Article
Refine
Year of publication
Document Type
- Article (3149) (remove)
Language
- English (3149) (remove)
Has Fulltext
- no (3149) (remove)
Keywords
- avalanche (5)
- Earthquake (4)
- LAPS (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- CellDrum (3)
- Heparin (3)
- capacitive field-effect sensor (3)
- hydrogen peroxide (3)
- magnetic nanoparticles (3)
- snow (3)
- tobacco mosaic virus (TMV) (3)
- Bacillus atrophaeus (2)
- Chemometrics (2)
- Drinfeld modules (2)
- Empirical process (2)
- Field-effect sensor (2)
- Goodness-of-fit test (2)
- Hot S-parameter (2)
- IR spectroscopy (2)
- Independence test (2)
- Light-addressable potentiometric sensor (2)
- MINLP (2)
- NMR spectroscopy (2)
- Paired sample (2)
- Parametric bootstrap (2)
- Principal component analysis (2)
- Pump System (2)
- Raman spectroscopy (2)
- Standardization (2)
- Stiffness (2)
- Transcendence (2)
- additive manufacturing (2)
- bacterial cellulose (2)
- biosensors (2)
- constructive alignment (2)
- damage (2)
- energy efficiency (2)
- examination (2)
- fused filament fabrication (2)
- gold nanoparticles (2)
- harmonic radar (2)
- immobilization (2)
- impedance spectroscopy (2)
- light-addressable potentiometric sensor (2)
- likelihood ratio test (2)
- locomotion (2)
- long-term retention (2)
- multimodal (2)
- muscle fascicle behavior (2)
- not identically distributed (2)
- practical learning (2)
- prebiotic (2)
- rapid tooling (2)
- t-modules (2)
- ultrasound (2)
- ultrasound imaging (2)
- (Bio)degradation (1)
- 1P hub loads (1)
- 3-D printing (1)
- 3D nonlinear finite element model (1)
- 802.15.4 (1)
- Acceleration (1)
- Achilles tendon (1)
- Adaptive control (1)
- Additive Manufacturing (1)
- Aeroelasticity (1)
- Afterload (1)
- Ageing (1)
- Alginate beads (1)
- AlterG (1)
- Alzheimer's disease (1)
- Anastomotic leakage (1)
- Anatomy (1)
- Annulus Fibrosus (1)
- Antarctic Glaciology (1)
- Antibias (1)
- Architectural gear ratio (1)
- Artificial intelligence (1)
- Assembly (1)
- Assistive technology (1)
- Asymptotic efficiency (1)
- Authenticity (1)
- Autolysis (1)
- Automated driving (1)
- Automatic control (1)
- Automotive application (1)
- Avalanche (1)
- Bacillus atrophaeus spores (1)
- Bacillus sp (1)
- Balance (1)
- Balanced hypergraph (1)
- Bank-issued Warrants (1)
- Behaviour factor q (1)
- Benchmark (1)
- Biocomposites (1)
- Biomass (1)
- Biomechanical simulation (1)
- Biosolubilization (1)
- Bloom’s Taxonomy (1)
- Bluetooth (1)
- Booster Station (1)
- Booster Stations (1)
- Bootstrap (1)
- Bootstrapping (1)
- Borehole heat exchanger (1)
- Bragg peak (1)
- Brake set-up (1)
- Braking curves (1)
- Brownian Pillow (1)
- Buffering Capacity (1)
- CAV (1)
- CNOT (1)
- CO2 emission reduction targets (1)
- CRISPR/Cas9 (1)
- Calorimetric gas sensor (1)
- Capacitive field-effect (1)
- Capacitive model (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- Cardiovascular MRI (1)
- Categorial variable (1)
- Cell permeability (1)
- Cellular force (1)
- Cementoblast (1)
- Censored data (1)
- Chance Constraint (1)
- Chemical images (1)
- Chemical imaging sensor (1)
- Chemical sensor (1)
- Circuit simulation (1)
- Circular Dichroism (1)
- Civil engineering (1)
- Clinical decision support systems (1)
- Co-managed care (1)
- Collective risk model (1)
- Commercial Vehicle (1)
- Common Rail Injection System (1)
- Competence Developing Games (1)
- Competitiveness (1)
- Complex System (1)
- Complex-valued eigenvalues (1)
- Compliance (1)
- Compression (1)
- Computational biomechanics (1)
- Concomitant (1)
- Conductive Boundary Condition (1)
- Consensus (1)
- Constitutive model (1)
- Contractile tension (1)
- Contractility (1)
- Cost function (1)
- Coverage probability (1)
- Cramér-von-Mises statistic (1)
- Cramér-von-Mises test (1)
- Cross border adjustment mechanism (1)
- Crude heparin (1)
- Crámer–von-Mises distance (1)
- Cyclotron production (1)
- C–V method (1)
- DLR-ESTEC GOSSAMER roadmap for solar sailing (1)
- DNA biosensor (1)
- DNA hybridization (1)
- DPA (dipicolinic acid) (1)
- Damage mechanics theory (1)
- Decomposition (1)
- Decoupling (1)
- Dehydrogenase (1)
- Detergent protease (1)
- Deuterated solvents (1)
- Deuterium NMR (1)
- Diaphorase (1)
- Diesel Engine (1)
- Disc Degeneration (1)
- Discontinuous fractures (1)
- Discourse ethics (1)
- Discrete Optimization (1)
- Disposition Effect (1)
- Distributed Control Systems, (1)
- Diversity Management (1)
- Driver assistance system (1)
- Driving cycle recognition (1)
- Drug simulation (1)
- Dry-low-NOx (DLN) combustion (1)
- Duality (1)
- Dynamic simulation (1)
- E-Mobility (1)
- ECMS (1)
- EIS capacitive sensor (1)
- ES-FEM (1)
- Effective modal mass (1)
- Eigenvalue trajectories (1)
- Elderly (1)
- Electrolyte–insulator–semiconductor (1)
- Electromagnetism (1)
- Electromechanical modeling (1)
- Elemental (1)
- Emilia-Romagna earthquake (1)
- Empirical consequence curves (1)
- Empirical fragility functions (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Endothelial dysfunction (1)
- Energy management strategies (1)
- Energy-intensive industry (1)
- Engineering Application (1)
- Engineering Habitus (1)
- Enzymatic biosensor (1)
- Enzyme coverage (1)
- Enzyme logic gate (1)
- Equivalence test (1)
- Esophageal Doppler monitor (1)
- European Transient Cycle (1)
- Eutectic Silver Copper alloy (1)
- Experimental validation (1)
- Explainability (1)
- External knee adduction moments (1)
- Extracellular enzymes (1)
- Extraterrestrial Glaciology (1)
- FS-FEM (1)
- Fall prevention (1)
- Feature selection (1)
- Field effect (1)
- Field-effect biosensor (1)
- Finite differences (1)
- Finite element analysis (1)
- Finite element modelling (1)
- Finland (1)
- Floor prices (1)
- Flutter (1)
- Force (1)
- Forces (1)
- Fracture classification (1)
- Fracture configuration (1)
- Fracture simulation (1)
- Frame structure (1)
- Freeze–thaw process (1)
- Freight rail (1)
- Frequency adaption (1)
- Frequency mixing magnetic detection (1)
- Functional Delta Method (1)
- Furnace (1)
- Fusion (1)
- GOSSAMER-1 (1)
- Ga-68 (1)
- Game-based learning (1)
- Gamification (1)
- Gamma distribution (1)
- Genetic algorithm (1)
- Germany (1)
- Glaciological instruments and methods (1)
- Glaucoma (1)
- Goodness-of-fit tests for uniformity (1)
- Ground-level falls (1)
