Conference Proceeding
Refine
Year of publication
- 2020 (55) (remove)
Document Type
- Conference Proceeding (55) (remove)
Keywords
- Adjacent buildings (2)
- Historical centres (2)
- MINLP (2)
- Shake table test (2)
- Stone masonry (2)
- Acceptance (1)
- Additive manufacturing (1)
- Blind prediction competition (1)
- Bumblebees (1)
- Capacity Building Higher Education (1)
- Capacity Curve (1)
- Case study (1)
- Cooling system (1)
- Digitalization (1)
- Efficiency optimization (1)
- Engineering optimisation (1)
- Engineering optimization (1)
- Ethics (1)
- European Framework and South East Asia (1)
- Experimental validation (1)
Institute
- Fachbereich Energietechnik (16)
- Fachbereich Elektrotechnik und Informationstechnik (13)
- Fachbereich Luft- und Raumfahrttechnik (11)
- ECSM European Center for Sustainable Mobility (8)
- Solar-Institut Jülich (8)
- Fachbereich Maschinenbau und Mechatronik (6)
- Fachbereich Medizintechnik und Technomathematik (4)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (3)
- Fachbereich Bauingenieurwesen (2)
- Fachbereich Wirtschaftswissenschaften (2)
- IaAM - Institut für angewandte Automation und Mechatronik (2)
- IfB - Institut für Bioengineering (2)
- Kommission für Forschung und Entwicklung (1)
- Nowum-Energy (1)
Seismic behavior of an existing unreinforced masonry building built pre-modern code, located in the City of Ohrid, Republic of North Macedonia has been investigated in this paper. The analyzed school building is selected as an archetype in an ongoing project named “Seismic vulnerability assessment of existing masonry structures in Republic of North Macedonia (SeismoWall)”. Two independent segments were included in this research: Seismic hazard assessment by creating a cite specific response spectra and Seismic vulnerability definition by creating a region - specific series of vulnerability curves for the chosen building topology. A reliable Seismic Hazard Assessment for a selected region is a crucial point for performing a seismic risk analysis of a characteristic building class. In that manner, a scenario – based method that incorporates together the knowledge of tectonic style of the considered region, the active fault characterization, the earth crust model and the historical seismicity named Neo Deterministic approach is used for calculation of the response spectra for the location of the building. Variations of the rupturing process are taken into account in the nucleation point of the rupture, in the rupture velocity pattern and in the istribution of the slip on the fault. The results obtained from the multiple scenarios are obtained as an envelope of the response spectra computed for the cite using the procedure Maximum Credible Seismic Input (MCSI). Capacity of the selected building has been determined by using nonlinear static analysis. MINEA software (SDA Engineering) was used for verification of the structural safety of the chosen unreinforced masonry structure. In the process of optimization of the number of samples, computational cost required in a Monte Carlo simulation is significantly reduced since the simulation is performed on a polynomial response surface function for prediction of the structural response. Performance point, found as the intersection of the capacity of the building and the spectra used, is chosen as a response parameter. Five levels of damage limit states based on the capacity curve of the building are defined in dependency on the yield displacement and the maximum displacement. Maximum likelihood estimation procedure is utilized in the process of vulnerability curves determination. As a result, region specific series of vulnerability curves for the chosen type of masonry structures are defined. The obtained probabilities of exceedance a specific damage states as a result from vulnerability curves are compared with the observed damages happened after the earthquake in July 2017 in the City of Ohrid, North Macedonia.
Successful optimization requires an appropriate model of the system under consideration. When selecting a suitable level of detail, one has to consider solution quality as well as the computational and implementation effort. In this paper, we present a MINLP for a pumping system for the drinking water supply of high-rise buildings. We investigate the influence of the granularity of the underlying physical models on the solution quality. Therefore, we model the system with a varying level of detail regarding the friction losses, and conduct an experimental validation of our model on a modular test rig. Furthermore, we investigate the computational effort and show that it can be reduced by the integration of domain-specific knowledge.
A research framework for human aspects in the internet of production: an intra-company perspective
(2020)
Digitalization in the production sector aims at transferring concepts and methods from the Internet of Things (IoT) to the industry and is, as a result, currently reshaping the production area. Besides technological progress, changes in work processes and organization are relevant for a successful implementation of the “Internet of Production” (IoP). Focusing on the labor organization and organizational procedures emphasizes to consider intra-company factors such as (user) acceptance, ethical issues, and ergonomics in the context of IoP approaches. In the scope of this paper, a research approach is presented that considers these aspects from an intra-company perspective by conducting studies on the shop floor, control level and management level of companies in the production area. Focused on four central dimensions—governance, organization, capabilities, and interfaces—this contribution presents a research framework that is focused on a systematic integration and consideration of human aspects in the realization of the IoP.