Refine
Year of publication
- 2006 (330) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (75)
- Fachbereich Bauingenieurwesen (51)
- Fachbereich Wirtschaftswissenschaften (45)
- Fachbereich Luft- und Raumfahrttechnik (32)
- Fachbereich Energietechnik (29)
- Fachbereich Maschinenbau und Mechatronik (29)
- Fachbereich Elektrotechnik und Informationstechnik (27)
- IfB - Institut für Bioengineering (24)
- INB - Institut für Nano- und Biotechnologien (22)
- Fachbereich Chemie und Biotechnologie (17)
Language
- German (166)
- English (160)
- Russian (2)
- Portuguese (1)
- Spanish (1)
Document Type
- Article (179)
- Conference Proceeding (95)
- Book (29)
- Patent (6)
- Part of a Book (5)
- Diploma Thesis (3)
- Lecture (3)
- Other (3)
- Course Material (2)
- Report (2)
Keywords
- Biosensor (23)
- CAD (3)
- Technische Mechanik (3)
- Bauingenieurwesen (2)
- Bauplanung (2)
- Führung (2)
- Leadership (2)
- Motivation (2)
- Rapid Prototyping (2)
- Rapid prototyping (2)
Para Reiss, a avaliação de cada um dos 16 motivos vitais é a chave para não só entender o comportamento humano, como também para poder prevê-lo. Tal previsão é também a meta de cada ciência. Quando se quer saber a reação das pessoas, precisa-se primeiro descobrir, o que as pessoas realmente querem – e, então prever, que elas satisfarão esses desejos e necessidades em suas ações. As chances, que o Perfil Reiss oferece, resultam entre outras também, que aqui é possível pela primeira vez uma individualização total. Cerca de 6 bilhões de perfis individuais podem ser apresentados com o Perfil Reiss. Na combinação correta da formação e utilização da tipologia de um lado e da individualidade da conclusão de outro lado, está a força positiva desse instrumento.
We report on the synthesis and CO gas-sensing properties of mesoporous tin(IV) oxides (SnO2). For the synthesis cetyltrimethylammonium bromide (CTABr) was used as a structure-directing agent; the resulting SnO2 powders were applied as films to commercially available sensor substrates by drop coating. Nitrogen physisorption shows specific surface areas up to 160 m2·g-1 and mean pore diameters of about 4 nm, as verified by TEM. The film conductance was measured in dependence on the CO concentration in humid synthetic air at a constant temperature of 300 °C. The sensors show a high sensitivity at low CO concentrations and turn out to be largely insensitive towards changes in the relative humidity. We compare the materials with commercially available SnO2-based sensors.
Praktische Untersuchungen zum zeitlichen Übertragungs- und Bündelfehlerverhalten der IEEE 802.15.4
(2006)
Analysis of error and time behavior of the IEEE 802.15.4 PHY-layer in an industrial environment
(2006)
Various planar technologies are employed for developing solid-state sensors having low cost, small size and high reproducibility; thin- and thick-film technologies are most suitable for such productions. Screen-printing is especially suitable due to its simplicity, low-cost, high reproducibility and efficiency in large-scale production. This technology enables the deposition of a thick layer and allows precise pattern control. Moreover, this is a highly economic technology, saving large amounts of the used inks. In the course of repetitions of the film-deposition procedure there is no waste of material due to additivity of this thick-film technology. Finally, the thick films can be easily and quickly deposited on inexpensive substrates. In this contribution, thick-film ion-selective electrodes based on ionophores as well as crystalline ion-selective materials dedicated for potentiometric measurements are demonstrated. Analytical parameters of these sensors are comparable with those reported for conventional potentiometric electrodes. All mentioned thick-film strip electrodes have been totally fabricated in only one, fully automated thickfilm technology, without any additional manual, chemical or electrochemical steps. In all cases simple, inexpensive, commercially available materials, i.e. flexible, plastic substrates and easily cured polymer-based pastes were used.
The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in Jülich (ClearPET Neuro) is equipped with 10240 crystals on 80 PMTs. The paper will present an overview of the data acquisition system.
The small animal PET scanners developed by the Crystal Clear Collaboration (ClearPETtrade) detect coincidences by analyzing timemarks which are attached to each event. The scanners are able to save complete single list mode data which allows analysis and modification of the timemarks after data acquisition. The timemarks are obtained from the digitally sampled detector pulses by calculating the baseline crossing of the rising edge of the pulse which is approximated as a straight line. But the limited sampling frequency causes a systematic error in the determination of the timemark. This error depends on the phase of the sampling clock at the time of the event. A statistical method that corrects these errors will be presented
Limit loads of circumferentially flawed pipes and cylindrical vessels under internal pressure
(2006)
In: Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in Jülich, 21-24 November 1994. - Vienna , 1996. - Seite: 43 - 55 IAEA-TECDOC-920 Abstract: It is shown that the difficulty for probabilistic fracture mechanics (PFM) is the general problem of the high reliability of a small population. There is no way around the problem as yet. Therefore what PFM can contribute to the reliability of steel pressure boundaries is demonstrated with the example of a typical reactor pressure vessel and critically discussed. Although no method is distinguishable that could give exact failure probabilities, PFM has several additional chances. Upper limits for failure probability may be obtained together with trends for design and operating conditions. Further, PFM can identify the most sensitive parameters, improved control of which would increase reliability. Thus PFM should play a vital role in the analysis of steel pressure boundaries despite all shortcomings.
Study of swift heavy ion modified conduction polymer composites for application as gas sensor
(2006)
A polyaniline-based conducting composite was prepared by oxidative polymerisation of aniline in a polyvinylchloride (PVC) matrix. The coherent free standing thin films of the composite were prepared by a solution casting method. The polyvinyl chloride-polyaniline composites exposed to 120 MeV ions of silicon with total ion fluence ranging from 1011 to 1013 ions/cm2, were observed to be more sensitive towards ammonia gas than the unirradiated composite. The response time of the irradiated composites was observed to be comparably shorter. We report for the first time the application of swift heavy ion modified insulating polymer conducting polymer (IPCP) composites for sensing of ammonia gas.
Micromachined thermal heater platforms offer low electrical power consumption and high modulation speed, i.e. properties which are advantageous for realizing nondispersive infrared (NDIR) gas- and liquid monitoring systems. In this paper, we report on investigations on silicon-on-insulator (SOI) based infrared (IR) emitter devices heated by employing different kinds of metallic and semiconductor heater materials. Our results clearly reveal the superior high-temperature performance of semiconductor over metallic heater materials. Long-term stable emitter operation in the vicinity of 1300 K could be attained using heavily antimony-doped tin dioxide (SnO2:Sb) heater elements.
Abschlussarbeiten FAQ / FGA
(2006)