Article
Refine
Year of publication
Document Type
- Article (3226) (remove)
Language
- English (3226) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- biosensors (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- CellDrum (3)
- Heparin (3)
- Label-free detection (3)
- additive manufacturing (3)
- capacitive field-effect sensor (3)
- hydrogen peroxide (3)
- magnetic nanoparticles (3)
- shakedown analysis (3)
- snow (3)
- tobacco mosaic virus (TMV) (3)
- Acyl-amino acids (2)
- Aeroelasticity (2)
- Aminoacylase (2)
- Bacillaceae (2)
- Bacillus atrophaeus (2)
- Biotechnological application (2)
- Brake set-up (2)
- CFD (2)
- Capacitive field-effect sensor (2)
- Chemometrics (2)
- Drinfeld modules (2)
- Einspielanalyse (2)
- Empirical process (2)
- Field-effect sensor (2)
- Freight rail (2)
- Goodness-of-fit test (2)
- Hot S-parameter (2)
- IR spectroscopy (2)
- Independence test (2)
- Light-addressable potentiometric sensor (2)
- Lipopolysaccharide (2)
- MINLP (2)
- NMR spectroscopy (2)
- Paired sample (2)
- Parametric bootstrap (2)
- Principal component analysis (2)
- Pump System (2)
- Raman spectroscopy (2)
- Shakedown analysis (2)
- Simulation (2)
- Standardization (2)
- Stiffness (2)
- Subtilases (2)
- Subtilisin (2)
- Traglastanalyse (2)
- Transcendence (2)
- UAV (2)
- bacterial cellulose (2)
- bubble column (2)
- capacitive field-effect sensors (2)
- carbonized rice husk (2)
- constructive alignment (2)
- damage (2)
- energy efficiency (2)
- examination (2)
- factory planning (2)
- fused filament fabrication (2)
- gold nanoparticles (2)
- harmonic radar (2)
- immobilization (2)
- impedance spectroscopy (2)
- light-addressable potentiometric sensor (2)
- likelihood ratio test (2)
- limit analysis (2)
- locomotion (2)
- long-term retention (2)
- manufacturing flexibility (2)
- methanation (2)
- multimodal (2)
- muscle fascicle behavior (2)
- not identically distributed (2)
- penicillinase (2)
- plug flow reactor (2)
- practical learning (2)
- prebiotic (2)
- qNMR (2)
- rapid tooling (2)
- shakedown (2)
- t-modules (2)
- ultrasound (2)
- ultrasound imaging (2)
- (Bio)degradation (1)
- (Poly)saccharides (1)
- 1P hub loads (1)
- 3-D printing (1)
- 3D nonlinear finite element model (1)
- 802.15.4 (1)
- Acceleration (1)
- Achilles tendon (1)
- Acylation (1)
- Adaptive control (1)
- Additive Manufacturing (1)
- Afterload (1)
- Ageing (1)
- Air purification (1)
- Aircraft sizing (1)
- Algal Turf Scrubber (1)
- Algal–bacterial bioflm (1)
- Alginate beads (1)
- Alkalihalobacillus okhensis (1)
- Aloe vera (1)
- AlterG (1)
- Alternating plasticity (1)
- Alzheimer's disease (1)
- Analysis (1)
- Analytischer Zulaessigkeitsnachweis (1)
- Anammox (1)
- Anastomotic leakage (1)
- Anatomy (1)
- Annulus Fibrosus (1)
- Antarctic Glaciology (1)
- Antibias (1)
- Architectural design (1)
- Architectural gear ratio (1)
- Artificial intelligence (1)
- Assembly (1)
- Assistive technology (1)
- Asymptotic efficiency (1)
- Authenticity (1)
- Autolysis (1)
- Automated driving (1)
- Automatic control (1)
- Automotive application (1)
- Automotive safety approach (1)
- Autonomy (1)
- Avalanche (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- Bacillus atrophaeus spores (1)
- Bacillus sp (1)
- Bacterial cellulose (1)
- Balance (1)
- Balanced hypergraph (1)
- Bank-issued Warrants (1)
- Basis Reduktion (1)
- Basis reduction (1)
- Bauingenieurwesen (1)
- Behaviour factor q (1)
- Benchmark (1)
- Bicharakteristikenverfahren (1)
- Bioabsorbable (1)
- Biocatalysis (1)
- Biocomposites (1)
- Biofuel (1)
- Biogas (1)
- Biomass (1)
- Biomechanical simulation (1)
- Bioreaktor (1)
- Biorefinery (1)
- Biosolubilization (1)
- Biosurfactants (1)
- Blade element method (1)
- Bloom’s Taxonomy (1)
- Bluetooth (1)
- Blutzellenlagerung (1)
- Bone quality and biomechanics (1)
- Booster Station (1)
- Booster Stations (1)
- Bootstrap (1)
- Bootstrapping (1)
- Borehole heat exchanger (1)
- Bragg peak (1)
- Brake test (1)
- Braking curves (1)
- Broad pH spectrum (1)
- Brownian Pillow (1)
- Buffering Capacity (1)
- Butanol (1)
- CAD (1)
- CAV (1)
- CNOT (1)
- CO2 emission reduction targets (1)
- CRISPR/Cas9 (1)
- Calorimetric gas sensor (1)
- Capacitive field-effect (1)
- Capacitive model (1)
- Carbon sources (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- Cardiovascular MRI (1)
- Categorial variable (1)
- Cell permeability (1)
- Cellular force (1)
- Cellulose nanostructure (1)
- Cement infiltration (1)
- Cementoblast (1)
- Censored data (1)
- Chance Constraint (1)
- Chaperone (1)
- Chaperone co-expression (1)
- Charging station (1)
- Chemical images (1)
- Chemical imaging sensor (1)
- Chemical sensor (1)
- Chondroitin sulfate (1)
- Circuit simulation (1)
- Circular Dichroism (1)
- Circular bioeconomy (1)
- Civil engineering (1)
- Clinical decision support systems (1)
- Clostridium acetobutylicum (1)
- Clusterion (1)
- Co-managed care (1)
- Collective risk model (1)
- Commercial Vehicle (1)
- Common Rail Injection System (1)
- Competence Developing Games (1)
- Competitiveness (1)
- Complex System (1)
- Complex-valued eigenvalues (1)
- Compliance (1)
- Compression (1)
- Computational biomechanics (1)
- Concomitant (1)
- Conductive Boundary Condition (1)
- Consensus (1)
- Constitutive model (1)
- Contractile tension (1)
- Contractility (1)
- Convex optimization (1)
- Cost function (1)
- Cost-effectiveness (1)
- Coverage probability (1)
- Cramér-von-Mises statistic (1)
- Cramér-von-Mises test (1)
- Crashworthiness (1)
- Cross border adjustment mechanism (1)
- Crude heparin (1)
- Crámer–von-Mises distance (1)
- Culture media (1)
- Cyclotron production (1)
- C–V method (1)
- DLR-ESTEC GOSSAMER roadmap for solar sailing (1)
- DNA biosensor (1)
- DNA hybridization (1)
- DPA (dipicolinic acid) (1)
- Damage mechanics theory (1)
- Decomposition (1)
- Decoupling (1)
- Deformation (1)
- Dehydrogenase (1)
- Design-by-analysis (1)
- Detergent protease (1)
- Deuterated solvents (1)
- Deuterium NMR (1)
- Diaphorase (1)
- Diesel Engine (1)
- Dietary supplements (1)
- Disc Degeneration (1)
- Discontinuous fractures (1)
- Discourse ethics (1)
- Discrete Optimization (1)
- Disposition Effect (1)
- Distributed Control Systems, (1)
- Diversity Management (1)
- Drag estimation (1)
- Driver assistance system (1)
- Driving cycle recognition (1)
- Druckbeanspruchung (1)
- Druckbehälter (1)
- Druckbelastung (1)
- Druckgeräte (1)
- Drug simulation (1)
- Dry-low-NOx (DLN) combustion (1)
- Duality (1)
- Dynamic simulation (1)
- E-Mobility (1)
- ECMS (1)
- EIS capacitive sensor (1)
- ELISA (1)
- ES-FEM (1)
- Effective modal mass (1)
- Eigenvalue trajectories (1)
- Einspiel-Analyse (1)
- Einspiel-Kriterium (1)
- Einspielen (1)
- Elastizität (1)
- Elderly (1)