- Hadamard differentiability (1)
- Haemodialysis (1)
- Hall’s Theorem (1)
- Handbike (1)
- Hazard assessment (1)
- Heart tissue culture (1)
- Heat transport (1)
- Heterostructure (1)
- High hydrogen combustion (1)
- Higher derivations (1)
- Hodgkin–Huxley models (1)
- Hoeffding-Blum-Kiefer-Rosenblatt independence test (1)
- Homogenization (1)
- Hotelling’s T² test (1)
- Human factors (1)
- Human-Computer interaction (1)
- Hydrogen combustion (1)
- Hydrogen gas turbine (1)
- Hydrogen peroxide (1)
- Hyperdifferentials (1)
- Hypergraph (1)
- Hypersecretion (1)
- INSYSME (1)
- IP-based networks (1)
- IR (1)
- IT security education (1)
- Illustration (1)
- Image Reconstruction (1)
- Imaging (1)
- Impedance spectroscopy (1)
- In-plane performance, isolation (1)
- Incomplete data (1)
- Individual Investors (1)
- Induced pluripotent stem cells (1)
- Industrial Automation Technology, (1)
- Infill wall design (1)
- Inorganic ions (1)
- Inotropic compounds (1)
- Instructional design (1)
- Integrated empirical distribution (survival) function (1)
- Interior transmission problem (1)
- Interstellar objects (1)
- Intervertebral Disc (1)
- Intradiscal Pressure (1)
- Inverse Scattering (1)
- Inverse dynamic problem (1)
- Inverse kinematic problem (1)
- Ion channels (1)
- Ions (1)
- Iterative learning control (1)
- Justice (1)
- Keyword analysis (1)
- Kinetic energy (1)
- Koenig’s Theorem (1)
- LPS (1)
- Lab-on-Chip (1)
- Label-free detection (1)
- Lactobacillus rhamnosus GG (1)
- Landslide tsunamis (1)
- Langevin theory (1)
- Large scale tests (1)
- Latvia (1)
- Layer-by-layer adsorption (1)
- LbL films (1)
- Left ventriular function (1)
- Level system (1)
- Lidar (1)
- Light-addressable Potentiometric Sensor (1)
- Linear discriminant analysis (1)
- Linear elastic analysis (1)
- Lipopolysaccharide (1)
- Liver (1)
- Long COVID (1)
- Low-field NMR (1)
- MILP (1)
- MOS (1)
- MR-stethoscope (1)
- MUT measurement; scanner (1)
- Machine learning (1)
- Magnetic field strength (1)
- Magnetic nanoparticles (1)
- Magnetic resonance imaging (MRI) (1)
- Manipulated variables (1)
- Manufacturer (1)
- Marginal homogeneity test (1)
- Marker-free mutagenesis (1)
- Masonry infill (1)
- Masonry partition walls (1)
- Matching (1)
- Measurement models (1)
- Measurement uncertainty (1)
- Mechanotransduction (1)
- Medical AI (1)
- Medical radionuclide production (1)
- Metal contaminants (1)
- Metascintillator (1)
- Microcirculation (1)
- Microfluidic solvent extraction (1)
- Micromagnetic simulation (1)
- Micromix combustion (1)
- Mild cognitive impairment (1)
- Missions (1)
- Mobility (1)
- Mobility tests (1)
- Mobility transition (1)
- Mode converter (1)
- Modelica (1)
- Modeling (1)
- Modelling (1)
- Modern constructions (1)
- Molecular modelling (1)
- Molecular weight determination (1)
- Molten salt receiver system (1)
- Molten salt solar tower (1)
- Monte Carlo Tree Search (1)
- Morphing (1)
- Multi-criteria decision analysis (1)
- Multi-objective optimization (1)
- Multi-sample problem (1)
- Multi-storey (1)
- Multianalyte detection (1)
- Multiple TOF kernels (1)
- Muscle (1)
- Muscle Fascicle (1)
- Muscle Force (1)
- Musculoskeletal model (1)
- Musculoskeletal system (1)
- Myocardial infarction and cardiac death (1)
- NGN (1)
- NMR (1)
- NMR exchange relaxometry (1)
- NONOate (1)
- Natural fibres (1)
- Natural frequency (1)
- Negative Feedback Trading (1)
- Negative impedance convertor (1)
- Neural Network (1)
- Nitric Oxide (1)
- Nitric Oxide Donor (1)
- Non-parallel fissures (1)
- Nonequilibrium dynamics (1)
- Nonlinear Dynamics (1)
- Normative standards (1)
- Nucleus Pulposus (1)
- Numerical inversion of Laplace transforms (1)
- Numerical linear algebra (1)
- Numerical modelling (1)
- O2 plasma (1)
- Ocular blood flow (1)
- Organic light-emitting diode display (1)
- Organizational Culture (1)
- Out-of-plane capacity (1)
- Overland flow (1)
- P2G (1)
- PBEE (1)
- PIV (1)
- PLS-regression (1)
- PROFINET (1)
- Paralympic sport (1)
- Path planning (1)
- Penicillin (1)
- Periods (1)
- Pharmacology (1)
- Physiology (1)
- Piping (1)
- Plasma (1)
- Plasma diagnostics (1)
- Poly(allylamine hydrochloride) (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Polymer-matrix composites (1)
- Porositat (1)
- Post-COVID-19 syndrome (1)
- Powertrain (1)
- Precast buildings (1)
- Predictive battery discharge (1)
- Preference assessment (1)
- Probability distribution mapping (1)
- Process virtualization (1)
- Product bundling (1)
- Product-integration (1)
- Propeller whirl flutter (1)
- Proper Orthogonal Decomposition (1)
- Proximal humerus fracture (1)
- Pulsations (1)
- Pumping systems (1)
- Q-criterion (1)
- Quality control (1)
- Quantum chemistry (1)
- RAMMS (1)
- RVA (1)
- Radar (1)
- Real-time monitoring (1)
- Recombinant activated protein C (1)
- Regionalization (1)
- Rehabilitation Technology and Prosthetics (1)
- Rehabilitation engineering (1)
- Reinforced concrete frame (1)
- Requirements prioritization (1)
- Requirements relations (1)
- Resampling test (1)
- Resolvent Operator (1)
- Resonance-mode measurement (1)
- Response Surface Method (1)
- Retinal vessel analysis (1)
- Retinal vessels (1)
- Robotic rehabilitation (1)
- Rotary encoder (1)
- Rotator cuff (1)
- Running (1)
- S-FEM (1)
- SFCW (1)
- SLM (1)
- SOA (1)
- ScaLAPACK (1)
- Seismic design (1)
- Seismic loading (1)
- Selective Catalytic Reduction (1)
- Self-driving (1)
- Semi-parametric random censorship model (1)
- Septic cardiomyopathy (1)
- Services (1)
- Shoulder (1)
- Shunting (1)
- Simulation (1)
- Simultaneous determination (1)
- Slab deflection (1)
- Small spacecraft (1)
- Snow (1)
- Sn₃O₄ (1)
- Soft independent modeling of class analogy (1)
- Solar sail (1)
- Solitary waves (1)
- Spleen (1)
- Steel industry (1)
- Stenotrophomonas maltophilia (1)
- Sterilisation process (1)
- Stochastic Programming (1)
- Stress concentrations (1)
- Structural design (1)
- Subclacial exploration (1)
- Subglacial lakes (1)
- Surgical Navigation and Robotics (1)
- Surgical staplers (1)
- Survival analysis (1)
- Suspension bridge (1)
- TMV adsorption (1)
- TOF PET (1)
- Tank (1)
- Ta₂O₅ gate (1)
- Technical Operations Research (1)
- Technical Operations Research (TOR) (1)
- Telecommunication (1)
- Tendon Rupture (1)
- Tendon properties (1)
- Tension (1)
