Refine
Year of publication
- 2015 (125) (remove)
Document Type
- Article (125) (remove)
Has Fulltext
- no (125) (remove)
Keywords
- Booster Station (1)
- Discrete Optimization (1)
- Gamma distribution (1)
- Goodness-of-fit test (1)
- Independence test (1)
- Parametric bootstrap (1)
- Pump System (1)
- Technical Operations Research (TOR) (1)
- Vapnik–Čhervonenkis class (1)
- availability (1)
- energy efficiency (1)
- energy transfer (1)
- heating system (1)
- mixed-integer linear programming (1)
- programming (1)
- sustainability (1)
- system optimization (1)
- system synthesis (1)
- technical operations research (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (43)
- INB - Institut für Nano- und Biotechnologien (31)
- Fachbereich Wirtschaftswissenschaften (23)
- Fachbereich Chemie und Biotechnologie (20)
- IfB - Institut für Bioengineering (11)
- Fachbereich Energietechnik (9)
- Fachbereich Elektrotechnik und Informationstechnik (8)
- Fachbereich Maschinenbau und Mechatronik (8)
- Fachbereich Luft- und Raumfahrttechnik (6)
- Fachbereich Architektur (4)
- Fachbereich Bauingenieurwesen (4)
- IBB - Institut für Baustoffe und Baukonstruktionen (1)
- Institut fuer Angewandte Polymerchemie (1)
- Nowum-Energy (1)
- Solar-Institut Jülich (1)
- Sonstiges (1)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (1)
In this study we show an optical biosensor concept, based on elastic light scattering from sapphire microspheres. Transmitted and elastic scattering intensity of the microspheres (radius 500 μm, refractive index 1.77) on an optical fiber half coupler is analyzed at 1510 nm. The 0.43 nm angular mode spacing of the resonances is comparable to the angular mode spacing value estimated using the optical size of the microsphere. The spectral linewidths of the resonances are in the order of 0.01 nm, which corresponds to quality factors of approximately 105. A polydopamine layer is used as a functionalizing agent on sapphire microspherical resonators in view of biosensor implementation. The varying layer thickness on the microsphere is determined as a function of the resonance wavelength shift. It is shown that polymer functionalization has a minor effect on the quality factor. This is a promising step toward the development of an optical biosensor.
An amperometric enzyme biosensor has been applied for the detection of adrenaline. The adrenaline biosensor has been prepared by modification of an oxygen electrode with the enzyme laccase that operates at a broad pH range between pH 3.5 to pH 8. The enzyme molecules were immobilized via cross-linking with glutaraldehyde. The sensitivity of the developed adrenaline biosensor in different pH buffer solutions has been studied.
A concept for a new generation of an integrated multi-functional biosensor/actuator system is developed, which is based on biomolecular logic principles. Such a system is expected to be able to detect multiple biochemical input signals simultaneously and in real-time and convert them into electrical output signals with logical operations such as OR, AND, etc. The system can be designed as a closed-loop drug release device triggered by an enzyme logic gate, while the release of the drug induced by the actuator at the required dosage and timing will be controlled by an additional drug sensor. Thus, the system could help to make an accurate and specific diagnosis. The presented concept is exemplarily demonstrated by using an enzyme logic gate based on a glucose/glucose oxidase system, a temperature-responsive hydrogel mimicking the actuator function and an insulin (drug) sensor. In this work, the results of functional testing of individual amperometric glucose and insulin sensors as well as an impedimetric sensor for the detection of the hydrogel swelling/shrinking are presented.
The chemical imaging sensor is a field-effect sensor which is able to visualize both the distribution of ions (in LAPS mode) and the distribution of impedance (in SPIM mode) inthe sample. In this study, a novel wound-healing assay is proposed, in which the chemical imaging sensor operated in SPIM mode is applied to monitor the defect of a cell layer brought into proximity of the sensing surface.A reduced impedance inside the defect, which was artificially formed ina cell layer, was successfully visualized in a photocurrent image.
The chemical imaging sensor was applied to in-situ pH imaging of the solution in the vicinity of a corroding surface of stainless steel under potentiostatic polarization. A test piece of polished stainless steel was placed on the sensing surface leaving a narrow gap filled with artificial seawater and the stainless steel was corroded under polarization. The pH images obtained during polarization showed correspondence between the region of lower pH and the site of corrosion. It was also found that the pH value in the gap became as low as 2 by polarization, which triggered corrosion.
We introduce a new way to measure the forecast effort that analysts devote to their earnings forecasts by measuring the analyst's general effort for all covered firms. While the commonly applied effort measure is based on analyst behaviour for one firm, our measure considers analyst behaviour for all covered firms. Our general effort measure captures additional information about analyst effort and thus can identify accurate forecasts. We emphasise the importance of investigating analyst behaviour in a larger context and argue that analysts who generally devote substantial forecast effort are also likely to devote substantial effort to a specific firm, even if this effort might not be captured by a firm-specific measure. Empirical results reveal that analysts who devote higher general forecast effort issue more accurate forecasts. Additional investigations show that analysts' career prospects improve with higher general forecast effort. Our measure improves on existing methods as it has higher explanatory power regarding differences in forecast accuracy than the commonly applied effort measure. Additionally, it can address research questions that cannot be examined with a firm-specific measure. It provides a simple but comprehensive way to identify accurate analysts.
Simulating the electromagnetic‐thermal treatment of thin aluminium layers for adhesion improvement
(2015)
A composite layer material used in packaging industry is made from joining layers of different materials using an adhesive. An important processing step in the production of aluminium-containing composites is the surface treatment and consequent coating of adhesive material on the aluminium surface. To increase adhesion strength between aluminium layer and the adhesive material, the foil is heat treated. For efficient heating, induction heating was considered as state-of-the-art treatment process. Due to the complexity of the heating process and the unpredictable nature of the heating source, the control of the process is not yet optimised. In this work, a finite element analysis of the process was established and various process parameters were studied. The process was simplified and modelled in 3D. The numerical model contains an air domain, an aluminium layer and a copper coil fitted with a magnetic field concentrating material. The effect of changing the speed of the aluminium foil (or rolling speed) was studied with the change of the coil current. Statistical analysis was used for generating a general control equation of coil current with changing rolling speed.
High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors. In this work, a Si-based sensor chip containing Pt interdigitated electrodes covered with a thin BST layer (485 nm) has been developed for multi-parameter chemical sensing. The chip has been applied for the contactless measurement of the electrolyte conductivity, the detection of adsorbed charged macromolecules (positively charged polyelectrolytes of polyethylenimine) and the concentration of hydrogen peroxide (H2O2) vapor. The experimental results of functional testing of individual sensors are presented. The mechanism of the BST sensitivity to charged polyelectrolytes and H2O2 vapor has been proposed and discussed.
Opioid Analgesia in P450 Gene Cluster Knockout Mice: A Search for Analgesia-Relevant Isoforms
(2015)
Cytochrome b5 Is a Major Determinant of Human Cytochrome P450 CYP2D6 and CYP3A4 Activity In Vivo s
(2015)
Offene und geschlossene WLAN: Rechtliche Hürden bei Betrieb eines öffentlichen Internetzugangs
(2015)
System mit Hülle - Die innovativen Bauten der Steiff-Spielwarenfabrik in Giengen an der Brenz
(2015)