Refine
Year of publication
Document Type
- Article (5464)
- Conference Proceeding (1393)
- Book (1056)
- Part of a Book (544)
- Patent (172)
- Bachelor Thesis (156)
- Report (81)
- Doctoral Thesis (78)
- Other (68)
- Contribution to a Periodical (19)
- Master's Thesis (17)
- Review (17)
- Working Paper (8)
- Talk (5)
- Habilitation (4)
- Preprint (4)
- Diploma Thesis (3)
- Poster (3)
- Part of Periodical (2)
- Examination Thesis (1)
Language
Has Fulltext
- no (9096) (remove)
Keywords
- Corporate Design (9)
- Illustration (9)
- Erscheinungsbild (8)
- Gamification (8)
- Nachhaltigkeit (8)
- Redesign (7)
- Animation (6)
- Datenschutz (6)
- Digitalisierung (6)
- avalanche (6)
- App (5)
- Earthquake (5)
- Editorial (5)
- Enterprise Architecture (5)
- Fotografie (5)
- Geschichte (5)
- MINLP (5)
- solar sail (5)
- Aktionskunst (4)
- Design (4)
Institute
- Fachbereich Medizintechnik und Technomathematik (1907)
- Fachbereich Elektrotechnik und Informationstechnik (1116)
- Fachbereich Wirtschaftswissenschaften (1100)
- Fachbereich Energietechnik (1056)
- Fachbereich Chemie und Biotechnologie (829)
- Fachbereich Maschinenbau und Mechatronik (799)
- Fachbereich Luft- und Raumfahrttechnik (749)
- Fachbereich Bauingenieurwesen (658)
- IfB - Institut für Bioengineering (623)
- INB - Institut für Nano- und Biotechnologien (584)
- Solar-Institut Jülich (334)
- Fachbereich Gestaltung (333)
- Fachbereich Architektur (161)
- ECSM European Center for Sustainable Mobility (106)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (66)
- Nowum-Energy (64)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (62)
- Institut fuer Angewandte Polymerchemie (32)
- Sonstiges (24)
- IBB - Institut für Baustoffe und Baukonstruktionen (21)
- Freshman Institute (19)
- Kommission für Forschung und Entwicklung (18)
- Verwaltung (11)
- IaAM - Institut für angewandte Automation und Mechatronik (4)
- FH Aachen (3)
- IMP - Institut für Mikrowellen- und Plasmatechnik (3)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (2)
- Datenverarbeitungszentrale (1)
- Digitalisierung in Studium & Lehre (1)
Das modulare Regalsystem „MORÉ“ ist ein Stauraummöbel, welches sich im Bereich des (Home) Office einordnet. Das Produkt dient zur Aufbewahrung von Büromaterialien und verbessert die Geräuschkulisse sowie die Beschaffenheit am Arbeitsplatz. Die potenzielle Käufergruppe befindet sich im Alter von 25-67 Jahren, im gewöhnlichen Arbeitsalter Zeitraum (obere Mittelschicht). Im Fokus des Regalsystems steht der besonders freundliche Auf- und Abbau, welcher werkzeuglos erfolgt. Es ist in verschiedene Richtungen erweiterbar (Steckverbindung) und bietet unendlichen Spielraum der Gestaltung. Durch verschiedenfarbige Kennzeichnungen bietet das Regal ein Ordnungssystem, wodurch schnelleres Finden und Sortieren von Unterlagen möglich ist (Grundordnung). Die Rückwände dienen neben der Stabilität als Akustik-/ und Sichtschutz. Das Produkt passt sich jeder Raumsituation individuell an. Ist „MORÉ“ dein nächstes Regalsystem?
Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants
(2010)
Positron emitters such as 11C, 13N and 18F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is 11CO2 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET™ system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements.
Obwohl es eine Vielzahl von Einführungskonzepten für ITSM gibt, hat sich bisher keines dieser Konzepte auf breiter Linie durchgesetzt. Das gilt in erhöhtem Maße für ITSM-Einführungskonzepte für KMU, wohl nicht zuletzt aufgrund der Tatsache, dass der Mehrwert von ITSM für KMU aufgrund der geringeren Größe der IT-Organisationen nur entsprechend schwieriger generiert werden kann.
Mit diesem Beitrag wird ein Einführungskonzept für ITSM in KMU systematisch hergeleitet. Dafür wurden zunächst die Treiber und Barrieren von ITSM untersucht, um daraus ein umfassendes Wirkmodell zu entwickeln. Da mit diesem Wirkungsmodell die Einflussfaktoren auf den Erfolg von ITSM in KMU deutlich werden, konnte auf dieser Basis ein Einführungskonzept abgeleitet werden, welches insbesondere die positiven Effekte unterstützt bzw.
verstärkt.
