Refine
Year of publication
- 2004 (161) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (75)
- INB - Institut für Nano- und Biotechnologien (32)
- IfB - Institut für Bioengineering (28)
- Fachbereich Energietechnik (25)
- Fachbereich Elektrotechnik und Informationstechnik (19)
- Fachbereich Luft- und Raumfahrttechnik (16)
- Fachbereich Chemie und Biotechnologie (8)
- Fachbereich Maschinenbau und Mechatronik (5)
- Freshman Institute (4)
- Solar-Institut Jülich (4)
Language
- English (161) (remove)
Document Type
- Article (131)
- Conference Proceeding (22)
- Book (7)
- Part of a Book (1)
Keywords
- Bauingenieurwesen (2)
- CAD (2)
- Elektromagnetischer Schutzschild (2)
- civil engineering (2)
- Audio-visual Art (1)
- Blitz (1)
- Blitzrisiko (1)
- Blitzschlag (1)
- Blitzschutz (1)
- Direct lightning strike (1)
Improved collapse loads of thick-walled, crack containing pipes and vessels are suggested. Very deep cracks have a residual strength which is better modelled by a global limit load. In all burst tests, the ductility of pressure vessel steels was sufficiently high whereby the burst pressure could be predicted by limit analysis with no need to apply fracture mechanics. The relative prognosis error increases however, for long and deep defects due to uncertainties of geometry and strength data.
Novel balanced inductor for compact differential systems / Sadeghfam, Arash; Heuermann, Holger
(2004)
For the application of the concept of Lightning Protection Zones (LPZ), the knowledge of the magnetic fields and induced voltages inside a structure is necessary. Laboratory experiments have been conducted at a downscaled model of a building (scale factor 1:6) to determine these electromagnetic quantities in case of a direct strike to the structure. The model (3 m x 2 m x 2 m) represented a small industrial building using the reinforcement of the concrete as electromagnetic shield. The magnetic fields and magnetic field derivatives were measured at several location inside the scaled model. Further, the voltages induced on three typical cable routes inside the model was determined. The influence of the lightning current waveshape, point-of-strike, bonding of the cable routes, and bridging of an expansion joint in the middle of the building on these quantities was studied.
In the paper the results obtained from experiments at a modelled reinforced building in case of a direct lightning strike are compared with calculations. The comparison includes peak values of the magnetic field Hmax, its derivative (dH/dt)max and of induced voltages umax in typical cable routings. The experiments are performed at a 1:6 scaled building and the results are extrapolated using the similarity relations theory. The calculations are based on the approximate formulae given in IEC 62305-4 and have to be supplemented by a rough estimation of the additional shielding effect of a second reinforcement layer. The comparison shows, that the measured peak values of the magnetic field and its derivative are mostly lower than the calculated. The induced voltages are in good agreement. Hence, calculations of the induced voltages based on IEC 62305-4 are a good method for lightning protection studies of buildings, where the reinforcement is used as a grid-like electromagnetic shield.
This study has been performed to design the combination of the new ClearPET TM (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal Positron Emission Tomography (PET) system, with a microComputed Tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material.
In: Net-distributed Co-operation : Xth International Conference on Computing in Civil and Building Engineering, Weimar, June 02 - 04, 2004 ; proceedings / [ed. by Karl Beuke ...] . - Weimar: Bauhaus-Univ. Weimar 2004. - 1. Aufl. . Seite 1-14 ISBN 3-86068-213-X International Conference on Computing in Civil and Building Engineering <10, 2004, Weimar> Summary In our project, we develop new tools for the conceptual design phase. During conceptual design, the coarse functionality and organization of a building is more important than a detailed worked out construction. We identify two roles, first the knowledge engineer who is responsible for knowledge definition and maintenance; second the architect who elaborates the conceptual de-sign. The tool for the knowledge engineer is based on graph technology, it is specified using PROGRES and the UPGRADE framework. The tools for the architect are integrated to the in-dustrial CAD tool ArchiCAD. Consistency between knowledge and conceptual design is en-sured by the constraint checker, another extension to ArchiCAD.
Info-Web-Generation
(2004)