- Thin shell finite elements (1)
- Tinetti test (1)
- Tool support (1)
- Trading Behavior (1)
- Trajectories (1)
- Transformation (1)
- Transient flux distribution (1)
- Transmission Eigenvalues (1)
- Two-phase modelling (1)
- Typographie (1)
- USP (1)
- Uncertainty (1)
- Uniaxial compression test (1)
- Unreinforced masonry buildings (1)
- Unsteady aerodynamics (1)
- Uracil-phosphoribosyltransferase (1)
- User study (1)
- VOF (1)
- Vapnik–Čhervonenkis class (1)
- Variable height stapler design (1)
- Vascular response (1)
- Vasomotions (1)
- Velocity (1)
- Vertex cover (1)
- Virtual reality (1)
- Visual field asymmetry (1)
- Volterra integral equation (1)
- Volume of confidence regions (1)
- Volume status (1)
- Water Distribution (1)
- Water Supply Networks (1)
- Wiegand sensor (1)
- Wireless Networks (1)
- XOR (1)
- achilles tendon (1)
- actin cytoskeleton (1)
- actuator-sensor system (1)
- adaptive systems (1)
- adipose-derived stromal cells (ASCs) (1)
- adsorption (1)
- agility (1)
- allocation (1)
- aminooctanethiol (1)
- anaesthetic complications (1)
- anammox (1)
- anisotropy (1)
- annealing (1)
- aortic perfusion (1)
- artificial intelligence (1)
- artificial olfactory image (1)
- aseptic parameters (1)
- aspergillus (1)
- assistance system (1)
- asymptotic relative efficiency (1)
- automated vehicles (1)
- availability (1)
- barium strontium titanate (1)
- batteries and fuel cells (1)
- bi-enzyme biosensor (1)
- biaxial tensile experiment (1)
- bioavailability (1)
- biodegradable polymers (1)
- biofilms (1)
- biological dosimeter (1)
- biomechanics (1)
- biomethane (1)
- biopotential electrodes (1)
- biosensor (1)
- body imaging at 7 T MRI (1)
- body limbs (1)
- bootstrap (1)
- borefields (1)
- borehole disposal (1)
- brachytherapy (1)
- bubble column (1)
- building energy modelling (1)
- building energy simulation (1)
- calorimetric gas sensor (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- capacitive EIS sensor (1)
- capacitive model (1)
- carbonized rice husk (1)
- cardiac gating (1)
- cardiomyocyte biomechanics (1)
- cardiovascular MR imaging (1)
- catalytic metal (1)
- cell aerosolization (1)
- cell atomization (1)
- central symmetry test (1)
- cerebral small vessel disease (1)
- chance constrained programming (1)
- change management (1)
- chemical sensor (1)
- churches (1)
- climate change (1)
- coculture (1)
- cognitive impairment (1)
- coherent structures (1)
- colorization (1)
- community dwelling (1)
- complete block symmetry (1)
- compression behavior (1)
- computational fluid dynamics analysis (1)
- concentrating collector (1)
- conditional excess distribution (1)
- conditional expectation principle (1)
- confidence interval (1)
- connected automated vehicles (1)
- connective tissue (1)
- constitutive modeling (1)
- contactless conductivity sensor (1)
- control gate (1)
- correlation (1)
- coupled Néel–Brownian relaxation dynamics (1)
- covariance principle (1)
- crop yield (1)
- crystallization (1)
- cyber-physical production systems (1)
- dam-break (1)
- debris flow (1)
- deficit irrigation (1)
- dental trauma (1)
- deserts (1)
- design of technical systems (1)
- detection of charged macromolecules (1)
- dialysis (1)
- difficult airway (1)
- digital factory (1)
- disposal facility (1)
- distorted element (1)
- diversity management (1)
- double-lumen tube intubation (1)
- drag force (1)
- drop jump (1)
- drug metabolising enzymes (1)
- drug–drug interactions (1)
- earthquake engineering (1)
- eigensolvers (1)
- elastomers (1)
- electrocardiogram (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- electrolyte-insulator-semiconductor capacitors (1)
- electromyography (1)
- electronic nose (1)
- electrospinning (1)
- endoluminal (1)
- endospores (1)
- energy (1)
- energy absorption (1)
- energy dissipation (1)
- energy transfer (1)
- engineering (1)
- entrepreneurship education (1)
- enzymatic (bio)degradation (1)
- enzyme cascade (1)
- enzyme kinetics (1)
- enzyme-logic gate (1)
- equivalent circuit (1)
- equivalent stiffness (1)
- event-based simulation (1)
- exchangeability test (1)
- exopolysaccharides (1)
- experimental evaluation (1)
- extracorporeal membrane oxygenation (1)
- eye movement modelling examples (1)
- factory planning (1)
- fibers (1)
- field-effect structure (1)
- filamentous fungi (1)
- force generation (1)
- forecast (1)
- forehead EEG (1)
- frequency mixing (1)
- fuel cell vehicle (1)
- functional data (1)
- gait (1)
- gamification (1)
- gas sensor (1)
- gaseous hydrogen peroxide (1)
- genetic algorithm (1)
- genome engineering (1)
- geological disposal (1)
- geothermal (1)
- global optimization (1)
- glucose oxidase (GOx) (1)
- glycine (1)
- goodness-of-fit test (1)
- granular silo (1)
- harmonic radar tags (1)
- healthy aging (1)
- heat demand (1)
- heat transfer coefficient (1)
- heating system (1)
- heavy metals (1)
- hiPS cardiomyocytes (1)
- high field MR imaging (1)
- high-intensity exercise (1)
- high-k material (1)
- horseradish peroxidase (HRP) (1)
- huge dimensional data (1)
- human metabolites (1)
- humic acid (1)
- hydraulic modelling (1)
- hydrogel (1)
- hydrogels (1)
- hydroxylation (1)
- hyper-gravity (1)
- hyperelastic (1)
- hypo-gravity (1)
- hypoplasticity (1)
- ignition (1)
- impulsive effects (1)
- in-ear EEG (1)
- in-situ monitoring (1)
- incontinence (1)
- independence test (1)
- industrial agents (1)
- infill strategy (1)
- innovation management (1)
- intelligent control (1)
- intelligent energy management (1)
- intraclass correlation coefficient (1)
- irradiation (1)
- key performance indicators (1)
- lable-free detection (1)
- legal obligations (1)
- light-addressable electrode (1)
- light-addressing technologies (1)
- lignite (1)
- limit analysis (1)
- lipopolysaccharide (1)
- liquid-storage tank (1)
- liquid-structure interaction (1)
- lizards (1)
- low-rank coal (1)
- machine learning (1)
- macro-element (1)
- magnetic actuation (1)
- magnetic beads (1)
- magnetic biosensing (1)
- magnetic relaxation (1)
- magnetic resonance imaging (1)
- magnetic sandwich immunoassay (1)
- magnetic sensing (1)
- magnetic sensors (1)
- magnetic separation (1)
- magnetic tweezers (1)
- magnetophoretic velocity (1)
- mainstream deammonification (1)
- manufacturing (1)
- manufacturing data model (1)
- manufacturing flexibility (1)
