Refine
Year of publication
Document Type
- Article (5464)
- Conference Proceeding (1393)
- Book (1056)
- Part of a Book (544)
- Patent (172)
- Bachelor Thesis (156)
- Report (81)
- Doctoral Thesis (78)
- Other (68)
- Contribution to a Periodical (19)
- Master's Thesis (17)
- Review (17)
- Working Paper (8)
- Talk (5)
- Habilitation (4)
- Preprint (4)
- Diploma Thesis (3)
- Poster (3)
- Part of Periodical (2)
- Examination Thesis (1)
- Video (1)
Language
Has Fulltext
- no (9096) (remove)
Keywords
- Corporate Design (9)
- Illustration (9)
- Erscheinungsbild (8)
- Gamification (8)
- Nachhaltigkeit (8)
- Redesign (7)
- Animation (6)
- Datenschutz (6)
- Digitalisierung (6)
- avalanche (6)
- App (5)
- Earthquake (5)
- Editorial (5)
- Enterprise Architecture (5)
- Fotografie (5)
- Geschichte (5)
- MINLP (5)
- solar sail (5)
- Aktionskunst (4)
- Design (4)
Institute
- Fachbereich Medizintechnik und Technomathematik (1907)
- Fachbereich Elektrotechnik und Informationstechnik (1116)
- Fachbereich Wirtschaftswissenschaften (1100)
- Fachbereich Energietechnik (1056)
- Fachbereich Chemie und Biotechnologie (829)
- Fachbereich Maschinenbau und Mechatronik (799)
- Fachbereich Luft- und Raumfahrttechnik (749)
- Fachbereich Bauingenieurwesen (658)
- IfB - Institut für Bioengineering (623)
- INB - Institut für Nano- und Biotechnologien (584)
- Solar-Institut Jülich (334)
- Fachbereich Gestaltung (333)
- Fachbereich Architektur (161)
- ECSM European Center for Sustainable Mobility (106)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (66)
- Nowum-Energy (64)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (62)
- Institut fuer Angewandte Polymerchemie (32)
- Sonstiges (24)
- IBB - Institut für Baustoffe und Baukonstruktionen (21)
Application of the optical flow method to velocity determination in hydraulic structure models
(2016)
The aim of this work was to perform a detailed investigation of the use of Selective Laser Melting (SLM) technology to process eutectic silver-copper alloy Ag 28 wt. % Cu (also called AgCu28). The processing occurred with a Realizer SLM 50 desktop machine. The powder analysis (SEM-topography, EDX, particle distribution) was reported as well as the absorption rates for the near-infrared (NIR) spectrum. Microscope imaging showed the surface topography of the manufactured parts. Furthermore, microsections were conducted for the analysis of porosity. The Design of Experiments approach used the response surface method in order to model the statistical relationship between laser power, spot distance and pulse time.
Für das Auftreten extremer Wetterereignisse werden für Kernkraftwerke Eintrittshäufigkeiten für nicht mehr beherrschbare Zustände von unter 10⁻⁴/a gefordert. Dies gilt auch für die Einwirkung von Blitzeinschlägen. Die bisherige Nachweisführung zu Blitz- und Überspannungsschutz eines KKW in Deutschland ist deterministisch. In diesem Bericht werden das Vorgehen für einen entsprechenden Nachweis für leittechnische Einrichtungen der Sicherheitstechnik von KKW, der zur geforderten Zielgröße der Eintrittshäufigkeit führt. Die Ergebnisse werden zusammenfassend bewertet.
In Anbetracht weltweit zunehmend strengerer klimapolitischer
Ziele steigt auch der Druck für Nutzfahrzeughersteller, effizientere und umweltfreundlichere
Technologien zu entwickeln. Den Blick bei der Bewertung dieser
ausschließlich auf die Fahrzeugnutzung zu richten, ist längst nicht mehr zufriedenstellend.
Im Rahmen dieser Analyse wird ein gegenwärtig auf dem Markt erwerblicher
und in deutschen Städten bereits seit Jahren betriebener Hybridbus
energetisch und ökologisch mit einem konventionell angetriebenen, nahezu baugleichen
Modell entlang des Lebensweges bewertet.
