Article
Refine
Year of publication
- 2019 (52) (remove)
Document Type
- Article (52) (remove)
Keywords
- Achilles tendon (1)
- Architectural gear ratio (1)
- Assistive technology (1)
- Automatic control (1)
- Goodness-of-fit test (1)
- Human-Computer interaction (1)
- Multi-sample problem (1)
- Parametric bootstrap (1)
- Rehabilitation engineering (1)
- Running (1)
- Stiffness (1)
- Tendon properties (1)
- Volume of confidence regions (1)
- asymptotic relative efficiency (1)
- frequency mixing magnetic detection (1)
- likelihood ratio test (1)
- magnetic actuation (1)
- magnetic sandwich immunoassay (1)
- magnetic separation (1)
- magnetic tweezers (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (52) (remove)
The paper deals with an asymptotic relative efficiency concept for confidence regions of multidimensional parameters that is based on the expected volumes of the confidence regions. Under standard conditions the asymptotic relative efficiencies of confidence regions are seen to be certain powers of the ratio of the limits of the expected volumes. These limits are explicitly derived for confidence regions associated with certain plugin estimators, likelihood ratio tests and Wald tests. Under regularity conditions, the asymptotic relative efficiency of each of these procedures with respect to each one of its competitors is equal to 1. The results are applied to multivariate normal distributions and multinomial distributions in a fairly general setting.
For performing point-of-care molecular diagnostics, magnetic immunoassays constitute a promising alternative to established enzyme-linked immunosorbent assays (ELISA) because they are fast, robust and sensitive. Simultaneous detection of multiple biomolecular targets from one body fluid sample is desired. The aim of this work is to show that multiplex magnetic immunodetection based on magnetic frequency mixing by means of modular immunofiltration columns prepared for different targets is feasible. By calculations of the magnetic response signal, the required spacing between the modules was determined. Immunofiltration columns were manufactured by 3D printing and antibody immobilization was performed in a batch approach. It was shown experimentally that two different target molecules in a sample solution could be individually detected in a single assaying step with magnetic measurements of the corresponding immobilization filters. The arrangement order of the filters and of a negative control did not influence the results. Thus, a simple and reliable approach to multi-target magnetic immunodetection was demonstrated.
The movement of magnetic beads due to a magnetic field gradient is of great interest in different application fields. In this report we present a technique based on a magnetic tweezers setup to measure the velocity factor of magnetically actuated individual superparamagnetic beads in a fluidic environment. Several beads can be tracked simultaneously in order to gain and improve statistics. Furthermore we show our results for different beads with hydrodynamic diameters between 200 and 1000 nm from diverse manufacturers. These measurement data can, for example, be used to determine design parameters for a magnetic separation system, like maximum flow rate and minimum separation time, or to select suitable beads for fixed experimental requirements.