Article
Refine
Year of publication
- 2024 (1)
- 2023 (5)
- 2022 (8)
- 2021 (3)
- 2020 (7)
- 2019 (9)
- 2018 (4)
- 2017 (6)
- 2016 (3)
- 2015 (5)
- 2014 (3)
- 2013 (6)
- 2012 (1)
- 2011 (8)
- 2010 (10)
- 2009 (5)
- 2008 (11)
- 2007 (4)
- 2006 (7)
- 2005 (7)
- 2004 (16)
- 2003 (6)
- 2002 (12)
- 2001 (10)
- 2000 (13)
- 1999 (15)
- 1998 (16)
- 1997 (23)
- 1996 (22)
- 1995 (15)
- 1994 (14)
- 1993 (11)
- 1992 (8)
- 1991 (4)
- 1990 (3)
- 1989 (11)
- 1988 (9)
- 1987 (6)
- 1986 (7)
- 1985 (6)
- 1984 (4)
- 1983 (5)
- 1982 (1)
- 1981 (3)
- 1980 (3)
- 1979 (2)
- 1978 (1)
- 1977 (1)
- 1975 (1)
Institute
- Fachbereich Energietechnik (361) (remove)
Language
- English (361) (remove)
Document Type
- Article (361) (remove)
Keywords
- Earthquake (4)
- Algal Turf Scrubber (1)
- Algal–bacterial bioflm (1)
- Antibias (1)
- Artificial intelligence (1)
- Behaviour factor q (1)
- Biogas (1)
- Cardiovascular MRI (1)
- Circular bioeconomy (1)
- Civil engineering (1)
The behaviour of infilled reinforced concrete frames under horizontal load has been widely investigated, both experimentally and numerically. Since experimental tests represent large investments, numerical simulations offer an efficient approach for a more comprehensive analysis. When RC frames with masonry infill walls are subjected to horizontal loading, their behaviour is highly non-linear after a certain limit, which makes their analysis quite difficult. The non-linear behaviour results from the complex inelastic material properties of the concrete, infill wall and conditions at the wall-frame interface. In order to investigate this non-linear behaviour in detail, a finite element model using a micro modelling approach is developed, which is able to predict the complex non-linear behaviour resulting from the different materials and their interaction. Concrete and bricks are represented by a non-linear material model, while each reinforcement bar is represented as an individual part installed in the concrete part and behaving elasto-plastically. Each brick is modelled individually and connected taking into account the non-linearity of a brick mortar interface. The same approach is followed using two finite element software packages and the results are compared with the experimental results. The numerical models show a good agreement with the experiments in predicting the overall behaviour, but also very good matching for strength capacity and drift. The results emphasize the quality and the valuable contribution of the numerical models for use in parametric studies, which are needed for the derivation of design recommendations for infilled frame structures.
Lightning safety guidelines
(2010)
Lightning protection design of a renewable energy hybrid-system without power mains connection
(2001)
Layer Deposition I
(2003)
Recent earthquakes as the 2012 Emilia earthquake sequence showed that recently built unreinforced masonry (URM) buildings behaved much better than expected and sustained, despite the maximum PGA values ranged between 0.20–0.30 g, either minor damage or structural damage that is deemed repairable. Especially low-rise residential and commercial masonry buildings with a code-conforming seismic design and detailing behaved in general very well without substantial damages. The low damage grades of modern masonry buildings that was observed during this earthquake series highlighted again that codified design procedures based on linear analysis can be rather conservative. Although advances in simulation tools make nonlinear calculation methods more readily accessible to designers, linear analyses will still be the standard design method for years to come. The present paper aims to improve the linear seismic design method by providing a proper definition of the q-factor of URM buildings. These q-factors are derived for low-rise URM buildings with rigid diaphragms which represent recent construction practise in low to moderate seismic areas of Italy and Germany. The behaviour factor components for deformation and energy dissipation capacity and for overstrength due to the redistribution of forces are derived by means of pushover analyses. Furthermore, considerations on the behaviour factor component due to other sources of overstrength in masonry buildings are presented. As a result of the investigations, rationally based values of the behaviour factor q to be used in linear analyses in the range of 2.0–3.0 are proposed.
