Refine
Year of publication
- 2002 (130) (remove)
Document Type
- Article (92)
- Conference Proceeding (25)
- Book (12)
- Patent (1)
Language
- English (130) (remove)
Keywords
- Blitzschutz (2)
- Biomedizinische Technik (1)
- Bruchmechanik (1)
- CAD (1)
- CAD ; (1)
- Direkter Blitzschlag (1)
- Einspielen <Werkstoff> (1)
- Elektromagnetischer Schutzschild (1)
- Erneuerbare Energien (1)
- Gasturbine (1)
- Hybridsystem (1)
- Induzierte Spannungen (1)
- Lightning (1)
- Lightning protection (1)
- Lightning protection system (1)
- Magnetische Felder (1)
- Micro turbine (1)
- Mikrogasturbine (1)
- Photovoltaikanlage (1)
- Ratcheting (1)
- Risikoabwägung (1)
- Shakedown (1)
- Stahlbetonkonstruktion (1)
- Windenergieanlage (1)
- civil engineering (1)
- electromagnetic shielding (1)
- hybrid system (1)
- induced voltage (1)
- linear kinematic hardening (1)
- magnetic field (1)
- material shakedown (1)
- nonlinear kinematic hardening (1)
- photovoltaic system (1)
- protection measures (1)
- ratchetting (1)
- reinforced concrete (1)
- renewable energy (1)
- risk assessment (1)
- shakedown (1)
- wind turbine (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (46)
- Fachbereich Energietechnik (21)
- Fachbereich Elektrotechnik und Informationstechnik (20)
- INB - Institut für Nano- und Biotechnologien (16)
- Fachbereich Chemie und Biotechnologie (13)
- IfB - Institut für Bioengineering (10)
- Fachbereich Luft- und Raumfahrttechnik (8)
- Solar-Institut Jülich (8)
- Fachbereich Wirtschaftswissenschaften (7)
- Fachbereich Gestaltung (2)
- Fachbereich Architektur (1)
- Fachbereich Bauingenieurwesen (1)
- Fachbereich Maschinenbau und Mechatronik (1)
- Nowum-Energy (1)
Coincident events in two scintillator crystals coupled to photomultipliers (PMT) are detected by processing just the digital data of the recorded pulses. For this purpose the signals from both PMTs are continuously sampled by free-running ADCs at a sampling rate of 40 MHz. For each sampled pulse the starting time is determined by processing the pulse data. Even a fairly simple interpolating algorithm results in a FWHM of about 2 ns.
Within the developments for the Crystal Clear small animal PET project (CLEARPET) a dual head PET system has been established. The basic principle is the early digitization of the detector pulses by free running ADCs. The determination of the γ-energy and also the coincidence detection is performed by data processing of the sampled pulses on the host computer. Therefore a time mark is attached to each pulse identifying the current cycle of the 40 MHz sampling clock. In order to refine the time resolution the pulse starting time is interpolated from the samples of the pulse rise. The detector heads consist of multichannel PMTs with a single LSO scintillator crystal coupled to each channel. For each PMT only one ADC is required. The position of an event is obtained separately from trigger signals generated for each single channel. An FPGA is utilized for pulse buffering, generation of the time mark and for the data transfer to the host via a fast I/O-interface.
In IEC 61312-2 equations for the assessment of the magnetic fields inside structures due to a direct lightning strike are given. These equations are based on computer simulations for shields consisting of a single-layer steel grid of a given mesh width. Real constructions, however, contain at least two layers of reinforcement steel grids. The objective of this study was to experimentally determine the additional shielding effectiveness of a second reinforcement layer compared to a single-layer grid. To this end, simulated structures were set up in the high current laboratory. The structures consisted of cubic cages of 2 m side length with one or with two reinforcement grids, respectively. The structures were exposed to direct lightning currents representing the variety of anticipated lightning current waveforms. The magnetic fields and their derivatives at several positions inside the structure as well as the voltage between “floor” and “roof” in the center were determined for different current injection points. From these data the improvement of the shielding caused by a second reinforcement layer is derived.