Refine
Year of publication
Document Type
- Article (1578)
- Conference Proceeding (239)
- Book (96)
- Part of a Book (59)
- Doctoral Thesis (27)
- Patent (17)
- Report (15)
- Other (8)
- Habilitation (4)
- Lecture (3)
- Preprint (3)
- Course Material (1)
- Review (1)
- Talk (1)
Keywords
- Biosensor (25)
- Finite-Elemente-Methode (16)
- CAD (15)
- civil engineering (14)
- Bauingenieurwesen (13)
- Einspielen <Werkstoff> (13)
- shakedown analysis (9)
- FEM (6)
- Limit analysis (6)
- Shakedown analysis (6)
- limit analysis (6)
- Clusterion (5)
- Air purification (4)
- Einspielanalyse (4)
- Hämoglobin (4)
- LAPS (4)
- Lipopolysaccharide (4)
- Luftreiniger (4)
- Natural language processing (4)
- Plasmacluster ion technology (4)
- Raumluft (4)
- Shakedown (4)
- Technische Mechanik (4)
- Traglast (4)
- Traglastanalyse (4)
- hydrogen peroxide (4)
- shakedown (4)
- CellDrum (3)
- Field-effect sensor (3)
- Information extraction (3)
- Kohlenstofffaser (3)
- Label-free detection (3)
- Light-addressable potentiometric sensor (3)
- Paired sample (3)
- Sonde (3)
- biosensor (3)
- biosensors (3)
- impedance spectroscopy (3)
- lipopolysaccharides (3)
- ratchetting (3)
- Analytischer Zulaessigkeitsnachweis (2)
- Architektur (2)
- Bacillus atrophaeus (2)
- Biocomposites (2)
- Bruchmechanik (2)
- Capacitive field-effect sensor (2)
- Clustering (2)
- Druckbeanspruchung (2)
- Druckbehälter (2)
- Druckbelastung (2)
- Einspiel-Analyse (2)
- Eisschicht (2)
- Empirical process (2)
- Erythrozyt (2)
- Fehlerstellen (2)
- Fibroblast (2)
- Force (2)
- Goodness-of-fit test (2)
- Incomplete data (2)
- Independence test (2)
- Iterative learning control (2)
- Machine learning (2)
- Natural fibres (2)
- Parametric bootstrap (2)
- Pflanzenphysiologie (2)
- Pflanzenscanner (2)
- Polymer-matrix composites (2)
- Potentiometry (2)
- Raman spectroscopy (2)
- Ratcheting (2)
- Rohr (2)
- Rohrbruch (2)
- Stahl (2)
- Stickstoffmonoxid (2)
- Stiffness (2)
- Stress concentrations (2)
- Tobacco mosaic virus (TMV) (2)
- acetoin (2)
- architecture (2)
- biopotential electrodes (2)
- burst pressure (2)
- burst tests (2)
- capacitive field-effect sensors (2)
- carbonized rice husk (2)
- celldrum technology (2)
- constructive alignment (2)
- damage (2)
- examination (2)
- field-effect sensor (2)
- flaw (2)
- frequency mixing magnetic detection (2)
- gas sensor (2)
- likelihood ratio test (2)
- limit load (2)
- load limit (2)
- locomotion (2)
- long-term retention (2)
- multimodal (2)
- muscle fascicle behavior (2)
- nanostructured carbonized plant parts (2)
- nanostrukturierte carbonisierte Pflanzenteile (2)
- nitric oxide gas (2)
- not identically distributed (2)
- pipes (2)
- plant scanner (2)
- practical learning (2)
- sterilisation (2)
- surface modification (2)
- tension–torsion loading (2)
- tobacco mosaic virus (TMV) (2)
- ultrasound (2)
- ultrasound imaging (2)
- vessels (2)
- (Bio)degradation (1)
- 3-nitrofluoranthene (1)
- Acceleration (1)
- Achilles tendon (1)
- Active learning (1)
- Adaptive control (1)
- Adsorption (1)
- Afterload (1)
- Ageing (1)
- Agent-based simulation (1)
- AlterG (1)
- Alternating plasticity (1)
- Alzheimer's disease (1)