- mathematical optimization (1)
- mechanical buffer (1)
- mechanical properties (1)
- metal-oxide-semiconductor structure (1)
- methanation (1)
- microfluidics (1)
- micromagnetic simulation (1)
- micronutrients (1)
- microplasma (1)
- microwave (MW) plasma (1)
- microwave measurements (1)
- mixed-integer linear programming (1)
- model performance (1)
- multi-agent systems (1)
- multi-functional material (1)
- multi-sensing platform (1)
- multianalyte detection (1)
- multinomial distribution (1)
- multiparametric immunoassays (1)
- multiplex detection (1)
- multivariate normal distribution (1)
- muscle mechanics (1)
- nanobelts (1)
- nanoparticle coverage (1)
- neutrons (1)
- next generation network (1)
- nitrogen elimination (1)
- non-simplex S-FEM elements (1)
- nonlinear VNA measurements (1)
- nonlinear radar (1)
- nonlinear transient analyses (1)
- novel photoexcitation method (1)
- nuclear waste (1)
- numerical model (1)
- on-chip integrated addressable EISCAP sensors (1)
- onion (1)
- optical fibers (1)
- optical sensor setup (1)
- optical spore trapping (1)
- optical trapping (1)
- optimization (1)
- optimization system (1)
- organosilanes (1)
- overload (1)
- parabolic flight (1)
- penicillinase (1)
- performance analysis (1)
- performance testing (1)
- phonocardiogram (1)
- physical model (1)
- physiology (1)
- plant virus detection (1)
- plasma jet (1)
- plug flow reactor (1)
- plug-based microfluidic device (1)
- point-focussing system (1)
- poly(d, l-lactic acid) (1)
- polyaspartic acid (1)
- polyetheretherketone (1)
- polyetheretherketone (PEEK) (1)
- polystyrene sulfonate (1)
- porous materials (1)
- portfolio risk (1)
- prevention (1)
- product bundling (1)
- product liability (1)
- production planning and control (1)
- programming (1)
- prostate cancer (1)
- prostatectomy (1)
- proton therapy (1)
- protons (1)
- psychosocial (1)
- pullulan (1)
- qNMR (1)
- quality of life (1)
- random effects (1)
- random effects meta-regression model (1)
- raytracing (1)
- rehabilitation (1)
- relative dosimetry (1)
- reliability of structures (1)
- remote sensing (1)
- research association (1)
- resilience (1)
- retention time (1)
- retinal microvasculature (1)
- retinal vessels (1)
- rubber (1)
- running (1)
- sEMG (1)
- sarcomere operating length (1)
- scanned light pulse technique (1)
- seismic response (1)
- separable Hilbert space (1)
- series elastic element behavior (1)
- service-oriented architectures (1)
- shakedown analysis (1)
- shoulder (1)
- silanization (1)
- simulation (1)
- sizing (1)
- slum classification (1)
- smooth muscle contraction (1)
- soil amendment (1)
- soil health (1)
- soil remediation (1)
- solar process heat (1)
- spatial resolution (1)
- spore kill rate (1)
- sprint start (1)
- standard error of measurement (1)
- sterilisation (1)
- sterility (1)
- sterilization (1)
- sterilization conditions (1)
- stiffness (1)
- stochastic optimization (1)
- stochastic programming (1)
- strain energy function (1)
- stretch reflex (1)
- stretch-shortening cycle (1)
- structure-soil-structure interaction (1)
- superabsorbent polymers (1)
- superparamagnetic bead (1)
- superparamagnetic nanoparticles (1)
- supramolecular structures (1)
- surface functionalization (1)
- surface modification (1)
- survival (1)
- sustainability (1)
- swelling properties (1)
- swimming (1)
- system optimization (1)
- system synthesis (1)
- technical operations research (1)
- technology planning (1)
- telecommunication (1)
- temperature (1)
- tendon rupture (1)
- test-retest reliability (1)
- theory and modeling (1)
- thermal dose (1)
- tilted constant illumination (1)
- tissue temperature (1)
- transmit antenna arrays (1)
- transponder (1)
- transporters (1)
- tri-lineage differentiation (1)
- truss (1)
- turnip vein clearing virus (TVCV) (1)
- twin-fluid atomizer (1)
- ultrasonography (1)
- uniformly most powerful invariant test (1)
- unloading (1)
- urease (1)
- vault (1)
- video learning (1)
- videolaryngoscopy (1)
- virgin passive (1)
- viscoelasticity (1)
- visualization (1)
- walking (1)
- walking gait (1)
- wastewater (1)
- water economy (1)
- water supply design (1)
- yield (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (1299)
- INB - Institut für Nano- und Biotechnologien (484)
- Fachbereich Chemie und Biotechnologie (454)
- Fachbereich Elektrotechnik und Informationstechnik (400)
- IfB - Institut für Bioengineering (388)
- Fachbereich Energietechnik (354)
- Fachbereich Luft- und Raumfahrttechnik (240)
- Fachbereich Maschinenbau und Mechatronik (142)
- Fachbereich Wirtschaftswissenschaften (105)
- Fachbereich Bauingenieurwesen (64)
- Solar-Institut Jülich (41)
- ECSM European Center for Sustainable Mobility (23)
- Sonstiges (21)
- Institut fuer Angewandte Polymerchemie (20)
- Freshman Institute (17)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (14)
- Fachbereich Gestaltung (12)
- Nowum-Energy (12)
- Fachbereich Architektur (9)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (5)
Solution of plane anisotropic elastostatical boundary value problems by singular integral equations
(1982)
Light-addressable potentiometric sensors for quantitative spatial imaging of chemical species
(2017)
A light-addressable potentiometric sensor (LAPS) is a semiconductor-based chemical sensor, in which a measurement site on the sensing surface is defined by illumination. This light addressability can be applied to visualize the spatial distribution of pH or the concentration of a specific chemical species, with potential applications in the fields of chemistry, materials science, biology, and medicine. In this review, the features of this chemical imaging sensor technology are compared with those of other technologies. Instrumentation, principles of operation, and various measurement modes of chemical imaging sensor systems are described. The review discusses and summarizes state-of-the-art technologies, especially with regard to the spatial resolution and measurement speed; for example, a high spatial resolution in a submicron range and a readout speed in the range of several tens of thousands of pixels per second have been achieved with the LAPS. The possibility of combining this technology with microfluidic devices and other potential future developments are discussed.
