Refine
Year of publication
- 1998 (242) (remove)
Document Type
- Article (165)
- Book (32)
- Conference Proceeding (23)
- Part of a Book (7)
- Patent (7)
- Report (5)
- Contribution to a Periodical (2)
- Doctoral Thesis (1)
Keywords
- Multimediamarkt (2)
- Bariumtitanat (1)
- Druckvergasung (1)
- Druckwirbelschichtfeuerung (1)
- Einspielanalyse (1)
- Filterkuchen (1)
- Finite-Elemente-Methode (1)
- Haustechnik (1)
- Heizung (1)
- Heterogene Katalyse (1)
- Keramischer Werkstoff (1)
- Klimatechnik (1)
- Kohlenmonoxidbelastung (1)
- Kraftwerkstechnik (1)
- Lasertechnik (1)
- Lüftung (1)
- Lüftungstechnik (1)
- Prozesssimulation (1)
- Rauchgasreinigung (1)
- Schadgas (1)
Institute
- Fachbereich Wirtschaftswissenschaften (40)
- Fachbereich Medizintechnik und Technomathematik (39)
- Fachbereich Chemie und Biotechnologie (31)
- Fachbereich Elektrotechnik und Informationstechnik (28)
- Fachbereich Energietechnik (28)
- Fachbereich Maschinenbau und Mechatronik (23)
- Solar-Institut Jülich (17)
- Fachbereich Luft- und Raumfahrttechnik (16)
- Fachbereich Bauingenieurwesen (13)
- Fachbereich Gestaltung (3)
- ECSM European Center for Sustainable Mobility (2)
- Fachbereich Architektur (2)
- Nowum-Energy (2)
- FH Aachen (1)
- Verwaltung (1)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (1)
The ATM technology for high speed serial transmission provides a new quality of communication by introducing novel features in a LAN environment, especially support of real time communication, of both LAN and WAN communication and of multimedia streams. In order to evaluate ATM for future DAQ systems and remote control systems as well as for a high speed picture archiving and communications system for medical images, Forschungszentrum Julich has build up a pilot system for the evaluation of ATM and standard low cost multimedia systems. It is a heterogeneous multivendor system containing a variety of switches and desktop solutions, employing different protocol options of ATM. The tests conducted in the pilot system revealed major difficulties regarding stability, interoperability and performance. The paper presents motivations, layout and results of the pilot system. Discussion of results concentrates on performance issues relevant for realistic applications, e.g., connection to a RAID system via NFS over ATM
Single-photon emission tomography (SPET) with the amino acid analogue l-3-[123I]iodo-α-methyl tyrosine (IMT) is helpful in the diagnosis and monitoring of cerebral gliomas. Radiolabelled amino acids seem to reflect tumour infiltration more specifically than conventional methods like magnetic resonance imaging and computed tomography. Automatic tumour delineation based on maximal tumour uptake may cause an overestimation of mean tumour uptake and an underestimation of tumour extension in tumours with circumscribed peaks. The aim of this study was to develop a program for tumour delineation and calculation of mean tumour uptake which takes into account the mean background activity and is thus optimised to the problem of tumour definition in IMT SPET. Using the frequency distribution of pixel intensities of the tomograms a program was developed which automatically detects a reference brain region and draws an isocontour region around the tumour taking into account mean brain radioactivity. Tumour area and tumour/brain ratios were calculated. A three-compartment phantom was simulated to test the program. The program was applied to IMT SPET studies of 20 patients with cerebral gliomas and was compared to the results of manual analysis by three different investigators. Activity ratios and chamber extension of the phantom were correctly calculated by the automatic analysis. A method based on image maxima alone failed to determine chamber extension correctly. Manual region of interest analysis in patient studies resulted in a mean inter-observer standard deviation of 8.7%±6.1% (range 2.7%–25.0%). The mean value of the results of the manual analysis showed a significant correlation to the results of the automatic analysis (r = 0.91, P<0.0001 for the uptake ratio; r = 0.87, P<0.0001 for the tumour area). We conclude that the algorithm proposed simplifies the calculation of uptake ratios and may be used for observer-independent evaluation of IMT SPET studies. Three-dimensional tumour recognition and transfer to co-registered morphological images based on this program may be useful for the planning of surgical and radiation treatment.
Smart pixel : photonic mixer device (PMD) ; new system concept of a 3D-imaging camera-on-a-chip
(1998)
Internet, Intranet, Extranet
(1998)
Regenerative Energiequellen
(1998)
Regenerative Energieträger
(1998)
Der Aluminium-Sekundärstoffstrom in Deutschland unter transporttechnischen Gesichtspunkten : Vortrag
(1998)
Entscheidungsunterstützung bei der Gestaltung der betrieblichen Energieversorgung und -nutzung
(1998)
Alles automatisch : komplexes qualitätsorientiertes Logistikmanagement durch Vollautomatisierung
(1998)
An BaTiO3 Keramik als Modellsubstanz und mit Nd:YAG- und Excimer-Lasern wurde die Mikrostrukturierung von Grünkörperpreßlingen, deren Schrumpfungsverhalten beim Sintern und die Mikrostrukturierung von gesinterten Keramiken untersucht. Für die bessere Vergleichbarkeit wurden alle keramischen Folien, Preßlinge und Sinterwerkstoffe im Rahmen des Projektes hergestellt. Die Nd:YAG Laserbearbeitung erfolgte mit einem Rasterverfahren, bei dem der fokussierte Strahl mit Hilfe eines Scanners und eines Umlenkspiegels entlang der Bearbeitungskontur geführt wurde. Bei der Excimer Laserbearbeitung wurden die Strukturen ohne Relativbewegung zwischen Strahlquelle und Bearbeitungsobjekt durch die Abbildung einer Maske erzeugt. Mit dem Nd:YAG Laser (Wellenlänge 1,06 µ m) war eine abtragende Bearbeitung nur bei den Grünkörpern, nicht aber bei den gesinterten Keramiken möglich. Mit dem Excimer Laser (Wellenlänge 248 nm) konnten dagegen sowohl Grünkörper als auch gesinterte Keramiken strukturiert werden. Wenn die Genauigkeitsanforderungen nicht unter ± 10 µm liegen, die Bearbeitungskonturen möglichst geradlinig sind und der Anteil der zu bearbeitenden Fläche klein ist, kann mit Nd:YAG-Lasern eine effiziente Mikrostukturierung von keramischen Grünkörpern durchgeführt werden. Strukturierte Grünkörper können reproduzierbar und unverzerrt zu keramischen Bauteilen gesintert werden. Mit Excimer-Lasern wird eine höhere Genauigkeit und Qualität bei der Bearbeitung von Grünkörpern und Keramiken erreicht. Die Bearbeitungseffizienz lässt sich durch eine hohe Pulswiederholfrequenz und durch die simultane Bearbeitung großer Flächen steigern. Das für Excimer-Laserstrahlung zweckmäßige Abbildungsverfahren hat besondere Vorteile, wenn ein flächiger Abtrag mit komplexen Strukturen verwirklicht werden soll, wobei Toleranzen und Reproduzierbarkeiten von besser als ± 5 µm realisiert werden konnten. Die Mikrostrukturierung mit Excimer-Lasern ist an Grünkörpern und an gebrannten Keramiken gleichermaßen möglich. Die Abtragsraten liegen bei Grünkörpern mit 0,2 µm pro Puls zwar um ca. 50% höher als bei Keramiken, es ist jedoch zweifelhaft, ob dieser Vorteil den größeren prozeßtechnischen Aufwand bei der Bearbeitung von Grünkörpern rechtfertigen kann.