Refine
Year of publication
- 2016 (251) (remove)
Document Type
- Article (113)
- Conference Proceeding (71)
- Part of a Book (27)
- Book (22)
- Other (9)
- Report (5)
- Doctoral Thesis (3)
- Patent (1)
Has Fulltext
- no (251) (remove)
Keywords
- Technical Operations Research (2)
- Additive Manufacturing (1)
- Annulus Fibrosus (1)
- Assessment (1)
- Asymptotic efficiency (1)
- Bacillus atrophaeus (1)
- Balance (1)
- Balanced hypergraph (1)
- Brandfall (1)
- Building Systems (1)
- Business Simulations (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- CellDrum (1)
- Censored data (1)
- Co-managed care (1)
- Collaborative robot (1)
- Computational biomechanics (1)
- Controller Parameter (1)
- DNA biosensor (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (51)
- Fachbereich Chemie und Biotechnologie (36)
- Fachbereich Bauingenieurwesen (35)
- IfB - Institut für Bioengineering (33)
- Fachbereich Elektrotechnik und Informationstechnik (32)
- Fachbereich Wirtschaftswissenschaften (30)
- Fachbereich Luft- und Raumfahrttechnik (26)
- Fachbereich Maschinenbau und Mechatronik (19)
- Fachbereich Energietechnik (16)
- INB - Institut für Nano- und Biotechnologien (15)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (11)
- Institut fuer Angewandte Polymerchemie (5)
- Nowum-Energy (5)
- Solar-Institut Jülich (5)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (5)
- ECSM European Center for Sustainable Mobility (4)
- Fachbereich Architektur (3)
- IBB - Institut für Baustoffe und Baukonstruktionen (2)
- Fachbereich Gestaltung (1)
The structure of the female pelvic floor (PF) is an inter-related system of bony pelvis,muscles, pelvic organs, fascias, ligaments, and nerves with multiple functions. Mechanically, thepelvic organ support system are of two types: (I) supporting system of the levator ani (LA) muscle,and (II) the suspension system of the endopelvic fascia condensation [1], [2]. Significantdenervation injury to the pelvic musculature, depolimerization of the collagen fibrils of the softvaginal hammock, cervical ring and ligaments during pregnancy and vaginal delivery weakens thenormal functions of the pelvic floor. Pelvic organ prolapse, incontinence, sexual dysfunction aresome of the dysfunctions which increases progressively with age and menopause due toweakened support system according to the Integral theory [3]. An improved 3D finite elementmodel of the female pelvic floor as shown in Fig. 1 is constructed that: (I) considers the realisticsupport of the organs to the pelvic side walls, (II) employs the improvement of our previous FEmodel [4], [5] along with the patient based geometries, (III) incorporates the realistic anatomy andboundary conditions of the endopelvic (pubocervical and rectovaginal) fascia, and (IV) considersvarying stiffness of the endopelvic fascia in the craniocaudal direction [3]. Several computationsare carried out on the presented computational model with healthy and damaged supportingtissues, and comparisons are made to understand the physiopathology of the female PF disorders.
The human arm consists of the humerus (upper arm), the medial ulna and the lateral radius (forearm). The joint between the humerus and the ulna is called humeroulnar joint and the joint between the humerus and the radius is called humeroradial joint. Lateral and medial collateral ligaments stabilize the elbow. Statistically, 2.5 out of 10,000 people suffer from radial head fractures [1]. In these fractures the cartilage is often affected. Caused by the injured cartilage, degenerative diseases like posttraumatic arthrosis may occur. The resulting pain and reduced range of motion have an impact on the patient’s quality of life. Until now, there has not been a treatment which allows typical loads in daily life activities and offers good long-term results. A new surgical approach was developed with the motivation to reduce the progress of the posttraumatic arthrosis. Here, the radius is shortened by 3 mm in the proximal part [2]. By this means, the load of the radius is intended to be reduced due to a load shift to the ulna. Since the radius is the most important stabilizer of the elbow it has to be confirmed that the stability is not affected. In the first test (Fig. 1 left), pressure distributions within the humeroulnar and humeroradial joints a native and a shortened radius were measured using resistive pressure sensors (I5076 and I5027, Tekscan, USA). The humerus was loaded axially in a tension testing machine (Z010, Zwick Roell, Germany) in 50 N steps up to 400 N. From the humerus the load is transmitted through both the radius and the ulna into the hand which is fixed on the ground. In the second test (Fig. 1 right), the joint stability was investigated using a digital image correlation system to measure the displacement of the ulna. Here, the humerus is fixed with a desired flexion angle and the unconstrained forearm lies on the ground. A rope connects the load actuator with a hook fixed in the ulna. A guide roller is used so that the rope pulls the ulna horizontally when a tensile load is applied. This creates a moment about the elbow joint with a maximum value of 7.5 Nm. Measurements were performed with varying flexion angles (0°, 30°, 60°, 90°, 120°). For both tests and each measurement, seven specimens were used. Student ́s t-test was employed to determine whether the mean values of the measurements in native specimen and operated specimens differ significantly.
