Refine
Year of publication
Document Type
- Article (625)
- Conference Proceeding (296)
- Book (113)
- Part of a Book (61)
- Patent (15)
- Report (9)
- Other (8)
- Contribution to a Periodical (6)
- Course Material (6)
- Doctoral Thesis (6)
- Bachelor Thesis (1)
- Video (1)
- Poster (1)
- Review (1)
- Talk (1)
Language
- English (693)
- German (456)
- Multiple languages (1)
Keywords
- Multimediamarkt (7)
- Enterprise Architecture (5)
- MINLP (5)
- Engineering optimization (4)
- Gamification (4)
- Serious Game (4)
- Auslenkung (3)
- Digitale Transformation (3)
- Digitalisierung (3)
- Education (3)
- Javasimulation (3)
- Literaturanalyse (3)
- Optimization (3)
- Powertrain (3)
- Referenzmodellierung (3)
- Robotic Process Automation (3)
- Technical Operations Research (3)
- Telecommunication (3)
- Amplitude (2)
- Autonomous mobile robots (2)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (1150) (remove)
Objectives
The aim of this study was to identify characteristics of phosphorus (³¹P) spectra of the human prostate and to investigate changes of individual phospholipid metabolites in prostate cancer through in vivo ³¹P magnetic resonance spectroscopic imaging (MRSI) at 7 T.
Materials and Methods
In this institutional review board–approved study, 15 patients with biopsy-proven prostate cancer underwent T₂-weighted magnetic resonance imaging and 3-dimensional ³¹P MRSI at 7 T. Voxels were selected at the tumor location, in normal-appearing peripheral zone tissue, normal-appearing transition zone tissue, and in the base of the prostate close to the seminal vesicles. Phosphorus metabolite ratios were determined and compared between tissue types.
Results
Signals of phosphoethanolamine (PE) and phosphocholine (PC) were present and well resolved in most ³¹P spectra in the prostate. Glycerophosphocholine signals were observable in 43% of the voxels in malignant tissue, but in only 10% of the voxels in normal-appearing tissue away from the seminal vesicles. In many spectra, independent of tissue type, 2 peaks resonated in the chemical shift range of inorganic phosphate, possibly representing 2 separate pH compartments. The PC/PE ratio in the seminal vesicles was highly elevated compared with the prostate in 5 patients. A considerable overlap of ³¹P metabolite ratios was found between prostate cancer and normal-appearing prostate tissue, preventing direct discrimination of these tissues. The only 2 patients with high Gleason scores tumors (≥4+5) presented with high PC and glycerophosphocholine levels in their cancer lesions.
Conclusions
Phosphorus MRSI at 7 T shows distinct features of phospholipid metabolites in the prostate gland and its surrounding structures. In this exploratory study, no differences in ³¹P metabolite ratios were observed between prostate cancer and normal-appearing prostate tissue possibly because of the partial volume effects of small tumor foci in large MRSI voxels.
Phase Repeatable Synthesizers as a New Harmonic Phase Standard for Nonlinear Network Analysis
(2018)
Performance Investigations of the IP Multicast Architecture / Hermanns, Oliver ; Schuba, Marko
(1995)
In this study, the performance of an integrated body-imaging array for 7 T with 32 radiofrequency (RF) channels under consideration of local specific absorption rate (SAR), tissue temperature, and thermal dose limits was evaluated and the imaging performance was compared with a clinical 3 T body coil.
Thirty-two transmit elements were placed in three rings between the bore liner and RF shield of the gradient coil. Slice-selective RF pulse optimizations for B1 shimming and spokes were performed for differently oriented slices in the body under consideration of realistic constraints for power and local SAR. To improve the B1+ homogeneity, safety assessments based on temperature and thermal dose were performed to possibly allow for higher input power for the pulse optimization than permissible with SAR limits.
The results showed that using two spokes, the 7 T array outperformed the 3 T birdcage in all the considered regions of interest. However, a significantly higher SAR or lower duty cycle at 7 T is necessary in some cases to achieve similar B1+ homogeneity as at 3 T. The homogeneity in up to 50 cm-long coronal slices can particularly benefit from the high RF shim performance provided by the 32 RF channels. The thermal dose approach increases the allowable input power and the corresponding local SAR, in one example up to 100 W/kg, without limiting the exposure time necessary for an MR examination.
In conclusion, the integrated antenna array at 7 T enables a clinical workflow for body imaging and comparable imaging performance to a conventional 3 T clinical body coil.
Die NATO definiert den Cyberspace als die "Umgebung, die durch physische und nicht-physische Bestandteile zum Speichern, Ändern, und Austauschen von Daten mit Hilfe von Computer-Netzwerken" [NATO CCDCOE]. Darüber hinaus ist es ein Medium menschlicher Interaktion. IT Angriffe sind feindselige, nichtkooperative Interaktionen, die mittels Konflikttheorie beschrieben werden können. Durch die Anwendung dieses Gedankengebäudes auf IT Sicherheit von Organisationen können eine Reihe von Verbesserungen in Unternehmen identifiziert werden.