The light-addressable potentiometric sensor (LAPS) is an electrochemical sensor with a field-effect structure to detect the variation of the Nernst potential at its sensor surface, the measured area on which is defined by illumination. Thanks to this light-addressability, the LAPS can be applied to chemical imaging sensor systems, which can visualize the two-dimensional distribution of a particular target ion on the sensor surface. Chemical imaging sensor systems are expected to be useful for analysis of reaction and diffusion in various electrochemical and biological samples. Recent developments of LAPS-based chemical imaging sensor systems, in terms of the spatial resolution, measurement speed, image quality, miniaturization and integration with microfluidic devices, are summarized and discussed.
The artificial olfactory image was proposed by Lundström et al. in 1991 as a new strategy for an electronic nose system which generated a two-dimensional mapping to be interpreted as a fingerprint of the detected gas species. The potential distribution generated by the catalytic metals integrated into a semiconductor field-effect structure was read as a photocurrent signal generated by scanning light pulses. The impact of the proposed technology spread beyond gas sensing, inspiring the development of various imaging modalities based on the light addressing of field-effect structures to obtain spatial maps of pH distribution, ions, molecules, and impedance, and these modalities have been applied in both biological and non-biological systems. These light-addressing technologies have been further developed to realize the position control of a faradaic current on the electrode surface for localized electrochemical reactions and amperometric measurements, as well as the actuation of liquids in microfluidic devices.
This contribution discusses the utilization of RF power in an MRI system with RF mode shimming which enables the superposition of circularly polarized modes of a transmit RF coil array driven by a Butler matrix. Since the required power for the individual modes can vary widely, mode-shimming can result in a significant underutilization of the total available RF power. A variable power combiner (VPC) is proposed to improve the power utilization: it can be realized as a reconfiguration of the MRI transmit system by the inclusion of one additional matrix network which receives the power from all transmit amplifiers at its input ports and provides any desired (combined) power distribution at its output ports by controlling the phase and amplitude of the amplifiers’ input signals. The power distribution at the output ports of the VPC is then fed into the “mode” ports of the coil array Butler matrix in order to superimpose the spatial modes at the highest achievable power utilization. The VPC configuration is compared to the standard configuration of the transmit chain of our MRI system with 8 transmit channels and 16 coils. In realistic scenarios, improved power utilization was achieved from 17% to 60% and from 14% to 55% for an elliptical phantom and a region of interest in the abdomen, respectively, and an increase of the power utilization of 1 dB for a region of interest in the upper leg. In general, it is found that the VPC allows significant improvement in power utilization when the shimming solution demands only a few modes to be energized, while the technique can yield loss in power utilization in cases with many modes required at high power level.
The composition of plant biomass varies depending on the feedstock and pre-treatment conditions and influences its processing in biorefineries. In order to ensure optimal process conditions, the quantitative proportion of the main polymeric components of the pre-treated biomass has to be determined. Current standard procedures for biomass compositional analysis are complex, the measurements are afflicted with errors and therefore often not comparable. Hence, new powerful analytical methods are urgently required to characterize biomass. In this contribution, Differential Scanning Calorimetry (DSC) was applied in combination with multivariate data analysis (MVA) to detect the cellulose content of the plant biomass pretreated by Liquid Hot Water (LHW) and Organosolv processes under various conditions. Unlike conventional techniques, the developed analytic method enables the accurate quantification of monosaccharide content of the plant biomass without any previous sample preparation. It is easy to handle and avoids errors in sample preparation.
A multi-spot light-addressable potentiometric sensor (LAPS), which belongs to the family of semiconductor field-effect devices, was applied for label-free detection of double-stranded deoxyribonucleic acid (dsDNA) molecules by their intrinsic molecular charge. To reduce the distance between the DNA charge and sensor surface and thus, to enhance the electrostatic coupling between the dsDNA molecules and the LAPS, the negatively charged dsDNA molecules were electrostatically adsorbed onto the gate surface of the LAPS covered with a positively charged weak polyelectrolyte layer of PAH (poly(allylamine hydrochloride)). The surface potential changes in each spot of the LAPS, induced by the layer-by-layer adsorption of a PAH/dsDNA bilayer, were recorded by means of photocurrent-voltage and constant-photocurrent measurements. In addition, the surface morphology of the gate surface before and after consecutive electrostatic adsorption of PAH and dsDNA layers was studied by atomic force microscopy measurements. Moreover, fluorescence microscopy was used to verify the successful adsorption of dsDNA molecules onto the PAH-modified LAPS surface. A high sensor signal of 25 mV was registered after adsorption of 10 nM dsDNA molecules. The lower detection limit is down to 0.1 nM dsDNA. The obtained results demonstrate that the PAH-modified LAPS device provides a convenient and rapid platform for the direct label-free electrical detection of in-solution hybridized dsDNA molecules.
A multi-spot (16 spots) light-addressable potentiometric sensor (MLAPS) consisting of an Al–p-Si–SiO2 structure modified with a weak polyelectrolyte layer of PAH (poly(allylamine hydrochloride)) was applied for the label-free electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge for the first time. To achieve a preferentially flat orientation of DNA strands and thus, to reduce the distance between the DNA charge and MLAPS surface, the negatively charged probe single-stranded DNAs (ssDNA) were electrostatically adsorbed onto the positively charged PAH layer using a simple layer-by-layer (LbL) technique. In this way, more DNA charge can be positioned within the Debye length, yielding a higher sensor signal. The surface potential changes in each spot induced due to the surface modification steps (PAH adsorption, probe ssDNA immobilization, hybridization with complementary target DNA (cDNA), non-specific adsorption of mismatched ssDNA) were determined from the shifts of photocurrent–voltage curves along the voltage axis. A high sensor signal of 83 mV was registered after immobilization of probe ssDNA onto the PAH layer. The hybridization signal increases from 5 mV to 32 mV with increasing the concentration of cDNA from 0.1 nM to 5 μM. In contrast, a small signal of 5 mV was recorded in the case of non-specific adsorption of fully mismatched ssDNA (5 μM). The obtained results demonstrate the potential of the MLAPS in combination with the simple and rapid LbL immobilization technique as a promising platform for the future development of multi-spot light-addressable label-free DNA chips with direct electrical readout.
A multi-spot (4 × 4 spots) light-addressable potentiometric sensor (MLAPS) consisting of an Al–p-Si–SiO2 structure has been applied for the label-free electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge for the first time. Single-stranded probe ssDNA molecules (20 bases) were covalently immobilized onto the silanized SiO2 gate surface. The unspecific adsorption of mismatch ssDNA on the MLAPS gate surface was blocked by bovine serum albumin molecules. To reduce the screening effect and to achieve a high sensor signal, the measurements were performed in a low ionic-strength solution. The photocurrent–voltage (I–V) curves were simultaneously recorded on all 16 spots after each surface functionalization step. Large shifts of I–V curves of 25 mV were registered after the DNA immobilization and hybridization event. In contrast, a small potential shift (∼5 mV) was observed in case of mismatch ssDNA, revealing good specificity of the sensor. The obtained results demonstrate the potential of the MLAPS as promising transducer platform for the multi-spot label-free electrical detection of DNA molecules by their intrinsic molecular charge.
