Refine
Year of publication
- 2024 (5)
- 2023 (23)
- 2022 (18)
- 2021 (26)
- 2020 (29)
- 2019 (44)
- 2018 (44)
- 2017 (37)
- 2016 (35)
- 2015 (36)
- 2014 (43)
- 2013 (41)
- 2012 (32)
- 2011 (38)
- 2010 (35)
- 2009 (36)
- 2008 (40)
- 2007 (39)
- 2006 (27)
- 2005 (25)
- 2004 (35)
- 2003 (33)
- 2002 (29)
- 2001 (33)
- 2000 (34)
- 1999 (31)
- 1998 (28)
- 1997 (34)
- 1996 (25)
- 1995 (22)
- 1994 (21)
- 1993 (18)
- 1992 (13)
- 1991 (14)
- 1990 (9)
- 1989 (17)
- 1988 (11)
- 1987 (8)
- 1986 (9)
- 1985 (9)
- 1984 (3)
- 1983 (7)
- 1982 (4)
- 1981 (3)
- 1980 (12)
- 1979 (6)
- 1978 (7)
- 1977 (1)
- 1976 (7)
- 1975 (3)
- 1974 (4)
- 1973 (1)
- 1972 (3)
- 1971 (2)
- 1970 (1)
Document Type
- Article (625)
- Conference Proceeding (296)
- Book (113)
- Part of a Book (61)
- Patent (15)
- Report (9)
- Other (8)
- Contribution to a Periodical (6)
- Course Material (6)
- Doctoral Thesis (6)
- Bachelor Thesis (1)
- Video (1)
- Poster (1)
- Review (1)
- Talk (1)
Language
- English (693)
- German (456)
- Multiple languages (1)
Keywords
- Multimediamarkt (7)
- Enterprise Architecture (5)
- MINLP (5)
- Engineering optimization (4)
- Gamification (4)
- Serious Game (4)
- Auslenkung (3)
- Digitale Transformation (3)
- Digitalisierung (3)
- Education (3)
- Javasimulation (3)
- Literaturanalyse (3)
- Optimization (3)
- Powertrain (3)
- Referenzmodellierung (3)
- Robotic Process Automation (3)
- Technical Operations Research (3)
- Telecommunication (3)
- Amplitude (2)
- Autonomous mobile robots (2)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (1150) (remove)
Vestibular effects of a 7 Tesla MRI examination compared to 1.5 T and 0 T in healthy volunteers
(2014)
Ultra-high-field MRI (7 Tesla (T) and above) elicits more temporary side-effects compared to 1.5 T and 3 T, e.g. dizziness or “postural instability” even after exiting the scanner. The current study aims to assess quantitatively vestibular performance before and after exposure to different MRI scenarios at 7 T, 1.5 T and 0 T. Sway path and body axis rotation (Unterberger's stepping test) were quantitatively recorded in a total of 46 volunteers before, 2 minutes after, and 15 minutes after different exposure scenarios: 7 T head MRI (n = 27), 7 T no RF (n = 22), 7 T only B₀ (n = 20), 7 T in & out B₀ (n = 20), 1.5 T no RF (n = 20), 0 T (n = 15). All exposure scenarios lasted 30 minutes except for brief one minute exposure in 7 T in & out B₀. Both measures were documented utilizing a 3D ultrasound system. During sway path evaluation, the experiment was repeated with eyes both open and closed. Sway paths for all long-lasting 7 T scenarios (normal, no RF, only B₀) with eyes closed were significantly prolonged 2 minutes after exiting the scanner, normalizing after 15 minutes. Brief exposure to 7 T B₀ or 30 minutes exposure to 1.5 T or 0 T did not show significant changes. End positions after Unterberger's stepping test were significantly changed counter-clockwise after all 7 T scenarios, including the brief in & out B₀ exposure. Shorter exposure resulted in a smaller alteration angle. In contrast to sway path, reversal of changes in body axis rotation was incomplete after 15 minutes. 1.5 T caused no rotational changes. The results show that exposure to the 7 Tesla static magnetic field causes only a temporary dysfunction or “over-compensation” of the vestibular system not measurable at 1.5 or 0 Tesla. Radiofrequency fields, gradient switching, and orthostatic dysregulation do not seem to play a role.