- Electrolyte–insulator–semiconductor (1)
- Electromagnetism (1)
- Electromechanical modeling (1)
- Electronic vehicle (1)
- Elemental (1)
- Emilia-Romagna earthquake (1)
- Empirical consequence curves (1)
- Empirical fragility functions (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Endothelial dysfunction (1)
- Energy management strategies (1)
- Energy-intensive industry (1)
- Engineering Application (1)
- Engineering Habitus (1)
- Enterprise information systems (1)
- Environmental impact (1)
- Enzymatic biosensor (1)
- Enzyme coverage (1)
- Enzyme logic gate (1)
- Enzyme-linked immunosorbent assay (1)
- Epithel (1)
- Equivalence test (1)
- Esophageal Doppler monitor (1)
- European Transient Cycle (1)
- Eutectic Silver Copper alloy (1)
- Experiment (1)
- Experimental validation (1)
- Explainability (1)
- External knee adduction moments (1)
- Extracellular enzymes (1)
- Extraterrestrial Glaciology (1)
- FS-FEM (1)
- Fall prevention (1)
- Fault approximation (1)
- Fault detection (1)
- Feature selection (1)
- Fehlerstellen (1)
- Fibroblast (1)
- Field effect (1)
- Field-effect biosensor (1)
- Finite differences (1)
- Finite element analysis (1)
- Finite element method (1)
- Finite element modelling (1)
- Finland (1)
- Fließgrenze (1)
- Floor prices (1)
- Flutter (1)
- Force (1)
- Forces (1)
- Fracture classification (1)
- Fracture configuration (1)
- Fracture simulation (1)
- Frame structure (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Frequency mixing magnetic detection (1)
- Full-vehicle crash test (1)
- Functional Delta Method (1)
- Furnace (1)
- Fusion (1)
- GOSSAMER-1 (1)
- Ga-68 (1)
- Game-based learning (1)
- Gamification (1)
- Gamma distribution (1)
- Genetic algorithm (1)
- Geriatric (1)
- German (1)
- Germany (1)
- Glaciological instruments and methods (1)
- Glaucoma (1)
- Global and local collapse (1)
- Glucosamine (1)
- Gold nanoparticles (1)
- Goodness-of-fit tests for uniformity (1)
- Grenzwertberechnung (1)
- Ground-level falls (1)
- Hadamard differentiability (1)
- Haemodialysis (1)
- Hall’s Theorem (1)
- Halotolerant protease (1)
- Handbike (1)
- Harnleiter (1)
- Hazard assessment (1)
- Heart tissue culture (1)
- Heat transport (1)
- Hemoglobin structure (1)
- Heterostructure (1)
- High hydrogen combustion (1)
- High-field NMR (1)
- Higher derivations (1)
- Hip fractures (1)
- Hodgkin–Huxley models (1)
- Hoeffding-Blum-Kiefer-Rosenblatt independence test (1)
- Homogenization (1)
- Hotelling’s T² test (1)
- Human factors (1)
- Human-Computer interaction (1)
- Hydrogen combustion (1)
- Hydrogen gas turbine (1)
- Hydrogen peroxide (1)
- Hyperdifferentials (1)
- Hypergraph (1)
- Hypersecretion (1)
- Hämoglobin (1)
- Hämoglobinstruktur (1)
- INSYSME (1)
- IP-based networks (1)
- IR (1)
- IT security education (1)
- Illustration (1)
- Image Reconstruction (1)
- Imaging (1)
- Impedance spectroscopy (1)
- In-plane performance, isolation (1)
- Incident analysis (1)
- Inclusion bodies (1)
- Incomplete data (1)
- Individual Investors (1)
- Induced pluripotent stem cells (1)
- Industrial Automation Technology, (1)
- Infill wall design (1)
- Information extraction (1)
- Inorganic ions (1)
- Inotropic compounds (1)
- Instructional design (1)
- Integrated empirical distribution (survival) function (1)
- Interior transmission problem (1)
- Interstellar objects (1)
- Intervertebral Disc (1)
- Intradiscal Pressure (1)
- Inverse Scattering (1)
- Inverse dynamic problem (1)
- Inverse kinematic problem (1)
- Inverse scattering problem (1)
- Ion channels (1)
- Ions (1)
- Iterative learning control (1)
- Justice (1)
- Keyword analysis (1)
- Kinetic energy (1)
- Knochen (1)
- Knochenbildung (1)
- Knochenchirugie (1)
- Knochendichte (1)
- Koenig’s Theorem (1)
- Kohlenstofffaser (1)
- LPS (1)
- Lab-on-Chip (1)
- Lactobacillus rhamnosus GG (1)
- Landslide tsunamis (1)
- Langevin theory (1)
- Large scale tests (1)
- Latvia (1)
- Layer-by-layer adsorption (1)
- LbL films (1)
- Left ventriular function (1)
- Level system (1)
- Lidar (1)
- Light-addressable Potentiometric Sensor (1)
- Lignocellulose (1)
- Limit analysis (1)
- Linear discriminant analysis (1)
- Linear elastic analysis (1)
- Liver (1)
- Local path planning (1)
- Long COVID (1)
- Low-field NMR (1)
- Luftreiniger (1)
- MCDA (1)
- MILP (1)
- MOS (1)
- MR-stethoscope (1)
- MST (1)
- MUT measurement; scanner (1)
- Machine learning (1)
- Magnetic field strength (1)
- Magnetic nanoparticles (1)
- Magnetic resonance imaging (MRI) (1)
- Mainstream (1)
- Manipulated variables (1)
- Manufacturer (1)
- Marginal homogeneity test (1)
- Marker-free mutagenesis (1)
- Masonry infill (1)
- Masonry partition walls (1)
- Matching (1)
- Materialermüdung (1)
- Measurement models (1)
- Measurement uncertainty (1)
- Mechanotransduction (1)
- Medical AI (1)
- Medical radionuclide production (1)
- Medusomyces gisevi (1)
- Metal contaminants (1)
- Metascintillator (1)
- Methane (1)
- Microcirculation (1)
- Microfluidic solvent extraction (1)
- Micromagnetic simulation (1)
- Micromix combustion (1)
- Mikrosystemtechnik (1)
- Mild cognitive impairment (1)
- Missions (1)
- Mobility (1)
- Mobility tests (1)
- Mobility transition (1)
- Mode converter (1)
- Model-driven software engineering (1)
- Modelica (1)
- Modeling (1)
- Modelling (1)
- Modern constructions (1)
- Molecular modelling (1)
- Molecular weight determination (1)
- Molten salt receiver system (1)
- Molten salt solar tower (1)
- Monte Carlo Tree Search (1)
- Morphing (1)
- Multi-criteria decision analysis (1)
- Multi-objective optimization (1)
- Multi-sample problem (1)
- Multi-storey (1)
- Multianalyte detection (1)
- Multicell (1)
- Multiple TOF kernels (1)
- Multiplexing (1)
- Multirotor UAS (1)
- Muscle (1)
- Muscle Fascicle (1)
- Muscle Force (1)
- Musculoskeletal model (1)
- Musculoskeletal system (1)
- Myocardial infarction and cardiac death (1)
- NGN (1)
- NMR (1)
- NMR exchange relaxometry (1)
- NONOate (1)
- Natural fibres (1)
- Natural frequency (1)
- Negative Feedback Trading (1)
- Negative impedance convertor (1)
- Neural Network (1)
- Nitric Oxide (1)
- Nitric Oxide Donor (1)
- Nitrogen removal (1)
- Non-parallel fissures (1)
- Nonequilibrium dynamics (1)
- Nonlinear Dynamics (1)
- Normative standards (1)
- Nucleus Pulposus (1)
- Numerical inversion of Laplace transforms (1)
- Numerical linear algebra (1)
- Numerical modelling (1)
- O2 plasma (1)
- Obstacle avoidance (1)
- Ocular blood flow (1)
- Organic acids (1)
- Organic light-emitting diode display (1)
- Organizational Culture (1)
- Organkultur (1)
- Osteoporose (1)
- Osteoporosis (1)
- Out-of-plane capacity (1)
- Overland flow (1)
- P2G (1)
- PBEE (1)
- PIV (1)
- PLS-regression (1)
- PROFINET (1)
- Paralympic sport (1)
- Parasitic drag (1)
- Parking (1)