The article presents the investigation of the seismic behaviour of a modern URM building located in the municipality of Finale Emilia in province of Modena, Northern Italy. The building is situated in the centre of the series of the 2012 Northern Italy earthquakes and has not suffered any damage during the earthquake series in 2012. The observed earthquake resistance of the building is compared with predicted resistances based on linear and nonlinear design approaches according to Eurocode. Furthermore, probabilistic analyses based on nonlinear calculation models taking into account scattering of the most relevant input parameters are carried out to identify their influence to the results and to derive fragility curves.
Investigation of the InSb(110)-Sn schottky barrier by means of electron energy loss spectroscopy
(1987)
The sandfish (Scincus scincus) is a lizard having the remarkable ability to move through desert sand for significant distances. It is well adapted to living in loose sand by virtue of a combination of morphological and behavioural specializations. We investigated the bodyform of the sandfish using 3D-laserscanning and explored its locomotion in loose desert sand using fast nuclear magnetic resonance (NMR) imaging. The sandfish exhibits an in-plane meandering motion with a frequency of about 3 Hz and an amplitude of about half its body length accompanied by swimming-like (or trotting) movements of its limbs. No torsion of the body was observed, a movement required for a digging-behaviour. Simple calculations based on the Janssen model for granular material related to our findings on bodyform and locomotor behaviour render a local decompaction of the sand surrounding the moving sandfish very likely. Thus the sand locally behaves as a viscous fluid and not as a solid material. In this fluidised sand the sandfish is able to “swim” using its limbs.
Influence of slab deflection on the out-of-plane capacity of unreinforced masonry partition walls
(2023)
Severe damage of non-structural elements is noticed in previous earthquakes, causing high economic losses and posing a life threat for the people. Masonry partition walls are one of the most commonly used non-structural elements. Therefore, their behaviour under earthquake loading in out-of-plane (OOP) direction is investigated by several researches in the past years. However, none of the existing experimental campaigns or analytical approaches consider the influence of prior slab deflection on OOP response of partition walls. Moreover, none of the existing construction techniques for the connection of partition walls with surrounding reinforced concrete (RC) is investigated for the combined slab deflection and OOP loading. However, the inevitable time-dependent behaviour of RC slabs leads to high values of final slab deflections which can further influence boundary conditions of partition walls. Therefore, a comprehensive study on the influence of slab deflection on the OOP capacity of masonry partitions is conducted. In the first step, experimental tests are carried out. Results of experimental tests are further used for the calibration of the numerical model employed for a parametric study. Based on the results, behaviour under combined loading for different construction techniques is explained. The results show that slab deflection leads either to severe damage or to a high reduction of OOP capacity. Existing practical solutions do not account for these effects. In this contribution, recommendations to overcome the problems of combined slab deflection and OOP loading on masonry partition walls are given. Possible interaction of in-plane (IP) loading, with the combined slab deflection and OOP loading on partition walls, is not investigated in this study.
Cross sections for neutron-induced reactions of short-lived nuclei are essential for nuclear astrophysics since these reactions in the stars are responsible for the production of most heavy elements in the universe. These reactions are also key in applied domains like energy production and medicine. Nevertheless, neutron-induced cross-section measurements can be extremely challenging or even impossible to perform due to the radioactivity of the targets involved. Indirect measurements through the surrogate-reaction method can help to overcome these difficulties.
The surrogate-reaction method relies on the use of an alternative reaction that will lead to the formation of the same excited nucleus as in the neutron-induced reaction of interest. The decay probabilities (for fission, neutron and gamma-ray emission) of the nucleus produced via the surrogate reaction allow one to constrain models and the prediction of the desired neutron cross sections.
We propose to perform surrogate reaction measurements in inverse kinematics at heavy-ion storage rings, in particular at the CRYRING@ESR of the GSI/FAIR facility. We present the conceptual idea of the most promising setup to measure for the first time simultaneously the fission, neutron and gamma-ray emission probabilities. The results of the first simulations considering the 238U(d,d') reaction are shown, as well as new technical developments that are being carried out towards this set-up.
