Refine
Year of publication
Document Type
- Article (625) (remove)
Keywords
- Multimediamarkt (6)
- Hot S-parameter (2)
- Literaturanalyse (2)
- MINLP (2)
- Referenzmodellierung (2)
- 3-D printing (1)
- Anwendungsorientierter Forschungsansatz (1)
- Arbeit 4.0 (1)
- Automated driving (1)
- Automotive application (1)
- Benchmark (1)
- Bloom’s Taxonomy (1)
- Booster Stations (1)
- Buffering Capacity (1)
- CAV (1)
- Chance Constraint (1)
- Chaostheorie (1)
- Chatbots (1)
- Circuit simulation (1)
- Competence Developing Games (1)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (625) (remove)
Die Durchführung einer systematischen Literaturrecherche ist eine zentrale Kompetenz wissenschaftlichen Arbeitens und bildet daher einen festen Ausbildungsbestandteil von Bachelor- und Masterstudiengängen. In entsprechenden Lehrveranstaltungen werden Studierende zwar mit den grundlegenden Hilfsmitteln zur Suche und Verwaltung von Literatur vertraut gemacht, allerdings werden die Potenziale textanalytischer Methoden und Anwendungssysteme (Text Mining, Text Analytics) dabei zumeist nicht abgedeckt. Folglich werden Datenkompetenzen, die zur systemgestützten Analyse und Erschließung von Literaturdaten erforderlich sind, nicht hinreichend ausgeprägt. Um diese Kompetenzlücke zu adressieren, ist an der Hochschule Osnabrück eine Lehrveranstaltung konzipiert und projektorientiert umgesetzt worden, die sich insbesondere an Studierende wirtschaftswissenschaftlicher Studiengänge richtet. Dieser Beitrag dokumentiert die fachliche sowie technische Ausgestaltung dieser Veranstaltung und zeigt Potenziale für die künftige Weiterentwicklung auf.
Verfügbarkeit und Nachhaltigkeit sind wichtige Anforderungen bei der Planung langlebiger technischer Systeme. Meist werden bei Lebensdaueroptimierungen lediglich einzelne Komponenten vordefinierter Systeme untersucht. Ob eine optimale Lebensdauer eine gänzlich andere Systemvariante bedingt, wird nur selten hinterfragt. Technical Operations Research (TOR) erlaubt es, aus Obermengen technischer Systeme automatisiert die lebensdaueroptimale Systemstruktur auszuwählen. Der Artikel zeigt dies am Beispiel eines hydrostatischen Getriebes.
Kurzschlußstromberechnung
(1980)
Die Verbindung der Welten dressierter Elektronen und grenzenloser Kreativität bietet ein großes Potential; zum Beispiel bei modernen Skulpturen, deren Form sich durch Motoren verändern kann. An der FH Aachen wurde ein solches Projekt verwirklicht: Eine Matrix aus Holzkugeln kann Piktogramme anzeigen, aber auch mathematische Funktionen visualisieren. In diesem Artikel beschreiben wir die clevere Ansteuerung der Motoren.
Für viele Zwecke ist es nützlich, von einem technischen System ein mathematisches Modell zu haben. Für Systeme, die sich durch eine Verzögerung höherer Ordnung mit oder ohne Ausgleich beschreiben lassen, wird ein Identifizierungsverfahren vorgestellt, das aus gemessenen Zeitfunktionen die Bestimmung einer Übertragungsfunktion ermöglicht. Die Systeme werden dabei durch Testsignale erregt. Die Modellkoeffizienten werden dann mit Hilfe eines Integrationsverfahrens aus dem Testsignal und der Antwort des Systems auf dieses Testsignal bestimmt. Ein praktisches Beispiel zeigt die Leistungsfähigkeit des Verfahrens.
Information Channels
(2000)
31P MR spectroscopic imaging of the human prostate provides information about phosphorylated metabolites that could be used for prostate cancer characterization. The sensitivity of a magnetic field strength of 7 T might enable 3D 31P MR spectroscopic imaging with relevant spatial resolution in a clinically acceptable measurement time. To this end, a 31P endorectal coil was developed and combined with an eight-channel 1H body-array coil to relate metabolic information to anatomical location. An extensive safety validation was performed to evaluate the specific absorption rate, the radiofrequency field distribution, and the temperature distribution of both coils. This validation consisted of detailed Finite Integration Technique simulations, confirmed by MR thermometry and Burn:x-wiley:07403194:media:MRM24175:tex2gif-stack-1 measurements in a phantom and in vivo temperature measurements. The safety studies demonstrated that the presence of the 31P endorectal coil had no influence on the specific absorption rate levels and temperature distribution of the external eight-channel 1H array coil. To stay within a 10 g averaged local specific absorption rate of 10 W/kg, a maximum time-averaged input power of 33 W for the 1H array coil was allowed. For transmitting with the 31P endorectal coil, our safety limit of less than 1°C temperature increase in vivo during a 15-min MR spectroscopic imaging experiment was reached at a time-averaged input power of 1.9 W. With this power setting, a second in vivo measurement was performed on a healthy volunteer. Using adiabatic excitation, 3D 31P MR spectroscopic imaging produced spectra from the entire prostate in 18 min with a spatial resolution of 4 cm3. The spectral resolution enabled the separate detection of phosphocholine, phosphoethanolamine, inorganic phosphate, and other metabolites that could play an important role in the characterization of prostate cancer.
Objectives
To assess the image quality of T2-weighted (T2w) magnetic resonance imaging of the prostate and the visibility of prostate cancer at 7 Tesla (T).
Materials & methods
Seventeen prostate cancer patients underwent T2w imaging at 7T with only an external transmit/receive array coil. Three radiologists independently scored images for image quality, visibility of anatomical structures, and presence of artefacts. Krippendorff’s alpha and weighted kappa statistics were used to assess inter-observer agreement. Visibility of prostate cancer lesions was assessed by directly linking the T2w images to the confirmed location of prostate cancer on histopathology.
Results
T2w imaging at 7T was achievable with ‘satisfactory’ (3/5) to ‘good’ (4/5) quality. Visibility of anatomical structures was predominantly scored as ‘satisfactory’ (3/5) and ‘good’ (4/5). If artefacts were present, they were mostly motion artefacts and, to a lesser extent, aliasing artefacts and noise. Krippendorff’s analysis revealed an α = 0.44 between three readers for the overall image quality scores. Clinically significant cancer lesions in both peripheral zone and transition zone were visible at 7T.
Conclusion
T2w imaging with satisfactory to good quality can be routinely acquired, and cancer lesions were visible in patients with prostate cancer at 7T using only an external transmit/receive body array coil.