Refine
Year of publication
- 2024 (22)
- 2023 (77)
- 2022 (122)
- 2021 (127)
- 2020 (154)
- 2019 (191)
- 2018 (165)
- 2017 (153)
- 2016 (150)
- 2015 (162)
- 2014 (159)
- 2013 (168)
- 2012 (152)
- 2011 (178)
- 2010 (173)
- 2009 (175)
- 2008 (148)
- 2007 (137)
- 2006 (129)
- 2005 (122)
- 2004 (150)
- 2003 (95)
- 2002 (123)
- 2001 (103)
- 2000 (102)
- 1999 (109)
- 1998 (98)
- 1997 (96)
- 1996 (81)
- 1995 (78)
- 1994 (86)
- 1993 (59)
- 1992 (54)
- 1991 (29)
- 1990 (39)
- 1989 (44)
- 1988 (56)
- 1987 (32)
- 1986 (19)
- 1985 (33)
- 1984 (22)
- 1983 (20)
- 1982 (29)
- 1981 (20)
- 1980 (36)
- 1979 (24)
- 1978 (34)
- 1977 (14)
- 1976 (13)
- 1975 (12)
- 1974 (3)
- 1973 (2)
- 1972 (2)
- 1971 (1)
- 1968 (1)
Document Type
- Article (3149)
- Conference Proceeding (1016)
- Part of a Book (184)
- Book (144)
- Doctoral Thesis (30)
- Patent (25)
- Other (9)
- Report (9)
- Preprint (4)
- Poster (3)
- Talk (3)
- Master's Thesis (2)
- Working Paper (2)
- Bachelor Thesis (1)
- Contribution to a Periodical (1)
- Habilitation (1)
Language
- English (4583) (remove)
Has Fulltext
- no (4583) (remove)
Keywords
- Gamification (6)
- avalanche (6)
- Earthquake (5)
- Enterprise Architecture (5)
- MINLP (5)
- solar sail (5)
- Diversity Management (4)
- Energy storage (4)
- Engineering optimization (4)
- LAPS (4)
- Natural language processing (4)
- Papierkunst (4)
- Power plants (4)
- Seismic design (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- hydrogen (4)
- metal structure (4)
- snow (4)
- steel (4)
Institute
- Fachbereich Medizintechnik und Technomathematik (1545)
- Fachbereich Elektrotechnik und Informationstechnik (686)
- IfB - Institut für Bioengineering (560)
- Fachbereich Energietechnik (552)
- INB - Institut für Nano- und Biotechnologien (532)
- Fachbereich Chemie und Biotechnologie (522)
- Fachbereich Luft- und Raumfahrttechnik (463)
- Fachbereich Maschinenbau und Mechatronik (261)
- Fachbereich Wirtschaftswissenschaften (196)
- Solar-Institut Jülich (160)
- Fachbereich Bauingenieurwesen (146)
- ECSM European Center for Sustainable Mobility (75)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (62)
- Fachbereich Gestaltung (24)
- Nowum-Energy (24)
- Institut fuer Angewandte Polymerchemie (23)
- Sonstiges (21)
- Fachbereich Architektur (20)
- Freshman Institute (18)
- Kommission für Forschung und Entwicklung (18)
Diffusion in simple fluids / R. J. Speedy; F. X. Prielmeier; T. Vardag; E. W. Lang; H.-D. Lüdemann
(1989)
Many biped robots deploy a form of gait that follows the zero moment point (ZMP) approach, that is, the robot is in a stable position at any point in time. This requires the robot to be fully actuated. While very stable, the draw-backs of this approach are a fairly slow gait and high energy consumption. An alternative approach is the so-called passive-dynamic walking, where the gait makes use of the inertia and dynamic stability of the robot. In this paper we describe our ongoing work of combining the principles of passive-dynamic walking on the fully-actuated biped robot Nao, which is also deployed for robotic soccer applications. We present a simple controller that allows the robot to stably rock sidewards, showing a closed limit-cycle. We discuss first results of superimposing a forward motion on the sidewards motion. Based on this we expect to endow the Nao with a fast, robust, and stable passive-dynamic walk on the fully-actuated Nao in the future.