This article discusses the contrast between the information transportation companies provide to travellers and that of their brand messaging. Companies’ brand messaging often portrays the service they provide as pleasant, stress free and perfect. Customers and users of the service, on the other hand, often describe their experience of the service as a negative one. This article suggests that the brand value would be greater if transportation companies paid more attention to the users’ experience when designing their information systems, particularly in worst case scenarios.
The manufacturing share of laser powder bed fusion (L-PBF) increases in industrial application, but still many process steps are manually operated. Additionally, it is not possible to achieve tight dimensional tolerances or low surfaces roughness. Hence, a process chain has to be set up to combine additive manufacturing (AM) with further machining technologies. To achieve a continuous workpiece flow as basis for further industrialization of L-PBF, the paper presents a novel substrate system and its application on L-PBF machines and post-processing. The substrate system consists of a zero-point clamping system and a matrix-like interface of contact pins to be substantially connected to the workpiece within the L-PBF process.
Computer Supported Communication and Cooperation – Making Information Aware / Luczak, H. ; Wolf, M.
(1999)
his report summarizes the results of a workshop on Groupware related task design which took place at the International Conference on Supporting Group Work Group'99, Arizona, from 14 th to 17 th November 1999.
The workshop was addressed to people from different
viewpoints, backgrounds, and domains:
- Researchers dealing with questions of task analysis
and task modeling for Groupware application from an
academic point of view. They may contribute modelbased design
approaches or theoretically oriented
work
- Practitioners with experience in the design and
everyday use of groupware systems. They might refer
to the practical side of the topic: "real" tasks, "real"
problems, "real" users, etc.
High resolution temperature measurement technique for materials sciences experiments in space
(1998)
Solidification of silver-germanium alloys in an amorphous matrix aboard the space station Mir
(1993)
Biopharmaceuticals such as antibodies are produced in cultivated mammalian cells, which must be monitored to comply with good manufacturing practice. We, therefore, developed a fully automated system comprising a specific exhaust gas analyzer, inline analytics and a corresponding algorithm to precisely determine the oxygen uptake rate, carbon dioxide evolution rate, carbon dioxide transfer rate, transfer quotient and respiratory quotient without interrupting the ongoing cultivation, in order to assess its reproducibility. The system was verified using chemical simulation experiments and was able to measure the respiratory activity of hybridoma cells and DG44 cells (derived from Chinese hamster ovary cells) with satisfactory results at a minimum viable cell density of ~2.0 × 10⁵ cells ml⁻¹. The system was suitable for both batch and fed-batch cultivations in bubble-aerated and membrane-aerated reactors, with and without the control of pH and dissolved oxygen.
The Pharmacokinetics and Metabolism of Lumiracoxib in Chimeric Humanized and Murinized FRG Mice
(2017)
The pharmacokinetics and metabolism of diclofenac in chimeric humanized and murinized FRG mice
(2018)
The pharmacokinetics of diclofenac were investigated following single oral doses of 10 mg/kg to chimeric liver humanized and murinized FRG and C57BL/6 mice. In addition, the metabolism and excretion were investigated in chimeric liver humanized and murinized FRG mice. Diclofenac reached maximum blood concentrations of 2.43 ± 0.9 µg/mL (n = 3) at 0.25 h post-dose with an AUCinf of 3.67 µg h/mL and an effective half-life of 0.86 h (n = 2). In the murinized animals, maximum blood concentrations were determined as 3.86 ± 2.31 µg/mL at 0.25 h post-dose with an AUCinf of 4.94 ± 2.93 µg h/mL and a half-life of 0.52 ± 0.03 h (n = 3). In C57BL/6J mice, mean peak blood concentrations of 2.31 ± 0.53 µg/mL were seen 0.25 h post-dose with a mean AUCinf of 2.10 ± 0.49 µg h/mL and a half-life of 0.51 ± 0.49 h (n = 3). Analysis of blood indicated only trace quantities of drug-related material in chimeric humanized and murinized FRG mice. Metabolic profiling of urine, bile and faecal extracts revealed a complex pattern of metabolites for both humanized and murinized animals with, in addition to unchanged parent drug, a variety of hydroxylated and conjugated metabolites detected. The profiles in humanized mice were different to those of both murinized and wild-type animals, e.g., a higher proportion of the dose was detected in the form of acyl glucuronide metabolites and much reduced amounts as taurine conjugates. Comparison of the metabolic profiles obtained from the present study with previously published data from C57BL/6J mice and humans revealed a greater, though not complete, match between chimeric humanized mice and humans, such that the liver humanized FRG model may represent a model for assessing the biotransformation of such compounds in humans.
Thermal Characterization of additive manufactured Integral Structures for Phase Change Applications
(2020)
“Infused Thermal Solutions” (ITS) introduces a method for passive thermal control to stabilize structural components thermally without active heating and cooling systems, by using phase change material (PCM) in combination with lattice – both embedded into an additive manufactured integral structure. The technology is currently under development. This paper presents the results of the thermal property measurements performed on additive manufactured ITS breadboards. Within the breadboard campaigns key characteristics of the additive manufactured specimens were derived: Mechanical parameters: specimen impermeability, minimum wall thickness, lattice structure, subsequent heat treatment. Thermal properties: thermo-optical surface properties of the additive manufactured raw material, thermal conductivity and specific heat capacity measurements. As a conclusion the paper introduces an overview of potential ITS hardware applications, expected to increase the thermal performance.
Due to their anion exchange characteristics, layered double hydroxides (LDHs) are suitable for the detoxification of aqueous, fatty acid containing fermentation substrates. The aim of this study is to examine the adsorption mechanism, using crude glycerol from plant oil esterification as a model system. Changes in the intercalation structure in relation to the amount of fatty acids adsorbed are monitored by X-ray diffraction and infra-red spectroscopy. Additionally, calcination of LDH is investigated in order to increase the binding capacity for fatty acids. Our data propose that, at ambient temperature, fatty acids can be bound to the hydrotalcite by adsorption or in addition by intercalation, depending on fatty acid concentration. The adsorption of fatty acids from crude glycerol shows a BET-like behavior. Above a fatty acid concentration of 3.5 g L−1, intercalation of fatty acids can be shown by the appearance of an increased interlayer spacing. This observation suggests a two phase adsorption process. Calcination of LDHs allows increasing the binding capacity for fatty acids by more than six times, mainly by reduction of structural CO32−.
Glucose oxidase (GOx) is an enzyme frequently used in glucose biosensors. As increased temperatures can enhance the performance of electrochemical sensors, we investigated the impact of temperature pulses on GOx that was drop-coated on flattened Pt microwires. The wires were heated by an alternating current. The sensitivity towards glucose and the temperature stability of GOx was investigated by amperometry. An up to 22-fold increase of sensitivity was observed. Spatially resolved enzyme activity changes were investigated via scanning electrochemical microscopy. The application of short (<100 ms) heat pulses was associated with less thermal inactivation of the immobilized GOx than long-term heating.
