Refine
Year of publication
- 2024 (25)
- 2023 (101)
- 2022 (132)
- 2021 (145)
- 2020 (157)
- 2019 (192)
- 2018 (168)
- 2017 (154)
- 2016 (154)
- 2015 (176)
- 2014 (166)
- 2013 (171)
- 2012 (154)
- 2011 (184)
- 2010 (179)
- 2009 (185)
- 2008 (155)
- 2007 (149)
- 2006 (160)
- 2005 (130)
- 2004 (161)
- 2003 (106)
- 2002 (130)
- 2001 (106)
- 2000 (108)
- 1999 (109)
- 1998 (99)
- 1997 (99)
- 1996 (81)
- 1995 (78)
- 1994 (86)
- 1993 (59)
- 1992 (54)
- 1991 (29)
- 1990 (39)
- 1989 (45)
- 1988 (57)
- 1987 (32)
- 1986 (19)
- 1985 (34)
- 1984 (22)
- 1983 (20)
- 1982 (29)
- 1981 (20)
- 1980 (36)
- 1979 (24)
- 1978 (34)
- 1977 (14)
- 1976 (13)
- 1975 (12)
- 1974 (3)
- 1973 (2)
- 1972 (2)
- 1971 (1)
- 1968 (1)
Document Type
- Article (3226)
- Conference Proceeding (1146)
- Part of a Book (184)
- Book (144)
- Doctoral Thesis (30)
- Patent (25)
- Other (9)
- Report (9)
- Working Paper (6)
- Lecture (5)
- Poster (4)
- Preprint (4)
- Talk (4)
- Master's Thesis (2)
- Bachelor Thesis (1)
- Contribution to a Periodical (1)
- Habilitation (1)
Language
- English (4801) (remove)
Keywords
- Biosensor (25)
- Finite-Elemente-Methode (12)
- Einspielen <Werkstoff> (10)
- CAD (8)
- civil engineering (8)
- Bauingenieurwesen (7)
- Blitzschutz (6)
- FEM (6)
- Gamification (6)
- Limit analysis (6)
- Shakedown analysis (6)
- avalanche (6)
- shakedown analysis (6)
- Clusterion (5)
- Earthquake (5)
- Enterprise Architecture (5)
- MINLP (5)
- solar sail (5)
- Air purification (4)
- Diversity Management (4)
Institute
- Fachbereich Medizintechnik und Technomathematik (1668)
- Fachbereich Elektrotechnik und Informationstechnik (693)
- IfB - Institut für Bioengineering (620)
- Fachbereich Energietechnik (579)
- INB - Institut für Nano- und Biotechnologien (555)
- Fachbereich Chemie und Biotechnologie (534)
- Fachbereich Luft- und Raumfahrttechnik (477)
- Fachbereich Maschinenbau und Mechatronik (278)
- Fachbereich Wirtschaftswissenschaften (207)
- Solar-Institut Jülich (164)
- Fachbereich Bauingenieurwesen (153)
- ECSM European Center for Sustainable Mobility (79)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (67)
- Nowum-Energy (28)
- Fachbereich Gestaltung (25)
- Institut fuer Angewandte Polymerchemie (23)
- Sonstiges (21)
- Fachbereich Architektur (20)
- Freshman Institute (18)
- Kommission für Forschung und Entwicklung (18)
In this paper we report on CO2 Meter, a do-it-yourself carbon dioxide measuring device for the classroom. Part of the current measures for dealing with the SARS-CoV-2 pandemic is proper ventilation in indoor settings. This is especially important in schools with students coming back to the classroom even with high incidents rates. Static ventilation patterns do not consider the individual situation for a particular class. Influencing factors like the type of activity, the physical structure or the room occupancy are not incorporated. Also, existing devices are rather expensive and often provide only limited information and only locally without any networking. This leaves the potential of analysing the situation across different settings untapped. Carbon dioxide level can be used as an indicator of air quality, in general, and of aerosol load in particular. Since, according to the latest findings, SARS-CoV-2 can be transmitted primarily in the form of aerosols, carbon dioxide may be used as a proxy for the risk of a virus infection. Hence, schools could improve the indoor air quality and potentially reduce the infection risk if they actually had measuring devices available in the classroom. Our device supports schools in ventilation and it allows for collecting data over the Internet to enable a detailed data analysis and model generation. First deployments in schools at different levels were received very positively. A pilot installation with a larger data collection and analysis is underway.
Objective
Hemodialysis patients show an approximately threefold higher prevalence of cognitive impairment compared to the age-matched general population. Impaired microcirculatory function is one of the assumed causes. Dynamic retinal vessel analysis is a quantitative method for measuring neurovascular coupling and microvascular endothelial function. We hypothesize that cognitive impairment is associated with altered microcirculation of retinal vessels.
Methods
152 chronic hemodialysis patients underwent cognitive testing using the Montreal Cognitive Assessment. Retinal microcirculation was assessed by Dynamic Retinal Vessel Analysis, which carries out an examination recording retinal vessels' reaction to a flicker light stimulus under standardized conditions.