- Analysis (1)
- Anastomose (1)
- Anastomosis (1)
- Anastomotic leakage (1)
- Anatomy (1)
- Annulus Fibrosus (1)
- Architectural design (1)
- Architectural gear ratio (1)
- Arthosetherapie (1)
- Assistive technology (1)
- Asymptotic efficiency (1)
- Asymptotic relative efficiency (1)
- Aufschlagversuch (1)
- Autofluoreszenzverfahren (1)
- Autolysis (1)
- Automatic control (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- BTEX compounds (1)
- Bacillus atrophaeus spores (1)
- Bacillus sp (1)
- Bacterial cellulose (1)
- Bakterien (1)
- Balance (1)
- Basis Reduktion (1)
- Basis reduction (1)
- Bein (1)
- Bicharakteristikenverfahren (1)
- Bio-Sensors (1)
- Bioabsorbable (1)
- Biomechanical simulation (1)
- Biomechanics (1)
- Biomechanik (1)
- Biomedizinische Technik (1)
- Biomolecular logic gate (1)
- Biophoton (1)
- Bioreaktor (1)
- Biosensorik (1)
- Biosolubilization (1)
- Bladder (1)
- Blitzschutz (1)
- Blutzellenlagerung (1)
- Bone quality and biomechanics (1)
- Bone sawing (1)
- Booster Station (1)
- Bootstrap (1)
- Bootstrapping (1)
- Brennkraftmaschine (1)
- Brennstoffeinspritzsystem (1)
- Brownian Pillow (1)
- CAD ; (1)
- CNOT (1)
- CO (1)
- Calorimetric gas sensor (1)
- Capacitive field-effect (1)
- Capacitive model (1)
- Carbon sources (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- Categorial variable (1)
- Cell permeability (1)
- Cellular force (1)
- Cellulose nanostructure (1)
- Cement infiltration (1)
- Cementoblast (1)
- Censored data (1)
- Chance constrained programming (1)
- Chemical images (1)
- Chemical imaging (1)
- Chemical imaging sensor (1)
- Chemical sensor (1)
- Choleratoxin B (1)
- Circular Dichroism (1)
- Cloud Computing (1)
- Cloud Service Broker (1)
- Co-managed care (1)
- Coat protein (1)
- Coefficient of ocular rigidity (1)
- Collective risk model (1)
- Competitiveness (1)
- Complex System (1)
- Complex-valued eigenvalues (1)
- Compliance (1)
- Compression (1)
- Computational biomechanics (1)
- Concomitant (1)
- Conducing polymer (1)
- Conductive Boundary Condition (1)
- Constitutive model (1)
- Contractile tension (1)
- Contractility (1)
- Convex optimization (1)
- Corneo-scleral shell (1)
- Cost-effectiveness (1)
- Coverage probability (1)
- Cramér-von-Mises statistic (1)
- Cramér-von-Mises test (1)
- Cross border adjustment mechanism (1)
- Crámer–von-Mises distance (1)
- Culture media (1)
- C–V method (1)
- DNA (1)
- DNA biosensor (1)
- DNA hybridization (1)
- DPA (dipicolinic acid) (1)
- Damage mechanics theory (1)
- Dattel (1)
- Decomposition (1)
- Deep Learning (1)
- Deep learning (1)
- Deformation (1)
- Dehydrogenase (1)
- Dekontamination (1)
- Design-by-analysis (1)
- Diaphorase (1)
- Differential tonometry (1)
- Disc Degeneration (1)
- Discontinuous fractures (1)
- Discrete Optimization (1)
- Distorsion des oberen Sprunggelenks (1)
- Druckgeräte (1)
- Drug simulation (1)
- Dry surfaces (1)
- E-Mobility (1)
- ECT (1)
- EEG (1)
- EIS capacitive sensor (1)
- ELISA (1)
- EPN (1)
- ES-FEM (1)
- Effizienz (1)
- Eigenvalue trajectories (1)
- Einspiel-Kriterium (1)
- Einspielen (1)
- Elastizität (1)
- Elastodynamik (1)
- Elastostatics (1)
- Elderly (1)
