Refine
Year of publication
- 2010 (331) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (68)
- Fachbereich Wirtschaftswissenschaften (41)
- Fachbereich Elektrotechnik und Informationstechnik (36)
- IfB - Institut für Bioengineering (36)
- Fachbereich Energietechnik (35)
- Fachbereich Chemie und Biotechnologie (34)
- Fachbereich Maschinenbau und Mechatronik (31)
- Fachbereich Luft- und Raumfahrttechnik (24)
- Fachbereich Bauingenieurwesen (23)
- INB - Institut für Nano- und Biotechnologien (23)
Has Fulltext
- no (331) (remove)
Document Type
- Article (177)
- Conference Proceeding (67)
- Book (37)
- Part of a Book (20)
- Conference: Meeting Abstract (12)
- Patent (7)
- Report (4)
- Other (2)
- Contribution to a Periodical (1)
- Doctoral Thesis (1)
Keywords
- Geschichte (2)
- avalanche (2)
- Adsorbentien (1)
- Cardiovascular MRI (1)
- Cardiovascular Magnetic Resonance (1)
- Commercial Vehicle (1)
- Common Rail Injection System (1)
- Diesel Engine (1)
- Enzymatischer Ligninabbau (1)
- European Transient Cycle (1)
In Valais, Switzerland, Scots pines (Pinus sylvestris L.) are declining, mainly following drought. To assess the impact of drought on tree growth and survival, an irrigation experiment was initiated in 2003 in a mature pine forest, approximately doubling the annual precipitation. Tree crown transparency (lack of foliage) and leaf area index (LAI) were annually assessed. Seven irrigated and six control trees were felled in 2006, and needles, stem discs and branches were taken for growth analysis. Irrigation in 2004 and 2005, both with below-average precipitation, increased needle size, area and mass, stem growth and, with a 1-year delay, shoot length. This led to a relative decrease in tree crown transparency (−14%) and to an increase in stand LAI (+20%). Irrigation increased needle length by 70%, shoot length by 100% and ring width by 120%, regardless of crown transparency. Crown transparency correlated positively with mean needle size, shoot length and ring width and negatively with specific leaf area. Trees with high crown transparency (low growth, short needles) experienced similar increases in needle mass and growth with irrigation than trees with low transparency (high growth, long needles), indicating that seemingly declining trees were able to ‘recover’ when water supply became sufficient. A simple drought index before and during the irrigation explained most of the variation found in the parameters for both irrigated and control trees.
Bilaterale stromale Hornhauttrübungen sind für den Augenarzt eine differenzialdiagnostische Herausforderung. Im folgenden Beitrag werden 2 Patieninnen (30 und 36 Jahre) mit unterschiedlich stark ausgeprägter stromaler diffuser Hornhauttrübung vorgestellt. Patientin 1 war kleinwüchsig (114 cm) und Patientin 2 normal groß (172 cm). Beide Patientinnen wiesen veränderte Gelenkstrukturen an Hand und Fußgelenken sowie diffuse stromale Hornhauttrübungen auf. Des Weiteren lagen eine Mitral- und Aorteninsuffizienz (Patientin 1) bzw. eine Aorteninsuffizienz (Patientin 2) vor. Die stromalen diffusen Hornhauttrübungen ließen im Zusammenhang mit den Gelenkveränderungen ein Scheie-Syndrom vermuten. Therapeutisch ist bei Patienten mit Visusminderung eine (lamelläre) Keratoplastik sinnvoll.
Differential modulation of valence and arousal in high-alexithymic and low-alexithymic individuals
(2010)
High-alexithymic individuals are characterized by an impaired ability to identify and communicate emotions whereas low-alexithymic individuals have a wide-ranging ability to deal with emotions. This study examined the hypothesis that valence and arousal modifications of emotional stimuli differentially modulate cortical regions in high-alexithymic and low-alexithymic individuals. To this end, 28 high-alexithymic and 25 low-alexithymic individuals were investigated with event-related fMRI using visual emotional stimuli. We found differential neural activations in the dorsal anterior cingulate, the insula and the amygdala. We suggest that these differences may account for the impaired ability of high-alexithymic individuals to appropriately handle emotional stimuli.