Nach Definition von Ziel und Untersuchungsrahmen wird ein Überblick auf bereits
durchgeführte Lebenszyklusanalysen zu Hybridbussen im Stadtverkehr gegeben
und Schlussfolgerungen für die anschließende Analyse abgeleitet. Diese
wird im Rahmen einer energetischen und ökologischen Bewertung beider Produktsysteme
anhand der Parameter "Primärenergieeinsatz" und "CO2äq Emissionen"
praktiziert. Der Fahrzeugrumpf beider Fahrzeuge des gleichen Modells
wird dabei als einheitlich angenommen, sodass bei dem Vergleich der Herstellung
vereinfacht nur die sich unterscheidenden Komponenten des Antriebstranges
berücksichtigt werden. Die Resultate der Wirkungsabschätzung werden als
Differenz des Hybridbusses gegenüber dem Referenzfahrzeug über die einzelnen
Lebenszyklusphasen dargestellt. Schließlich werden Prognosen getroffen, ab
welcher Strecke die bei der Herstellung erzeugten höheren CO2äq Emissionen
des Hybridantriebstranges gegenüber dem Referenzmodell ausgeglichen werden.
Mit der vorliegenden, parallel entsprechend in 10 weiteren Verfahren ergangenen Entscheidung behandelte der BGH zum wiederholten Male das Geschäftsmodell der Accessio Wertpapierhandelshaus AG („A AG“, früher: Wertpapierhandelshaus Driver & Bengsch AG). Die klagenden Anleger, zunächst nur akquiriert durch ein Tagesgeldkonto mit besonders attraktiven Zinsen, schlossen im Weiteren mit dieser einen Vermögensverwaltungsvertrag ab. Zur Abwicklung der Wertpapiergeschäfte eröffneten sie über die A AG zugleich ein Depotkonto bei der beklagten Discount-Brokerin. Für dieses erhielt die A AG eine Transaktionsvollmacht. Die Discount-Brokerin schuldete nach den Vertragsdokumenten über die gesetzlichen Aufklärungs- und Erkundigungspflichten bei Auftragsausführung hinaus keine Anlageberatung („execution-only-business“). Durch nach ihrer Behauptung fehlerhafte Anlageberatung der A AG erlitten die Anleger einen Schaden. In dem Rechtsstreit verlangten sie dessen Ersatz von der Discount-Brokerin, da die A AG zwischenzeitlich insolvent wurde.
Retinal Vessel Analysis (RVA) in the context of subarachnoid hemorrhage: A proof of concept study
(2016)
Background
Timely detection of impending delayed cerebral ischemia after subarachnoid hemorrhage (SAH) is essential to improve outcome, but poses a diagnostic challenge. Retinal vessels as an embryological part of the intracranial vasculature are easily accessible for analysis and may hold the key to a new and non-invasive monitoring technique. This investigation aims to determine the feasibility of standardized retinal vessel analysis (RVA) in the context of SAH.
Methods
In a prospective pilot study, we performed RVA in six patients awake and cooperative with SAH in the acute phase (day 2–14) and eight patients at the time of follow-up (mean 4.6±1.7months after SAH), and included 33 age-matched healthy controls. Data was acquired using a manoeuvrable Dynamic Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and neurovascular coupling.
Results
Image quality was satisfactory in the majority of cases (93.3%). In the acute phase after SAH, retinal arteries were significantly dilated when compared to the control group (124.2±4.3MU vs 110.9±11.4MU, p<0.01), a difference that persisted to a lesser extent in the later stage of the disease (122.7±17.2MU, p<0.05). Testing for neurovascular coupling showed a trend towards impaired primary vasodilation and secondary vasoconstriction (p = 0.08, p = 0.09 resp.) initially and partial recovery at the time of follow-up, indicating a relative improvement in a time-dependent fashion.
Conclusion
RVA is technically feasible in patients with SAH and can detect fluctuations in vessel diameter and autoregulation even in less severely affected patients. Preliminary data suggests potential for RVA as a new and non-invasive tool for advanced SAH monitoring, but clinical relevance and prognostic value will have to be determined in a larger cohort.
The conjunction of (bio-)chemical recognition elements with nanoscale biological building blocks such as virus particles is considered as a very promising strategy for the creation of biohybrids opening novel opportunities for label-free biosensing. This work presents a new approach for the development of biosensors using tobacco mosaic virus (TMV) nanotubes or coat proteins (CPs) as enzyme nanocarriers. Sensor chips combining an array of Pt electrodes loaded with glucose oxidase (GOD)-modified TMV nanotubes or CP aggregates were used for amperometric detection of glucose as a model system for the first time. The presence of TMV nanotubes or CPs on the sensor surface allows binding of a high amount of precisely positioned enzymes without substantial loss of their activity, and may also ensure accessibility of their active centers for analyte molecules. Specific and efficient immobilization of streptavidin-conjugated GOD ([SA]-GOD) complexes on biotinylated TMV nanotubes or CPs was achieved via bioaffinity binding. These layouts were tested in parallel with glucose sensors with adsorptively immobilized [SA]-GOD, as well as [SA]-GOD crosslinked with glutardialdehyde, and came out to exhibit superior sensor performance. The achieved results underline a great potential of an integration of virus/biomolecule hybrids with electronic transducers for future applications in biosensorics and biochips.