- Electrolyte–insulator–semiconductor (1)
- Electromagnetism (1)
- Electromechanical modeling (1)
- Elektrodynamik (1)
- Elektroenzephalographie (1)
- Elektromyographie (1)
- Elektrostimulation (1)
- Elemental (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Endothelial dysfunction (1)
- Endothelzelle (1)
- Energy market design (1)
- Energy-intensive industry (1)
- Enterprise information systems (1)
- Environmental impact (1)
- Enzymatic biosensor (1)
- Enzyme biosensor (1)
- Enzyme coverage (1)
- Enzyme logic gate (1)
- Enzyme nanocarrier (1)
- Enzyme-linked immunosorbent assay (1)
- Epithel (1)
- Equivalence test (1)
- Esophageal Doppler monitor (1)
- Evolution of damage (1)
- Exact Ilyushin yield surface (1)
- Experiment (1)
- Extension fracture (1)
- Extension strain criterion (1)
- Extensor (1)
- External knee adduction moments (1)
- Eyeball (1)
- FEM-Programm (1)
- FEM-computation (1)
- FGF23 (1)
- FS-FEM (1)
- Fall prevention (1)
- Fault approximation (1)
- Fault detection (1)
- Festkörper (1)
- Field effect (1)
- Field-effect biosensor (1)
- Field-effect device (1)
- Finite element analysis (1)
- Finite element analysis (FEA) (1)
- Finite element method (1)
- Finite element modelling (1)
- First Order Reliabiblity Method (1)
- First-order reliability method (1)
- Fließgrenze (1)
- Floor prices (1)
- Fluorescence (1)
- Forces (1)
- Fracture configuration (1)
- Fracture simulation (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Frequency mixing magnetic detection (1)
- Functional Delta Method (1)
- Fußball (1)
- GaAs hot electron injector (1)
- Gamma distribution (1)
- Gas sensor (1)
- Geriatric (1)
- German (1)
- Glaucoma (1)
- Global and local collapse (1)
- Glucose biosensor (1)
- Glucose oxidase (1)
- Gold nanoparticle (1)
- Gold nanoparticles (1)
- Gonarthrose (1)
- Goodness-of-fit tests for uniformity (1)
- Grenzwertberechnung (1)
- Grid Computing (1)
- Ground-level falls (1)
- Growth modelling (1)
- Gunn diode (1)
- Hadamard differentiability (1)
- Haemodialysis (1)
- Handbike (1)
- Harnleiter (1)
- Heart tissue culture (1)
- Heavy metal detection (1)
- Hemoglobin structure (1)
- Heterostructure (1)
- High throughput experimentation (1)
- Hip fractures (1)
- Hodgkin–Huxley models (1)
- Hoeffding-Blum-Kiefer-Rosenblatt independence test (1)
- Homogenization (1)
- Hotelling’s T² test (1)
- Hotplate (1)
- Human Factors (1)
- Human-Computer interaction (1)
- Hydrodynamik (1)
- Hydrogel (1)
- Hydrogen peroxide (1)
- Hydrogen sensor (1)
- Hypothesentests (1)
- Hämoglobinstruktur (1)
- I3S 2005 (1)
- ISFET (1)
- Image Reconstruction (1)
- Impedance Spectroscopy (1)
- Impedance spectroscopy (1)
- Induced pluripotent stem cells (1)
- Information Extraction (1)
- Information Integration Tools (1)
- Inotropic compounds (1)
- Integrated empirical distribution (survival) function (1)
- Interior transmission problem (1)
- International Symposium on Sensor Science (1)
- Intervertebral Disc (1)
- Intradiscal Pressure (1)
- Inverse Scattering (1)
- Inverse dynamic problem (1)
- Inverse kinematic problem (1)
- Inverse scattering problem (1)
- Ion channels (1)
- Kinematics (1)
- Kinetic energy (1)
- Kinetics (1)
