Article
Refine
Year of publication
Document Type
- Article (597) (remove)
Language
- English (354)
- German (241)
- Multiple languages (1)
- nld (1)
Has Fulltext
- no (597) (remove)
Keywords
- Earthquake (4)
- Antibias (1)
- Artificial intelligence (1)
- BIM (1)
- Basisisolierung (1)
- Bauwerksüberwachung (1)
- Behaviour factor q (1)
- Bemessung (1)
- Cardiovascular MRI (1)
- Civil engineering (1)
- DIN EN 1996 (1)
- Decoupling (1)
- Diversity Management (1)
- Dynamic simulation (1)
- Emilia-Romagna earthquake (1)
- Empirical consequence curves (1)
- Empirical fragility functions (1)
- Engineering Habitus (1)
- Erdbebeneinwirkung (1)
- Fracture classification (1)
Institute
- Fachbereich Energietechnik (597) (remove)
Die PIA GmbH prüft seit fast 8 Jahren die Standsicherheit von Behältern für Kleinkläranlagen. Diese bestehen in der Regel aus Kunststoff oder Beton und müssen über ihre gesamte Lebensdauer den Beanspruchungen aus Handhabung, Einbau und Betrieb standhalten. Die Standsicherheit kann nach EN 12566 wahlweise durch einen rechnerischen Nachweis oder durch einen praktischen Nachweis wie die Bruchlastprüfung oder die Prüfung in der Grube erfolgen.
Eine seismische Anregung verursacht in einem Flüssigkeitstank einen kombinierten Spannungszustand, was zu einem Stabilitätsversagen der häufig sehr dünnwandigen Konstruktionen führen kann. Für die Durchführung von Stabilitätsnachweisen stehen verschiedene Verfahren zur Verfügung. Üblicherweise werden aus Gründen der Einfachheit spannungsbasierte Verfahren angewendet. Diese sind für Einheitslastfälle experimentell abgesichert, wobei eine Übertragung auf kombinierte Spannungszustände wie im Erdbebenfall nur begrenzt möglich ist. Alternativ kann ein globales, numerisches Konzept, das LBA/MNA-Verfahren, angewendet werden. Das Verfahren kombiniert eine materiell nichtlineare Berechnung (MNA) mit einer linearen Beulanalyse (LBA) und erfasst die Interaktion verschiedener gleichzeitig auftretender Beanspruchungen implizit im Nachweis. Dieser Beitrag demonstriert die Anwendung der Verfahren am Beispiel verschiedener Tankgeometrien mit Höhe/Radius-Verhältnissen zwischen 1 ≤ H/R ≤ 2 und Radius/Tankwand-Verhältnissen zwischen 500 ≤ R/t ≤ 1000 und diskutiert zusätzlich die Defizite der spannungsbasierten Nachweisverfahren.
Speicher statt Kohle. Integration thermischer Stromspeicher in vorhandene Kraftwerksstandorte
(2019)
Solares Kochen
(1990)
Simulation and measurement of melting effects on metal sheets caused by direct lightning strikes
(1991)
Simulating the electromagnetic‐thermal treatment of thin aluminium layers for adhesion improvement
(2015)
A composite layer material used in packaging industry is made from joining layers of different materials using an adhesive. An important processing step in the production of aluminium-containing composites is the surface treatment and consequent coating of adhesive material on the aluminium surface. To increase adhesion strength between aluminium layer and the adhesive material, the foil is heat treated. For efficient heating, induction heating was considered as state-of-the-art treatment process. Due to the complexity of the heating process and the unpredictable nature of the heating source, the control of the process is not yet optimised. In this work, a finite element analysis of the process was established and various process parameters were studied. The process was simplified and modelled in 3D. The numerical model contains an air domain, an aluminium layer and a copper coil fitted with a magnetic field concentrating material. The effect of changing the speed of the aluminium foil (or rolling speed) was studied with the change of the coil current. Statistical analysis was used for generating a general control equation of coil current with changing rolling speed.
Shielding effectiveness of reinforced concrete cable ducts carrying partial lightning currents
(1998)
SHEMAT-Suite: An open-source code for simulating flow, heat and species transport in porous media
(2020)
SHEMAT-Suite is a finite-difference open-source code for simulating coupled flow, heat and species transport in porous media. The code, written in Fortran-95, originates from geoscientific research in the fields of geothermics and hydrogeology. It comprises: (1) a versatile handling of input and output, (2) a modular framework for subsurface parameter modeling, (3) a multi-level OpenMP parallelization, (4) parameter estimation and data assimilation by stochastic approaches (Monte Carlo, Ensemble Kalman filter) and by deterministic Bayesian approaches based on automatic differentiation for calculating exact (truncation error-free) derivatives of the forward code.
Semi-insulating GaAs layers grown by molecular-beam epitaxy / P. Kordos ; A. Förster ; J. Betko ...
(1995)
Mit finanzieller Unterstützung der Deutschen Gesellschaft für Mauerwerks- und Wohnungsbau e.V. (DGfM) und des Deutschen Instituts für Bautechnik in Berlin (DIBt) wurden zwei aufeinander aufbauende Forschungsvorhaben zur Verbesserung der seismischen Nachweise von Mauerwerksbauten in deutschen Erdbebengebieten durchgeführt. Zunächst wurde das seismische Verhalten von drei modernen unbewehrten Mauerwerksgebäuden in der Region Emilia Romagna in Italien während der Erdbebenserie im Jahr 2012 in Kooperation mit der Universität Pavia eingehend untersucht. Aufbauend auf den Erkenntnissen dieser Untersuchungen wurde ein verbessertes seismisches Bemessungskonzept für unbewehrte Mauerwerksbauten erarbeitet. Der Beitrag stellt die wesentlichen Ergebnisse dieser Forschungsarbeiten und deren Eingang in die Normung vor.