Im Herbst 2009 wurde das “Deutsche Gütesiegel Nachhaltiges Bauen” für die Gebäudetypen Industriebauten und Handelsbauten offiziell vorgestellt. Die Ökobilanz als wichtiger Baustein der Nachhaltigkeitsbewertung wird somit auch im Industrie- und Gewerbebau zukünftig stark an Bedeutung gewinnen.
Der vorliegende Beitrag beinhaltet einen Vergleich der Umweltleistung verschiedener Bauweisen des Industrie- und Gewerbebaus, die durch die Ökobilanzierung quantifizierbar wird, anhand von momentan verfügbaren Daten und Methoden. Es werden ausgewählte Ergebnisse sowie vorhandene Unsicherheiten und daraus resultierender Forschungsbedarf aufgezeigt.
Das verbraucherschützende Widerrufsrecht ist in die Jahre gekommen. Als Ergebnis der zunehmenden Rechtszersplitterung im europäischen Richtlinienrecht hat sich eine unüberschaubare Bandbreite an Ausgestaltungsformen in den mitgliedstaatlichen Rechtssystemen herausgebildet. Effektivitätseinbußen, Wettbewerbsverzerrungen und ein hohes Maß an Rechtsunsicherheit sind die Folgen. Zurückführen lässt sich die kostenintensive Fragmentierung des Verbrauchervertragsrechts auf die bisherige Regelungspolitik der Mindestharmonisierung, die es den Mitgliedstaaten erlaubt, von dem durch die Richtlinien gesetzten Mindeststandard durch „überschießende Umsetzung” abzuweichen. Der Unionsgesetzgeber versucht dem vermehrt durch einen Prozess der Vollharmonisierung zu begegnen: Neben Reformen der Richtlinie über Verbraucherkredite (VerbrKrRL) sowie der Timesharing-Richtlinie (TimesharingRL), liegt seit dem 8. Oktober 2008 nunmehr auch der Entwurf einer Rahmenrichtlinie über die Rechte der Verbraucher (VRRL-E) vor. Danach sollen die bisherigen Richtlinien über Haustürgeschäfte (HaustürgeschäfteRL), Fernabsatzverträge (FARL), missbräuchliche Klauseln sowie Verbrauchsgüterkäufe vereinigt werden. Für das verbraucherschützende Widerrufsrecht ist damit zum einen die Herausbildung einheitlicher Kernelemente verbunden, zum anderen tritt es in Konkurrenz zu umfassenden Informationspflichten, die ebenfalls den Schutz des Verbrauchers vor dem unüberlegten Abschluss riskanter bzw. nachteiliger Verträge zum Ziel haben.
Angesichts dieser Entwicklung stellt sich im Folgenden die Frage nach der Zukunft des unionsrechtlichen Widerrufsrechts. Von besonderer Bedeutung ist dabei die Klärung des Verhältnisses zu den verbraucherschützenden Informationspflichten. Dazu bedarf es zunächst der Herausarbeitung einheitlicher Kernelemente des Widerrufsrechts im vollharmonisierten Richtlinienrecht (II.) sowie einer Systematisierung der sekundärrechtlichen Informationspflichten im Anschluss eine kritische Gegenüberstellung der Vor- und Nachteile beider Schutzinstrumente erfolgen kann (IV.).
Die Konzernrechnungslegung
(2010)
Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants
(2010)
Positron emitters such as 11C, 13N and 18F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is 11CO2 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET™ system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements.