- Klotho (1)
- Knee (1)
- Kniegelenkarthrose (1)
- Knochen (1)
- Knochenbildung (1)
- Knochenchirugie (1)
- Knochendichte (1)
- Knowledge Management (1)
- Krypton (1)
- Krypton-85 (1)
- Körpertemperatur (1)
- LED chip (1)
- LISA (1)
- LPS (1)
- Lab-on-Chip (1)
- Langevin theory (1)
- Layer-by-layer adsorption (1)
- LbL films (1)
- Level sensor (1)
- Lichtstreuungsbasierte Instrumente (1)
- Light-addressable Potentiometric Sensor (1)
- Liver (1)
- Load modeling (1)
- Long COVID (1)
- MBST (1)
- MCDA (1)
- MEMS (1)
- MOS (1)
- Magnetic nanoparticles (1)
- Main sensitivity (1)
- Manipulated variables (1)
- Marginal homogeneity (1)
- Marginal homogeneity test (1)
- Market modeling (1)
- Materialermüdung (1)
- Mechanical simulation (1)
- Mechanics (1)
- Mechanische Beanspruchung (1)
- Mechanotransduction (1)
- Medusomyces gisevi (1)
- Metascintillator (1)
- Microbial adhesion (1)
- Microcirculation (1)
- Micromagnetic simulation (1)
- Microreactors (1)
- Mild cognitive impairment (1)
- Mobility (1)
- Mobility tests (1)
- Mobility transition (1)
- Model-driven software engineering (1)
- Mohr–Coulomb criterion (1)
- Multi-criteria decision analysis (1)
- Multi-dimensional wave propagation (1)
- Multi-sample problem (1)
- Multianalyte detection (1)
- Multicell (1)
- Multimode failure (1)
- Multiple TOF kernels (1)
- Multiplexing (1)
- Muscle (1)
- Muscle Fascicle (1)
- Muscle Force (1)
- Muscle fibers (1)
- Musculoskeletal model (1)
- Musculoskeletal system (1)
- Myocardial infarction and cardiac death (1)
- NONOate (1)
- Nano Materials (1)
- Nanomaterial (1)
- Nanoparticles (1)
- Nanopartikel (1)
- Nanostructuring (1)
- Nanotechnologie (1)
- Nanotechnology ; Microelectronics ; Biosensors ; Superconductor ; MEMS (1)
- Natriumhypochlorit (1)
- Natural Language Processing (1)
- Natural language understanding (1)
- Negative impedance convertor (1)
- Neural Network (1)
- Neuromuskuläres System (1)
- Niacin (1)
- Nichtlineare Gleichung (1)
- Nichtlineare Optimierung (1)
- Nichtlineare Welle (1)
- Nitric Oxide (1)
- Nitric Oxide Donor (1)
- Non-linear optimization (1)
- Non-parallel fissures (1)
- Nonequilibrium dynamics (1)
- Nonlinear Dynamics (1)
- Nucleus Pulposus (1)
- Numerical inversion of Laplace transforms (1)
- Numerical linear algebra (1)
- O2 plasma (1)
- Ocular blood flow (1)
- Ontologie <Wissensverarbeitung> (1)
- Ontology Engineering (1)
- Organic light-emitting diode display (1)
- Organkultur (1)
- Organophosphorus (1)
- Ostazine Orange (1)
- Osteoporose (1)
- Osteoporosis (1)
- PFM (1)
- PTH (1)
- Paralympic sport (1)
- Passive stretching (1)
- Pelvic floor dysfunction (1)
- Pelvic muscle (1)
- Penicillin (1)
- Permeability (1)
- Permeabilität (1)
- Peroxidase (1)
- Pflanzenstress (1)
- Pharmacology (1)
- Phenylalanine determination (1)
- Phosphate (1)
- Physiology (1)
- Plant virus (1)
- Plastizität (1)
- Poly(allylamine hydrochloride) (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Polylactide acid (1)
- Post-COVID-19 syndrome (1)
- Preference assessment (1)
- Pressure loaded crack-face (1)
- Pressure-volume relationship (1)
- Prevention (1)
- Process model (1)
- Product-integration (1)