- Partial nitritation (1)
- Path planning (1)
- Penicillin (1)
- Periods (1)
- Permeability (1)
- Permeabilität (1)
- Peroxidase (1)
- Pflanzenphysiologie (1)
- Pflanzenscanner (1)
- Pflanzenstress (1)
- Pharmacology (1)
- Physiology (1)
- Piping (1)
- Plant virus (1)
- Plasma (1)
- Plasma diagnostics (1)
- Plasmacluster ion technology (1)
- Plastizität (1)
- Poly(allylamine hydrochloride) (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Polylactide acid (1)
- Polymer-matrix composites (1)
- Polysaccharides (1)
- Porositat (1)
- Post-COVID-19 syndrome (1)
- Powertrain (1)
- Precast buildings (1)
- Predictive battery discharge (1)
- Preference assessment (1)
- Pressure loaded crack-face (1)
- Prevention (1)
- Probability distribution mapping (1)
- Process virtualization (1)
- Product bundling (1)
- Product-integration (1)
- Progressive plastic deformation (1)
- Propeller (1)
- Propeller elasticity (1)
- Propeller whirl flutter (1)
- Proper Orthogonal Decomposition (1)
- Prophylaxis (1)
- Proximal humerus fracture (1)
- Pulsations (1)
- Pumping systems (1)
- Q-criterion (1)
- Quality control (1)
- Quantum chemistry (1)
- RAMMS (1)
- RVA (1)
- Radar (1)
- Rapid Prototyping (1)
- Rapid Technologie (1)
- Rapid prototyping (1)
- Ratchetting (1)
- Raumluft (1)
- Real-time monitoring (1)
- Recombinant activated protein C (1)
- Red blood cell storage (1)
- Regionalization (1)
- Rehabilitation Technology and Prosthetics (1)
- Rehabilitation engineering (1)
- Reinforced concrete frame (1)
- Requirements prioritization (1)
- Requirements relations (1)
- Resampling test (1)
- Reservation system (1)
- Resistive temperature detector (1)
- Resolvent Operator (1)
- Resonance-mode measurement (1)
- Response Surface Method (1)
- Retinal vessel analysis (1)
- Retinal vessels (1)
- Robotic rehabilitation (1)
- Rohr (1)
- Rohrbruch (1)
- Rotary encoder (1)
- Rotator cuff (1)
- Running (1)
- S-FEM (1)
- SFCW (1)
- SLM (1)
- SOA (1)
- ScaLAPACK (1)
- Schwammknochen (1)
- Seismic design (1)
- Seismic loading (1)
- Selective Catalytic Reduction (1)
- Self-driving (1)
- Semi-parametric random censorship model (1)
- Septic cardiomyopathy (1)
- Services (1)
- Shakedown (1)
- Shakedown criterion (1)
- Shoulder (1)
- Shunting (1)
- Silk fibroin (1)
- Simultaneous determination (1)
- Skeletal muscle (1)
- Slab deflection (1)
- Small Aral Sea (1)
- Small spacecraft (1)
- Snow (1)
- Sn₃O₄ (1)
- Soft independent modeling of class analogy (1)
- Software and systems modeling (1)
- Solar sail (1)
- Solitary waves (1)
- Spectroscopy (1)
- Spleen (1)
- Stahl (1)
- Steel industry (1)
- Stenotrophomonas maltophilia (1)
- Sterilisation process (1)
- Stochastic Programming (1)
- Streptomyces griseus (1)
- Streptomyces lividans (1)
- Stress concentrations (1)
- Structural design (1)
- Strukturanalyse (1)
- Subclacial exploration (1)
- Subglacial lakes (1)
- Surgical Navigation and Robotics (1)
- Surgical staplers (1)
- Survival analysis (1)
- Suspension bridge (1)
- TMV adsorption (1)
- TOF PET (1)
- Tank (1)
- Ta₂O₅ gate (1)
- Technical Operations Research (1)
- Technical Operations Research (TOR) (1)
- Telecommunication (1)
- Temperaturabhängigkeit (1)
- Tendon Rupture (1)
- Tendon properties (1)
- Tendons (1)
- Tension (1)
- Thin shell finite elements (1)
- Tinetti test (1)
- Tissue Engineering (1)
- Tobacco mosaic virus (TMV) (1)
- Tool support (1)
- Trading Behavior (1)
- Traglast (1)
- Train composition (1)
- Trajectories (1)
- Transformation (1)
- Transient flux distribution (1)
- Transmission Eigenvalues (1)
- Two-phase modelling (1)
- Typographie (1)
- USP (1)
- Ultrasound (1)
- Uncertainty (1)
- Uniaxial compression test (1)
- Unreinforced masonry buildings (1)
- Unsteady aerodynamics (1)
- Uracil-phosphoribosyltransferase (1)
- User study (1)
- Utilization improvement (1)
- VM (1)
- VOF (1)
- Vapnik–Čhervonenkis class (1)
- Variable height stapler design (1)
- Vascular response (1)
- Vasomotions (1)
- Velocity (1)
- Vertebroplastie (1)
- Vertebroplasty (1)
- Vertex cover (1)
- Vibrio natriegens (1)
- Virtual reality (1)
- Virtuelle Maschine (1)
- Viscous flow (1)
- Viskose Strömung (1)
- Viskosität (1)
- Visual field asymmetry (1)
- Volterra integral equation (1)
- Volume of confidence regions (1)
- Volume status (1)
- Wastewater (1)
- Water Distribution (1)
- Water Supply Networks (1)
- Wiegand sensor (1)
- Wind milling (1)
- Wind tunnel experiments (1)
- Wireless Networks (1)
- Wolff's Law (1)
- Wolffsches Gesetz (1)
- Wundheilung (1)
- XOR (1)
- Zeta potential (1)
- Zug-Druck Belastung (1)
- acetoin (1)
- acetoin reductase (1)
- achilles tendon (1)
- actin cytoskeleton (1)
- actuator-sensor system (1)
- adaptive systems (1)
- adipose-derived stromal cells (ASCs) (1)
- adsorption (1)
- agility (1)
- alcoholic beverages (1)
- allocation (1)
- alternierend Verformbarkeit (1)
- aminooctanethiol (1)
- amperometric biosensors (1)
- anaesthetic complications (1)
- anammox (1)
- anisotropy (1)
- annealing (1)
- aortic perfusion (1)
- aromatic amines (1)
- artificial intelligence (1)
- artificial olfactory image (1)
- aseptic parameters (1)
- aspergillus (1)
- assistance system (1)
- asymptotic relative efficiency (1)
- atomic layer deposition (1)
- automated vehicles (1)
- autonomous navigation (1)
- availability (1)
- barium strontium titanate (1)
- batteries and fuel cells (1)
- bi-enzyme biosensor (1)
- biaxial tensile experiment (1)
- bicharacteristics (1)
- bio-methane (1)
- bioavailability (1)
- bioburdens (1)
- biocompatible (1)
- biocompatible materials (1)
- biodegradabl (1)
- biodegradable electronic devices (1)
- biodegradable polymers (1)
- biofilms (1)
- biological dosimeter (1)
- biomechanics (1)
- biomethane (1)
- biopotential electrodes (1)
- biosensor (1)
- body imaging at 7 T MRI (1)
- body limbs (1)
- bone density (1)
- bone structure (1)
- bootstrap (1)
- borefields (1)
- borehole disposal (1)
- brachytherapy (1)
- building energy modelling (1)
- building energy simulation (1)
- burst pressure (1)
- burst tests (1)
- calorimetric gas sensor (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- cancellous bone (1)
- capacitive EIS sensor (1)
- capacitive electrolyte–insulator–semiconductor sensors (1)
- capacitive model (1)
- carbon electrodes (1)
- cardiac gating (1)
- cardiomyocyte biomechanics (1)
- cardiovascular MR imaging (1)
- catalytic metal (1)
- cell aerosolization (1)
- cell atomization (1)
- central symmetry test (1)
- cerebral small vessel disease (1)
- chance constrained programming (1)
- change management (1)
- chemical sensor (1)
- churches (1)
- civil engineering (1)
- climate change (1)
- coculture (1)
- cognitive impairment (1)
- coherent structures (1)
- colorization (1)
- community dwelling (1)
- complete block symmetry (1)
