Article
Refine
Year of publication
- 2024 (55)
- 2023 (80)
- 2022 (93)
- 2021 (109)
- 2020 (135)
- 2019 (123)
- 2018 (127)
- 2017 (109)
- 2016 (118)
- 2015 (126)
- 2014 (142)
- 2013 (139)
- 2012 (130)
- 2011 (182)
- 2010 (140)
- 2009 (199)
- 2008 (180)
- 2007 (176)
- 2006 (179)
- 2005 (188)
- 2004 (214)
- 2003 (154)
- 2002 (167)
- 2001 (157)
- 2000 (173)
- 1999 (153)
- 1998 (165)
- 1997 (154)
- 1996 (140)
- 1995 (147)
- 1994 (136)
- 1993 (108)
- 1992 (102)
- 1991 (74)
- 1990 (82)
- 1989 (79)
- 1988 (80)
- 1987 (77)
- 1986 (65)
- 1985 (59)
- 1984 (56)
- 1983 (47)
- 1982 (38)
- 1981 (39)
- 1980 (50)
- 1979 (43)
- 1978 (41)
- 1977 (22)
- 1976 (25)
- 1975 (18)
- 1974 (13)
- 1973 (6)
- 1972 (15)
- 1971 (7)
- 1970 (2)
- 1968 (2)
- 1967 (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (1585)
- Fachbereich Wirtschaftswissenschaften (704)
- Fachbereich Elektrotechnik und Informationstechnik (631)
- Fachbereich Chemie und Biotechnologie (605)
- Fachbereich Energietechnik (605)
- INB - Institut für Nano- und Biotechnologien (538)
- Fachbereich Maschinenbau und Mechatronik (497)
- IfB - Institut für Bioengineering (444)
- Fachbereich Luft- und Raumfahrttechnik (376)
- Fachbereich Bauingenieurwesen (334)
Language
Document Type
- Article (5641) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- Multimediamarkt (6)
- Rapid prototyping (5)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- Rapid Prototyping (4)
- SLM (4)
The potential of electronic markets in enabling innovative product bundles through flexible and sustainable partnerships is not yet fully exploited in the telecommunication industry. One reason is that bundling requires seamless de-assembling and re-assembling of business processes, whilst processes in telecommunication companies are often product-dependent and hard to virtualize. We propose a framework for the planning of the virtualization of processes, intended to assist the decision maker in prioritizing the processes to be virtualized: (a) we transfer the virtualization pre-requisites stated by the Process Virtualization Theory in the context of customer-oriented processes in the telecommunication industry and assess their importance in this context, (b) we derive IT-oriented requirements for the removal of virtualization barriers and highlight their demand on changes at different levels of the organization. We present a first evaluation of our approach in a case study and report on lessons learned and further steps to be performed.
As the potential of a next generation network (NGN) is recognised, telecommunication companies consider switching to it. Although the implementation of an NGN seems to be merely a modification of the network infrastructure, it may trigger or require changes in the whole company, because it builds upon the separation between service and transport, a flexible bundling of services to products and the streamlining of the IT infrastructure. We propose a holistic framework, structured into the layers ‘strategy’, ‘processes’ and ‘information systems’ and incorporate into each layer all concepts necessary for the implementation of an NGN, as well as the alignment of these concepts. As a first proof-of-concept for our framework we have performed a case study on the introduction of NGN in a large telecommunication company; we show that our framework captures all topics that are affected by an NGN implementation.
Der Telekommunikationsmarkt erfährt substanzielle Veränderungen. Neue Geschäftsmodelle, innovative Dienstleistungen und Technologien erfordern Reengineering, Transformation und Prozessstandardisierung. Mit der Enhanced Telecom Operation Map (eTOM) bietet das TM Forum ein international anerkanntes de facto Referenz-Prozess-Framework basierend auf spezifischen Anforderungen und Ausprägungen der Telekommunikationsindustrie an. Allerdings enthält dieses Referenz-Framework nur eine hierarchische Sammlung von Prozessen auf unterschiedlichen Abstraktionsebenen. Eine Kontrollsicht verstanden als sequenzielle Anordnung von Aktivitäten und daraus resultierend ein realer Prozessablauf fehlt ebenso wie eine Ende-zu-Ende-Sicht auf den Kunden. In diesem Artikel erweitern wir das eTOM-Referenzmodell durch Referenzprozessabläufe, in welchen wir das Wissen über Prozesse in Telekommunikationsunternehmen abstrahieren und generalisieren. Durch die Referenzprozessabläufe werden Unternehmen bei dem strukturierten und transparenten (Re-)Design ihrer Prozesse unterstützt. Wir demonstrieren die Anwendbarkeit und Nützlichkeit unserer Referenzprozessabläufe in zwei Fallstudien und evaluieren diese anhand von Kriterien für die Bewertung von Referenzmodellen. Die Referenzprozessabläufe wurden vom TM Forum in den Standard aufgenommen und als Teil von eTOM Version 9 veröffentlicht. Darüber hinaus diskutieren wir die Komponenten unseres Ansatzes, die auch außerhalb der Telekommunikationsindustrie angewandt werden können.