Objective: As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to interference from electromagnetic fields (EMF) and to magneto-hydrodynamic (MHD) effects increases and with it the motivation for a CMR triggering alternative. This study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects (n=14). Methods: Quantitative analysis of 2D CINE steady-state free precession (SSFP) images was conducted to compare ACT’s performance with vector ECG (VCG). Endocardial border sharpness (EBS) was examined paralleled by quantitative LV function assessment. Results: Unlike VCG, ACT provided signal traces free of interference from EMF or MHD effects. In the case of correct Rwave recognition, VCG-triggered 2D CINE SSFP was immune to cardiac motion effects—even at 3.0 T. However, VCG-triggered 2D SSFP CINE imaging was prone to cardiac motion and EBS degradation if R-wave misregistration occurred. ACT-triggered acquisitions yielded LV parameters (end-diastolic volume (EDV), endsystolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular mass (LVM)) comparable with those derived fromVCG-triggered acquisitions (1.5 T: ESVVCG=(56± 17) ml, EDVVCG=(151±32)ml, LVMVCG=(97±27) g, SVVCG=(94± 19)ml, EFVCG=(63±5)% cf. ESVACT= (56±18) ml, EDVACT=(147±36) ml, LVMACT=(102±29) g, SVACT=(91± 22) ml, EFACT=(62±6)%; 3.0 T: ESVVCG=(55±21) ml, EDVVCG=(151±32) ml, LVMVCG=(101±27) g, SVVCG=(96±15) ml, EFVCG=(65±7)% cf. ESVACT=(54±20) ml, EDVACT=(146±35) ml, LVMACT= (101±30) g, SVACT=(92±17) ml, EFACT=(64±6)%). Conclusions: ACT’s intrinsic insensitivity to interference from electromagnetic fields renders
With a steady increase of regulatory requirements for business processes, automation support of compliance management is a field garnering increasing attention in Information Systems research. Several approaches have been developed to support compliance checking of process models. One major challenge for such approaches is their ability to handle different modeling techniques and compliance rules in order to enable widespread adoption and application. Applying a structured literature search strategy, we reflect and discuss compliance-checking approaches in order to provide an insight into their generalizability and evaluation. The results imply that current approaches mainly focus on special modeling techniques and/or a restricted set of types of compliance rules. Most approaches abstain from real-world evaluation which raises the question of their practical applicability. Referring to the search results, we propose a roadmap for further research in model-based business process compliance checking.
Given the strong increase in regulatory requirements for business processes the management of business process compliance becomes a more and more regarded field in IS research. Several methods have been developed to support compliance checking of conceptual models. However, their focus on distinct modeling languages and mostly linear (i.e., predecessor-successor related) compliance rules may hinder widespread adoption and application in practice. Furthermore, hardly any of them has been evaluated in a real-world setting. We address this issue by applying a generic pattern matching approach for conceptual models to business process compliance checking in the financial sector. It consists of a model query language, a search algorithm and a corresponding modelling tool prototype. It is (1) applicable for all graph-based conceptual modeling languages and (2) for different kinds of compliance rules. Furthermore, based on an applicability check, we (3) evaluate the approach in a financial industry project setting against its relevance for decision support of audit and compliance management tasks.
We prove characterizations of the existence of perfect ƒ-matchings in uniform mengerian and perfect hypergraphs. Moreover, we investigate the ƒ-factor problem in balanced hypergraphs. For uniform balanced hypergraphs we prove two existence theorems with purely combinatorial arguments, whereas for non-uniform balanced hypergraphs we show that the ƒ-factor problem is NP-hard.
Most drugs are no longer produced in their own countries by the pharmaceutical companies, but by contract manufacturers or at manufacturing sites in countries that can produce more cheaply. This not only makes it difficult to trace them back but also leaves room for criminal organizations to fake them unnoticed. For these reasons, it is becoming increasingly difficult to determine the exact origin of drugs. The goal of this work was to investigate how exactly this is possible by using different spectroscopic methods like nuclear magnetic resonance and near- and mid-infrared spectroscopy in combination with multivariate data analysis. As an example, 56 out of 64 different paracetamol preparations, collected from 19 countries around the world, were chosen to investigate whether it is possible to determine the pharmaceutical company, manufacturing site, or country of origin. By means of suitable pre-processing of the spectra and the different information contained in each method, principal component analysis was able to evaluate manufacturing relationships between individual companies and to differentiate between production sites or formulations. Linear discriminant analysis showed different results depending on the spectral method and purpose. For all spectroscopic methods, it was found that the classification of the preparations to their manufacturer achieves better results than the classification to their pharmaceutical company. The best results were obtained with nuclear magnetic resonance and near-infrared data, with 94.6%/99.6% and 98.7/100% of the spectra of the preparations correctly assigned to their pharmaceutical company or manufacturer.