Conference Proceeding
Refine
Year of publication
- 2016 (80) (remove)
Document Type
- Conference Proceeding (80) (remove)
Keywords
- Assessment (1)
- Building Systems (1)
- Business Simulations (1)
- Diversity (1)
- Drinking Water Supply (1)
- Engineering Education (1)
- Gamification (1)
- Gender (1)
- Higher Education (1)
- Mixed-Integer Nonlinear Optimisation (1)
- Parametric Design (1)
- Parametric Modelling (1)
- Reference Process Model (1)
- Referenzmodellierung (1)
- Serious Games (1)
- Solver Per- formance (1)
- Structuralist Architecture (1)
- Subject-oriented Business Process Management (1)
- System Design Problem (1)
- TM Forum (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (17)
- Fachbereich Elektrotechnik und Informationstechnik (16)
- Fachbereich Luft- und Raumfahrttechnik (14)
- IfB - Institut für Bioengineering (14)
- Fachbereich Maschinenbau und Mechatronik (9)
- Fachbereich Energietechnik (8)
- Fachbereich Bauingenieurwesen (7)
- Fachbereich Chemie und Biotechnologie (7)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (4)
- ECSM European Center for Sustainable Mobility (3)
- INB - Institut für Nano- und Biotechnologien (3)
- Nowum-Energy (3)
- Fachbereich Wirtschaftswissenschaften (2)
- Solar-Institut Jülich (2)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (2)
- Fachbereich Architektur (1)
Evaluation of fragility curves for a three-storey-reinforced-concrete mock-up of SMART 2013 project
(2016)
Entwicklung eines Kletterroboters zur Diagnose und Instandsetzung von Windenergieanlagen (SMART)
(2016)
The structure of the female pelvic floor (PF) is an inter-related system of bony pelvis,muscles, pelvic organs, fascias, ligaments, and nerves with multiple functions. Mechanically, thepelvic organ support system are of two types: (I) supporting system of the levator ani (LA) muscle,and (II) the suspension system of the endopelvic fascia condensation [1], [2]. Significantdenervation injury to the pelvic musculature, depolimerization of the collagen fibrils of the softvaginal hammock, cervical ring and ligaments during pregnancy and vaginal delivery weakens thenormal functions of the pelvic floor. Pelvic organ prolapse, incontinence, sexual dysfunction aresome of the dysfunctions which increases progressively with age and menopause due toweakened support system according to the Integral theory [3]. An improved 3D finite elementmodel of the female pelvic floor as shown in Fig. 1 is constructed that: (I) considers the realisticsupport of the organs to the pelvic side walls, (II) employs the improvement of our previous FEmodel [4], [5] along with the patient based geometries, (III) incorporates the realistic anatomy andboundary conditions of the endopelvic (pubocervical and rectovaginal) fascia, and (IV) considersvarying stiffness of the endopelvic fascia in the craniocaudal direction [3]. Several computationsare carried out on the presented computational model with healthy and damaged supportingtissues, and comparisons are made to understand the physiopathology of the female PF disorders.
The human arm consists of the humerus (upper arm), the medial ulna and the lateral radius (forearm). The joint between the humerus and the ulna is called humeroulnar joint and the joint between the humerus and the radius is called humeroradial joint. Lateral and medial collateral ligaments stabilize the elbow. Statistically, 2.5 out of 10,000 people suffer from radial head fractures [1]. In these fractures the cartilage is often affected. Caused by the injured cartilage, degenerative diseases like posttraumatic arthrosis may occur. The resulting pain and reduced range of motion have an impact on the patient’s quality of life. Until now, there has not been a treatment which allows typical loads in daily life activities and offers good long-term results. A new surgical approach was developed with the motivation to reduce the progress of the posttraumatic arthrosis. Here, the radius is shortened by 3 mm in the proximal part [2]. By this means, the load of the radius is intended to be reduced due to a load shift to the ulna. Since the radius is the most important stabilizer of the elbow it has to be confirmed that the stability is not affected. In the first test (Fig. 1 left), pressure distributions within the humeroulnar and humeroradial joints a native and a shortened radius were measured using resistive pressure sensors (I5076 and I5027, Tekscan, USA). The humerus was loaded axially in a tension testing machine (Z010, Zwick Roell, Germany) in 50 N steps up to 400 N. From the humerus the load is transmitted through both the radius and the ulna into the hand which is fixed on the ground. In the second test (Fig. 1 right), the joint stability was investigated using a digital image correlation system to measure the displacement of the ulna. Here, the humerus is fixed with a desired flexion angle and the unconstrained forearm lies on the ground. A rope connects the load actuator with a hook fixed in the ulna. A guide roller is used so that the rope pulls the ulna horizontally when a tensile load is applied. This creates a moment about the elbow joint with a maximum value of 7.5 Nm. Measurements were performed with varying flexion angles (0°, 30°, 60°, 90°, 120°). For both tests and each measurement, seven specimens were used. Student ́s t-test was employed to determine whether the mean values of the measurements in native specimen and operated specimens differ significantly.
Malware auf Smartphones ist ein Problem, dem auch Strafverfolgungsbehörden immer häufiger gegenüberstehen.
Insbesondere Telefone, bei denen potentiell schadhafte Apps zu einem finanziellen Schaden
geführt haben, finden sich auf den Schreibtischen der Polizei wieder. Dabei müssen die Ermittler möglichst
schnell und gezielt erkennen können, ob eine App tatsächlich schadhaft manipuliert wurde, was
manipuliert wurde und mit wem die App kommuniziert. Klassische Malware-Erkennungsverfahren helfen
zwar bei der generellen Erkennung schadhafter Software, sind aber für die polizeiliche Praxis nicht
geeignet. Dieses Paper stellt ein Programm vor, welches gerade die forensischen Fragestellungen berücksichtigt
und so für den Einsatz in der Strafverfolgung in Frage kommt.
Unser Zuhause wird zunehmend intelligenter. Smart Homes bieten uns die Steuerung von Haus- oder Unterhaltungstechnik bequem vom Smartphone aus. Junge Familien nutzen die Technologie, um mittels vernetzten Babymonitorsystemen ihren Nachwuchs von überall aus im Blick zu haben. Davon auszugehen, dass solche Systeme mit einem Fokus auf Sicherheit entwickelt wurden, um die sehr persönlichen Daten zu schützen, ist jedoch ein Trugschluss. Die Untersuchung eines handelsüblichen und keineswegs billigen Systems zeigt, dass die Geräte sehr einfach kompromittiert und missbraucht werden können.
Smoothed Finite Element Methods for Nonlinear Solid Mechanics Problems: 2D and 3D Case Studies
(2016)
The Smoothed Finite Element Method (SFEM) is presented as an edge-based and a facebased techniques for 2D and 3D boundary value problems, respectively. SFEMs avoid shortcomings of the standard Finite Element Method (FEM) with lower order elements such as overly stiff behavior, poor stress solution, and locking effects. Based on the idea of averaging spatially the standard strain field of the FEM over so-called smoothing domains SFEM calculates the stiffness matrix for the same number of degrees of freedom (DOFs) as those of the FEM. However, the SFEMs significantly improve accuracy and convergence even for distorted meshes and/or nearly incompressible materials.
Numerical results of the SFEMs for a cardiac tissue membrane (thin plate inflation) and an artery (tension of 3D tube) show clearly their advantageous properties in improving accuracy particularly for the distorted meshes and avoiding shear locking effects.