Das anhaltende Wachstum wissenschaftlicher Veröffentlichungen wirft die Fragestellung auf, wie Literaturana-lysen im Rahmen von Forschungsprozessen digitalisiert und somit produktiver realisiert werden können. Insbesondere in informationstechnischen Fachgebieten ist die Forschungspraxis durch ein rasant wachsendes Publikationsaufkommen gekennzeichnet. Infolgedessen bietet sich der Einsatz von Methoden der Textanalyse (Text Analytics) an, die Textdaten automatisch vorbereiten und verarbeiten können. Erkenntnisse entstehen dabei aus Analysen von Wortarten und Subgruppen, Korrelations- sowie Zeitreihenanalysen. Dieser Beitrag stellt die Konzeption und Realisierung eines Prototypen vor, mit dem Anwender bibliographische Daten aus der etablierten Literaturdatenbank EBSCO Discovery Service mithilfe textanalytischer Methoden erschließen können. Der Prototyp basiert auf dem Analysesystem IBM Watson Explorer, das Hochschulen lizenzkostenfrei zur Verfügung steht. Potenzielle Adressaten des Prototypen sind Forschungseinrichtungen, Beratungsunternehmen sowie Entscheidungsträger in Politik und Unternehmenspraxis.
Im Rahmen der Digitalisierung ist die zunehmende Automatisierung von bisher manuellen Prozessschritten ein Aspekt, der massive Auswirkungen auf die zukünftige Arbeitswelt haben wird. In diesem Kontext werden an den Einsatz von Softwarerobotern zur Prozessautomatisierung hohe Erwartungen geknüpft. Bei den Implementierungsansätzen wird die Diskussion aktuell insbesondere durch Robotic Process Automation (RPA) und Chatbots geprägt. Beide Ansätze verfolgen das gemeinsame Ziel einer 1:1-Automatisierung von menschlichen Handlungen und dadurch ein direktes Ersetzen von Mitarbeitern durch Maschinen. Bei RPA werden Prozesse durch Softwareroboter erlernt und automatisiert ausgeführt. Dabei emulieren RPA-Roboter die Eingaben auf der bestehenden Präsentationsschicht, so dass keine Änderungen an vorhandenen Anwendungssystemen notwendig sind. Am Markt werden bereits unterschiedliche RPA-Lösungen als Softwareprodukte angeboten. Durch Chatbots werden Ein- und Ausgaben von Anwendungssystemen über natürliche Sprache realisiert. Dadurch ist die Automatisierung von unternehmensexterner Kommunikation (z. B. mit Kunden) aber auch von unternehmensinternen Assistenztätigkeiten möglich. Der Beitrag diskutiert die Auswirkungen von Softwarerobotern auf die Arbeitswelt anhand von Anwendungsbeispielen und erläutert die unternehmensindividuelle Entscheidung über den Einsatz von Softwarerobotern anhand von Effektivitäts- und Effizienzzielen.
Am Beispiel der Telekommunikationsindustrie zeigt der Beitrag eine konkrete Ausgestaltung anwendungsorientierter Forschung, die sowohl für die Praxis als auch für die Wissenschaft nutzen- und erkenntnisbringend ist. Forschungsgegenstand sind die Referenzmodelle des Industriegremiums TM Forum, die von vielen Telekommunikationsunternehmen zur Transformation ihrer Strukturen und Systeme genutzt werden. Es wird die langjährige Forschungstätigkeit bei der Weiterentwicklung und Anwendung dieser Referenzmodelle beschrieben. Dabei wird ein konsequent gestaltungsorientierter Forschungsansatz verfolgt. Das Zusammenspiel aus kontinuierlicher Weiterentwicklung in Zusammenarbeit mit einem Industriegremium und der Anwendung in vielfältigen Praxisprojekten führt zu einer erfolgreichen Symbiose aus praktischer Nutzengenerierung sowie wissenschaftlichem Erkenntnisgewinn. Der Beitrag stellt den gewählten Forschungsansatz anhand konkreter Beispiele vor. Darauf basierend werden Empfehlungen und Herausforderungen für eine gestaltungs- und praxisorientierte Forschung diskutiert.