Heat production in the windings of the stators of electric machines under stationary condition
(2014)
In electric machines due to high currents and resistive losses (joule heating) heat is produced. To avoid damages by overheating the design of effective cooling systems is required. Therefore the knowledge of heat sources and heat transfer processes is necessary. The purpose of this paper is to illustrate a good and effective calculation method for the temperature analysis based on homogenization techniques. These methods have been applied for the stator windings in a slot of an electric machine consisting of copper wires and resin. The key quantity here is an effective thermal conductivity, which characterizes the heterogeneous wire resin-arrangement inside the stator slot. To illustrate the applicability of the method, the analysis of a simplified, homogenized model is compared with the detailed analysis of temperature behavior inside a slot of an electric machine according to the heat generation. We considered here only the stationary situation. The achieved numerical results are accurate and show that the applied homogenization technique works in practice. Finally the results of simulations for the two cases, the original model of the slot and the homogenized model chosen for the slot (unit cell), are compared to experimental results.
Future evolution of risk management for structures : Advancement for the future IEC 62305-2 Ed3
(2011)
Fast, Automated Testing of Different Air Filter Media / Mölter, W. ; Helsper, C. ; Kaminski, S.
(1992)
Fast and Automated Testing of Different Air Filter Media / Mölter, W. ; Helsper, C. ; Kaminski, S.
(1989)
Fast and Automated Testing of Different Air Filter Media / Mölter, W. ; Helsper, C. ; Kaminski, S.
(1989)
Because of simple construction process, high energy efficiency, significant fire resistance and excellent sound isolation, masonry infilled reinforced concrete (RC) frame structures are very popular in most of the countries in the world, as well as in seismic active areas. However, many RC frame structures with masonry infills were seriously damaged during earthquake events, as the traditional infills are generally constructed with direct contact to the RC frame which brings undesirable infill/frame interaction. This interaction leads to the activation of the equivalent diagonal strut in the infill panel, due to the RC frame deformation, and combined with seismically induced loads perpendicular to the infill panel often causes total collapses of the masonry infills and heavy damages to the RC frames. This fact was the motivation for developing different approaches for improving the behaviour of masonry infills, where infill isolation (decoupling) from the frame has been more intensively studied in the last decade. In-plane isolation of the infill wall reduces infill activation, but causes the need for additional measures to restrain out-of-plane movements. This can be provided by installing steel anchors, as proposed by some researchers. Within the framework of European research project INSYSME (Innovative Systems for Earthquake Resistant Masonry Enclosures in Reinforced Concrete Buildings) the system based on a use of elastomers for in-plane decoupling and steel anchors for out-of-plane restrain was tested. This constructive solution was tested and deeply investigated during the experimental campaign where traditional and decoupled masonry infilled RC frames with anchors were subjected to separate and combined in-plane and out-of-plane loading. Based on a detailed evaluation and comparison of the test results, the performance and effectiveness of the developed system are illustrated.
Evaluation of Particle Size Distributions by Means of Particle Counters / Fißan, H. J. ; Helsper, C.
(1979)
Evaluation of dopant profiles and diffusion constants by means of electron energy loss spectroscopy
(1989)
Erzeugung von Prüfaerosolen für die Kalibrierung von optischen Partikelmeßverfahren nach VDI 3491
(1989)
The 2012 Emilia-Romagna earthquake, that mainly struck the homonymous Italian region provoking 28 casualties and damage to thousands of structures and infrastructures, is an exceptional source of information to question, investigate, and challenge the validity of seismic fragility functions and loss curves from an empirical standpoint. Among the most recent seismic events taking place in Europe, that of Emilia-Romagna is quite likely one of the best documented, not only in terms of experienced damages, but also for what concerns occurred losses and necessary reconstruction costs. In fact, in order to manage the compensations in a fair way both to citizens and business owners, soon after the seismic sequence, the regional administrative authority started (1) collecting damage and consequence-related data, (2) evaluating information sources and (3) taking care of the cross-checking of various reports. A specific database—so-called Sistema Informativo Gestione Europa (SFINGE)—was devoted to damaged business activities. As a result, 7 years after the seismic events, scientists can rely on a one-of-a-kind, vast and consistent database, containing information about (among other things): (1) buildings’ location and dimensions, (2) occurred structural damages, (3) experienced direct economic losses and (4) related reconstruction costs. The present work is focused on a specific data subset of SFINGE, whose elements are Long-Span-Beam buildings (mostly precast) deployed for business activities in industry, trade or agriculture. With the available set of data, empirical fragility functions, cost and loss ratio curves are elaborated, that may be included within existing Performance Based Earthquake Engineering assessment toolkits.