The CellDrum technology (The term 'CellDrum technology' includes a couple of slightly different technological setups for measuring lateral mechanical tension in various types of cell monolayers or 3D-tissue constructs) was designed to quantify the contraction rate and mechanical tension of self-exciting cardiac myocytes. Cells were grown either within flexible, circular collagen gels or as monolayer on top of respective 1-mum thin silicone membranes. Membrane and cells were bulged outwards by air pressure. This biaxial strain distribution is rather similar the beating, blood-filled heart. The setup allowed presetting the mechanical residual stress level externally by adjusting the centre deflection, thus, mimicking hypertension in vitro. Tension was measured as oscillating differential pressure change between chamber and environment. A 0.5-mm thick collagen-cardiac myocyte tissue construct induced after 2 days of culturing (initial cell density 2 x 10(4) cells/ml), a mechanical tension of 1.62 +/- 0.17 microN/mm(2). Mechanical load is an important growth regulator in the developing heart, and the orientation and alignment of cardiomyocytes is stress sensitive. Therefore, it was necessary to develop the CellDrum technology with its biaxial stress-strain distribution and defined mechanical boundary conditions. Cells were exposed to strain in two directions, radially and circumferentially, which is similar to biaxial loading in real heart tissues. Thus, from a biomechanical point of view, the system is preferable to previous setups based on uniaxial stretching.
Objective: As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to interference from electromagnetic fields (EMF) and to magneto-hydrodynamic (MHD) effects increases and with it the motivation for a CMR triggering alternative. This study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects (n=14). Methods: Quantitative analysis of 2D CINE steady-state free precession (SSFP) images was conducted to compare ACT’s performance with vector ECG (VCG). Endocardial border sharpness (EBS) was examined paralleled by quantitative LV function assessment. Results: Unlike VCG, ACT provided signal traces free of interference from EMF or MHD effects. In the case of correct Rwave recognition, VCG-triggered 2D CINE SSFP was immune to cardiac motion effects—even at 3.0 T. However, VCG-triggered 2D SSFP CINE imaging was prone to cardiac motion and EBS degradation if R-wave misregistration occurred. ACT-triggered acquisitions yielded LV parameters (end-diastolic volume (EDV), endsystolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular mass (LVM)) comparable with those derived fromVCG-triggered acquisitions (1.5 T: ESVVCG=(56± 17) ml, EDVVCG=(151±32)ml, LVMVCG=(97±27) g, SVVCG=(94± 19)ml, EFVCG=(63±5)% cf. ESVACT= (56±18) ml, EDVACT=(147±36) ml, LVMACT=(102±29) g, SVACT=(91± 22) ml, EFACT=(62±6)%; 3.0 T: ESVVCG=(55±21) ml, EDVVCG=(151±32) ml, LVMVCG=(101±27) g, SVVCG=(96±15) ml, EFVCG=(65±7)% cf. ESVACT=(54±20) ml, EDVACT=(146±35) ml, LVMACT= (101±30) g, SVACT=(92±17) ml, EFACT=(64±6)%). Conclusions: ACT’s intrinsic insensitivity to interference from electromagnetic fields renders
As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to distortions and mistriggering increases and with it the motivation for a cardiac triggering alternative. Hence, this study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects at 1.5T and 3.0T.
Comparison of Intravenous Immunoglobulins for Naturally Occurring Autoantibodies against Amyloid-β
(2010)
Molke fällt im Rahmen der Käseherstellung allein in Deutschland in Mengen von über 11 Mio. Tonnen jährlich an. Dieses Nebenprodukt wurde trotz seines Reichtums an Milchzucker und Proteinen lange Zeit kaum industriell weiterverarbeitet und stellte ein bedeutendes Problem bei der Abwasserreinigung dar. Derzeit kommen meist kosten- und reinigungsintensive Membranfiltrationsverfahren bei der Auftrennung von Molke in ihre Hauptkomponenten Lactose und Molkenprotein zum Einsatz. Die Produkte finden vorwiegend in der Nahrungsmittelindustrie Anwendung als Süßungsmittel, Proteinzusatz oder Texturbildner. Die Mehrheit des Proteins wird dabei als Konzentrat bzw. Proteinpulver verarbeitet. Wegen der antibakteriellen, antiviralen und weiteren wertvollen physiologischen Eigenschaften der Molkeproteine stellt eine weitere Aufreinigung der einzelnen Molkeproteine für die pharmazeutische Industrie einen naheliegenden zusätzlichen Wertschöpfungsschritt dar. In Kooperation mit der Süd Chemie AG wurde damit begonnen, ein Verfahren zu entwickeln, das kostengünstige mineralische Adsorbentien verwendet. Bisher konnte die Abtrennung von Lactose von den Molkenproteinen aus verdünntem Molkekonzentrat in einem Verfahrensschritt ohne Vorbehandlung des Rohstoffs erfolgreich realisiert werden. Aktuelle Arbeiten beschäftigen sich mit der Verbesserung der Proteinbindekapazitätund chromatographischen Proteinauftrennung sowie dem Upscaling zum direkten Einsatz von Molkekonzentrat ohne Vorverdünnung.