The molecular weight properties of lignins are one of the key elements that need to be analyzed for a successful industrial application of these promising biopolymers. In this study, the use of 1H NMR as well as diffusion-ordered spectroscopy (DOSY NMR), combined with multivariate regression methods, was investigated for the determination of the molecular weight (Mw and Mn) and the polydispersity of organosolv lignins (n = 53, Miscanthus x giganteus, Paulownia tomentosa, and Silphium perfoliatum). The suitability of the models was demonstrated by cross validation (CV) as well as by an independent validation set of samples from different biomass origins (beech wood and wheat straw). CV errors of ca. 7–9 and 14–16% were achieved for all parameters with the models from the 1H NMR spectra and the DOSY NMR data, respectively. The prediction errors for the validation samples were in a similar range for the partial least squares model from the 1H NMR data and for a multiple linear regression using the DOSY NMR data. The results indicate the usefulness of NMR measurements combined with multivariate regression methods as a potential alternative to more time-consuming methods such as gel permeation chromatography.
In this study, a recently proposed NMR standardization approach by 2H integral of deuterated solvent for quantitative multicomponent analysis of complex mixtures is presented. As a proof of principle, the existing NMR routine for the analysis of Aloe vera products was modified. Instead of using absolute integrals of targeted compounds and internal standard (nicotinamide) from 1H-NMR spectra, quantification was performed based on the ratio of a particular 1H-NMR compound integral and 2H-NMR signal of deuterated solvent D2O. Validation characteristics (linearity, repeatability, accuracy) were evaluated and the results showed that the method has the same precision as internal standardization in case of multicomponent screening. Moreover, a dehydration process by freeze drying is not necessary for the new routine. Now, our NMR profiling of A. vera products needs only limited sample preparation and data processing. The new standardization methodology provides an appealing alternative for multicomponent NMR screening. In general, this novel approach, using standardization by 2H integral, benefits from reduced sample preparation steps and uncertainties, and is recommended in different application areas (purity determination, forensics, pharmaceutical analysis, etc.).
The investigation of the possibility to determine various characteristics of powder heparin (n = 115) was carried out with infrared spectroscopy. The evaluation of heparin samples included several parameters such as purity grade, distributing company, animal source as well as heparin species (i.e. Na-heparin, Ca-heparin, and heparinoids). Multivariate analysis using principal component analysis (PCA), soft independent modelling of class analogy (SIMCA), and partial least squares – discriminant analysis (PLS-DA) were applied for the modelling of spectral data. Different pre-processing methods were applied to IR spectral data; multiplicative scatter correction (MSC) was chosen as the most relevant.
Obtained results were confirmed by nuclear magnetic resonance (NMR) spectroscopy. Good predictive ability of this approach demonstrates the potential of IR spectroscopy and chemometrics for screening of heparin quality. This approach, however, is designed as a screening tool and is not considered as a replacement for either of the methods required by USP and FDA.
Quantitative nuclear magnetic resonance (qNMR) is routinely performed by the internal or external standardization. The manuscript describes a simple alternative to these common workflows by using NMR signal of another active nuclei of calibration compound. For example, for any arbitrary compound quantification by NMR can be based on the use of an indirect concentration referencing that relies on a solvent having both 1H and 2H signals. To perform high-quality quantification, the deuteration level of the utilized deuterated solvent has to be estimated.
In this contribution the new method was applied to the determination of deuteration levels in different deuterated solvents (MeOD, ACN, CDCl3, acetone, benzene, DMSO-d6). Isopropanol-d6, which contains a defined number of deuterons and protons, was used for standardization. Validation characteristics (precision, accuracy, robustness) were calculated and the results showed that the method can be used in routine practice. Uncertainty budget was also evaluated. In general, this novel approach, using standardization by 2H integral, benefits from reduced sample preparation steps and uncertainties, and can be applied in different application areas (purity determination, forensics, pharmaceutical analysis, etc.).
