Refine
Year of publication
- 2002 (232) (remove)
Document Type
- Article (166)
- Book (32)
- Conference Proceeding (25)
- Part of a Book (3)
- Patent (3)
- Doctoral Thesis (1)
- Report (1)
- Review (1)
Has Fulltext
- no (232) (remove)
Keywords
- Energierecht (1)
- Erneuerbares Energiengesetz (1)
- Kohlefeuerung (1)
- Reduktion <Chemie> (1)
- Rohrreaktor (1)
- Stickstoffoxide (1)
- Wirbelschichtfeuerung (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (53)
- Fachbereich Elektrotechnik und Informationstechnik (29)
- Fachbereich Wirtschaftswissenschaften (29)
- Fachbereich Energietechnik (27)
- Fachbereich Luft- und Raumfahrttechnik (21)
- Fachbereich Maschinenbau und Mechatronik (21)
- Fachbereich Chemie und Biotechnologie (18)
- INB - Institut für Nano- und Biotechnologien (18)
- IfB - Institut für Bioengineering (12)
- Solar-Institut Jülich (10)
- Fachbereich Bauingenieurwesen (8)
- Fachbereich Architektur (7)
- Fachbereich Gestaltung (7)
- Nowum-Energy (1)
Coincident events in two scintillator crystals coupled to photomultipliers (PMT) are detected by processing just the digital data of the recorded pulses. For this purpose the signals from both PMTs are continuously sampled by free-running ADCs at a sampling rate of 40 MHz. For each sampled pulse the starting time is determined by processing the pulse data. Even a fairly simple interpolating algorithm results in a FWHM of about 2 ns.
Within the developments for the Crystal Clear small animal PET project (CLEARPET) a dual head PET system has been established. The basic principle is the early digitization of the detector pulses by free running ADCs. The determination of the γ-energy and also the coincidence detection is performed by data processing of the sampled pulses on the host computer. Therefore a time mark is attached to each pulse identifying the current cycle of the 40 MHz sampling clock. In order to refine the time resolution the pulse starting time is interpolated from the samples of the pulse rise. The detector heads consist of multichannel PMTs with a single LSO scintillator crystal coupled to each channel. For each PMT only one ADC is required. The position of an event is obtained separately from trigger signals generated for each single channel. An FPGA is utilized for pulse buffering, generation of the time mark and for the data transfer to the host via a fast I/O-interface.
Rezension zu: K. Zimmermann, Technische Mechanik – multimedial. Fachbuch Verlag Leipzig (2000)
(2002)
Macroporous silicon has been etched from n-type Si, using a vertical etching cell where no rear side contact on the silicon wafer is necessary. The resulting macropores have been characterised by means of Scanning Electron Microscopy (SEM). After etching, SiO₂ was thermally grown on the top of the porous silicon as an insulating layer and Si₃N₄ was deposited by means of Low Pressure Chemical Vapour Deposition (LPCVD) as transducer material to fabricate a capacitive pH sensor. In order to prepare porous biosensors, the enzyme penicillinase has been additionally immobilised inside the porous structure. Electrochemical measurements of the pH sensor and the biosensor with an Electrolyte/Insulator/Semiconductor (EIS) structure have been performed in the Capacitance/Voltage (C/V) and Constant capacitance (ConCap) mode.
Gute Chancen im Maschinenbau
(2002)
Gute Chancen im Maschinenbau
(2002)
Chancen im Maschinenbau
(2002)