- Profile Extraction (1)
- Profile extraction (1)
- Progressive plastic deformation (1)
- Prophylaxis (1)
- Proteine (1)
- Proximal humerus fracture (1)
- Pseudomonas putida (1)
- Psychiatrische Biomarker (1)
- Pulsations (1)
- Pump System (1)
- Quartz crystal nanobalance (QCN) (1)
- Quartz micro balances (1)
- Query learning (1)
- RVA (1)
- Random variable (1)
- Ratchetting (1)
- Raumfahrt (1)
- Reaction-diffusion (1)
- Real-time monitoring (1)
- Recombinant activated protein C (1)
- Reconstruction (1)
- Red blood cell storage (1)
- Regionalization (1)
- Rehabilitation Technology and Prosthetics (1)
- Rehabilitation engineering (1)
- Rehabilitationsmedizin (1)
- Rehabilitatives Training (1)
- Relation classification (1)
- Reliability analysis (1)
- Reliability of structures (1)
- Reproducible research (1)
- Resampling test (1)
- Resistive temperature detector (1)
- Resolvent Operator (1)
- Resonance-mode measurement (1)
- Retinal vessel analysis (1)
- Retinal vessels (1)
- Riboflavin (1)
- Robotic rehabilitation (1)
- Robotik (1)
- Rotator cuff (1)
- Running (1)
- S-FEM (1)
- Sampling methods (1)
- ScaLAPACK (1)
- Schienbeinschoner (1)
- Schlafspindeldetektion (1)
- Schwammknochen (1)
- Semi-parametric random censorship model (1)
- Sensitivity (1)
- Sepsis (1)
- Septic cardiomyopathy (1)
- Shakedown criterion (1)
- Silk fibroin (1)
- Simulation (1)
- Simultaneous determination (1)
- Skeletal muscle (1)
- Sleep EEG (1)
- Small Aral Sea (1)
- Sn₃O₄ (1)
- Software and systems modeling (1)
- Solid amalgam electrodes (1)
- Spleen (1)
- Sprunggelenkorthesen (1)
- Statics (1)
- Steel industry (1)
- Sterilisation process (1)
- Stochastic programming (1)
- Strukturanalyse (1)
- SunRav BookEditor (1)
- Supraleiter (1)
- Surface microorganisms (1)
- Surgical Navigation and Robotics (1)
- Surgical staplers (1)
- Survival analysis (1)
- Swabbing (1)
- TMV adsorption (1)
- TOF PET (1)
- Ta₂O₅ gate (1)
- Technical Operations Research (TOR) (1)
- Temperaturabhängigkeit (1)
- Tendon Rupture (1)
- Tendon properties (1)
- Tendons (1)
- Tension (1)
- Text Mining (1)
- Text mining (1)
- Thiamine (1)
- Tin oxide (1)
- Tinetti test (1)
- Tissue Engineering (1)
- Tobacco mosaic virus (1)
- Torsion (1)
- Torsionsbelastung (1)
- Tragfähigkeit (1)
- Training (1)
- Trainingsgerät (1)
- Transmission Eigenvalues (1)
- Trinkwassersicherheit (1)
- Trustworthy artificial intelligence (1)
- UML (1)
- Ultrasound (1)
- Uniaxial compression test (1)
- Unified Modeling Language (1)
- Ureter (1)
- Vapnik–Čhervonenkis class (1)
- Variable height stapler design (1)
- Vascular response (1)
- Vasomotions (1)
- Velocity (1)
- Vergleich von Experimenten (1)
- Vertebroplastie (1)
- Vertebroplasty (1)
- Viscous flow (1)
- Viskose Strömung (1)
- Viskosität (1)
- Visual field asymmetry (1)
- Vitamin A (1)
- Vitamin B (1)
- Vitamin D (1)
- Volterra integral equation (1)
- Volume of confidence regions (1)
- Volume status (1)
- Volumes of confidence regions (1)
- Wafer (1)
- Wasserbrücke (1)
- Wasserstoffperoxid (1)
- Wellen (1)
- Wolff's Law (1)
- Wolffsches Gesetz (1)
- Workflow (1)
- Workflow Orchestration (1)
- Wundheilung (1)
- XOR (1)
- Xenon (1)