Heparin is a natural polysaccharide, which plays essential role in many biological processes. Alterations in building blocks can modify biological roles of commercial heparin products, due to significant changes in the conformation of the polymer chain. The variability structure of heparin leads to difficulty in quality control using different analytical methods, including infrared (IR) spectroscopy. In this paper molecular modelling of heparin disaccharide subunits was performed using quantum chemistry. The structural and spectral parameters of these disaccharides have been calculated using RHF/6-311G. In addition, over-sulphated chondroitin sulphate disaccharide was studied as one of the most widespread contaminants of heparin. Calculated IR spectra were analyzed with respect to specific structure parameters. IR spectroscopic fingerprint was found to be sensitive to substitution pattern of disaccharide subunits. Vibrational assignments of calculated spectra were correlated with experimental IR spectral bands of native heparin. Chemometrics was used to perform multivariate analysis of simulated spectral data.
Lignin is a promising renewable biopolymer being investigated worldwide as an environmentally benign substitute of fossil-based aromatic compounds, e.g. for the use as an excipient with antioxidant and antimicrobial properties in drug delivery or even as active compound. For its successful implementation into process streams, a quick, easy, and reliable method is needed for its molecular weight determination. Here we present a method using 1H spectra of benchtop as well as conventional NMR systems in combination with multivariate data analysis, to determine lignin’s molecular weight (Mw and Mn) and polydispersity index (PDI). A set of 36 organosolv lignin samples (from Miscanthus x giganteus, Paulownia tomentosa and Silphium perfoliatum) was used for the calibration and cross validation, and 17 samples were used as external validation set. Validation errors between 5.6% and 12.9% were achieved for all parameters on all NMR devices (43, 60, 500 and 600 MHz). Surprisingly, no significant difference in the performance of the benchtop and high-field devices was found. This facilitates the application of this method for determining lignin’s molecular weight in an industrial environment because of the low maintenance expenditure, small footprint, ruggedness, and low cost of permanent magnet benchtop NMR systems.
NMR standardization approach that uses the 2H integral of deuterated solvent for quantitative multinuclear analysis of pharmaceuticals is described. As a proof of principle, the existing NMR procedure for the analysis of heparin products according to US Pharmacopeia monograph is extended to the determination of Na+ and Cl- content in this matrix. Quantification is performed based on the ratio of a 23Na (35Cl) NMR integral and 2H NMR signal of deuterated solvent, D2O, acquired using the specific spectrometer hardware. As an alternative, the possibility of 133Cs standardization using the addition of Cs2CO3 stock solution is shown. Validation characteristics (linearity, repeatability, sensitivity) are evaluated. A holistic NMR profiling of heparin products can now also be used for the quantitative determination of inorganic compounds in a single analytical run using a single sample. In general, the new standardization methodology provides an appealing alternative for the NMR screening of inorganic and organic components in pharmaceutical products.
Although several successful applications of benchtop nuclear magnetic resonance (NMR) spectroscopy in quantitative mixture analysis exist, the possibility of calibration transfer remains mostly unexplored, especially between high- and low-field NMR. This study investigates for the first time the calibration transfer of partial least squares regressions [weight average molecular weight (Mw) of lignin] between high-field (600 MHz) NMR and benchtop NMR devices (43 and 60 MHz). For the transfer, piecewise direct standardization, calibration transfer based on canonical correlation analysis, and transfer via the extreme learning machine auto-encoder method are employed. Despite the immense resolution difference between high-field and low-field NMR instruments, the results demonstrate that the calibration transfer from high- to low-field is feasible in the case of a physical property, namely, the molecular weight, achieving validation errors close to the original calibration (down to only 1.2 times higher root mean square errors). These results introduce new perspectives for applications of benchtop NMR, in which existing calibrations from expensive high-field instruments can be transferred to cheaper benchtop instruments to economize.
