Refine
Year of publication
- 2011 (323) (remove)
Document Type
- Article (180)
- Conference Proceeding (76)
- Book (24)
- Part of a Book (21)
- Report (7)
- Patent (5)
- Other (3)
- Doctoral Thesis (2)
- Part of Periodical (2)
- Bachelor Thesis (1)
- Contribution to a Periodical (1)
- Diploma Thesis (1)
Keywords
- Aachen / Fachhochschule Aachen (3)
- Aachen University of Applied Sciences (3)
- Aktionskunst (3)
- FH Aachen (2)
- Illustration (2)
- Interaktive Kunst (2)
- Kommunikationsguerrilla (2)
- Pflanzenphysiologie (2)
- Pflanzenscanner (2)
- Stadtgestaltung (2)
- Streetart (2)
- plant scanner (2)
- Öffentlicher Raum (2)
- Aachen / Fachhochschule Aachen / Fachbereich Bauingenieurwesen (1)
- Absolvententreffen (1)
- Alfha.net (1)
- Alumni (1)
- Anastomose (1)
- Anastomosis (1)
- Angewandte Forschung (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (82)
- Fachbereich Elektrotechnik und Informationstechnik (38)
- INB - Institut für Nano- und Biotechnologien (37)
- Fachbereich Wirtschaftswissenschaften (34)
- IfB - Institut für Bioengineering (34)
- Fachbereich Chemie und Biotechnologie (28)
- Fachbereich Energietechnik (26)
- Fachbereich Bauingenieurwesen (24)
- Fachbereich Maschinenbau und Mechatronik (24)
- Fachbereich Luft- und Raumfahrttechnik (23)
- Solar-Institut Jülich (19)
- Fachbereich Gestaltung (11)
- Fachbereich Architektur (9)
- FH Aachen (5)
- Nowum-Energy (5)
- ECSM European Center for Sustainable Mobility (2)
- Freshman Institute (1)
- Sonstiges (1)
A light-addressable potentiometric sensor (LAPS) can measure the concentration of one or several analytes at the sensor surface simultaneously in a spatially resolved manner. A modulated light pointer stimulates the semiconductor structure at the area of interest and a responding photocurrent can be read out. By simultaneous stimulation of several areas with light pointers of different modulation frequencies, the read out can be performed at the same time. With the new proposed controller electronic based on a field-programmable gate array (FPGA), it is possible to control the modulation frequencies, phase shifts, and light brightness of multiple light pointers independently and simultaneously. Thus, it is possible to investigate the frequency response of the sensor, and to examine the analyte concentration by the determination of the surface potential with the help of current/voltage curves and phase/voltage curves. Additionally, the ability to individually change the light intensities of each light pointer is used to perform signal correction.