Insolvenzanfechtung: Keine Gläubigerbenachteiligung bei Ablösezahlung gegen Forderungsverzicht
(2016)
Schwerpunkt einer vorinsolvenzlichen Sanierung ist i.d.R., dass einzelne Gläubiger gegen Teilzahlungen auf ihre Forderungen verzichten und somit dem Unternehmen den notwendigen finanziellen Freiraum für einen Turnaround geben. Die Motivation der Gläubiger für einen Verzicht ist dabei auch die Überlegung, dass eine quotale Befriedigung im Rahmen eines Insolvenzverfahrens oft wesentlich geringer ausfallen würde als die durch den Vergleich realisierte Teilzahlung. Das Risiko, im Falle der Insolvenz eine Teilzahlung im Rahmen der Insolvenzanfechtung aber wieder zurückgewähren zu müssen, macht einen Forderungsverzicht weniger attraktiv. Mit Urteil vom 28.01.2016 hat der BGH nun entschieden, dass eine Insolvenzanfechtung mangels Gläubigerbenachteiligung ausscheidet, wenn der in der Teilzahlung liegende Vermögensverlust durch den damit verbundenen Verzicht auf die Restforderung voll ausgeglichen wird. Im Folgenden wird untersucht, ob dieses Urteil als Blaupause für eine anfechtungsfeste Restrukturierung einzelner Verbindlichkeiten dienen kann.
Optimization of the immobilization of bacterial spores on glass substrates with organosilanes
(2016)
Spores can be immobilized on biosensors to function as sensitive recognition elements. However, the immobilization can affect the sensitivity and reproducibility of the sensor signal. In this work, three different immobilization strategies with organosilanes were optimized and characterized to immobilize Bacillus atrophaeus spores on glass substrates. Five different silanization parameters were investigated: nature of the solvent, concentration of the silane, silanization time, curing process, and silanization temperature. The resulting silane layers were resistant to a buffer solution (e.g., Ringer solution) with a polysorbate (e.g., Tween®80) and sonication.
A multi-spot light-addressable potentiometric sensor (LAPS), which belongs to the family of semiconductor field-effect devices, was applied for label-free detection of double-stranded deoxyribonucleic acid (dsDNA) molecules by their intrinsic molecular charge. To reduce the distance between the DNA charge and sensor surface and thus, to enhance the electrostatic coupling between the dsDNA molecules and the LAPS, the negatively charged dsDNA molecules were electrostatically adsorbed onto the gate surface of the LAPS covered with a positively charged weak polyelectrolyte layer of PAH (poly(allylamine hydrochloride)). The surface potential changes in each spot of the LAPS, induced by the layer-by-layer adsorption of a PAH/dsDNA bilayer, were recorded by means of photocurrent-voltage and constant-photocurrent measurements. In addition, the surface morphology of the gate surface before and after consecutive electrostatic adsorption of PAH and dsDNA layers was studied by atomic force microscopy measurements. Moreover, fluorescence microscopy was used to verify the successful adsorption of dsDNA molecules onto the PAH-modified LAPS surface. A high sensor signal of 25 mV was registered after adsorption of 10 nM dsDNA molecules. The lower detection limit is down to 0.1 nM dsDNA. The obtained results demonstrate that the PAH-modified LAPS device provides a convenient and rapid platform for the direct label-free electrical detection of in-solution hybridized dsDNA molecules.