Conference Proceeding
Refine
Year of publication
Document Type
- Conference Proceeding (1620) (remove)
Language
- English (1146)
- German (472)
- Multiple languages (1)
- Spanish (1)
Keywords
- Biosensor (25)
- Blitzschutz (15)
- CAD (11)
- Finite-Elemente-Methode (11)
- civil engineering (11)
- Bauingenieurwesen (10)
- Lightning protection (9)
- Einspielen <Werkstoff> (6)
- Telekommunikationsmarkt (6)
- shakedown analysis (6)
- Enterprise Architecture (5)
- Gamification (5)
- Graduiertentagung (5)
- Leadership (5)
- Clusterion (4)
- Energy storage (4)
- Führung (4)
- Kanalisation (4)
- Limit analysis (4)
- Natural language processing (4)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (296)
- Fachbereich Energietechnik (259)
- Fachbereich Medizintechnik und Technomathematik (239)
- Fachbereich Maschinenbau und Mechatronik (207)
- Fachbereich Luft- und Raumfahrttechnik (203)
- Solar-Institut Jülich (167)
- IfB - Institut für Bioengineering (151)
- Fachbereich Bauingenieurwesen (137)
- Fachbereich Wirtschaftswissenschaften (68)
- ECSM European Center for Sustainable Mobility (57)
- INB - Institut für Nano- und Biotechnologien (52)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (48)
- Fachbereich Chemie und Biotechnologie (34)
- Nowum-Energy (22)
- Kommission für Forschung und Entwicklung (16)
- Fachbereich Architektur (13)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (10)
- FH Aachen (7)
- Fachbereich Gestaltung (4)
- IaAM - Institut für angewandte Automation und Mechatronik (3)
In the past, CSP and PV have been seen as competing technologies. Despite massive reductions in the electricity generation costs of CSP plants, PV power generation is - at least during sunshine hours - significantly cheaper. If electricity is required not only during the daytime, but around the clock, CSP with its inherent thermal energy storage gets an advantage in terms of LEC. There are a few examples of projects in which CSP plants and PV plants have been co-located, meaning that they feed into the same grid connection point and ideally optimize their operation strategy to yield an overall benefit. In the past eight years, TSK Flagsol has developed a plant concept, which merges both solar technologies into one highly Integrated CSP-PV-Hybrid (ICPH) power plant. Here, unlike in simply co-located concepts, as analyzed e.g. in [1] – [4], excess PV power that would have to be dumped is used in electric molten salt heaters to increase the storage temperature, improving storage and conversion efficiency. The authors demonstrate the electricity cost sensitivity to subsystem sizing for various market scenarios, and compare the resulting optimized ICPH plants with co-located hybrid plants. Independent of the three feed-in tariffs that have been assumed, the ICPH plant shows an electricity cost advantage of almost 20% while maintaining a high degree of flexibility in power dispatch as it is characteristic for CSP power plants. As all components of such an innovative concept are well proven, the system is ready for commercial market implementation. A first project is already contracted and in early engineering execution.
Analysis Of Base Isolated Liquid Storage Tanks With 3D Fsi-Analysis As Well As Simplified Approaches
(2017)
Tanks are preferably designed, for cost-saving reasons, as circular, cylindrical, thin-walled shells. In case of seismic excitation, these constructions are highly vulnerable to stability failures. An earthquake-resistant design of rigidly supported tanks for high seismic loading demands, however, uneconomic wall thicknesses. A cost-effective alternative can be provided by base isolation systems. In this paper, a simplified seismic design procedure for base isolated tanks is introduced, by appropriately modifying the standard mechanical model for flexible, rigidly supported tanks. The non-linear behavior of conventional base isolation systems becomes an integral part of a proposed simplified process, which enables
the assessment of the reduced hydrodynamic forces acting on the tank walls and the corresponding stress distribution. The impulsive and convective actions of the liquid are taken into account. The validity of this approach is evaluated by
employing a non-linear fluid-structure interaction algorithm of finite element method. Special focus is placed on the boundary conditions imposed from the base isolation and the resulting hydrodynamic pressures. Both horizontal and vertical
component of ground motion are considered in order to study the principal effects of the base isolation on the pressure distribution of the tank walls. The induced rocking effects associated with elastomeric bearings are discussed. The results
manifest that base isolated tanks can be designed for seismic loads by means of the proposed procedure with sufficient accuracy, allowing to dispense with numerically expensive techniques.
Analysis of Big Data Streams to obtain Braking Reliability Information for Train Protection systems
(2017)
Analysis of error and time behavior of the IEEE 802.15.4 PHY-layer in an industrial environment
(2006)
Andere Primärenergiequellen
(1974)
This paper presents an approach for reducing the cognitive load for humans working in quality control (QC) for production processes that adhere to the 6σ -methodology. While 100% QC requires every part to be inspected, this task can be reduced when a human-in-the-loop QC process gets supported by an anomaly detection system that only presents those parts for manual inspection that have a significant likelihood of being defective. This approach shows good results when applied to image-based QC for metal textile products.