Light-addressable potentiometric sensors (LAPS) are semiconductor-based potentiometric sensors, with the advantage to detect the concentration of a chemical species in a liquid solution above the sensor surface in a spatially resolved manner. The addressing is achieved by a modulated and focused light source illuminating the semiconductor and generating a concentration-depending photocurrent. This work introduces a LAPS set-up that is able to monitor the electrical impedance in addition to the photocurrent. The impedance spectra of a LAPS structure, with and without illumination, as well as the frequency behaviour of the LAPS measurement are investigated. The measurements are supported by electrical equivalent circuits to explain the impedance and the LAPS-frequency behaviour. The work investigates the influence of different parameters on the frequency behaviour of the LAPS. Furthermore, the phase shift of the photocurrent, the influence of the surface potential as well as the changes of the sensor impedance will be discussed.
Light-addressable potentiometric sensors (LAPS) are field-effect-based sensors. A modulated light source is used to define the particular measurement spot to perform spatially resolved measurements of chemical species and to generate chemical images. In this work, an organic-LED (OLED) display has been chosen as a light source. This allows high measurement resolution and miniaturisation of the system. A new developed driving method for the OLED display optimised for LAPS-based measurements is demonstrated. The new method enables to define modulation frequencies between 1 kHz and 16 kHz and hence, reduces the measurement time of a chemical image by a factor of 40 compared to the traditional addressing of an OLED display.
Semiconductor-based chemical imaging sensors, like the light-addressable potentiometric sensor (LAPS) or the pH-imaging sensor based on a charge-coupled device (CCD), are becoming a powerful tool for label-free imaging of biological phenomena. We have proposed a polyion-based enzymatic membrane to develop an acetylcholine (ACh) imaging sensor for neural cell-activity observations. In this study, a CCD-type ACh-imaging sensor and a LAPS-type ACh-imaging sensor were fabricated and the prospect of both sensors was clarified by making a comparison of their basic characteristics.
A light-addressable potentiometric sensor (LAPS) can measure the concentration of one or several analytes at the sensor surface simultaneously in a spatially resolved manner. A modulated light pointer stimulates the semiconductor structure at the area of interest and a responding photocurrent can be read out. By simultaneous stimulation of several areas with light pointers of different modulation frequencies, the read out can be performed at the same time. With the new proposed controller electronic based on a field-programmable gate array (FPGA), it is possible to control the modulation frequencies, phase shifts, and light brightness of multiple light pointers independently and simultaneously. Thus, it is possible to investigate the frequency response of the sensor, and to examine the analyte concentration by the determination of the surface potential with the help of current/voltage curves and phase/voltage curves. Additionally, the ability to individually change the light intensities of each light pointer is used to perform signal correction.
To study chemical and biological processes, spatially resolved determination of the concentrations of one or more analyte species is of distinct interest. With a light-addressable potentiometric sensor (LAPS), chemical images can be created, which visualize the concentration distribution above the sensor plate. One important challenge is to achieve a good lateral resolution in order to detect events that take place in a small and limited region. LAPS utilizes a focused light spot to address the measurement region. By moving this light spot along the semiconductor sensor plate, the concentration distribution can be observed. In this study, we show that utilizing a pulse as light excitation instead of a traditionally used continuously modulated light excitation, the lateral resolution can be improved by a factor of 6 or more.
The compliant nature of distal limb muscle-tendon units is traditionally considered suboptimal in explosive movements when positive joint work is required. However, during accelerative running, ankle joint net mechanical work is positive. Therefore, this study aims to investigate how plantar flexor muscle-tendon behavior is modulated during fast accelerations. Eleven female sprinters performed maximum sprint accelerations from starting blocks, while gastrocnemius muscle fascicle lengths were estimated using ultrasonography. We combined motion analysis and ground reaction force measurements to assess lower limb joint kinematics and kinetics, and to estimate gastrocnemius muscle-tendon unit length during the first two acceleration steps. Outcome variables were resampled to the stance phase and averaged across three to five trials. Relevant scalars were extracted and analyzed using one-sample and two-sample t-tests, and vector trajectories were compared using statistical parametric mapping. We found that an uncoupling of muscle fascicle behavior from muscle-tendon unit behavior is effectively used to produce net positive mechanical work at the joint during maximum sprint acceleration. Muscle fascicles shortened throughout the first and second steps, while shortening occurred earlier during the first step, where negative joint work was lower compared with the second step. Elastic strain energy may be stored during dorsiflexion after touchdown since fascicles did not lengthen at the same time to dissipate energy. Thus, net positive work generation is accommodated by the reuse of elastic strain energy along with positive gastrocnemius fascicle work. Our results show a mechanism of how muscles with high in-series compliance can contribute to net positive joint work.
Training-induced increase in Achilles tendon stiffness affects tendon strain pattern during running
(2019)
Background
During the stance phase of running, the elasticity of the Achilles tendon enables the utilisation of elastic energy and allows beneficial contractile conditions for the triceps surae muscles. However, the effect of changes in tendon mechanical properties induced by chronic loading is still poorly understood. We tested the hypothesis that a training-induced increase in Achilles tendon stiffness would result in reduced tendon strain during the stance phase of running, which would reduce fascicle strains in the triceps surae muscles, particularly in the mono-articular soleus.
Methods
Eleven subjects were assigned to a training group performing isometric singleleg plantarflexion contractions three times per week for ten weeks, and another ten subjects formed a control group. Before and after the training period, Achilles tendon stiffness was estimated, and muscle-tendon mechanics were assessed during running at preferred speed using ultrasonography, kinematics and kinetics.
Results
Achilles tendon stiffness increased by 18% (P <0:01) in the training group, but the associated reduction in strain seen during isometric contractions was not statistically significant. Tendon elongation during the stance phase of running was similar after training, but tendon recoil was reduced by 30% (P <0:01), while estimated tendon force remained unchanged. Neither gastrocnemius medialis nor soleus fascicle shortening during stance was affected by training.
Discussion
These results show that a training-induced increase in Achilles tendon
stiffness altered tendon behaviour during running. Despite training-induced changes in tendon mechanical properties and recoil behaviour, the data suggest that fascicle shortening patterns were preserved for the running speed that we examined. The asymmetrical changes in tendon strain patterns supports the notion that simple inseries models do not fully explain the mechanical output of the muscle-tendon unit during a complex task like running.