- compression behavior (1)
- computational fluid dynamics analysis (1)
- concentrating collector (1)
- conditional excess distribution (1)
- conditional expectation principle (1)
- confidence interval (1)
- connected automated vehicles (1)
- connective tissue (1)
- constitutive modeling (1)
- contactless conductivity sensor (1)
- control gate (1)
- correlation (1)
- coupled Néel–Brownian relaxation dynamics (1)
- covariance principle (1)
- crop yield (1)
- crystallization (1)
- cyber-physical production systems (1)
- dam-break (1)
- debris flow (1)
- deficit irrigation (1)
- dental trauma (1)
- deserts (1)
- design of technical systems (1)
- detection of charged macromolecules (1)
- detergent protease (1)
- dialysis (1)
- difficult airway (1)
- digital factory (1)
- direct method (1)
- disposal facility (1)
- distorted element (1)
- distribution grid simulation (1)
- diversity management (1)
- double-lumen tube intubation (1)
- drag force (1)
- drop jump (1)
- drug metabolising enzymes (1)
- drug–drug interactions (1)
- e-mobility (1)
- eVTOL development (1)
- eVTOL safety (1)
- earthquake engineering (1)
- ecological structure (1)
- eigensolvers (1)
- elastic solids (1)
- elastomers (1)
- electrocardiogram (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- electrolyte-insulator-semiconductor capacitors (1)
- electromyography (1)
- electronic nose (1)
- electrospinning (1)
- encapsulation materials (1)
- endoluminal (1)
- endospores (1)
- energy (1)
- energy absorption (1)
- energy dissipation (1)
- energy transfer (1)
- engineering (1)
- entrepreneurship education (1)
- enzymatic (bio)degradation (1)
- enzymatic biosensor (1)
- enzyme cascade (1)
- enzyme kinetics (1)
- enzyme-logic gate (1)
- epithelization (1)
- equivalent circuit (1)
- equivalent stiffness (1)
- event-based simulation (1)
- exchangeability test (1)
- exopolysaccharides (1)
- experimental evaluation (1)
- extracorporeal membrane oxygenation (1)
- eye movement modelling examples (1)
- fatigue analyses (1)
- fibers (1)
- fibroin (1)
- field-effect structure (1)
- filamentous fungi (1)
- flaw (1)
- force generation (1)
- forecast (1)
- forehead EEG (1)
- fortschreitende plastische Deformation (1)
- frequency mixing (1)
- fuel cell vehicle (1)
- functional data (1)
- gait (1)
- gamification (1)
- gas sensor (1)
- gaseous hydrogen peroxide (1)
- genetic algorithm (1)
- genome engineering (1)
- geological disposal (1)
- geothermal (1)
- global optimization (1)
- glucose (1)
- glucose oxidase (GOx) (1)
- glycine (1)
- goodness-of-fit test (1)
- granular silo (1)
- graphene oxide (1)
- halotolerant protease (1)
- harmonic radar tags (1)
- healthy aging (1)
- heat demand (1)
- heat transfer coefficient (1)
- heating system (1)
- heavy metals (1)
- hiPS cardiomyocytes (1)
- high field MR imaging (1)
- high-alkaline subtilisin (1)
- high-intensity exercise (1)
- high-k material (1)
- horseradish peroxidase (HRP) (1)
- huge dimensional data (1)
- human dermal fibroblasts (1)
- human metabolites (1)
- humic acid (1)
- hydraulic modelling (1)
- hydrogel (1)
- hydrogels (1)
- hydroxylation (1)
- hyper-gravity (1)
- hyperelastic (1)
- hypo-gravity (1)
- hypoplasticity (1)
- ignition (1)
- impulsive effects (1)
- in-ear EEG (1)
- in-situ monitoring (1)
- incontinence (1)
- independence test (1)
- industrial agents (1)
- infill strategy (1)
- innovation management (1)
- intelligent control (1)
- intelligent energy management (1)
- intraclass correlation coefficient (1)
- irradiation (1)
- key performance indicators (1)
- konvexe Optimierung (1)
- lable-free detection (1)
- large language models (1)
- large-scale inspection (1)
- layer-by-layer technique (1)
- legal obligations (1)
- light-addressable electrode (1)
- light-addressing technologies (1)
- lignite (1)
- limit load (1)
- lipopolysaccharide (1)
- lipopolysaccharides (1)
- liquid-storage tank (1)
- liquid-structure interaction (1)
- lizards (1)
- load limit (1)
- low-rank coal (1)
- machine learning (1)
- macro-element (1)
- magnetic actuation (1)
- magnetic beads (1)
- magnetic biosensing (1)
- magnetic relaxation (1)
- magnetic resonance imaging (1)
- magnetic sandwich immunoassay (1)
- magnetic sensing (1)
- magnetic sensors (1)
- magnetic separation (1)
- magnetic tweezers (1)
- magnetophoretic velocity (1)
- mainstream deammonification (1)
- manufacturing (1)
- manufacturing data model (1)
- mathematical optimization (1)
- mechanical buffer (1)
- mechanical properties (1)
- metagenomics (1)
- metal-oxide-semiconductor structure (1)
- microbial diversity (1)
- microfluidics (1)
- micromagnetic simulation (1)
- micronutrients (1)
- microplasma (1)
- microwave (MW) plasma (1)
- microwave measurements (1)
- mix flexibility (1)
- mixed-integer linear programming (1)
- mobile manipulation (1)
- model performance (1)
- multi-agent systems (1)
- multi-functional material (1)
- multi-sensing platform (1)
- multianalyte detection (1)
- multinomial distribution (1)
- multiparametric immunoassays (1)
- multiplex detection (1)
- multivariate normal distribution (1)
- muscle mechanics (1)
- nanobelts (1)
- nanomaterials (1)
- nanoparticle coverage (1)
- nanostructured carbonized plant parts (1)
- nanostrukturierte carbonisierte Pflanzenteile (1)
- naphtols (1)
- neutrons (1)
- next generation network (1)
- nitrogen elimination (1)
- non-simplex S-FEM elements (1)
- nonlinear VNA measurements (1)
- nonlinear radar (1)
- nonlinear transient analyses (1)
- novel photoexcitation method (1)
- nuclear waste (1)
- numerical model (1)
- on-chip integrated addressable EISCAP sensors (1)
- onion (1)
- optical fibers (1)
- optical sensor setup (1)
- optical spore trapping (1)
- optical trapping (1)
- optimization (1)
- optimization system (1)
- organosilanes (1)
- overload (1)
- oxidative stable protease (1)
- pH sensors (1)
- parabolic flight (1)
- penicillin (1)
- performance analysis (1)
- performance testing (1)
- phenols (1)
- phonocardiogram (1)
- photoelectrochemistry (1)
- physical model (1)
- physiology (1)
- pipes (1)
- plant scanner (1)
- plant stress (1)
- plant virus detection (1)
- plasma jet (1)
- plug-based microfluidic device (1)
- point-focussing system (1)
- poly(d, l-lactic acid) (1)
- polyaniline (1)
- polyaspartic acid (1)
- polyetheretherketone (1)
- polyetheretherketone (PEEK) (1)
- polystyrene sulfonate (1)
- porous materials (1)
- portfolio risk (1)
- power-to-gas (1)
- prevention (1)
- product bundling (1)
- product liability (1)
- production planning and control (1)
- programming (1)
- prostate cancer (1)
- prostatectomy (1)
- proton therapy (1)
- protons (1)
- psychosocial (1)
- pullulan (1)
- quality of life (1)
- random effects (1)
- random effects meta-regression model (1)
