Refine
Year of publication
- 2016 (251) (remove)
Document Type
- Article (113)
- Conference Proceeding (71)
- Part of a Book (27)
- Book (22)
- Other (9)
- Report (5)
- Doctoral Thesis (3)
- Patent (1)
Has Fulltext
- no (251) (remove)
Keywords
- Technical Operations Research (2)
- Additive Manufacturing (1)
- Annulus Fibrosus (1)
- Assessment (1)
- Asymptotic efficiency (1)
- Bacillus atrophaeus (1)
- Balance (1)
- Balanced hypergraph (1)
- Brandfall (1)
- Building Systems (1)
- Business Simulations (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- CellDrum (1)
- Censored data (1)
- Co-managed care (1)
- Collaborative robot (1)
- Computational biomechanics (1)
- Controller Parameter (1)
- DNA biosensor (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (51)
- Fachbereich Chemie und Biotechnologie (36)
- Fachbereich Bauingenieurwesen (35)
- IfB - Institut für Bioengineering (33)
- Fachbereich Elektrotechnik und Informationstechnik (32)
- Fachbereich Wirtschaftswissenschaften (30)
- Fachbereich Luft- und Raumfahrttechnik (26)
- Fachbereich Maschinenbau und Mechatronik (19)
- Fachbereich Energietechnik (16)
- INB - Institut für Nano- und Biotechnologien (15)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (11)
- Institut fuer Angewandte Polymerchemie (5)
- Nowum-Energy (5)
- Solar-Institut Jülich (5)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (5)
- ECSM European Center for Sustainable Mobility (4)
- Fachbereich Architektur (3)
- IBB - Institut für Baustoffe und Baukonstruktionen (2)
- Fachbereich Gestaltung (1)
Für das Auftreten extremer Wetterereignisse werden für Kernkraftwerke Eintrittshäufigkeiten für nicht mehr beherrschbare Zustände von unter 10⁻⁴/a gefordert. Dies gilt auch für die Einwirkung von Blitzeinschlägen. Die bisherige Nachweisführung zu Blitz- und Überspannungsschutz eines KKW in Deutschland ist deterministisch. In diesem Bericht werden das Vorgehen für einen entsprechenden Nachweis für leittechnische Einrichtungen der Sicherheitstechnik von KKW, der zur geforderten Zielgröße der Eintrittshäufigkeit führt. Die Ergebnisse werden zusammenfassend bewertet.
The production and assembly of customized products increases the demand for flexible automation systems. One approach is to remove the safety fences that separate human and industrial robot to combine their skills. This collaboration possesses a certain risk for the human co-worker, leading to numerous safety concepts to protect him. The human needs to be monitored and tracked by a safety system using different sensors. The proposed system consists of a RGBD camera for surveillance of the common working area, an array of optical distance sensors to compensate shadowing effects of the RGBD camera and a laser range finder to detect the co-worker when approaching the work cell. The software for collision detection, path planning, robot control and predicting the behaviour of the co-worker is based on the Robot Operating System (ROS). A first prototype of the work cell shows that with advanced algorithms from the field of mobile robotics a very flexible safety concept can be realized: the robot not simply stops its movement when detecting a collision, but plans and executes an alternative path around the obstacle.
The human arm consists of the humerus (upper arm), the medial ulna and the lateral radius (forearm). The joint between the humerus and the ulna is called humeroulnar joint and the joint between the humerus and the radius is called humeroradial joint. Lateral and medial collateral ligaments stabilize the elbow. Statistically, 2.5 out of 10,000 people suffer from radial head fractures [1]. In these fractures the cartilage is often affected. Caused by the injured cartilage, degenerative diseases like posttraumatic arthrosis may occur. The resulting pain and reduced range of motion have an impact on the patient’s quality of life. Until now, there has not been a treatment which allows typical loads in daily life activities and offers good long-term results. A new surgical approach was developed with the motivation to reduce the progress of the posttraumatic arthrosis. Here, the radius is shortened by 3 mm in the proximal part [2]. By this means, the load of the radius is intended to be reduced due to a load shift to the ulna. Since the radius is the most important stabilizer of the elbow it has to be confirmed that the stability is not affected. In the first test (Fig. 1 left), pressure distributions within the humeroulnar and humeroradial joints a native and a shortened radius were measured using resistive pressure sensors (I5076 and I5027, Tekscan, USA). The humerus was loaded axially in a tension testing machine (Z010, Zwick Roell, Germany) in 50 N steps up to 400 N. From the humerus the load is transmitted through both the radius and the ulna into the hand which is fixed on the ground. In the second test (Fig. 1 right), the joint stability was investigated using a digital image correlation system to measure the displacement of the ulna. Here, the humerus is fixed with a desired flexion angle and the unconstrained forearm lies on the ground. A rope connects the load actuator with a hook fixed in the ulna. A guide roller is used so that the rope pulls the ulna horizontally when a tensile load is applied. This creates a moment about the elbow joint with a maximum value of 7.5 Nm. Measurements were performed with varying flexion angles (0°, 30°, 60°, 90°, 120°). For both tests and each measurement, seven specimens were used. Student ́s t-test was employed to determine whether the mean values of the measurements in native specimen and operated specimens differ significantly.