Conference Proceeding
Refine
Year of publication
Document Type
- Conference Proceeding (1393) (remove)
Has Fulltext
- no (1393) (remove)
Keywords
- Enterprise Architecture (5)
- Gamification (5)
- Energy storage (4)
- Natural language processing (4)
- Power plants (4)
- hydrogen (4)
- solar sail (4)
- Associated liquids (3)
- Concentrated solar power (3)
- Hybrid energy system (3)
- MASCOT (3)
- Out-of-plane load (3)
- Serious Game (3)
- earthquakes (3)
- Additive manufacturing (2)
- Adjacent buildings (2)
- BIM (2)
- Case Study (2)
- Clustering (2)
- Deep learning (2)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (280)
- Fachbereich Energietechnik (226)
- Fachbereich Luft- und Raumfahrttechnik (192)
- Fachbereich Maschinenbau und Mechatronik (188)
- Solar-Institut Jülich (164)
- Fachbereich Medizintechnik und Technomathematik (148)
- IfB - Institut für Bioengineering (113)
- Fachbereich Bauingenieurwesen (101)
- ECSM European Center for Sustainable Mobility (57)
- Fachbereich Wirtschaftswissenschaften (53)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (44)
- INB - Institut für Nano- und Biotechnologien (41)
- Fachbereich Chemie und Biotechnologie (33)
- Nowum-Energy (22)
- Kommission für Forschung und Entwicklung (16)
- Fachbereich Architektur (13)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (8)
- Fachbereich Gestaltung (3)
- IaAM - Institut für angewandte Automation und Mechatronik (3)
- Institut fuer Angewandte Polymerchemie (2)
- Verwaltung (2)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
- Digitalisierung in Studium & Lehre (1)
- FH Aachen (1)
- Freshman Institute (1)
Existing residential buildings have an average lifetime of 100 years. Many of these buildings will exist for at least another 50 years. To increase the efficiency of these buildings while keeping costs at reasonable rates, they can be retrofitted with sensors that deliver information to central control units for heating, ventilation and electricity. This retrofitting process should happen with minimal intervention into existing infrastructure and requires new approaches for sensor design and data transmission. At FH Aachen University of Applied Sciences, students of different disciplines work together to learn how to design, build, deploy and operate such sensors. The presented teaching project already created a low power design for a combined CO2, temperature and humidity measurement device that can be easily integrated into most home automation systems
Sensor positioning and thermal model for condition monitoring of pressure gas reservoirs in vehicles
(2018)
Sensitivity of phase detection techniques in aerated chute flows to hydraulic design parameters
(2012)
Sensitivity Analysis of General Aviation Aircraft with Parallel Hybrid-Electric Propulsion Systems
(2019)
A methodology for assessment, seismic verification and strengthening of existing masonry buildings is presented in this paper. The verification is performed using a calculation model calibrated with the results from ambient vibration measurements. The calibrated model serves as an input for a deformation-based verification procedure based on the Capacity Spectrum Method (CSM). The bearing capacity of the building is calculated from experimental capacity curves of the individual walls idealized with bilinear elastic-perfectly plastic curves. The experimental capacity curves were obtained from in-plane cyclic loading tests on unreinforced and strengthened masonry walls with reinforced concrete jackets. The seismic action is compared with the load-bearing capacity of the building considering non-linear material behavior with its post-peak capacity. The application of the CSM to masonry buildings and the influence of a traditional strengthening method are demonstrated on the example of a public school building in Skopje, Macedonia.
In many historical centres in Europe, stone masonry buildings are part of building aggregates, which developed when the layout of the city or village was densified. In these aggregates, adjacent buildings share structural walls to support floors and roofs. Meanwhile, the masonry walls of the façades of adjacent buildings are often connected by dry joints since adjacent buildings were constructed at different times. Observations after for example the recent Central Italy earthquakes showed that the dry joints between the building units were often the first elements to be damaged. As a result, the joints opened up leading to pounding between the building units and a complicated interaction at floor and roof beam supports. The analysis of such building aggregates is very challenging and modelling guidelines do not exist. Advances in the development of analysis methods have been impeded by the lack of experimental data on the seismic response of such aggregates. The objective of the project AIMS (Seismic Testing of Adjacent Interacting Masonry Structures), included in the H2020 project SERA, is to provide such experimental data by testing an aggregate of two buildings under two horizontal components of dynamic
excitation. The test unit is built at half-scale, with a two-storey building and a one-storey building. The buildings share one common wall while the façade walls are connected by dry joints. The floors are at different heights leading to a complex dynamic response of this smallest possible building aggregate. The shake table test is conducted at the LNEC seismic testing facility. The testing sequence comprises four levels of shaking: 25%, 50%, 75% and 100% of nominal shaking table capacity. Extensive instrumentation, including accelerometers, displacement transducers and optical measurement systems, provides detailed information on the building aggregate response. Special attention is paid to the interface opening, the globa