- ratchetting (1)
- raytracing (1)
- recombinant expression (1)
- rehabilitation (1)
- relative dosimetry (1)
- reliability analysis (1)
- reliability of structures (1)
- remote sensing (1)
- research association (1)
- resilience (1)
- retention time (1)
- retinal microvasculature (1)
- retinal vessels (1)
- rubber (1)
- running (1)
- sEMG (1)
- sarcomere operating length (1)
- scanned light pulse technique (1)
- seismic response (1)
- semantic role labeling (1)
- separable Hilbert space (1)
- series elastic element behavior (1)
- service-oriented architectures (1)
- shakedown analyses (1)
- shotgun sequencing (1)
- shoulder (1)
- silanization (1)
- simulation (1)
- sizing (1)
- slum classification (1)
- smart-charging (1)
- smooth muscle contraction (1)
- soil amendment (1)
- soil health (1)
- soil remediation (1)
- solar process heat (1)
- spatial resolution (1)
- speaker attribution (1)
- spore kill rate (1)
- sprint start (1)
- standard error of measurement (1)
- sterilisation (1)
- sterility (1)
- sterility tests (1)
- sterilization (1)
- sterilization conditions (1)
- sterilization efficacy (1)
- sterilization methods (1)
- stiffness (1)
- stochastic optimization (1)
- stochastic programming (1)
- strain energy function (1)
- stretch reflex (1)
- stretch-shortening cycle (1)
- structure-soil-structure interaction (1)
- superabsorbent polymers (1)
- superparamagnetic bead (1)
- superparamagnetic nanoparticles (1)
- supramolecular structures (1)
- surface functionalization (1)
- surface modification (1)
- surface-orthogonal path planning (1)
- survival (1)
- sustainability (1)
- swelling properties (1)
- swimming (1)
- system optimization (1)
- system synthesis (1)
- technical operations research (1)
- technology planning (1)
- telecommunication (1)
- temperature (1)
- tendon rupture (1)
- tension–torsion loading (1)
- test-retest reliability (1)
- theory and modeling (1)
- thermal dose (1)
- thermal ratcheting (1)
- tilted constant illumination (1)
- tissue temperature (1)
- titanium dioxide photoanode (1)
- transmit antenna arrays (1)
- transponder (1)
- transporters (1)
- tri-lineage differentiation (1)
- truss (1)
- turnip vein clearing virus (TVCV) (1)
- twin-fluid atomizer (1)
- ultrasonography (1)
- ultrathin gate insulators (1)
- uniformly most powerful invariant test (1)
- unloading (1)
- urease (1)
- validation methods (1)
- vault (1)
- vessels (1)
- video learning (1)
- videolaryngoscopy (1)
- virgin passive (1)
- virtual clean room (1)
- viscoelasticity (1)
- visualization (1)
- volume flexibility (1)
- walking (1)
- walking gait (1)
- wastewater (1)
- water economy (1)
- water supply design (1)
- wind turbine production (1)
- wound healing (1)
- yield (1)
- yield stress (1)
- α-aminoacylase (1)
- ε-lysine acylase (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (1343)
- INB - Institut für Nano- und Biotechnologien (501)
- Fachbereich Chemie und Biotechnologie (466)
- IfB - Institut für Bioengineering (408)
- Fachbereich Elektrotechnik und Informationstechnik (401)
- Fachbereich Energietechnik (360)
- Fachbereich Luft- und Raumfahrttechnik (247)
- Fachbereich Maschinenbau und Mechatronik (147)
- Fachbereich Wirtschaftswissenschaften (106)
- Fachbereich Bauingenieurwesen (68)
- Solar-Institut Jülich (43)
- ECSM European Center for Sustainable Mobility (27)
- Sonstiges (21)
- Institut fuer Angewandte Polymerchemie (20)
- Freshman Institute (17)
- Nowum-Energy (16)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (15)
- Fachbereich Gestaltung (12)
- Fachbereich Architektur (9)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (5)
Photoelectrochemical (PEC) biosensors are a rather novel type of biosensors thatutilizelighttoprovideinformationaboutthecompositionofananalyte,enablinglight-controlled multi-analyte measurements. For enzymatic PEC biosensors,amperometric detection principles are already known in the literature. In con-trast, there is only a little information on H+-ion sensitive PEC biosensors. Inthis work, we demonstrate the detection of H+ions emerged by H+-generatingenzymes, exemplarily demonstrated with penicillinase as a model enzyme on atitanium dioxide photoanode. First, we describe the pH sensitivity of the sensorand study possible photoelectrocatalytic reactions with penicillin. Second, weshow the enzymatic PEC detection of penicillin.
Plant viruses are major contributors to crop losses and induce high economic costs worldwide. For reliable, on-site and early detection of plant viral diseases, portable biosensors are of great interest. In this study, a field-effect SiO2-gate electrolyte-insulator-semiconductor (EIS) sensor was utilized for the label-free electrostatic detection of tobacco mosaic virus (TMV) particles as a model plant pathogen. The capacitive EIS sensor has been characterized regarding its TMV sensitivity by means of constant-capacitance method. The EIS sensor was able to detect biotinylated TMV particles from a solution with a TMV concentration as low as 0.025 nM. A good correlation between the registered EIS sensor signal and the density of adsorbed TMV particles assessed from scanning electron microscopy images of the SiO2-gate chip surface was observed. Additionally, the isoelectric point of the biotinylated TMV particles was determined via zeta potential measurements and the influence of ionic strength of the measurement solution on the TMV-modified EIS sensor signal has been studied.
Contractile behavior of the gastrocnemius medialis muscle during running in simulated hypogravity
(2021)
Vigorous exercise countermeasures in microgravity can largely attenuate muscular degeneration, albeit the extent of applied loading is key for the extent of muscle wasting. Running on the International Space Station is usually performed with maximum loads of 70% body weight (0.7 g). However, it has not been investigated how the reduced musculoskeletal loading affects muscle and series elastic element dynamics, and thereby force and power generation. Therefore, this study examined the effects of running on the vertical treadmill facility, a ground-based analog, at simulated 0.7 g on gastrocnemius medialis contractile behavior. The results reveal that fascicle−series elastic element behavior differs between simulated hypogravity and 1 g running. Whilst shorter peak series elastic element lengths at simulated 0.7 g appear to be the result of lower muscular and gravitational forces acting on it, increased fascicle lengths and decreased velocities could not be anticipated, but may inform the development of optimized running training in hypogravity. However, whether the alterations in contractile behavior precipitate musculoskeletal degeneration warrants further study.