The objectives of the present work are to characterize the Gas Metal Arc Welding process of DP 600 sheet steel and to summarize the modelling techniques. The time-temperature evolution during the welding cycle was measured experimentally and modelled with the softwaretool SimWeld. To model the phase transformations during the welding cycle dilatometer tests were done to quantify the parameters for phase field modelling by MICRESS®. The important input parameters are interface mobility, nucleation density, etc. A contribution was made to include austenite to bainite transformation in MICRESS®. This is useful to predict the microstructure in the fast cooling segments. The phase transformation model is capable to predict the microstructure along the heating and cooling cycles of welding. Tensile tests have shown the evidence of failure at the heat affected zone, which has the ferrite-tempered martensite microstructure.
Objectives
Interest in cardiovascular magnetic resonance (CMR) at 7 T is motivated by the expected increase in spatial and temporal resolution, but the method is technically challenging. We examined the feasibility of cardiac chamber quantification at 7 T.
Methods
A stack of short axes covering the left ventricle was obtained in nine healthy male volunteers. At 1.5 T, steady-state free precession (SSFP) and fast gradient echo (FGRE) cine imaging with 7 mm slice thickness (STH) were used. At 7 T, FGRE with 7 mm and 4 mm STH were applied. End-diastolic volume, end-systolic volume, ejection fraction and mass were calculated.
Results
All 7 T examinations provided excellent blood/myocardium contrast for all slice directions. No significant difference was found regarding ejection fraction and cardiac volumes between SSFP at 1.5 T and FGRE at 7 T, while volumes obtained from FGRE at 1.5 T were underestimated. Cardiac mass derived from FGRE at 1.5 and 7 T was larger than obtained from SSFP at 1.5 T. Agreement of volumes and mass between SSFP at 1.5 T and FGRE improved for FGRE at 7 T when combined with an STH reduction to 4 mm.
Conclusions
This pilot study demonstrates that cardiac chamber quantification at 7 T using FGRE is feasible and agrees closely with SSFP at 1.5 T.
C-terminal truncation of a metagenome-derived detergent protease for effective expression in E. coli
(2010)
Recently, a new alkaline protease named HP70 showing highest homology to extracellular serine proteases of Stenotrophomonas maltophilia and Xanthomonas campestris was found in the course of a metagenome screening for detergent proteases (Niehaus et al., submitted for publication). Attempts to efficiently express the enzyme in common expression hosts had failed. This study reports on the realization of overexpression in Escherichia coli after structural modification of HP70. Modelling of HP70 resulted in a two-domain structure, comprising the catalytic domain and a C-terminal domain which includes about 100 amino acids. On the basis of the modelled structure the enzyme was truncated by deletion of most of the C-terminal domain yielding HP70-C477.
This structural modification allowed effective expression of active enzyme using E. coli BL21-Gold as the host. Specific activity of HP70-C477 determined with suc-l-Ala-l-Ala-l-Pro-l-Phe-p-nitroanilide as the substrate was 30 ± 5 U/mg compared to 8 ± 1 U/mg of the native enzyme. HP70-C477 was most active at 40 °C and pH 7–11; these conditions are prerequisite for a potential application as detergent enzyme. Determination of kinetic parameters at 40 °C and pH = 9.5 resulted in KM = 0.23 ± 0.01 mM and kcat = 167.5 ± 3.6 s⁻¹. MS-analysis of peptide fragments obtained from incubation of HP70 and HP70-C477 with insulin B indicated that the C-terminal domain influences the cleavage preferences of the enzyme. Washing experiments confirmed the high potential of HP70-C477 as detergent protease.