In many cities, diesel buses are being replaced by electric buses with the aim of reducing local emissions and thus improving air quality. The protection of the environment and the health of the population is the highest priority of our society. For the transport companies that operate these buses, not only ecological issues but also economic issues are of great importance. Due to the high purchase costs of electric buses compared to conventional buses, operators are forced to use electric vehicles in a targeted manner in order to ensure amortization over the service life of the vehicles. A compromise between ecology and economy must be found in order to both protect the environment and ensure economical operation of the buses.
In this study, we present a new methodology for optimizing the vehicles’ charging time as a function of the parameters CO₂eq emissions and electricity costs. Based on recorded driving profiles in daily bus operation, the energy demands of conventional and electric buses are calculated for the passenger transportation in the city of Aachen in 2017. Different charging scenarios are defined to analyze the influence of the temporal variability of CO₂eq intensity and electricity price on the environmental impact and economy of the bus. For every individual day of a year, charging periods with the lowest and highest costs and emissions are identified and recommendations for daily bus operation are made. To enable both the ecological and economical operation of the bus, the parameters of electricity price and CO₂ are weighted differently, and several charging periods are proposed, taking into account the priorities previously set. A sensitivity analysis is carried out to evaluate the influence of selected parameters and to derive recommendations for improving the ecological and economic balance of the battery-powered electric vehicle.
In all scenarios, the optimization of the charging period results in energy cost savings of a maximum of 13.6% compared to charging at a fixed electricity price. The savings potential of CO₂eq emissions is similar, at 14.9%. From an economic point of view, charging between 2 a.m. and 4 a.m. results in the lowest energy costs on average. The CO₂eq intensity is also low in this period, but midday charging leads to the largest savings in CO₂eq emissions. From a life cycle perspective, the electric bus is not economically competitive with the conventional bus. However, from an ecological point of view, the electric bus saves on average 37.5% CO₂eq emissions over its service life compared to the diesel bus. The reduction potential is maximized if the electric vehicle exclusively consumes electricity from solar and wind power.
E0 transitions in 106Pd studied by neutron capture / G. G. Colvin ; F. Hoyler ; S. J. Robinson
(1987)
Contemporary research appreciates a diverse workforce as a potential source of innovation. Researchers explore the fine details of why diversity management is central for generating innovations in heterogeneous research groups and how it could be effectively implemented into organizations. Complex research associations that discuss topics with a high impact on society increasingly address the necessity of establishing a diverse workforce to confront the challenges of tomorrow. Characterized by complex management structures as well as hierarchies, research associations have not been a subject of investigation until now. For this reason, the presented research project aims to develop a diversity and innovation management strategy with the ultimate goal of inducing change in the corporate culture. The proposed approach consisted of six phases; the first two phases investigated the status quo of diversity in the existing organizational structures of member institutes and the variety of particular working cultures within the research association. The third and the fourth phases utilized qualitative and quantitative studies. The third phase focused on the connection of management level to diversity and innovation, and the need for diversity and innovation management, and tailor-made methods of implementing them. The first three phases have been accomplished successfully; preliminary results are already available. The fourth phase will mainly focus on exploring the mind-set of the employees. The fifth phase will consolidate the findings in the first four phases into an implementable strategy. The final phase will address the implementation of this strategy into the organization. Phases 4 to 6 have not yet been undertaken