The coupling of ligand-stabilized gold nanoparticles with field-effect devices offers new possibilities for label-free biosensing. In this work, we study the immobilization of aminooctanethiol-stabilized gold nanoparticles (AuAOTs) on the silicon dioxide surface of a capacitive field-effect sensor. The terminal amino group of the AuAOT is well suited for the functionalization with biomolecules. The attachment of the positively-charged AuAOTs on a capacitive field-effect sensor was detected by direct electrical readout using capacitance-voltage and constant capacitance measurements. With a higher particle density on the sensor surface, the measured signal change was correspondingly more pronounced. The results demonstrate the ability of capacitive field-effect sensors for the non-destructive quantitative validation of nanoparticle immobilization. In addition, the electrostatic binding of the polyanion polystyrene sulfonate to the AuAOT-modified sensor surface was studied as a model system for the label-free detection of charged macromolecules. Most likely, this approach can be transferred to the label-free detection of other charged molecules such as enzymes or antibodies.
This paper presents a new SIMO radar system based on a harmonic radar (HR) stepped frequency continuous wave (SFCW) architecture. Simple tags that can be electronically individually activated and deactivated via a DC control voltage were developed and combined to form an MO array field. This HR operates in the entire 2.45 GHz ISM band for transmitting the illumination signal and receives at twice the stimulus frequency and bandwidth centered around 4.9 GHz. This paper presents the development, the basic theory of a HR system for the characterization of objects placed into the propagation path in-between the radar and the reflectors (similar to a free-space measurement with a network analyzer) as well as first measurements performed by the system. Further detailed measurement series will be made available later on to other researchers to develop AI and machine learning based signal processing routines or synthetic aperture radar algorithms for imaging, object recognition, and feature extraction. For this purpose, the necessary information is published in this paper. It is explained in detail why this SIMO-HR can be an attractive solution augmenting or replacing existing systems for radar measurements in production technology for material under test measurements and as a simplified MIMO system. The novel HR transfer function, which is a basis for researchers and developers for material characterization or imaging algorithms, is introduced and metrologically verified in a well traceable coaxial setup.
Humic substances (HS), as important environmental components, are essential to soil health and agricultural sustainability. The usage of low-rank coal (LRC) for energy generation has declined considerably due to the growing popularity of renewable energy sources and gas. However, their potential as soil amendment aimed to maintain soil quality and productivity deserves more recognition. LRC, a highly heterogeneous material in nature, contains large quantities of HS and may effectively help to restore the physicochemical, biological, and ecological functionality of soil. Multiple emerging studies support the view that LRC and its derivatives can positively impact the soil microclimate, nutrient status, and organic matter turnover. Moreover, the phytotoxic effects of some pollutants can be reduced by subsequent LRC application. Broad geographical availability, relatively low cost, and good technical applicability of LRC offer the advantage of easy fulfilling soil amendment and conditioner requirements worldwide. This review analyzes and emphasizes the potential of LRC and its numerous forms/combinations for soil amelioration and crop production. A great benefit would be a systematic investment strategy implicating safe utilization and long-term application of LRC for sustainable agricultural production.
Past earthquakes demonstrated the high vulnerability of industrial facilities equipped with complex process technologies leading to serious damage of process equipment and multiple and simultaneous release of hazardous substances. Nonetheless, current standards for seismic design of industrial facilities are considered inadequate to guarantee proper safety conditions against exceptional events entailing loss of containment and related consequences. On these premises, the SPIF project -Seismic Performance of Multi-Component Systems in Special Risk Industrial Facilities- was proposed within the framework of the European H2020 SERA funding scheme. In detail, the objective of the SPIF project is the investigation of the seismic behaviour of a representative industrial multi-storey frame structure equipped with complex process components by means of shaking table tests. Along this main vein and in a performance-based design perspective, the issues investigated in depth are the interaction between a primary moment resisting frame (MRF) steel structure and secondary process components that influence the performance of the whole system; and a proper check of floor spectra predictions. The evaluation of experimental data clearly shows a favourable performance of the MRF structure, some weaknesses of local details due to the interaction between floor crossbeams and process components and, finally, the overconservatism of current design standards w.r.t. floor spectra predictions.
The on-chip integration of multiple biochemical sensors based on field-effect electrolyte-insulator-semiconductor capacitors (EISCAP) is challenging due to technological difficulties in realization of electrically isolated EISCAPs on the same Si chip. In this work, we present a new simple design for an array of on-chip integrated, individually electrically addressable EISCAPs with an additional control gate (CG-EISCAP). The existence of the CG enables an addressable activation or deactivation of on-chip integrated individual CG-EISCAPs by simple electrical switching the CG of each sensor in various setups, and makes the new design capable for multianalyte detection without cross-talk effects between the sensors in the array. The new designed CG-EISCAP chip was modelled in so-called floating/short-circuited and floating/capacitively-coupled setups, and the corresponding electrical equivalent circuits were developed. In addition, the capacitance-voltage curves of the CG-EISCAP chip in different setups were simulated and compared with that of a single EISCAP sensor. Moreover, the sensitivity of the CG-EISCAP chip to surface potential changes induced by biochemical reactions was simulated and an impact of different parameters, such as gate voltage, insulator thickness and doping concentration in Si, on the sensitivity has been discussed.
Magnetic immunoassays employing Frequency Mixing Magnetic Detection (FMMD) have recently become increasingly popular for quantitative detection of various analytes. Simultaneous analysis of a sample for two or more targets is desirable in order to reduce the sample amount, save consumables, and save time. We show that different types of magnetic beads can be distinguished according to their frequency mixing response to a two-frequency magnetic excitation at different static magnetic offset fields. We recorded the offset field dependent FMMD response of two different particle types at frequencies ƒ₁ + n⋅ƒ₂, n = 1, 2, 3, 4 with ƒ₁ = 30.8 kHz and ƒ₂ = 63 Hz. Their signals were clearly distinguishable by the locations of the extremes and zeros of their responses. Binary mixtures of the two particle types were prepared with different mixing ratios. The mixture samples were analyzed by determining the best linear combination of the two pure constituents that best resembled the measured signals of the mixtures. Using a quadratic programming algorithm, the mixing ratios could be determined with an accuracy of greater than 14%. If each particle type is functionalized with a different antibody, multiplex detection of two different analytes becomes feasible.
An approach to automatically generate a dynamic energy simulation model in Modelica for a single existing building is presented. It aims at collecting data about the status quo in the preparation of energy retrofits with low effort and costs. The proposed method starts from a polygon model of the outer building envelope obtained from photogrammetrically generated point clouds. The open-source tools TEASER and AixLib are used for data enrichment and model generation. A case study was conducted on a single-family house. The resulting model can accurately reproduce the internal air temperatures during synthetical heating up and cooling down. Modelled and measured whole building heat transfer coefficients (HTC) agree within a 12% range. A sensitivity analysis emphasises the importance of accurate window characterisations and justifies the use of a very simplified interior geometry. Uncertainties arising from the use of archetype U-values are estimated by comparing different typologies, with best- and worst-case estimates showing differences in pre-retrofit heat demand of about ±20% to the average; however, as the assumptions made are permitted by some national standards, the method is already close to practical applicability and opens up a path to quickly estimate possible financial and energy savings after refurbishment.
