Refine
Year of publication
- 2024 (12)
- 2023 (21)
- 2022 (38)
- 2021 (42)
- 2020 (50)
- 2019 (62)
- 2018 (58)
- 2017 (60)
- 2016 (41)
- 2015 (59)
- 2014 (52)
- 2013 (53)
- 2012 (58)
- 2011 (65)
- 2010 (57)
- 2009 (66)
- 2008 (50)
- 2007 (40)
- 2006 (37)
- 2005 (36)
- 2004 (68)
- 2003 (38)
- 2002 (44)
- 2001 (46)
- 2000 (47)
- 1999 (29)
- 1998 (24)
- 1997 (22)
- 1996 (21)
- 1995 (16)
- 1994 (11)
- 1993 (16)
- 1992 (7)
- 1991 (5)
- 1990 (11)
- 1989 (10)
- 1988 (16)
- 1987 (6)
- 1986 (2)
- 1985 (2)
- 1984 (1)
- 1983 (2)
- 1982 (20)
- 1981 (13)
- 1980 (27)
- 1979 (18)
- 1978 (26)
- 1977 (13)
- 1976 (12)
- 1975 (9)
- 1974 (2)
- 1973 (1)
- 1972 (2)
- 1968 (1)
Document Type
- Article (1299)
- Conference Proceeding (131)
- Book (43)
- Part of a Book (40)
- Doctoral Thesis (18)
- Other (5)
- Patent (4)
- Preprint (3)
- Habilitation (1)
- Talk (1)
Language
- English (1545) (remove)
Has Fulltext
- no (1545) (remove)
Keywords
- LAPS (4)
- Natural language processing (4)
- CellDrum (3)
- Field-effect sensor (3)
- Light-addressable potentiometric sensor (3)
- Paired sample (3)
- hydrogen peroxide (3)
- Bacillus atrophaeus (2)
- Biocomposites (2)
- Clustering (2)
- Empirical process (2)
- Force (2)
- Goodness-of-fit test (2)
- Incomplete data (2)
- Independence test (2)
- Information extraction (2)
- Iterative learning control (2)
- Limit analysis (2)
- Machine learning (2)
- Natural fibres (2)
Institute
- Fachbereich Medizintechnik und Technomathematik (1545) (remove)
Based on the European Space Agency (ESA) Science in Space Environment (SciSpacE) community White Paper “Human Physiology – Musculoskeletal system”, this perspective highlights unmet needs and suggests new avenues for future studies in musculoskeletal research to enable crewed exploration missions. The musculoskeletal system is essential for sustaining physical function and energy metabolism, and the maintenance of health during exploration missions, and consequently mission success, will be tightly linked to musculoskeletal function. Data collection from current space missions from pre-, during-, and post-flight periods would provide important information to understand and ultimately offset musculoskeletal alterations during long-term spaceflight. In addition, understanding the kinetics of the different components of the musculoskeletal system in parallel with a detailed description of the molecular mechanisms driving these alterations appears to be the best approach to address potential musculoskeletal problems that future exploratory-mission crew will face. These research efforts should be accompanied by technical advances in molecular and phenotypic monitoring tools to provide in-flight real-time feedback.
A new in vitro tool to investigate cardiac contractility under physiological mechanical conditions
(2019)
Analysis of the long-term effect of the MBST® nuclear magnetic resonance therapy on gonarthrosis
(2016)
Introduction
In regard of surgical training, the reproducible simulation of life-like proximal humerus fractures in human cadaveric specimens is desirable. The aim of the present study was to develop a technique that allows simulation of realistic proximal humerus fractures and to analyse the influence of rotator cuff preload on the generated lesions in regards of fracture configuration.
Materials and methods
Ten cadaveric specimens (6 left, 4 right) were fractured using a custom-made drop-test bench, in two groups. Five specimens were fractured without rotator cuff preload, while the other five were fractured with the tendons of the rotator cuff preloaded with 2 kg each. The humeral shaft and the shortened scapula were potted. The humerus was positioned at 90° of abduction and 10° of internal rotation to simulate a fall on the elevated arm. In two specimens of each group, the emergence of the fractures was documented with high-speed video imaging. Pre-fracture radiographs were taken to evaluate the deltoid-tuberosity index as a measure of bone density. Post-fracture X-rays and CT scans were performed to define the exact fracture configurations. Neer’s classification was used to analyse the fractures.
Results
In all ten cadaveric specimens life-like proximal humerus fractures were achieved. Two III-part and three IV-part fractures resulted in each group. The preloading of the rotator cuff muscles had no further influence on the fracture configuration. High-speed videos of the fracture simulation revealed identical fracture mechanisms for both groups. We observed a two-step fracture mechanism, with initial impaction of the head segment against the glenoid followed by fracturing of the head and the tuberosities and then with further impaction of the shaft against the acromion, which lead to separation of the tuberosities.
Conclusion
A high energetic axial impulse can reliably induce realistic proximal humerus fractures in cadaveric specimens. The preload of the rotator cuff muscles had no influence on initial fracture configuration. Therefore, fracture simulation in the proximal humerus is less elaborate. Using the presented technique, pre-fractured specimens are available for real-life surgical education.
It is well known that the degradation environment can strongly influence the biodegradability and kinetics of biodegradation processes of polymers. Therefore, besides the monitoring of the degradation process, it is also necessary to control the medium in which the degradation takes place. In this work, a micromachined multi-parameter sensor chip for the control of the polymer-degradation medium has been developed. The chip combines a capacitive field-effect pH sensor, a four-electrode electrolyte-conductivity sensor and a thin-film Pt-temperature sensor. The results of characterization of individual sensors are presented. In addition, the multi-parameter sensor chip together with an impedimetric polymer-degradation sensor was simultaneously characterized in degradation solutions with different pH and electrolyte conductivity. The obtained results demonstrate the feasibility of the multi-parameter sensor chip for the control of the polymer-degradation medium.