Modulation of muscle-tendon interaction in the human triceps surae during an energy dissipation task
(2017)
During rapid deceleration of the body, tendons buffer part of the elongation of the muscle-tendon unit (MTU), enabling safe energy dissipation via eccentric muscle contraction. Yet, the influence of changes in tendon stiffness within the physiological range upon these lengthening contractions is unknown. This study aimed to examine the effect of training-induced stiffening of the Achilles tendon on triceps surae muscle-tendon behavior during a landing task. Twenty-one male subjects were assigned to either a 10-week resistance-training program consisting of single-leg isometric plantarflexion (n = 11) or to a non-training control group (n = 10). Before and after the training period, plantarflexion force, peak Achilles tendon strain and stiffness were measured during isometric contractions, using a combination of dynamometry, ultrasound and kinematics data. Additionally, testing included a step-landing task, during which joint mechanics and lengths of gastrocnemius and soleus fascicles, Achilles tendon, and MTU were determined using synchronized ultrasound, kinematics and kinetics data collection. After training, plantarflexion strength and Achilles tendon stiffness increased (15 and 18%, respectively), and tendon strain during landing remained similar. Likewise, lengthening and negative work produced by the gastrocnemius MTU did not change detectably. However, in the training group, gastrocnemius fascicle length was offset (8%) to a longer length at touch down and, surprisingly, fascicle lengthening and velocity were reduced by 27 and 21%, respectively. These changes were not observed for soleus fascicles when accounting for variation in task execution between tests. These results indicate that a training-induced increase in tendon stiffness does not noticeably affect the buffering action of the tendon when the MTU is rapidly stretched. Reductions in gastrocnemius fascicle lengthening and lengthening velocity during landing occurred independently from tendon strain. Future studies are required to provide insight into the mechanisms underpinning these observations and their influence on energy dissipation.
Dynamic retinal vessel analysis (DVA) provides a non-invasive way to assess microvascular function in patients and potentially to improve predictions of individual cardiovascular (CV) risk. The aim of our study was to use untargeted machine learning on DVA in order to improve CV mortality prediction and identify corresponding response alterations.
Immunosorbent turnip vein clearing virus (TVCV) particles displaying the IgG-binding domains D and E of Staphylococcus aureus protein A (PA) on every coat protein (CP) subunit (TVCVPA) were purified from plants via optimized and new protocols. The latter used polyethylene glycol (PEG) raw precipitates, from which virions were selectively re-solubilized in reverse PEG concentration gradients. This procedure improved the integrity of both TVCVPA and the wild-type subgroup 3 tobamovirus. TVCVPA could be loaded with more than 500 IgGs per virion, which mediated the immunocapture of fluorescent dyes, GFP, and active enzymes. Bi-enzyme ensembles of cooperating glucose oxidase and horseradish peroxidase were tethered together on the TVCVPA carriers via a single antibody type, with one enzyme conjugated chemically to its Fc region, and the other one bound as a target, yielding synthetic multi-enzyme complexes. In microtiter plates, the TVCVPA-displayed sugar-sensing system possessed a considerably increased reusability upon repeated testing, compared to the IgG-bound enzyme pair in the absence of the virus. A high coverage of the viral adapters was also achieved on Ta2O5 sensor chip surfaces coated with a polyelectrolyte interlayer, as a prerequisite for durable TVCVPA-assisted electrochemical biosensing via modularly IgG-assembled sensor enzymes.
In this review article, we are going to present an overview on possible applications of light-addressable electrodes (LAE) as actuator/manipulation devices besides classical electrode structures. For LAEs, the electrode material consists of a semiconductor. Illumination with a light source with the appropiate wavelength leads to the generation of electron-hole pairs which can be utilized for further photoelectrochemical reaction. Due to recent progress in light-projection technologies, highly dynamic and flexible illumination patterns can be generated, opening new possibilities for light-addressable electrodes. A short introduction on semiconductor–electrolyte interfaces with light stimulation is given together with electrode-design approaches. Towards applications, the stimulation of cells with different electrode materials and fabrication designs is explained, followed by analyte-manipulation strategies and spatially resolved photoelectrochemical deposition of different material types.
In lab-on-chip systems, electrodes are important for the manipulation (e.g., cell stimulation, electrolysis) within such systems. An alternative to commonly used electrode structures can be a light-addressable electrode. Here, due to the photoelectric effect, the conducting area can be adjusted by modification of the illumination area which enables a flexible control of the electrode. In this work, titanium dioxide based light-addressable electrodes are fabricated by a sol–gel technique and a spin-coating process, to deposit a thin film on a fluorine-doped tin oxide glass. To characterize the fabricated electrodes, the thickness, and morphological structure are measured by a profilometer and a scanning electron microscope. For the electrochemical behavior, the dark current and the photocurrent are determined for various film thicknesses. For the spatial resolution behavior, the dependency of the photocurrent while changing the area of the illuminated area is studied. Furthermore, the addressing of single fluid compartments in a three-chamber system, which is added to the electrode, is demonstrated.
The feasibility of light-addressed detection and manipulation of pH gradients inside an electrochemical microfluidic cell was studied. Local pH changes, induced by a light-addressable electrode (LAE), were detected using a light-addressable potentiometric sensor (LAPS) with different measurement modes representing an actuator-sensor system. Biosensor functionality was examined depending on locally induced pH gradients with the help of the model enzyme penicillinase, which had been immobilized in the microfluidic channel. The surface morphology of the LAE and enzyme-functionalized LAPS was studied by scanning electron microscopy. Furthermore, the penicillin sensitivity of the LAPS inside the microfluidic channel was determined with regard to the analyte’s pH influence on the enzymatic reaction rate. In a final experiment, the LAE-controlled pH inhibition of the enzyme activity was monitored by the LAPS.
Acetoin and diacetyl have a major impact on the flavor of alcoholic beverages such as wine or beer. Therefore, their measurement is important during the fermentation process. Until now, gas chromatographic techniques have typically been applied; however, these require expensive laboratory equipment and trained staff, and do not allow for online monitoring. In this work, a capacitive electrolyte–insulator–semiconductor sensor modified with tobacco mosaic virus (TMV) particles as enzyme nanocarriers for the detection of acetoin and diacetyl is presented. The enzyme acetoin reductase from Alkalihalobacillus clausii DSM 8716ᵀ is immobilized via biotin–streptavidin affinity, binding to the surface of the TMV particles. The TMV-assisted biosensor is electrochemically characterized by means of leakage–current, capacitance–voltage, and constant capacitance measurements. In this paper, the novel biosensor is studied regarding its sensitivity and long-term stability in buffer solution. Moreover, the TMV-assisted capacitive field-effect sensor is applied for the detection of diacetyl for the first time. The measurement of acetoin and diacetyl with the same sensor setup is demonstrated. Finally, the successive detection of acetoin and diacetyl in buffer and in diluted beer is studied by tuning the sensitivity of the biosensor using the pH value of the measurement solution.
Utilizing an appropriate enzyme immobilization strategy is crucial for designing enzyme-based biosensors. Plant virus-like particles represent ideal nanoscaffolds for an extremely dense and precise immobilization of enzymes, due to their regular shape, high surface-to-volume ratio and high density of surface binding sites. In the present work, tobacco mosaic virus (TMV) particles were applied for the co-immobilization of penicillinase and urease onto the gate surface of a field-effect electrolyte-insulator-semiconductor capacitor (EISCAP) with a p-Si-SiO₂-Ta₂O₅ layer structure for the sequential detection of penicillin and urea. The TMV-assisted bi-enzyme EISCAP biosensor exhibited a high urea and penicillin sensitivity of 54 and 85 mV/dec, respectively, in the concentration range of 0.1–3 mM. For comparison, the characteristics of single-enzyme EISCAP biosensors modified with TMV particles immobilized with either penicillinase or urease were also investigated. The surface morphology of the TMV-modified Ta₂O₅-gate was analyzed by scanning electron microscopy. Additionally, the bi-enzyme EISCAP was applied to mimic an XOR (Exclusive OR) enzyme logic gate.