Refine
Year of publication
- 2024 (93)
- 2023 (186)
- 2022 (234)
- 2021 (229)
- 2020 (232)
- 2019 (301)
- 2018 (252)
- 2017 (255)
- 2016 (260)
- 2015 (284)
- 2014 (280)
- 2013 (285)
- 2012 (313)
- 2011 (310)
- 2010 (331)
- 2009 (341)
- 2008 (290)
- 2007 (271)
- 2006 (276)
- 2005 (263)
- 2004 (286)
- 2003 (218)
- 2002 (232)
- 2001 (210)
- 2000 (234)
- 1999 (232)
- 1998 (236)
- 1997 (214)
- 1996 (200)
- 1995 (192)
- 1994 (174)
- 1993 (154)
- 1992 (144)
- 1991 (100)
- 1990 (108)
- 1989 (110)
- 1988 (103)
- 1987 (105)
- 1986 (81)
- 1985 (83)
- 1984 (75)
- 1983 (70)
- 1982 (57)
- 1981 (54)
- 1980 (61)
- 1979 (58)
- 1978 (52)
- 1977 (32)
- 1976 (30)
- 1975 (28)
- 1974 (17)
- 1973 (12)
- 1972 (17)
- 1971 (11)
- 1970 (2)
- 1969 (2)
- 1968 (2)
- 1967 (1)
- 1963 (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (1928)
- Fachbereich Elektrotechnik und Informationstechnik (1150)
- Fachbereich Wirtschaftswissenschaften (1119)
- Fachbereich Energietechnik (1066)
- Fachbereich Chemie und Biotechnologie (892)
- Fachbereich Maschinenbau und Mechatronik (801)
- Fachbereich Luft- und Raumfahrttechnik (769)
- Fachbereich Bauingenieurwesen (664)
- IfB - Institut für Bioengineering (627)
- INB - Institut für Nano- und Biotechnologien (585)
Has Fulltext
- no (9284) (remove)
Language
Document Type
- Article (5518)
- Conference Proceeding (1413)
- Book (1057)
- Part of a Book (555)
- Patent (174)
- Bachelor Thesis (169)
- Report (82)
- Doctoral Thesis (79)
- Conference: Meeting Abstract (75)
- Other (67)
Keywords
- Illustration (10)
- Nachhaltigkeit (10)
- Corporate Design (9)
- Erscheinungsbild (8)
- Gamification (8)
- Redesign (7)
- Animation (6)
- Datenschutz (6)
- Deutschland (6)
- Digitalisierung (6)
Speicher statt Kohle. Integration thermischer Stromspeicher in vorhandene Kraftwerksstandorte
(2019)
Improved efficiency prediction of a molten salt receiver based on dynamic cloud passage simulation
(2019)
Die steigende Popularität von mobilen Endgeräten im privaten und geschäftlichen Umfeld geht mit einem Anstieg an Sicherheitslücken und somit potentiellen Angriffsflächen einher. Als ein Element der technischen und organisatorischen Maßnahmen zum Schutz eines Netzwerkes können Monitoring-Apps dienen, die unerwünschtes Verhalten und Angriffe erkennen. Die automatisierte Überwachung von Endgeräten ist jedoch rechtlich und ethisch komplex. Dies in Kombination mit einer hohen Sensibilität der Nutzer und Nutzerinnen dieser Geräte in Bezug auf Privatsphäre, kann zu einer geringen Akzeptanz und Compliance führen. Eine datenschutzrechtlich und ethisch einwandfreie Konzeption solcher Apps bereits im Designprozess führt zu höherer Akzeptanz und verbessert so die Effizienz. Diese Analyse beschreibt Möglichkeiten zur Umsetzung.
Baumaschinen
(2019)
Kurz vor der parlamentarischen Sommerpause hat der Bundestag am 28.6.2019 das 2. Datenschutz-Anpassungs- und Umsetzungsgesetz EU (2. DSAnpUG-EU) beschlossen, der Bundesrat hat diesem Gesetz am 20.9.2019 zugestimmt. Das Artikelgesetz, welches im sog. Omnibusverfahren zahlreiche Gesetze auf Bundesebene ändert, soll zur Vereinheitlichung und Anpassung des Bundesrechts an die seit Mai 2018 geltende Datenschutz-Grundverordnung (DSGVO) beitragen.
Sensitive and rapid detection of cholera toxin subunit B using magnetic frequency mixing detection
(2019)
Cholera is a life-threatening disease caused by the cholera toxin (CT) as produced by some Vibrio cholerae serogroups. In this research we present a method which directly detects the toxin’s B subunit (CTB) in drinking water. For this purpose we performed a magnetic sandwich immunoassay inside a 3D immunofiltration column. We used two different commercially available antibodies to capture CTB and for binding to superparamagnetic beads. ELISA experiments were performed to select the antibody combination. The beads act as labels for the magnetic frequency mixing detection technique. We show that the limit of detection depends on the type of magnetic beads. A nonlinear Hill curve was fitted to the calibration measurements by means of a custom-written python software. We achieved a sensitive and rapid detection of CTB within a broad concentration range from 0.2 ng/ml to more
than 700 ng/ml.
The movement of magnetic beads due to a magnetic field gradient is of great interest in different application fields. In this report we present a technique based on a magnetic tweezers setup to measure the velocity factor of magnetically actuated individual superparamagnetic beads in a fluidic environment. Several beads can be tracked simultaneously in order to gain and improve statistics. Furthermore we show our results for different beads with hydrodynamic diameters between 200 and 1000 nm from diverse manufacturers. These measurement data can, for example, be used to determine design parameters for a magnetic separation system, like maximum flow rate and minimum separation time, or to select suitable beads for fixed experimental requirements.
Kalkulation
(2019)
In modern bioanalytical methods, it is often desired to detect several targets in one sample within one measurement. Immunological methods including those that use superparamagnetic beads are an important group of techniques for these applications. The goal of this work is to investigate the feasibility of simultaneously detecting different superparamagnetic beads acting as markers using the magnetic frequency mixing technique. The frequency of the magnetic excitation field is scanned while the lower driving frequency is kept constant. Due to the particles’ nonlinear magnetization, mixing frequencies are generated. To record their amplitude and phase information, a direct digitization of the pickup-coil’s signal with subsequent Fast Fourier Transformation is performed. By synchronizing both magnetic beads using frequency scanning in magnetic frequency mixing technique magnetic fields, a stable phase information is gained. In this research, it is shown that the amplitude of the dominant mixing component is proportional to the amount of superparamagnetic beads inside a sample. Additionally, it is shown that the phase does not show this behaviour. Excitation frequency scans of different bead types were performed, showing different phases, without correlation to their diverse amplitudes. Two commercially available beads were selected and a determination of their amount in a mixture is performed as a demonstration for multiplex measurements.