Conference Proceeding
Refine
Year of publication
- 2010 (100) (remove)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (19)
- Fachbereich Medizintechnik und Technomathematik (14)
- Fachbereich Energietechnik (13)
- Fachbereich Maschinenbau und Mechatronik (12)
- Fachbereich Bauingenieurwesen (11)
- Solar-Institut Jülich (11)
- Fachbereich Luft- und Raumfahrttechnik (10)
- IfB - Institut für Bioengineering (8)
- INB - Institut für Nano- und Biotechnologien (5)
- Fachbereich Architektur (3)
Language
- English (68)
- German (30)
- Italian (1)
- Multiple languages (1)
Document Type
- Conference Proceeding (100) (remove)
Keywords
- humans (2)
- Dekontamination (1)
- Endothelzelle (1)
- Erythrozyt (1)
- Graduiertentagung (1)
- Hämoglobin (1)
- Körpertemperatur (1)
- Natriumhypochlorit (1)
- Sepsis (1)
- Sonde (1)
Ein lichtadressierbarer potentiometrischer Sensor (LAPS) kann die Konzentration eines oder mehrerer Analyten ortsaufgelöst auf der Sensoroberfläche nachweisen. Dazu wird mit einer modulierten Lichtquelle die Halbleiterstruktur des zu untersuchenden Bereiches angeregt und ein entsprechender Photostrom ausgelesen. Durch gleichzeitige Anregung mehrere Bereiche durch Lichtquellen mit unterschiedlichen Modulationsfrequenzen können diese auch zeitgleich ausgelesen werden. Mit der neuen, hier vorgestellten Ansteuerungselektronik integriert in einem "Field Programmable Gate Array" (FPGA) ist es möglich, mehrere Leuchtquellen gleichzeitig mit unterschiedlichen, während der Laufzeit festlegbaren Frequenzen, Phasen und Lichtintensitäten zu betreiben. Somit kann das Frequenzverhalten des Sensors untersucht und die Konzentration des Analyten über das Oberflächenpotential mit Hilfe von Strom/Spannungs-Kurven und Phase/Spannungs-Kurven bestimmt werden.
The determination of spacing, edge and end distance requirements for self-tapping screws requires numerous and comprehensive insertion tests. Yet the results of such tests cannot be transferred to other types of screws or even to screws of different diameter because of differences in shape or geometry. To reduce the effort of insertion tests a new method was developed which allows the estimation of required spacings, distances and timber thickness.
Shakedown analysis of two dimensional structures by an edge-based smoothed finite element method
(2010)
Doktoranden der FH Aachen stellen ihre wissenschaftlichen Arbeiten aus verschiedenen Fachdisziplinen vor.
Die vorliegende Arbeit zeichnet sich dadurch aus, dass registrierte unsegmentierte Volumina aus multimodalen Bilddatensätzen (z.B. MRT, PET) gleichzeitig in einer 3D-Rekonstruktion visualisiert werden und in Echtzeit manipuliert werden können. Ermöglicht wird die Echtzeitfähigkeit durch die Programmierung der Algorithmen zur direkten Volumenvisualisierung auf der Grafikkarte mittels der neuen CUDA-Technologie. Die Zuordnung der Farbeigenschaften wird über 1D-Transferfunktionen für jedes Volumen getrennt gesteuert. So können durch die interaktive Veränderung der 1D-Transferfunktion Detailinformationen aus den zwei Bilddatensätzen getrennt kontrolliert werden und die Vorteile der verschiedenen Bildmodalitäten in einer Visualisierung genutzt werden. Mittels dieses interaktiven Frameworks können neue Erkenntnisse insbesondere über neurodegenerativen Erkrankungen gewonnen werden.
In steps of the production chain of carbide inserts, such as unloading or packaging, the conformity test of the insert type is done manually, which causes a statistic increase of errors due to monotony and fatigue of the worker and the wide variety of the insert types. A machine vision system is introduced that captures digital frames of the inserts in the production line, analyses inspects automatically and measures four quality features: coating colour, edge radius, plate shape and chip-former geometry. This new method has been tested on several inserts of different types and has shown that the prevalent insert types can be inspected and robustly classified in real production environment and therefore improves the manufacturing automation.
Energiebilanzen und -potenziale von Abwasseranlagen : Vorstellung neuer Untersuchungsvorhaben in NRW
(2010)
We propose a formalism for reasoning about actions based on multi-modal logic which allows for expressing observations as first-class objects. We introduce a new modal operator, namely [o |α], which allows us to capture the notion of perceiving an observation given that an action has taken place. Formulae of the type [o |α]ϕ mean ’after perceiving observation o, given α was performed, necessarily ϕ’. In this paper, we focus on the challenges concerning sensing with explicit observations, and acting with nondeterministic effects. We present the syntax and semantics, and a correct and decidable tableau calculus for the logic
With the final objective of optimizing the "Micromix" hydrogen combustion principle, a round jet in a laminar cross-flow prior to its combustion is investigated experimentally using Stereoscopic Particle Image Velocimetry. Measurements are performed at a jet to cross-stream momentum ratio of 1 and a Reynolds number, based on the jet diameter and jet velocity, of 1600. The suitability to combine side, top and end views is analyzed statistically. The statistical theory of testing hypotheses, pertaining to the joint distribution of the averaged velocity along intersecting observation planes, is employed. Overall, the averaged velocity fields of the varying observation planes feature homogeneity at a 0.05 significance level. Minor discrepancies are related to the given experimental conditions. By use of image maps, averaged and instantaneous velocity fields, an attempt is made to elucidate the flow physics and a kinematically consistent vortex model is proposed. In the time-averaged flow field, the principal vortical systems were identified and the associated mixing visualized. The jet trajectory and physical dimensions scale with the momentum ratio times the jet diameter. The jet/cross-flow mixture converging upon the span-wise centre-line, the lifting action of the Counter Rotating Vortex Pair and the reversed flow region contribute to the high entrainment and mixedness. It is shown that the jet width is larger on the downstream side as compared to the upstream side of the centre-streamline. The deepest penetration of the particles on the outer boundary occurs in the centre-plane. Meanwhile, with increasing off-centre position, the boundaries all lay further from the centre-line position than does the boundary in the centre-plane, corresponding to a kidney-like shape of the flow cross-section. The generation of the Counter Rotating Vortex Pair and the instability mechanism is documented by instantaneous image maps and vector fields. The necessary circulation for the Counter Rotating Vortex Pair originates from a combined effect of steady in-hole, hanging and wake vortices. The strong cross-flow and jet interaction induces a three-dimensional waving, the stream-wise Counter Rotating Vortex Pair pair, leading to the formation of Ring Like Vortices. A secondary Counter Rotating Vortex Pair forms on top of the primary Counter Rotating Vortex Pair, resulting in mixing by "puffs". Overall, Stereoscopic Particle Image Velocimetry proofed capable of elucidating the Jet in Cross-Flow complex flow field. The gained insight in the mixing process will definitely contribute to the "Micromix" hydrogen combustion optimization.