Die SPAC-SE ist börsenfähig und damit eine für eine SPAC grundsätzlich geeignete Rechtsform. Die Tatsache, dass es sich hierbei (zunächst) um eine leere, arbeitnehmerlose Hülle handelt, ändert hieran nichts. Die Gründung einer solchen Vorrats-SE ist trotz fehlender Arbeitnehmerbeteiligung unter teleologischer Reduktion von Art. 12 II SE-VO zulässig. Im Gegenzug muss die Arbeitnehmerbeteiligung gemaß § 18 III SEBG analog nachgeholt werden, wenn das später erworbene Zielunternehmen auf die SPAC-SE verschmolzen werden soll. Aus gesellschaftsrechtlicher Sicht ist zu beachten, dass die SPAC-SE mit Sitz in Deutschland, welche auch den deutschen, aktienrechtlichen Bestimmungen unterliegt, nur bedingt für eine SPAC geeignet erscheint. Das deutsche Aktienrecht enthält strenge Regelungen, die der für eine SPAC-SE erforderlichen Flexibilität entgegenstehen können. Dies gilt insbesondere für das Erfordernis der Zustimmung der Hauptversammlung zur Akquisition des Zielunternehmens, die Rückzahlung des Treuhandvermögens an Aktionäre, die der Akquisition nicht zugestimmt haben und die Liquidation der SPAC-SE im Falle des Scheiterns des Erwerbs des Zielobjektes.
In den letzten drei bis vier Jahren unterlag der Bereich der Bilanzierung und Offenlegung von unsicheren Steuerpositionen im IFRS- und US-GAAP-Abschluss einem stetigen Wandel. Sowohl nach US-GAAP als auch nach IFRS nehmen die Anforderungen an die Bilanzierung und Offenlegung beständig zu. Schon allein dies zeigt die Bedeutung, die dem Themenbereich der Steuerrisiken beigemessen wird. Aber nicht nur im Rahmen der Berichterstattung im Jahresabschluss stehen Steuerrisiken oben auf der Agenda, auch der amerikanische Internal Revenue Service (IRS) verfolgt das Thema sehr konsequent und plant, bestimmte Unternehmen zu Angaben von Steuerrisiken im Rahmen der Steuererklärungen zu verpflichten.
Der Aufsatz befasst sich mit den neueren Entwicklungen im Bereich der Bilanzierung und Offenlegung von unsicheren Steuerpositionen in der Rechnungslegung nach IFRS, US-GAAP und HGB und der Offenlegung von Steuerrisiken im Rahmen der Steuererklärung.
Betriebsratswahlen 2010
(2010)
Die nächsten regelmäßigen Wahlen zum Betriebsrat (BR) stehen vor der Tür. Sie finden in der Zeit vom 1.3.2010 bis 31.5.2010 statt. Die Wahlen sind zwar vornehmlich Sache der Arbeitnehmer, allerdings sollten auch die Arbeitgeber darauf achten, dass die Wahlen korrekt ablaufen, schließlich haben die Arbeitgeber die Kosten der Wahlen zu tragen. Kommt es hierbei zu Fehlern, die schlimmstenfalls eine Wiederholung der Wahlen erfordern, hat auch für die hierdurch zusätzlich entstehenden Kosten der Arbeitgeber aufzukommen. Zudem bietet die aktive und unterstützende Begleitung der Wahlen für die Arbeitgeber die Chance, die Grundlagen für eine konstruktive Zusammenarbeit mit dem künftigen Betriebsrat zu legen. Der vorliegende Beitrag erläutert die wesentlichen Abläufe des Wahlverfahrens sowie die hierbei zwingend zu beachtenden Fristen.
Beobachtungskommunikation
(2010)