- Zeta potential (1)
- Zug-Druck Belastung (1)
- Zug-Druck-Beanspruchung (1)
- Zug-Druck-Belastung (1)
- acetoin reductase (1)
- achilles tendon (1)
- actin cytoskeleton (1)
- activated nanostructured carbon (1)
- adipose-derived stromal cells (ASCs) (1)
- adsorption (1)
- agility (1)
- aktivierte nanostrukturierte Kohlenstofffaser (1)
- alcoholic beverages (1)
- allocation (1)
- alternierend Verformbarkeit (1)
- ammonia gas sensors (1)
- amperometric biosensors (1)
- amperometric sensor (1)
- anaesthetic complications (1)
- anisotropy (1)
- ankle braces (1)
- ankle sprain (1)
- annealing (1)
- antimony doped tin oxide (1)
- aortic perfusion (1)
- aromatic amines (1)
- arthrosis therapy (1)
- artificial olfactory image (1)
- asymptotic relative efficiency (1)
- atomic layer deposition (1)
- autofluorescence-based detection system (1)
- barium strontium titanate (1)
- biaxial tensile experiment (1)
- bicharacteristics (1)
- bioburdens (1)
- biocompatible (1)
- biocompatible materials (1)
- biodegradabl (1)
- biodegradable electronic devices (1)
- biomechanics (1)
- bone density (1)
- bone structure (1)
- bootstrap (1)
- calorimetric gas sensor (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- cancellous bone (1)
- capacitive electrolyte–insulator–semiconductor sensors (1)
- capacitive field-effect biosensor (1)
- capacitive field-effect sensor (1)
- capillary micro-droplet cell (1)
- carbon electrodes (1)
- carcinogens (1)
- cardiomyocyte biomechanics (1)
- catalytic decomposition (1)
- catalytic metal (1)
- cell aerosolization (1)
- cell atomization (1)
- central symmetry test (1)
- cerebral small vessel disease (1)
- chance constrained programming (1)
- chemical reduction method (1)
- chemical sensor (1)
- cholera toxin B (1)
- cognitive impairment (1)
- community dwelling (1)
- complete block symmetry (1)
- computational fluid dynamics analysis (1)
- conditional excess distribution (1)
- conditional expectation principle (1)
- confidence interval (1)
- connective tissue (1)
- constitutive modeling (1)
- contactless conductivity sensor (1)
- contractile tension (1)
- correlation (1)
- coupled Néel–Brownian relaxation dynamics (1)
- covariance principle (1)
- cross sensitivity (1)
- cytosolic water diffusion (1)
- date palm tree (1)
- dental trauma (1)
- design-by-analysis (1)
- dialysis (1)
- difficult airway (1)
- direct method (1)
- distance learning (1)
- distorted element (1)
- doped metal oxide (1)
- doped silicon (1)
- doping (1)
- double-lumen tube intubation (1)
- drinking water safety (1)
- drop jump (1)
- e-books (1)
- e-issues (1)
- ecological structure (1)
- efficiency (1)
- eigensolvers (1)
- elastic solids (1)
- electrical capacitance tomography (1)
- electro-migration (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- electromyography (1)
- electronic nose (1)
- electronic noses dendronized polymers inverted mesa technology (1)
- encapsulation materials (1)
- endoluminal (1)
- endospores (1)
- energy absorption (1)
- energy dissipation (1)
- enzymatic (bio)degradation (1)
- enzymatic biosensor (1)
- enzymatic methods (1)
- enzyme cascade (1)
- enzyme immobilisation (1)