Es wurde ein automatisiertes, computerunterstütztes Testsystem für die Funktionsprüfung und Charakterisierung von (bio-)chemischen Sensoren auf Waferebene entwickelt und in einen konventionellen Spitzenmessplatz integriert. Das System ermöglicht die Charakterisierung und Identifizierung „funktionstauglicher“ Sensoren bereits auf Waferebene zwischen den einzelnen Herstellungsschritten, wodurch weitere, bisher übliche Verarbeitungsschritte wie das Fixieren, Bonden und Verkapseln für die defekten oder nicht funktionstauglichen Sensorstrukturen entfällt. Außerdem bietet eine speziell entworfene miniaturisierte Durchflussmesszelle die Möglichkeit, bereits auf Waferlevel die Sensitivität, Drift, Hysterese und Ansprechzeit der (bio-)chemischen Sensoren zu charakterisieren. Das System wurde exemplarisch mit kapazitiven, pH-sensitiven EIS- (Elektrolyt-Isolator-Silizium) Strukturen und ISFET- (ionensensitiver Feldeffekttransistor) Strukturen mit verschiedenen Geometrien und Gate-Layouts getestet.
The high-level decision making process of an autonomous robot can be seen as an hierarchically organised entity, where strategical decisions are made on the topmost layer, while the bottom layer serves as driver for the hardware. In between is a layer with monitoring and reporting functionality. In this paper we propose a behaviour engine for this middle layer which, based on formalism of hybrid state machines (HSMs), bridges the gap between high-level strategic decision making and low-level actuator control. The behaviour engine has to execute and monitor behaviours and reports status information back to the higher level. To be able to call the behaviours or skills hierarchically, we extend the model of HSMs with dependencies and sub-skills. These Skill-HSMs are implemented in the lightweight but expressive Lua scripting language which is well-suited to implement the behaviour engine on our target platform, the humanoid robot Nao.
The idea of component-based software engineering was proposed more that 40 years ago, yet only few robotics software frameworks follow these ideas. The main problem with robotics software usually is that it runs on a particular platform and transferring source code to another platform is crucial. In this paper, we present our software framework Fawkes which follows the component-based software design paradigm by featuring a clear component concept with well-defined communication interfaces. We deployed Fawkes on several different robot platforms ranging from service robots to biped soccer robots. Following the component concept with clearly defined communication interfaces shows great benefit when porting robot software from one robot to the other. Fawkes comes with a number of useful plugins for tasks like timing, logging, data visualization, software configuration, and even high-level decision making. These make it particularly easy to create and to debug productive code, shortening the typical development cycle for robot software.
In aseptischen Abfüllsystemen wird Wasserstoffperoxid in der Gasphase aufgrund der stark oxidativen Wirkung zur Packstoffentkeimung eingesetzt. Dabei wird die Effizienz der Entkeimung im Wesentlichen von der vorliegenden H2O2-Konzentration im Packstoff bestimmt. Zur Inline-Überwachung der H2O2-Konzentration wurde ein kalorimetrischer Gassensor auf Basis einer flexiblen Polyimidfolie aus temperatursensitiven Dünnschicht-Widerständen und Mangan(IV)-oxid als katalytische Transducerschicht realisiert. Der Sensor weist ein lineares Ansprechverhalten mit einer Sensitivität von 7,15 °C/Vol.-% in einem H2O2-Konzentrationsbereich von 0 bis 8 Vol.-% auf. Weiterhin wurde zur Auslesung des Sensorsignals eine RFID-Elektronik, bestehend aus einem Sensor-Tag und einer Sende-/Empfangseinheit ausgelegt, sowie eine Abfolge des Messzyklus aufgestellt. Im weiteren Verlauf soll der kalorimetrische Gassensor mit der RFID-Elektronik gekoppelt und in eine Testverpackung zur Inline-Überwachung der H2O2-Konzentration in aseptischen Abfüllsystemen implementiert werden.
Planning the air-terminations for a structure to be protected the use of the rolling-sphere method (electro-geometrical model) is the best way from the physics of lightning point-of-view. Therefore, international standards prefer this method. However, using the rolling-sphere method only results in possible point-of-strikes on a structure without giving information about the probability of strikes at the individual points compared to others.