Kritische Infrastrukturen sind primäre Ziele krimineller Hacker. Der Deutsche Bundestag reagierte darauf am 25. Juli 2015 mit einem Gesetz zur Verbesserung der Sicherheit von ITSystemen, dem IT-Sicherheitsgesetz. Dies verlangt von Betreibern kritischer Infrastrukturen, angemessene Mindeststandards für organisatorische und technische Sicherheit zu implementieren, um den Betrieb und die Verfügbarkeit dieser Infrastruktur zu gewährleisten. Telekommunikationsunternehmen sind einerseits von diesem Gesetz in besonderem Maße betroffen und verfügen andererseits mit dem Rahmenwerk enhanced Telecom Operations Map (eTOM) über ein international anerkanntes Referenzmodell zur Gestaltung von Geschäftsprozessen in dieser Branche. Da sämtliche Telekommunikationsunternehmen in Deutschland verpflichtet sind, das Gesetz innerhalb eines bestimmten Zeitrahmens zu implementieren, präsentiert dieser Beitrag einen Vorschlag zur Erweiterung von eTOM um die relevanten Anforderungen des deutschen IT-Sicherheitsgesetzes.
Due to the decarbonization of the energy sector, the electric distribution grids are undergoing a major transformation, which is expected to increase the load on the operating resources due to new electrical loads and distributed energy resources. Therefore, grid operators need to gradually move to active grid management in order to ensure safe and reliable grid operation. However, this requires knowledge of key grid variables, such as node voltages, which is why the mass integration of measurement technology (smart meters) is necessary. Another problem is the fact that a large part of the topology of the distribution grids is not sufficiently digitized and models are partly faulty, which means that active grid operation management today has to be carried out largely blindly. It is therefore part of current research to develop methods for determining unknown grid topologies based on measurement data. In this paper, different clustering algorithms are presented and their performance of topology detection of low voltage grids is compared. Furthermore, the influence of measurement uncertainties is investigated in the form of a sensitivity analysis.
This article addresses the need for an innovative technique in plasma shaping, utilizing antenna structures, Maxwell’s laws, and boundary conditions within a shielded environment. The motivation lies in exploring a novel approach to efficiently generate high-energy density plasma with potential applications across various fields. Implemented in an E01 circular cavity resonator, the proposed method involves the use of an impedance and field matching device with a coaxial connector and a specially optimized monopole antenna. This setup feeds a low-loss cavity resonator, resulting in a high-energy density air plasma with a surface temperature exceeding 3500 o C, achieved with a minimal power input of 80 W. The argon plasma, resembling the shape of a simple monopole antenna with modeled complex dielectric values, offers a more energy-efficient alternative compared to traditional, power-intensive plasma shaping methods. Simulations using a commercial electromagnetic (EM) solver validate the design’s effectiveness, while experimental validation underscores the method’s feasibility and practical implementation. Analyzing various parameters in an argon atmosphere, including hot S -parameters and plasma beam images, the results demonstrate the successful application of this technique, suggesting its potential in coating, furnace technology, fusion, and spectroscopy applications.
Objective
To investigate the feasibility of 7T MR imaging of the kidneys utilising a custom-built 8-channel transmit/receive radiofrequency body coil.
Methods
In vivo unenhanced MR was performed in 8 healthy volunteers on a 7T whole-body MR system. After B0 shimming the following sequences were obtained: 1) 2D and 3D spoiled gradient-echo sequences (FLASH, VIBE), 2) T1-weighted 2D in and opposed phase 3) True-FISP imaging and 4) a T2-weighted turbo spin echo (TSE) sequence. Visual evaluation of the overall image quality was performed by two radiologists.
Results
Renal MRI at 7T was feasible in all eight subjects. Best image quality was found using T1-weighted gradient echo MRI, providing high anatomical details and excellent conspicuity of the non-enhanced vasculature. With successful shimming, B1 signal voids could be effectively reduced and/or shifted out of the region of interest in most sequence types. However, T2-weighted TSE imaging remained challenging and strongly impaired because of signal heterogeneities in three volunteers.
Conclusion
The results demonstrate the feasibility and diagnostic potential of dedicated 7T renal imaging. Further optimisation of imaging sequences and dedicated RF coil concepts are expected to improve the acquisition quality and ultimately provide high clinical diagnostic value.