In the context of the Solvency II directive, the operation of an internal risk model is a possible way for risk assessment and for the determination of the solvency capital requirement of an insurance company in the European Union. A Monte Carlo procedure is customary to generate a model output. To be compliant with the directive, validation of the internal risk model is conducted on the basis of the model output. For this purpose, we suggest a new test for checking whether there is a significant change in the modeled solvency capital requirement. Asymptotic properties of the test statistic are investigated and a bootstrap approximation is justified. A simulation study investigates the performance of the test in the finite sample case and confirms the theoretical results. The internal risk model and the application of the test is illustrated in a simplified example. The method has more general usage for inference of a broad class of law-invariant and coherent risk measures on the basis of a paired sample.
Rehabilitative body weight supported gait training aims at restoring walking function as a key element in activities of daily living. Studies demonstrated reductions in muscle and joint forces, while kinematic gait patterns appear to be preserved with up to 30% weight support. However, the influence of body weight support on muscle architecture, with respect to fascicle and series elastic element behavior is unknown, despite this having potential clinical implications for gait retraining. Eight males (31.9 ± 4.7 years) walked at 75% of the speed at which they typically transition to running, with 0% and 30% body weight support on a lower-body positive pressure treadmill. Gastrocnemius medialis fascicle lengths and pennation angles were measured via ultrasonography. Additionally, joint kinematics were analyzed to determine gastrocnemius medialis muscle–tendon unit lengths, consisting of the muscle's contractile and series elastic elements. Series elastic element length was assessed using a muscle–tendon unit model. Depending on whether data were normally distributed, a paired t-test or Wilcoxon signed rank test was performed to determine if body weight supported walking had any effects on joint kinematics and fascicle–series elastic element behavior. Walking with 30% body weight support had no statistically significant effect on joint kinematics and peak series elastic element length. Furthermore, at the time when peak series elastic element length was achieved, and on average across the entire stance phase, muscle–tendon unit length, fascicle length, pennation angle, and fascicle velocity were unchanged with respect to body weight support. In accordance with unchanged gait kinematics, preservation of fascicle–series elastic element behavior was observed during walking with 30% body weight support, which suggests transferability of gait patterns to subsequent unsupported walking.
The international partnership of space agencies has agreed to proceed forward to the Moon sustainably. Activities on the Lunar surface (0.16 g) will allow crewmembers to advance the exploration skills needed when expanding human presence to Mars (0.38 g). Whilst data from actual hypogravity activities are limited to the Apollo missions, simulation studies have indicated that ground reaction forces, mechanical work, muscle activation, and joint angles decrease with declining gravity level. However, these alterations in locomotion biomechanics do not necessarily scale to the gravity level, the reduction in gastrocnemius medialis activation even appears to level off around 0.2 g, while muscle activation pattern remains similar. Thus, it is difficult to predict whether gastrocnemius medialis contractile behavior during running on Moon will basically be the same as on Mars. Therefore, this study investigated lower limb joint kinematics and gastrocnemius medialis behavior during running at 1 g, simulated Martian gravity, and simulated Lunar gravity on the vertical treadmill facility. The results indicate that hypogravity-induced alterations in joint kinematics and contractile behavior still persist between simulated running on the Moon and Mars. This contrasts with the concept of a ceiling effect and should be carefully considered when evaluating exercise prescriptions and the transferability of locomotion practiced in Lunar gravity to Martian gravity.
The compliant nature of distal limb muscle-tendon units is traditionally considered suboptimal in explosive movements when positive joint work is required. However, during accelerative running, ankle joint net mechanical work is positive. Therefore, this study aims to investigate how plantar flexor muscle-tendon behavior is modulated during fast accelerations. Eleven female sprinters performed maximum sprint accelerations from starting blocks, while gastrocnemius muscle fascicle lengths were estimated using ultrasonography. We combined motion analysis and ground reaction force measurements to assess lower limb joint kinematics and kinetics, and to estimate gastrocnemius muscle-tendon unit length during the first two acceleration steps. Outcome variables were resampled to the stance phase and averaged across three to five trials. Relevant scalars were extracted and analyzed using one-sample and two-sample t-tests, and vector trajectories were compared using statistical parametric mapping. We found that an uncoupling of muscle fascicle behavior from muscle-tendon unit behavior is effectively used to produce net positive mechanical work at the joint during maximum sprint acceleration. Muscle fascicles shortened throughout the first and second steps, while shortening occurred earlier during the first step, where negative joint work was lower compared with the second step. Elastic strain energy may be stored during dorsiflexion after touchdown since fascicles did not lengthen at the same time to dissipate energy. Thus, net positive work generation is accommodated by the reuse of elastic strain energy along with positive gastrocnemius fascicle work. Our results show a mechanism of how muscles with high in-series compliance can contribute to net positive joint work.
Performing tasks, such as running and jumping, requires activation of the agonist and antagonist muscles before (motor unit pre-activation) and during movement performance (Santello and Mcdonagh, 1998). A well-timed and regulated muscle activation elicits a stretch-shortening cycle (SSC) response, naturally occurring in bouncing movements (Ishikawa and Komi, 2004; Taube et al., 2012). By definition, the SSC describes the stretching of a pre-activated muscle-tendon complex immediately followed by a muscle shortening in the concentric push-off phase (Komi, 1984).
Given the importance of SSC actions for human movement, it is not surprising that many studies investigated the biomechanics of this phenomenon; in particular, drop jumps (DJs) represent a good paradigm to study muscle fascicle and tendon behavior in ballistic movements involving the SSC.
Within a DJ, three main phases [pre-activation, braking, and push-off (PO; Komi, 2000)] have been recognized and extensively studied in common and challenging conditions, such as changes in load, falling height, or simulated hypo-gravity (Avela et al., 1994; Arampatzis et al., 2001; Fukashiro et al., 2005; Ishikawa et al., 2005; Sousa et al., 2007; Ritzmann et al., 2016; Helm et al., 2020).
These studies show that the timing and amount of triceps-surae muscle-tendon unit pre-activation in DJs are differentially regulated based on the load applied to the muscle, being optimal in normal “Earth” gravity conditions (Avela et al., 1994), but decreased in simulated hypo-gravity, hyper-gravity (Avela et al., 1994; Ritzmann et al., 2016), or unknown conditions (i.e., unknown falling heights; Helm et al., 2020). Some authors indicated that, when falling from heights different from the optimal one [defined as the drop height giving a maximum DJ performance indicated as peak ground reaction force (GRF) or jump high], electromyographic (EMG) activity of the plantar flexors increases from lower than optimal to higher than optimal heights (Ishikawa and Komi, 2004; Sousa et al., 2007).
These findings highlight the ability of the central nervous system to regulate the timing and amount of pre-activation according to different jumping conditions, thus regulating muscle fascicle length, tendon and joint stiffness as well as position, in order to safely land on the ground and quickly re-bounce.
Similarly, to pre-activation, also in the braking phase, the plantar flexors are differentially regulated. In optimal height (i.e., load) jumping conditions, gastrocnemius medialis (GM) fascicles shorten at early ground contact (possibly due to the intervention of the stretch reflex; Gollhofer et al., 1992) and behave quasi-isometrically in the late braking phase, enabling tendon elongation, and storage of elastic energy (Gollhofer et al., 1992; Fukashiro et al., 2005; Sousa et al., 2007). When increasing the falling height (augmenting the impact GRF), the quasi-isometric behavior of fascicles disappears, and fast fascicle lengthening occurs (Ishikawa et al., 2005; Sousa et al., 2007).
In the third and last PO phase, fascicles shorten and the tendon releases the elastic energy previously stored. Bobbert et al. (1987) reported no influence of jumping height on the work done and on the net vertical impulse assessed during PO; this observation suggests that, despite an optimal DJ performance might be achieved only in specific conditions (falling heights, loads), the central nervous system seems to be able to regulate muscle behavior in order to effectively perform the required task also in challenging situations.
