berechnungsbeispielen der Einfluss wesentlicher Parameter auf die seismisch induzierten Dehnungen in Rohrleitungssystemen untersucht.
Mit finanzieller Unterstützung der Deutschen Gesellschaft für Mauerwerks- und Wohnungsbau e.V. (DGfM) und des Deutschen Instituts für Bautechnik in Berlin (DIBt) wurden zwei aufeinander aufbauende Forschungsvorhaben zur Verbesserung der seismischen Nachweise von Mauerwerksbauten in deutschen Erdbebengebieten durchgeführt. Zunächst wurde das seismische Verhalten von drei modernen unbewehrten Mauerwerksgebäuden in der Region Emilia Romagna in Italien während der Erdbebenserie im Jahr 2012 in Kooperation mit der Universität Pavia eingehend untersucht. Aufbauend auf den Erkenntnissen dieser Untersuchungen wurde ein verbessertes seismisches Bemessungskonzept für unbewehrte Mauerwerksbauten erarbeitet. Der Beitrag stellt die wesentlichen Ergebnisse dieser Forschungsarbeiten und deren Eingang in die Normung vor.
Semi-insulating GaAs layers grown by molecular-beam epitaxy / P. Kordos ; A. Förster ; J. Betko ...
(1995)
SHEMAT-Suite: An open-source code for simulating flow, heat and species transport in porous media
(2020)
SHEMAT-Suite is a finite-difference open-source code for simulating coupled flow, heat and species transport in porous media. The code, written in Fortran-95, originates from geoscientific research in the fields of geothermics and hydrogeology. It comprises: (1) a versatile handling of input and output, (2) a modular framework for subsurface parameter modeling, (3) a multi-level OpenMP parallelization, (4) parameter estimation and data assimilation by stochastic approaches (Monte Carlo, Ensemble Kalman filter) and by deterministic Bayesian approaches based on automatic differentiation for calculating exact (truncation error-free) derivatives of the forward code.
Shielding effectiveness of reinforced concrete cable ducts carrying partial lightning currents
(1998)
Simulating the electromagnetic‐thermal treatment of thin aluminium layers for adhesion improvement
(2015)
A composite layer material used in packaging industry is made from joining layers of different materials using an adhesive. An important processing step in the production of aluminium-containing composites is the surface treatment and consequent coating of adhesive material on the aluminium surface. To increase adhesion strength between aluminium layer and the adhesive material, the foil is heat treated. For efficient heating, induction heating was considered as state-of-the-art treatment process. Due to the complexity of the heating process and the unpredictable nature of the heating source, the control of the process is not yet optimised. In this work, a finite element analysis of the process was established and various process parameters were studied. The process was simplified and modelled in 3D. The numerical model contains an air domain, an aluminium layer and a copper coil fitted with a magnetic field concentrating material. The effect of changing the speed of the aluminium foil (or rolling speed) was studied with the change of the coil current. Statistical analysis was used for generating a general control equation of coil current with changing rolling speed.
Simulation and measurement of melting effects on metal sheets caused by direct lightning strikes
(1991)
Since the 80s power production with solar thermal power plants has been a way to substitute fossil fuels. By concentrating direct solar radiation from heliostats very high temperatures of a thermal fluid can be reached. The resulting heat is converted to mechanical energy in a steam cycle which generates electricity.
High efficiencies and fast start-up are reached by using air as a heat medium, as well as using porous ceramic materials as solar receiver of the concentrated sunlight.
In Germany the construction of a 1.5 MWe solar tower power plant began in 2008. It is operational since December 2008 and started production of electricity in the spring of 2009.
In Greece and Cyprus, countries with high solar potential, the development of this competitive solar thermal technology is imperative, since it has already been implemented in other Mediterranean countries.
Solares Kochen
(1990)
Speicher statt Kohle. Integration thermischer Stromspeicher in vorhandene Kraftwerksstandorte
(2019)
Eine seismische Anregung verursacht in einem Flüssigkeitstank einen kombinierten Spannungszustand, was zu einem Stabilitätsversagen der häufig sehr dünnwandigen Konstruktionen führen kann. Für die Durchführung von Stabilitätsnachweisen stehen verschiedene Verfahren zur Verfügung. Üblicherweise werden aus Gründen der Einfachheit spannungsbasierte Verfahren angewendet. Diese sind für Einheitslastfälle experimentell abgesichert, wobei eine Übertragung auf kombinierte Spannungszustände wie im Erdbebenfall nur begrenzt möglich ist. Alternativ kann ein globales, numerisches Konzept, das LBA/MNA-Verfahren, angewendet werden. Das Verfahren kombiniert eine materiell nichtlineare Berechnung (MNA) mit einer linearen Beulanalyse (LBA) und erfasst die Interaktion verschiedener gleichzeitig auftretender Beanspruchungen implizit im Nachweis. Dieser Beitrag demonstriert die Anwendung der Verfahren am Beispiel verschiedener Tankgeometrien mit Höhe/Radius-Verhältnissen zwischen 1 ≤ H/R ≤ 2 und Radius/Tankwand-Verhältnissen zwischen 500 ≤ R/t ≤ 1000 und diskutiert zusätzlich die Defizite der spannungsbasierten Nachweisverfahren.
Die PIA GmbH prüft seit fast 8 Jahren die Standsicherheit von Behältern für Kleinkläranlagen. Diese bestehen in der Regel aus Kunststoff oder Beton und müssen über ihre gesamte Lebensdauer den Beanspruchungen aus Handhabung, Einbau und Betrieb standhalten. Die Standsicherheit kann nach EN 12566 wahlweise durch einen rechnerischen Nachweis oder durch einen praktischen Nachweis wie die Bruchlastprüfung oder die Prüfung in der Grube erfolgen.