Refine
Year of publication
- 2014 (166) (remove)
Document Type
- Article (93)
- Conference Proceeding (51)
- Part of a Book (14)
- Book (3)
- Doctoral Thesis (1)
- Master's Thesis (1)
- Patent (1)
- Poster (1)
- Report (1)
Language
- English (166) (remove)
Keywords
- Antarctic Glaciology (1)
- Bloom Taxonomy (1)
- Bone sawing (1)
- COMSOL Multiphysics (1)
- Calorimetric gas sensor (1)
- Cryptographic protocols (1)
- DNA hybridization (1)
- Extraterrestrial Glaciology (1)
- Field-effect sensor (1)
- Glaciological instruments and methods (1)
- Hydrogen peroxide (1)
- LAPS (1)
- Light-addressable Potentiometric Sensor (1)
- LiveLink for MATLAB (1)
- Malicious model (1)
- Multi-sensor system (1)
- Optimization module (1)
- Privacy-enhancing technologies (1)
- Secure multi-party computation (1)
- Subclacial exploration (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (58)
- INB - Institut für Nano- und Biotechnologien (34)
- Fachbereich Chemie und Biotechnologie (24)
- Fachbereich Elektrotechnik und Informationstechnik (24)
- IfB - Institut für Bioengineering (24)
- Fachbereich Energietechnik (22)
- Fachbereich Luft- und Raumfahrttechnik (13)
- Fachbereich Wirtschaftswissenschaften (6)
- Fachbereich Bauingenieurwesen (4)
- Solar-Institut Jülich (4)
- Fachbereich Maschinenbau und Mechatronik (3)
- Sonstiges (3)
- ECSM European Center for Sustainable Mobility (1)
- Institut fuer Angewandte Polymerchemie (1)
This article describes the fabrication, characterization and application of an epidermal temporary-transfer tattoo-based potentiometric sensor, coupled with a miniaturized wearable wireless transceiver, for real-time monitoring of sodium in the human perspiration. Sodium excreted during perspiration is an excellent marker for electrolyte imbalance and provides valuable information regarding an individual's physical and mental wellbeing. The realization of the new skin-worn non-invasive tattoo-like sensing device has been realized by amalgamating several state-of-the-art thick film, laser printing, solid-state potentiometry, fluidics and wireless technologies. The resulting tattoo-based potentiometric sodium sensor displays a rapid near-Nernstian response with negligible carryover effects, and good resiliency against various mechanical deformations experienced by the human epidermis. On-body testing of the tattoo sensor coupled to a wireless transceiver during exercise activity demonstrated its ability to continuously monitor sweat sodium dynamics. The real-time sweat sodium concentration was transmitted wirelessly via a body-worn transceiver from the sodium tattoo sensor to a notebook while the subjects perspired on a stationary cycle. The favorable analytical performance along with the wearable nature of the wireless transceiver makes the new epidermal potentiometric sensing system attractive for continuous monitoring the sodium dynamics in human perspiration during diverse activities relevant to the healthcare, fitness, military, healthcare and skin-care domains.
Organic anion transporting polypeptide (Oatp) 1a/1b knockout and OATP1B1 and -1B3 humanized mouse models are promising tools for studying the roles of these transporters in drug disposition. Detailed characterization of these models will help to better understand their utility for predicting clinical outcomes. To advance this approach, we carried out a comprehensive analysis of these mouse lines by evaluating the compensatory changes in mRNA expression, quantifying the amounts of OATP1B1 and -1B3 protein by liquid chromatography–tandem mass spectrometry, and studying the active uptake in isolated hepatocytes and the pharmacokinetics of some prototypical substrates including statins. Major outcomes from these studies were 1) mostly moderate compensatory changes in only a few genes involved in drug metabolism and disposition, 2) a robust hepatic expression of OATP1B1 and -1B3 proteins in the respective humanized mouse models, and 3) functional activities of the human transporters in hepatocytes isolated from the humanized models with several substrates tested in vitro and with pravastatin in vivo. However, the expression of OATP1B1 and -1B3 in the humanized models did not significantly alter liver or plasma concentrations of rosuvastatin and pitavastatin compared with Oatp1a/1b knockout controls under the conditions used in our studies. Hence, although the humanized OATP1B1 and -1B3 mice showed in vitro and/or in vivo functional activity with some statins, further characterization of these models is required to define their potential use and limitations in the prediction of drug disposition and drug-drug interactions in humans.