Although the regulation of triceps-surae muscle-tendon unit in DJs has been extensively investigated, very few studies focused on sarcomeres behavior during the performance of this SSC movement (Kurokawa et al., 2003; Fukashiro et al., 2005, 2006). Sarcomeres represent muscle contractile units and are known to express different amounts of force depending on their length (Gordon et al., 1966; Walker and Schrodt, 1974); thus, understanding the time course of their responses during DJs is fundamental to gain further insights into muscle force-generating capacity. In vivo measurement of sarcomere length in humans has been so far been performed only in static positions and under highly controlled experimental conditions (Llewellyn et al., 2008; Sanchez et al., 2015). Instead, human sarcomere length estimation (achieved by dividing GM measured fascicle length for a fixed sarcomere number) in dynamic contractions provided an indirect measure of sarcomere operating range during squat jump, countermovement jump, and DJ (Fukashiro et al., 2005, 2006; Kurokawa et al., 2003). The results of these studies showed that sarcomeres operate in the ascending limb of their length-tension (L-T) relationship in all types of jumps, and particularly so in DJ.
However, most of the available observations on sarcomere and muscle fascicle behavior were made in condition of constant gravity. Thus, in order to understand how sarcomere and muscle fascicle length are regulated in variable gravity conditions, we performed experiments in a parabolic flight, involving variable gravity levels, ranging from about zero-g to about double the Earth’s gravity (1 g; Waldvogel et al., 2021).
Specifically, the aims of the present study were as follows:
1. To investigate the ability of the neuromuscular system in regulating fascicle length in response to conditions of variable gravity.
2. To estimate sarcomere operative length in the different DJ phases, in order to calculate its theoretical force production and its possible modulation in conditions of variable gravity.
We hypothesized that muscle fascicles would be differentially regulated in different gravity conditions compared to 1 g, particularly in anticipation of landing and re-bouncing in unknown gravity levels. In addition, we hypothesized that sarcomeres would operate in the upper part of the ascending limb of their L-T relationship, possibly lengthening during the braking phase (especially in hyper-gravity) while operating quasi-isometrically in 1 g.
Achilles tendon rupture (ATR) patients have persistent functional deficits in the triceps surae muscle–tendon unit (MTU). The complex remodeling of the MTU accompanying these deficits remains poorly understood. The purpose of the present study was to associate in vivo and in silico data to investigate the relations between changes inMTU properties and strength deficits inATR patients. Methods: Elevenmale subjects who had undergone surgical repair of complete unilateral ATR were examined 4.6 ± 2.0 (mean ± SD) yr after rupture. Gastrocnemius medialis (GM) tendon stiffness, morphology, and muscle architecture were determined using ultrasonography. The force–length relation of the plantar flexor muscles was assessed at five ankle joint angles. In addition, simulations (OpenSim) of the GM MTU force–length properties were performed with various iterations of MTU properties found between the unaffected and the affected side. Results: The affected side of the patients displayed a longer, larger, and stiffer GM tendon (13% ± 10%, 105% ± 28%, and 54% ± 24%, respectively) compared with the unaffected side. The GM muscle fascicles of the affected side were shorter (32% ± 12%) and with greater pennation angles (31% ± 26%). A mean deficit in plantarflexion moment of 31% ± 10% was measured. Simulations indicate that pairing an intact muscle with a longer tendon shifts the optimal angular range of peak force outside physiological angular ranges, whereas the shorter muscle fascicles and tendon stiffening seen in the affected side decrease this shift, albeit incompletely. Conclusions: These results suggest that the substantial changes in MTU properties found in ATR patients may partly result from compensatory remodeling, although this process appears insufficient to fully restore muscle function.
Dynamic retinal vessel analysis (DVA) provides a non-invasive way to assess microvascular function in patients and potentially to improve predictions of individual cardiovascular (CV) risk. The aim of our study was to use untargeted machine learning on DVA in order to improve CV mortality prediction and identify corresponding response alterations.
The recently discovered first hyperbolic objects passing through the Solar System, 1I/’Oumuamua and 2I/Borisov, have raised the question about near term missions to Interstellar Objects. In situ spacecraft exploration of these objects will allow the direct determination of both their structure and their chemical and isotopic composition, enabling an entirely new way of studying small bodies from outside our solar system. In this paper, we map various Interstellar Object classes to mission types, demonstrating that missions to a range of Interstellar Object classes are feasible, using existing or near-term technology. We describe flyby, rendezvous and sample return missions to interstellar objects, showing various ways to explore these bodies characterizing their surface, dynamics, structure and composition. Their direct exploration will constrain their formation and history, situating them within the dynamical and chemical evolution of the Galaxy. These mission types also provide the opportunity to explore solar system bodies and perform measurements in the far outer solar system.
Introduction: In peripheral percutaneous (VA) extracorporeal membrane oxygenation (ECMO) procedures the femoral arteries perfusion route has inherent disadvantages regarding poor upper body perfusion due to watershed. With the advent of new long flexible cannulas an advancement of the tip up to the ascending aorta has become feasible. To investigate the impact of such long endoluminal cannulas on upper body perfusion, a Computational Fluid Dynamics (CFD) study was performed considering different support levels and three cannula positions.
Methods: An idealized literature-based- and a real patient proximal aortic geometry including an endoluminal cannula were constructed. The blood flow was considered continuous. Oxygen saturation was set to 80% for the blood coming from the heart and to 100% for the blood leaving the cannula. 50% and 90% venoarterial support levels from the total blood flow rate of 6 l/min were investigated for three different positions of the cannula in the aortic arch.
Results: For both geometries, the placement of the cannula in the ascending aorta led to a superior oxygenation of all aortic blood vessels except for the left coronary artery. Cannula placements at the aortic arch and descending aorta could support supra-aortic arteries, but not the coronary arteries. All positions were able to support all branches with saturated blood at 90% flow volume.
Conclusions: In accordance with clinical observations CFD analysis reveals, that retrograde advancement of a long endoluminal cannula can considerably improve the oxygenation of the upper body and lead to oxygen saturation distributions similar to those of a central cannulation.
Introduction
In regard of surgical training, the reproducible simulation of life-like proximal humerus fractures in human cadaveric specimens is desirable. The aim of the present study was to develop a technique that allows simulation of realistic proximal humerus fractures and to analyse the influence of rotator cuff preload on the generated lesions in regards of fracture configuration.
Materials and methods
Ten cadaveric specimens (6 left, 4 right) were fractured using a custom-made drop-test bench, in two groups. Five specimens were fractured without rotator cuff preload, while the other five were fractured with the tendons of the rotator cuff preloaded with 2 kg each. The humeral shaft and the shortened scapula were potted. The humerus was positioned at 90° of abduction and 10° of internal rotation to simulate a fall on the elevated arm. In two specimens of each group, the emergence of the fractures was documented with high-speed video imaging. Pre-fracture radiographs were taken to evaluate the deltoid-tuberosity index as a measure of bone density. Post-fracture X-rays and CT scans were performed to define the exact fracture configurations. Neer’s classification was used to analyse the fractures.
Results
In all ten cadaveric specimens life-like proximal humerus fractures were achieved. Two III-part and three IV-part fractures resulted in each group. The preloading of the rotator cuff muscles had no further influence on the fracture configuration. High-speed videos of the fracture simulation revealed identical fracture mechanisms for both groups. We observed a two-step fracture mechanism, with initial impaction of the head segment against the glenoid followed by fracturing of the head and the tuberosities and then with further impaction of the shaft against the acromion, which lead to separation of the tuberosities.
Conclusion
A high energetic axial impulse can reliably induce realistic proximal humerus fractures in cadaveric specimens. The preload of the rotator cuff muscles had no influence on initial fracture configuration. Therefore, fracture simulation in the proximal humerus is less elaborate. Using the presented technique, pre-fractured specimens are available for real-life surgical education.