Article
Refine
Year of publication
- 2022 (2)
- 2021 (4)
- 2020 (4)
- 2019 (4)
- 2018 (1)
- 2017 (3)
- 2015 (1)
- 2014 (3)
- 2013 (1)
- 2012 (2)
- 2011 (1)
- 2010 (1)
- 2009 (3)
- 2008 (2)
- 2007 (2)
- 2006 (1)
- 2005 (8)
- 2004 (2)
- 2003 (3)
- 2002 (4)
- 2001 (1)
- 2000 (3)
- 1999 (3)
- 1998 (3)
- 1997 (2)
- 1996 (5)
- 1995 (4)
- 1994 (7)
- 1993 (2)
- 1992 (1)
- 1991 (3)
- 1990 (1)
- 1989 (3)
- 1988 (1)
- 1987 (1)
- 1986 (2)
- 1985 (2)
- 1984 (1)
- 1983 (1)
- 1982 (1)
- 1981 (1)
- 1980 (2)
- 1979 (1)
- 1978 (2)
- 1977 (2)
Institute
- Solar-Institut Jülich (107) (remove)
Document Type
- Article (107) (remove)
Keywords
- Haustechnik (2)
- Heizung (2)
- Klimatechnik (2)
- Lüftung (2)
- Lüftungstechnik (2)
- Abluft (1)
- Dynamic simulation (1)
- Mischen (1)
- Modelica (1)
- Molten salt receiver system (1)
Regenerative Energiequellen
(1995)
Globale Betrachtung regenerativer Energieressourcen und deren technischer Nutzungsmöglichkeiten
(1995)
Regenerative Energiequellen
(1991)
Regenerative Energiequellen
(1989)
Regenerative Energiequellen
(1988)
Regenerative Energiequellen
(1986)
Regenerative Energiequellen
(1987)
Regenerative Energiequellen
(1985)
Regenerative Energiequellen
(1984)
Regenerative Energiequellen
(1983)
Regenerative Energiequellen
(1982)
Regenerative Energiequellen
(1981)
Regenerative Energiequellen
(1979)
Regenerative Energiequellen
(1978)
This paper describes the modeling of a high-temperature storage system for an existing solar tower power plant with open volumetric receiver technology, which uses air as heat transfer medium (HTF). The storage system model has been developed in the simulation environment Matlab/Simulink®. The storage type under investigation is a packed bed thermal energy storage system which has the characteristics of a regenerator. Thermal energy can be stored and discharged as required via the HTF air. The air mass flow distribution is controlled by valves, and the mass flow by two blowers. The thermal storage operation strategy has a direct and significant impact on the energetic and economic efficiency of the solar tower power plants.
In co-operation with the German Aerospace Center, the Solar-Institut Jülich has been analyzing the different technologies that are available for methanol production from CO2 using solar energy. The aim of the project is to extract CO2 from industrial exhaust gases or directly from the atmosphere to recycle it by use of solar energy. Part of the study was the modeling and simulating of a methane reformer for the production of synthesis gas, which can be operated by solar or hybrid heat sources. The reformer has been simplified in such a way that the model is accurate and enables fast calculations. The developed pseudo-homogeneous one- dimensional model can be regarded as a kind of counter-current heat exchanger and is able to incorporate a steam reforming reaction as well as a dry reforming reaction.
Speicher statt Kohle. Integration thermischer Stromspeicher in vorhandene Kraftwerksstandorte
(2019)
This study focuses on thermoelectric elements (TEE) as an alternative for room temperature control. TEE are semi-conductor devices that can provide heating and cooling via a heat pump effect without direct noise emissions and no refrigerant use. An efficiency evaluation of the optimal operating mode is carried out for different numbers of TEE, ambient temperatures, and heating loads. The influence of an additional heat recovery unit on system efficiency and an unevenly distributed heating demand are examined. The results show that TEE can provide heat at a coefficient of performance (COP) greater than one especially for small heating demands and high ambient temperatures. The efficiency increases with the number of elements in the system and is subject to economies of scale. The best COP exceeds six at optimal operating conditions. An additional heat recovery unit proves beneficial for low ambient temperatures and systems with few TEE. It makes COPs above one possible at ambient temperatures below 0 ∘C. The effect increases efficiency by maximal 0.81 (from 1.90 to 2.71) at ambient temperature 5 K below room temperature and heating demand Q˙h=100W but is subject to diseconomies of scale. Thermoelectric technology is a valuable option for electricity-based heat supply and can provide cooling and ventilation functions. A careful system design as well as an additional heat recovery unit significantly benefits the performance. This makes TEE superior to direct current heating systems and competitive to heat pumps for small scale applications with focus on avoiding noise and harmful refrigerants.
Advanced window systems and building energy performance / S. Reilly ; J. Göttsche ; V. Wittwer
(1991)
Analyse der Studentenwohnungen des Solar-Campus Jülich / Göttsche, Joachim ; Gabrysch, Karten
(2001)
Simulationsprogramme in der Solarenergie-Ausbildung / Blum, K. ; Göttsche, J. ; Schumacher, J.
(1994)
The optical performance of a 2-axis solar concentrator was simulated with the COMSOL Multiphysics® software. The concentrator consists of a mirror array, which was created using the application builder. The mirror facets are preconfigured to form a focal point. During tracking all mirrors are moved simultaneously in a coupled mode by 2 motors in two axes, in order to keep the system in focus with the moving sun. Optical errors on each reflecting surface were implemented in combination with the solar angular cone of ± 4.65 mrad. As a result, the intercept factor of solar radiation that is available to the receiver was calculated as a function of the transversal and longitudinal angles of incidence. In addition, the intensity distribution on the receiver plane was calculated as a function of the incidence angles.