Network theory provides novel concepts that promise an improved characterization of interacting dynamical systems. Within this framework, evolving networks can be considered as being composed of nodes, representing systems, and of time-varying edges, representing interactions between these systems. This approach is highly attractive to further our understanding of the physiological and pathophysiological dynamics in human brain networks. Indeed, there is growing evidence that the epileptic process can be regarded as a large-scale network phenomenon. We here review methodologies for inferring networks from empirical time series and for a characterization of these evolving networks. We summarize recent findings derived from studies that investigate human epileptic brain networks evolving on timescales ranging from few seconds to weeks. We point to possible pitfalls and open issues, and discuss future perspectives.
The Dry Low NOx (DLN) Micromix combustion principle with increased energy density is adapted for the industrial gas turbine APU GTCP 36-300 using hydrogen and hydrogen-rich syngas with a composition of 90%-Vol. hydrogen (H₂) and 10%-Vol. carbon-monoxide (CO). Experimental and numerical studies of several combustor geometries for hydrogen and syngas show the successful advance of the DLN Micromix combustion from pure hydrogen to hydrogen-rich syngas. The impact of the different fuel properties on the combustion principle and aerodynamic flame stabilization design laws, flow field, flame structure and emission characteristics is investigated by numerical analysis using a hybrid Eddy Break Up combustion model and validated against experimental results.
Planning the layout and operation of a technical system is a common task
for an engineer. Typically, the workflow is divided into consecutive stages: First,
the engineer designs the layout of the system, with the help of his experience or of
heuristic methods. Secondly, he finds a control strategy which is often optimized
by simulation. This usually results in a good operating of an unquestioned sys-
tem topology. In contrast, we apply Operations Research (OR) methods to find a
cost-optimal solution for both stages simultaneously via mixed integer program-
ming (MILP). Technical Operations Research (TOR) allows one to find a provable
global optimal solution within the model formulation. However, the modeling error
due to the abstraction of physical reality remains unknown. We address this ubiq-
uitous problem of OR methods by comparing our computational results with mea-
surements in a test rig. For a practical test case we compute a topology and control
strategy via MILP and verify that the objectives are met up to a deviation of 8.7%.
Purpose
To demonstrate that high quality T₂-weighted (T2w) turbo spin-echo (TSE) imaging of the complete prostate can be achieved routinely and within safety limits at 7 T, using an external transceive body array coil only.
Methods
Nine healthy volunteers and 12 prostate cancer patients were scanned on a 7 T whole-body system. Preparation consisted of B₀ and radiofrequency shimming and localized flip angle calibration. T₁ and T₂ relaxation times were measured and used to define the T2w-TSE protocol. T2w imaging was performed using a TSE sequence (pulse repetition time/echo time 3000–3640/71 ms) with prolonged excitation and refocusing pulses to reduce specific absorption rate.
Results
High quality T2w TSE imaging was performed in less than 2 min in all subjects. Tumors of patients with gold-standard tumor localization (MR-guided biopsy or prostatectomy) were well visualized on 7 T imaging (n = 3). The number of consecutive slices achievable within a 10-g averaged specific absorption rate limit of 10 W/kg was ≥28 in all subjects, sufficient for full prostate coverage with 3-mm slices in at least one direction.
Conclusion
High quality T2w TSE prostate imaging can be performed routinely and within specific absorption rate limits at 7 T with an external transceive body array.