Conference Proceeding
Refine
Year of publication
- 2024 (5)
- 2023 (30)
- 2022 (43)
- 2021 (46)
- 2020 (46)
- 2019 (74)
- 2018 (64)
- 2017 (66)
- 2016 (65)
- 2015 (71)
- 2014 (51)
- 2013 (57)
- 2012 (59)
- 2011 (44)
- 2010 (48)
- 2009 (52)
- 2008 (37)
- 2007 (44)
- 2006 (60)
- 2005 (23)
- 2004 (22)
- 2003 (22)
- 2002 (25)
- 2001 (12)
- 2000 (12)
- 1999 (7)
- 1998 (8)
- 1997 (8)
- 1996 (4)
- 1995 (4)
- 1993 (6)
- 1992 (3)
- 1991 (2)
- 1990 (1)
- 1989 (3)
- 1988 (3)
- 1986 (1)
- 1985 (2)
- 1984 (3)
- 1983 (2)
- 1981 (2)
- 1980 (1)
- 1979 (1)
- 1978 (3)
- 1975 (2)
- 1973 (2)
Document Type
- Conference Proceeding (1146) (remove)
Language
- English (1146) (remove)
Keywords
- Biosensor (25)
- CAD (7)
- Finite-Elemente-Methode (7)
- civil engineering (7)
- Bauingenieurwesen (6)
- Blitzschutz (6)
- Enterprise Architecture (5)
- Clusterion (4)
- Energy storage (4)
- Gamification (4)
- Leadership (4)
- Limit analysis (4)
- Natural language processing (4)
- Power plants (4)
- Sonde (4)
- Telekommunikationsmarkt (4)
- hydrogen (4)
- solar sail (4)
- Air purification (3)
- Associated liquids (3)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (230)
- Fachbereich Medizintechnik und Technomathematik (208)
- Fachbereich Luft- und Raumfahrttechnik (178)
- Fachbereich Energietechnik (177)
- IfB - Institut für Bioengineering (147)
- Solar-Institut Jülich (110)
- Fachbereich Maschinenbau und Mechatronik (107)
- Fachbereich Bauingenieurwesen (73)
- Fachbereich Wirtschaftswissenschaften (51)
- ECSM European Center for Sustainable Mobility (50)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (46)
- INB - Institut für Nano- und Biotechnologien (39)
- Fachbereich Chemie und Biotechnologie (23)
- Kommission für Forschung und Entwicklung (16)
- Nowum-Energy (11)
- Fachbereich Architektur (7)
- Fachbereich Gestaltung (4)
- Institut fuer Angewandte Polymerchemie (2)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (2)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
Application of Low NOx Micro-mix Hydrogen Combustion to 2MW Class Industrial Gas Turbine Combustor
(2019)
Flexible Fuel Operation of a Dry-Low-Nox Micromix Combustor with Variable Hydrogen Methane Mixtures
(2019)
The utilization of phase change material (PCM) for latent heat storage and thermal control of spacecraft has been demonstrated in the past in few missions only. One limiting factor was the fact that all concepts developed so far envisioned the PCM to be applied as an additional capacitor, encapsulated in its own housing, leading to mass, efficiency and accommodation challenges. Recently, the application of PCM within the scan cavity of a GEOS type satellite has been suggested, in order to tackle thermal issues due to direct sun intrusion (Choi, M., 2014). However, the application of PCM in such complex mechanical structures is extremely challenging. A new concept to tackle this issue is currently under development at the FH Aachen University of Applied Sciences. The concept "Infused Thermal Solutions (ITS)" is based on the idea to 3D print metallic structures in their regular functional shape, but double walled with internal lattice support structures, allowing the infusion of a PCM layer directly into the voids and eliminating the need for additional parts and interfaces. Together with OHB System, FH Aachen theoretically studied the application of this technology to the Meteosat Third Generation (MTG) Infra-Red Sounder (IRS) instrument. The study focuses on the scan cavity and entrance baffling assembly (EBA) of the IRS. It consists of thermal analyses, 3D-redesign and bread boarding of a scaled and PCM infused EBA version. In the thermal design of the alternative EBA, PCM was applied directly into the EBA, simulating the worst hot case sun intrusion of the mission. By applying 4kg of PCM (to a 60kg baffle) the EBA temperature excursions during sun intrusion were limited from 140K to 30K, leading to a significant thermo-opto-elastic performance gain. This paper introduces the ITS concept development status.
Masonry infill walls are commonly used in reinforced concrete (RC) frame structures, also in seismically active areas, although they often experience serious damage during earthquakes. One of the main reasons for their poor behaviour is the connection to the frame, which is usually constructed using mortar. This paper describes the novel solution for infill/frame connection based on application of elastomeric material between them. The system called INODIS (Innovative Decoupled Infill System) has the aim to postpone the activation of infill in in-plane direction and at the same time to provide sufficient out-of-plane support. First, experimental tests on infilled frame specimens are presented and the comparison of the results between traditionally infilled frames and infilled frames with the INODIS system are given. The results are then used for calibration and validation of numerical model, which can be further employed for investigating the influence of some material parameters on the behaviour of infilled frames with the INODIS system.
Effective training requires high muscle forces potentially leading to training-induced injuries. Thus, continuous monitoring and controlling of the loadings applied to the musculoskeletal system along the motion trajectory is required. In this paper, a norm-optimal iterative learning control algorithm for the robot-assisted training is developed. The algorithm aims at minimizing the external knee joint moment, which is commonly used to quantify the loading of the medial compartment. To estimate the external knee joint moment, a musculoskeletal lower extremity model is implemented in OpenSim and coupled with a model of an industrial robot and a force plate mounted at its end-effector. The algorithm is tested in simulation for patients with varus, normal and valgus alignment of the knee. The results show that the algorithm is able to minimize the external knee joint moment in all three cases and converges after less than seven iterations.
We propose a stochastic programming method to analyse limit and shakedown of structures under random strength with lognormal distribution. In this investigation a dual chance constrained programming algorithm is developed to calculate simultaneously both the upper and lower bounds of the plastic collapse limit or the shakedown limit. The edge-based smoothed finite element method (ES-FEM) using three-node linear triangular elements is used.
Electromechanical model of hiPSC-derived ventricular cardiomyocytes cocultured with fibroblasts
(2018)
The CellDrum provides an experimental setup to study the mechanical effects of fibroblasts co-cultured with hiPSC-derived ventricular cardiomyocytes. Multi-scale computational models based on the Finite Element Method are developed. Coupled electrical cardiomyocyte-fibroblast models (cell level) are embedded into reaction-diffusion equations (tissue level) which compute the propagation of the action potential in the cardiac tissue. Electromechanical coupling is realised by an excitation-contraction model (cell level) and the active stress arising during contraction is added to the passive stress in the force balance, which determines the tissue displacement (tissue level). Tissue parameters in the model can be identified experimentally to the specific sample.
The overall objective of this study is to develop a new external fixator, which closely maps the native kinematics of the elbow to decrease the joint force resulting in reduced rehabilitation time and pain. An experimental setup was designed to determine the native kinematics of the elbow during flexion of cadaveric arms. As a preliminary study, data from literature was used to modify a published biomechanical model for the calculation of the joint and muscle forces. They were compared to the original model and the effect of the kinematic refinement was evaluated. Furthermore, the obtained muscle forces were determined in order to apply them in the experimental setup. The joint forces in the modified model differed slightly from the forces in the original model. The muscle force curves changed particularly for small flexion angles but their magnitude for larger angles was consistent.