Refine
Year of publication
- 2024 (135)
- 2023 (258)
- 2022 (303)
- 2021 (293)
- 2020 (245)
- 2019 (385)
- 2018 (262)
- 2017 (262)
- 2016 (284)
- 2015 (301)
- 2014 (302)
- 2013 (301)
- 2012 (333)
- 2011 (329)
- 2010 (343)
- 2009 (369)
- 2008 (312)
- 2007 (312)
- 2006 (330)
- 2005 (303)
- 2004 (323)
- 2003 (254)
- 2002 (250)
- 2001 (221)
- 2000 (245)
- 1999 (236)
- 1998 (242)
- 1997 (220)
- 1996 (202)
- 1995 (192)
- 1994 (175)
- 1993 (155)
- 1992 (144)
- 1991 (100)
- 1990 (108)
- 1989 (111)
- 1988 (104)
- 1987 (105)
- 1986 (81)
- 1985 (84)
- 1984 (75)
- 1983 (70)
- 1982 (57)
- 1981 (54)
- 1980 (61)
- 1979 (58)
- 1978 (52)
- 1977 (32)
- 1976 (30)
- 1975 (28)
- 1974 (17)
- 1973 (12)
- 1972 (17)
- 1971 (11)
- 1970 (2)
- 1969 (2)
- 1968 (2)
- 1967 (1)
- 1963 (1)
- 1925 (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (2077)
- Fachbereich Elektrotechnik und Informationstechnik (1184)
- Fachbereich Wirtschaftswissenschaften (1164)
- Fachbereich Energietechnik (1115)
- Fachbereich Chemie und Biotechnologie (914)
- Fachbereich Maschinenbau und Mechatronik (876)
- Fachbereich Luft- und Raumfahrttechnik (798)
- Fachbereich Bauingenieurwesen (711)
- IfB - Institut für Bioengineering (690)
- INB - Institut für Nano- und Biotechnologien (617)
Language
- German (5133)
- English (4929)
- Russian (14)
- Portuguese (6)
- Italian (5)
- Multiple languages (5)
- Spanish (3)
- Dutch (2)
Document Type
- Article (5658)
- Conference Proceeding (1650)
- Book (1083)
- Part of a Book (571)
- Bachelor Thesis (327)
- Patent (176)
- Report (102)
- Doctoral Thesis (80)
- Other (76)
- Administrative publication (76)
Keywords
- Amtliche Mitteilung (71)
- Bachelor (33)
- Aachen University of Applied Sciences (31)
- Master (31)
- Prüfungsordnung (31)
- Bauingenieurwesen (30)
- Lesbare Fassung (28)
- Biosensor (25)
- Fachhochschule Aachen (23)
- Illustration (23)
Zugriffsart
- campus (2151)
- weltweit (1884)
- bezahl (773)
- fachbereichsweit (FB4) (34)
The application of atomic layer deposition in the production of sorbents for ⁹⁹Mo/⁹⁹ᵐTc generator
(2020)
New production routes for ⁹⁹Mo are steadily gaining importance. However, the obtained specific activity is much lower than currently produced by the fission of U-235. To be able to supply hospitals with ⁹⁹Mo/⁹⁹ᵐTc generators with the desired activity, the adsorption capacity of the column material should be increased. In this paper we have investigated whether the gas phase coating technique Atomic Layer Deposition (ALD), which can deposit ultra-thin layers on high surface area materials, can be used to attain materials with high adsorption capacity for ⁹⁹Mo. For this purpose, ALD was applied on a silica-core sorbent material to coat it with a thin layer of alumina. This sorbent material shows to have a maximum adsorption capacity of 120 mg/g and has a ⁹⁹ᵐTc elution efficiency of 55 ± 2% based on 3 executive elutions.
The Atmospheric Remote-Sensing Infrared Exoplanet Large-survey, ARIEL, has been selected to be the next (M4) medium class space mission in the ESA Cosmic Vision programme. From launch in 2028, and during the following 4 years of operation, ARIEL will perform precise spectroscopy of the atmospheres of ~1000 known transiting exoplanets using its metre-class telescope. A three-band photometer and three spectrometers cover the 0.5 µm to 7.8 µm region of the electromagnetic spectrum. This paper gives an overview of the mission payload, including the telescope assembly, the FGS (Fine Guidance System) - which provides both pointing information to the spacecraft and scientific photometry and low-resolution spectrometer data, the ARIEL InfraRed Spectrometer (AIRS), and other payload infrastructure such as the warm electronics, structures and cryogenic cooling systems.