Results
In unadjusted as well as in adjusted linear regression analyses a significant association between the visuospatial executive function domain score of the Montreal Cognitive Assessment and the maximum arteriolar dilation as response of retinal arterioles to the flicker light stimulation was obtained.
Conclusion
This is the first study determining retinal microvascular function as surrogate for cerebral microvascular function and cognition in hemodialysis patients. The relationship between impairment in executive function and reduced arteriolar reaction to flicker light stimulation supports the involvement of cerebral small vessel disease as contributing factor for the development of cognitive impairment in this patient population and might be a target for noninvasive disease monitoring and therapeutic intervention.
Coincident events in two scintillator crystals coupled to photomultipliers (PMT) are detected by processing just the digital data of the recorded pulses. For this purpose the signals from both PMTs are continuously sampled by free-running ADCs at a sampling rate of 40 MHz. For each sampled pulse the starting time is determined by processing the pulse data. Even a fairly simple interpolating algorithm results in a FWHM of about 2 ns.
The connective tissues such as tendons contain an extracellular matrix (ECM) comprising collagen fibrils scattered within the ground substance. These fibrils are instrumental in lending mechanical stability to tissues. Unfortunately, our understanding of how collagen fibrils reinforce the ECM remains limited, with no direct experimental evidence substantiating current theories. Earlier theoretical studies on collagen fibril reinforcement in the ECM have relied predominantly on the assumption of uniform cylindrical fibers, which is inadequate for modelling collagen fibrils, which possessed tapered ends. Recently, Topçu and colleagues published a paper in the International Journal of Solids and Structures, presenting a generalized shear-lag theory for the transfer of elastic stress between the matrix and fibers with tapered ends. This paper is a positive step towards comprehending the mechanics of the ECM and makes a valuable contribution to formulating a complete theory of collagen fibril reinforcement in the ECM.
Mannoheptulose is a seven-carbon sugar. It is an inhibitor of glucose-induced insulin secretion due to its ability to selectively inhibit the enzyme glucokinase. An improved procedure for mannoheptulose isolation from avocados is described in this study (based upon the original method by La Forge). The study focuses on the combination of biotransformation and downstream processing (preparative chromatography) as an efficient method to produce a pure extract of mannoheptulose. The experiments were divided into two major phases. In the first phase, several methods and parameters were compared to optimize the mannoheptulose extraction with respect to efficiency and purity. In the second phase, a mass balance of mannoheptulose over the whole extraction process was undertaken to estimate the yield and efficiency of the total extraction process. The combination of biotransformation and preparative chromatography allowed the production of a pure mannoheptulose extract. In a biological test, the sugar inhibited the glucokinase enzyme activity efficiently.
Real-time and reliable monitoring of the biogas process is crucial for a stable and efficient operation of biogas production in order to avoid digester breakdowns. The concentration of dissolved hydrogen (H₂) represents one of the key parameters for biogas process control. In this work, a one-chip integrated combined amperometric/field-effect sensor for monitoring the dissolved H₂ concentration has been developed for biogas applications. The combination of two different transducer principles might allow a more accurate and reliable measurement of dissolved H₂ as an early warning indicator of digester failures. The feasibility of the approach has been demonstrated by simultaneous amperometric/field-effect measurements of dissolved H₂ concentrations in electrolyte solutions. Both, the amperometric and the field-effect transducer show a linear response behaviour in the H₂ concentration range from 0.1 to 3% (v/v) with a slope of 198.4 ± 13.7 nA/% (v/v) and 14.9 ± 0.5 mV/% (v/v), respectively.
Kawasaki Heavy Industries, Ltd. (KHI), Aachen University of Applied Sciences, and B&B-AGEMA GmbH have investigated the potential of low NOx micro-mix (MMX) hydrogen combustion and its application to an industrial gas turbine combustor. Engine demonstration tests of a MMX combustor for the M1A-17 gas turbine with a co-generation system were conducted in the hydrogen-fueled power generation plant in Kobe City, Japan.
This paper presents the results of the commissioning test and the combined heat and power (CHP) supply demonstration. In the commissioning test, grid interconnection, loading tests and load cut-off tests were successfully conducted. All measurement results satisfied the Japanese environmental regulation values. Dust and soot as well as SOx were not detected. The NOx emissions were below 84 ppmv at 15 % O2. The noise level at the site boundary was below 60 dB. The vibration at the site boundary was below 45 dB.
During the combined heat and power supply demonstration, heat and power were supplied to neighboring public facilities with the MMX combustion technology and 100 % hydrogen fuel. The electric power output reached 1800 kW at which the NOx emissions were 72 ppmv at 15 % O2, and 60 %RH. Combustion instabilities were not observed. The gas turbine efficiency was improved by about 1 % compared to a non-premixed type combustor with water injection as NOx reduction method. During a total equivalent operation time of 1040 hours, all combustor parts, the M1A-17 gas turbine as such, and the co-generation system were without any issues.