Hollow core fiber delivery of sub-ps pulses from a TruMicro 5000 Femto edition thin disk amplifier
(2015)
Patients after coarctation repair still have an increased risk of cardiovascular or cerebrovascular events. This has been explained by the persisting hypertension and alterations in the peripheral vessels. However, involvement of the central vessels such as the retinal arteries is virtually unknown. A total of 34 patients after coarctation repair (22 men and 12 women; 23 to 58 years old, age range 0 to 32 years at surgical repair) and 34 nonhypertensive controls underwent structural and functional retinal vessel analysis. Using structural analysis, the vessel diameters were measured. Using functional analysis, the endothelium-dependent vessel dilation in response to flicker light stimulation was assessed. In the patients after coarctation repair, the retinal arteriolar diameter was significantly reduced compared to that of the controls (median 182 μm, first to third quartile 171 to 197; vs 197 μm, first to third quartile 193 to 206; p <0.001). These findings were independent of the peripheral blood pressure and age at intervention. No differences were found for venules. The functional analysis findings were not different between the patients and controls (maximum dilation 3.5%, first to third quartile 2.1% to 4.5% vs 3.6%, first to third quartile 2.2% to 4.3%; p = 0.81), indicating preserved autoregulative mechanisms. In conclusion, the retinal artery diameter is reduced in patients after coarctation repair, independent of their current blood pressure level and age at intervention. As a structural marker of chronic vessel damage associated with past, current, or future hypertension, retinal arteriolar narrowing has been linked to stroke incidence. These results indicate an involvement of cerebral microcirculation in aortic coarctation, despite timely repair, and might contribute to explain the increased rate of cerebrovascular events in such patients.
Frequency mixing magnetic detection (FMMD) has been widely utilized as a measurement technique in magnetic immunoassays. It can also be used for the characterization and distinction (also known as “colourization”) of different types of magnetic nanoparticles (MNPs) based on their core sizes. In a previous work, it was shown that the large particles contribute most of the FMMD signal. This leads to ambiguities in core size determination from fitting since the contribution of the small-sized particles is almost undetectable among the strong responses from the large ones. In this work, we report on how this ambiguity can be overcome by modelling the signal intensity using the Langevin model in thermodynamic equilibrium including a lognormal core size distribution fL(dc,d0,σ) fitted to experimentally measured FMMD data of immobilized MNPs. For each given median diameter d0, an ambiguous amount of best-fitting pairs of parameters distribution width σ and number of particles Np with R2 > 0.99 are extracted. By determining the samples’ total iron mass, mFe, with inductively coupled plasma optical emission spectrometry (ICP-OES), we are then able to identify the one specific best-fitting pair (σ, Np) one uniquely. With this additional externally measured parameter, we resolved the ambiguity in core size distribution and determined the parameters (d0, σ, Np) directly from FMMD measurements, allowing precise MNPs sample characterization.
Frequency mixing magnetic detection (FMMD) has been explored for its applications in fields of magnetic biosensing, multiplex detection of magnetic nanoparticles (MNP) and the determination of core size distribution of MNP samples. Such applications rely on the application of a static offset magnetic field, which is generated traditionally with an electromagnet. Such a setup requires a current source, as well as passive or active cooling strategies, which directly sets a limitation based on the portability aspect that is desired for point of care (POC) monitoring applications. In this work, a measurement head is introduced that involves the utilization of two ring-shaped permanent magnets to generate a static offset magnetic field. A steel cylinder in the ring bores homogenizes the field. By variation of the distance between the ring magnets and of the thickness of the steel cylinder, the magnitude of the magnetic field at the sample position can be adjusted. Furthermore, the measurement setup is compared to the electromagnet offset module based on measured signals and temperature behavior.