Hintergrund
Die Anwendung und das Verständnis von Statistik sind sehr wichtig für die biomedizinische Forschung und für die klinische Praxis. Dies gilt insbesondere auch zur Abschätzung der Möglichkeiten unterschiedlichster Diagnostik- und Therapieoptionen beim Glaukom. Die scheinbare Komplexität der Statistik, die zum Teil dem „gesunden Menschenverstand“ zu widersprechen scheint, zusammen mit der nur vorsichtigen Akzeptanz der Statistik bei vielen Medizinern können zu bewussten und unbewussten Manipulationen bei der Datendarstellung und -interpretation führen.
Ziel der Arbeit
Ziel ist die verständliche Darstellung einiger typischer Fehler in der medizinisch-statistischen Datenbehandlung.
Material und Methoden
Anhand hypothetischer Beispiele aus der Glaukomdiagnostik erfolgen die Darstellung der Wirkung eines hypotensiven Medikamentes sowie die Beurteilung der Ergebnisse eines diagnostischen Tests. Es werden die typischsten statistischen Einsatzbereiche und Irrtumsquellen ausführlich und verständlich analysiert
Ergebnisse
Mechanismen von Datenmanipulation und falscher Dateninterpretation werden aufgeklärt. Typische Irrtumsquellen bei der statistischen Auswertung und Datendarstellung werden dabei erläutert.
Schlussfolgerungen
Die erläuterten praktischen Beispiele zeigen die Notwendigkeit, die Grundlagen der Statistik zu verstehen und korrekt anwenden zu können. Fehlendes Grundlagenwissen und Halbwissen der medizinischen Statistik können zu folgenschweren Missverständnissen und falschen Entscheidungen in der medizinischen Forschung, aber auch in der klinischen Praxis führen.
Four members of a homologous series of chlorinated poly(vinyl ester) oligomers CCl₃–(CH₂CH (OCO(CH₂)ₘCH₃))ₙ–Cl with degrees of polymerization of 10 and 20 were prepared by telomerisation using carbon tetrachloride. The number of side chain carbon atoms ranges from 2 (poly(vinyl acetate) to 18 (poly(vinyl stearate)). The effect of the n-alkyl side chain length and of the degree of polymerization on the thermal stability and crystallization behaviour of the synthesized compounds was investigated.
All oligomers degrade in two major steps by first losing HCl and side chains with subsequent breakdown of the backbone. The members with short side chains, up to poly(vinyl octanoate), are amorphous and show internal plasticization, whereas those with high number of side chain carbon atoms are semi-crystalline due to side-chain crystallization. A better packing for poly(vinyl stearate) is also noticeable. The glass transition and melting temperatures as well as the onset temperature of decomposition are influenced to a larger extent by the side chain length than by the degree of polymerization. Thermal stability is improved if both the size and number of side chains increase, but only a long side chain causes a significant increase of the resistance to degradation. This results in a stabilization of PVAc so that oligomers from poly(vinyl octanoate) on are stable under atmospheric conditions. Thus, the way to design stable, chlorinated PVEs oligomers is to use a long n-alkyl side chain.
Today, the assembly of laser systems requires a large share of manual operations due to its complexity regarding the optimal alignment of optics. Although the feasibility of automated alignment of laser optics has been shown in research labs, the development effort for the automation of assembly does not meet economic requirements – especially for low-volume laser production. This paper presents a model-based and sensor-integrated assembly execution approach for flexible assembly cells consisting of a macro-positioner covering a large workspace and a compact micromanipulator with camera attached to the positioner. In order to make full use of available models from computer-aided design (CAD) and optical simulation, sensor systems at different levels of accuracy are used for matching perceived information with model data. This approach is named "chain of refined perception", and it allows for automated planning of complex assembly tasks along all major phases of assembly such as collision-free path planning, part feeding, and active and passive alignment. The focus of the paper is put on the in-process image-based metrology and information extraction used for identifying and calibrating local coordinate systems as well as the exploitation of that information for a part feeding process for micro-optics. Results will be presented regarding the processes of automated calibration of the robot camera as well as the local coordinate systems of part feeding area and robot base.