With proven impact of statistical fracture analysis on fracture classifications, it is desirable to minimize the manual work and to maximize repeatability of this approach. We address this with an algorithm that reduces the manual effort to segmentation, fragment identification and reduction. The fracture edge detection and heat map generation are performed automatically. With the same input, the algorithm always delivers the same output. The tool transforms one intact template consecutively onto each fractured specimen by linear least square optimization, detects the fragment edges in the template and then superimposes them to generate a fracture probability heat map.
We hypothesized that the algorithm runs faster than the manual evaluation and with low (< 5 mm) deviation. We tested the hypothesis in 10 fractured proximal humeri and found that it performs with good accuracy (2.5 mm ± 2.4 mm averaged Euclidean distance) and speed (23 times faster). When applied to a distal humerus, a tibia plateau, and a scaphoid fracture, the run times were low (1–2 min), and the detected edges correct by visual judgement. In the geometrically complex acetabulum, at a run time of 78 min some outliers were considered acceptable. An automatically generated fracture probability heat map based on 50 proximal humerus fractures matches the areas of high risk of fracture reported in medical literature.
Such automation of the fracture analysis method is advantageous and could be extended to reduce the manual effort even further.
The continuously growing amount of renewable sources starts compromising the stability of electrical grids. Contradictory to fossil fuel power plants, energy production of wind and photovoltaic (PV) energy is fluctuating. Although predictions have significantly improved, an outage of multi-MW offshore wind farms poses a challenging problem. One solution could be the integration of storage systems in the grid. After a short overview, this paper focuses on two exemplary battery storage systems, including the required power electronics. The grid integration, as well as the optimal usage of volatile energy reserves, is presented for a 5- kW PV system for home application, as well as for a 100- MW medium-voltage system, intended for wind farm usage. The efficiency and cost of topologies are investigated as a key parameter for large-scale integration of renewable power at medium- and low-voltage.
The Carologistics team participates in the RoboCup Logistics League for the seventh year. The RCLL requires precise vision,
manipulation and path planning, as well as complex high-level decision
making and multi-robot coordination. We outline our approach with an
emphasis on recent modifications to those components.
The team members in 2018 are David Bosen, Christoph Gollok, Mostafa
Gomaa, Daniel Habering, Till Hofmann, Nicolas Limpert, Sebastian Schönitz,
Morian Sonnet, Carsten Stoffels, and Tarik Viehmann.
This paper is based on the last year’s team description.
The case for a more binding WTO agreement on regulatory principles in telecommunication markets
(1999)
Within the Crystal Clear Collaboration a modular system for a small animal PET scanner (ClearPET™) has been developed. The modularity allows the assembly of scanners of different sizes and characteristics in order to fit the specific needs of the individual member institutions. Now a first demonstrator is being completed in Julich. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to multi-channel photomultipliers (PMTs). A free-running ADC digitizes the signal from the PMT and the complete scintillation pulses are sampled by an FPGA and sent with 20 MB/S to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. An advantage of that is that the coincidence window and the dimensions of the field of view can be adjusted easily. The ClearPET™ demonstrator is equipped with 10240 crystals on 80 PMTs. This paper presents an overview of the data acquisition system.
The ClearPET project
(2004)
The Crystal Clear Collaboration has designed and is building a high-resolution small animal PET scanner. The design is based on the use of the Hamamatsu R7600-M64 multi-anode photomultiplier tube and a LSO/LuYAP phoswich matrix with one to one coupling between the crystals and the photo-detector. The complete system will have 80 PM tubes in four rings with an inner diameter of 137 mm and an axial field of view of 110 mm. The PM pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. Simulations, and measurements a 2×4 module test set-up predict a spatial resolution of 1.5 mm in the centre of the field of view and a sensitivity of 5.9% for a point source in the centre of the field of view.
A 2nd generation high performance small animal PET scanner, called ClearPET™, has been designed and a first prototype is built by working groups of the Crystal Clear Collaboration (CCC). In order to achieve high sensitivity and maintain good uniform spatial resolution over the field of view in high resolution PET systems, it is necessary to extract the depth of interaction (DOI) information and correct for spatial degradation. The design of the first ClearPET™ Demonstrator based on the use of the multi-anode photomultiplier tube (Hamamatsu R7600-M64) and a LSO/LuYAP phoswich matrix. The two crystal layers of 8*8 crystals (2*2*10 mm3) are stacked on each other and mounted without light guide as one to one on the PMT. A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the crystal ring is 137 mm, the axial detector length is 110 mm. The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. The measurements have been done using the first LSO/LuYAP detector cassettes.