Das Gesundheitswesen ist konfrontiert mit steigenden Kosten und einer immer schwieriger werdenden Personalsituation. Zeitgleich versprechen moderne Sprachsteuerungssysteme Prozesse in Arztpraxen und Krankenhäusern zu verschlanken und Vorgänge zu beschleunigen. Dennoch wird derzeit der Einsatz von Sprachsteuerungssystemen in Arztpraxen oder Krankenhäusern nur selten beobachtet, was auch an den besonders strengen Datenschutzauflagen der Datenschutzgrundverordnung (DSGVO) liegt. Darüber hinaus wirft die niedrige Nutzungsrate die Frage nach den konkreten Anforderungen und ihrer Umsetzbarkeit auf, was durch den vorliegenden Beitrag adressiert wird, indem die Ergebnisse von Interviews mit acht medizinischen Fachexperten ausgewertet werden. Ergänzend wird die technische Umsetzbarkeit einzelner Anforderungen mit unterschiedlichen Cloud-Anbietern erprobt.
We study the possibility to fabricate an arbitrary phase mask in a one-step laser-writing process inside the volume of an optical glass substrate. We derive the phase mask from a Gerchberg–Saxton-type algorithm as an array and create each individual phase shift using a refractive index modification of variable axial length. We realize the variable axial length by superimposing refractive index modifications induced by an ultra-short pulsed laser at different focusing depth. Each single modification is created by applying 1000 pulses with 15 μJ pulse energy at 100 kHz to a fixed spot of 25 μm diameter and the focus is then shifted axially in steps of 10 μm. With several proof-of-principle examples, we show the feasibility of our method. In particular, we identify the induced refractive index change to about a value of Δn=1.5⋅10−3. We also determine our current limitations by calculating the overlap in the form of a scalar product and we discuss possible future improvements.
This study addresses a proof-of-concept experiment with a biocompatible screen-printed carbon electrode deposited onto a biocompatible and biodegradable substrate, which is made of fibroin, a protein derived from silk of the Bombyx mori silkworm. To demonstrate the sensor performance, the carbon electrode is functionalized as a glucose biosensor with the enzyme glucose oxidase and encapsulated with a silicone rubber to ensure biocompatibility of the contact wires. The carbon electrode is fabricated by means of thick-film technology including a curing step to solidify the carbon paste. The influence of the curing temperature and curing time on the electrode morphology is analyzed via scanning electron microscopy. The electrochemical characterization of the glucose biosensor is performed by amperometric/voltammetric measurements of different glucose concentrations in phosphate buffer. Herein, systematic studies at applied potentials from 500 to 1200 mV to the carbon working electrode (vs the Ag/AgCl reference electrode) allow to determine the optimal working potential. Additionally, the influence of the curing parameters on the glucose sensitivity is examined over a time period of up to 361 days. The sensor shows a negligible cross-sensitivity toward ascorbic acid, noradrenaline, and adrenaline. The developed biocompatible biosensor is highly promising for future in vivo and epidermal applications.
Retinal vessels are similar to cerebral vessels in their structure and function. Moderately low oscillation frequencies of around 0.1 Hz have been reported as the driving force for paravascular drainage in gray matter in mice and are known as the frequencies of lymphatic vessels in humans. We aimed to elucidate whether retinal vessel oscillations are altered in Alzheimer's disease (AD) at the stage of dementia or mild cognitive impairment (MCI). Seventeen patients with mild-to-moderate dementia due to AD (ADD); 23 patients with MCI due to AD, and 18 cognitively healthy controls (HC) were examined using Dynamic Retinal Vessel Analyzer. Oscillatory temporal changes of retinal vessel diameters were evaluated using mathematical signal analysis. Especially at moderately low frequencies around 0.1 Hz, arterial oscillations in ADD and MCI significantly prevailed over HC oscillations and correlated with disease severity. The pronounced retinal arterial vasomotion at moderately low frequencies in the ADD and MCI groups would be compatible with the view of a compensatory upregulation of paravascular drainage in AD and strengthen the amyloid clearance hypothesis.
Edge-based and face-based smoothed finite element methods (ES-FEM and FS-FEM, respectively) are modified versions of the finite element method allowing to achieve more accurate results and to reduce sensitivity to mesh distortion, at least for linear elements. These properties make the two methods very attractive. However, their implementation in a standard finite element code is nontrivial because it requires heavy and extensive modifications to the code architecture. In this article, we present an element-based formulation of ES-FEM and FS-FEM methods allowing to implement the two methods in a standard finite element code with no modifications to its architecture. Moreover, the element-based formulation permits to easily manage any type of element, especially in 3D models where, to the best of the authors' knowledge, only tetrahedral elements are used in FS-FEM applications found in the literature. Shape functions for non-simplex 3D elements are proposed in order to apply FS-FEM to any standard finite element.