- enzyme immobilization (1)
- epithelization (1)
- exchangeability test (1)
- extracorporeal membrane oxygenation (1)
- fatigue analyses (1)
- fenitrothion (1)
- fibroin (1)
- fibulare Bandruptur (1)
- field-effect structure (1)
- finite element analysis (1)
- fluidic (1)
- force generation (1)
- forecast (1)
- forehead EEG (1)
- fortschreitende plastische Deformation (1)
- frequency mixing (1)
- functional data (1)
- gait (1)
- gas sensor array (1)
- glucose (1)
- glucose oxidase (GOx) (1)
- gonarthrosis (1)
- goodness-of-fit test (1)
- graphene oxide (1)
- healthy aging (1)
- heater metallisation (1)
- heavy metals (1)
- hemoglobin (1)
- hemoglobin dynamics (1)
- hiPS cardiomyocytes (1)
- high-intensity exercise (1)
- high-k material (1)
- high-temperature stability (1)
- horseradish peroxidase (HRP) (1)
- huge dimensional data (1)
- human dermal fibroblasts (1)
- humic acid (1)
- humidity (1)
- hydrogel (1)
- hydroxylation (1)
- hyper-gravity (1)
- hyperelastic (1)
- hypo-gravity (1)
- image sensor (1)
- imaging (1)
- immobilization (1)
- in-ear EEG (1)
- in-situ monitoring (1)
- independence test (1)
- intraclass correlation coefficient (1)
- ion-selective electrodes (1)
- key performance indicators (1)
- kontraktile Spannung (1)
- konvexe Optimierung (1)
- krypton xenon hydrate (1)
- lab-on-a-chip (1)
- lab-on-chip (1)
- lable-free detection (1)
- large language models (1)
- layer expansion (1)
- layer-by-layer technique (1)
- lenslet array (1)
- light scattering analysis (1)
- light-addressable potentiometric sensor (1)
- light-addressing technologies (1)
- lightning flash (1)
- lignite (1)
- limit and shakedown analysis (1)
- linear kinematic hardening (1)
- lipopolysaccharide (1)
- load carrying capacity (1)
- lower bound theorem (1)
- magnetic actuation (1)
- magnetic beads (1)
- magnetic biosensing (1)
- magnetic frequency mixing technique (1)
- magnetic nanoparticles (1)
- magnetic particles (1)
- magnetic relaxation (1)
- magnetic sandwich immunoassay (1)
- magnetic sensing (1)
- magnetic separation (1)
- magnetic tweezers (1)
- magnetophoretic velocity (1)
- material shakedown (1)
- matrix method (1)
- mechanical buffer (1)
- mechanical waves (1)
- metagenomics (1)
- metal oxide (1)
- metal-oxide-semiconductor structure (1)
- microbial diversity (1)
- micromagnetic simulation (1)
- microreactor (1)
- microwave generation (1)
- modeling biosensor (1)
- modelling (1)
- modified electrode (1)
- multi-functional material (1)
- multi-interface measurement (1)
- multinomial distribution (1)
- multiparametric immunoassays (1)
- multivariate normal distribution (1)
- muscle mechanics (1)
- nanobelts (1)
- nanomaterials (1)
- naphtols (1)
- nitrogen oxides (1)
- non-simplex S-FEM elements (1)
- nonlinear kinematic hardening (1)
- nonlinear optimization (1)
- nonlinear solids (1)
- nonlinear tensor constitutive equation (1)
- novel photoexcitation method (1)
- optical sensor setup (1)
- optical spore trapping (1)
- optical trapping (1)
- organic PVC membranes (1)
- organosilanes (1)
- overload (1)
- pH sensors (1)
- pH-based biosensing (1)
- parabolic flight (1)
- pattern-size reduction (1)
- penicillin (1)
- penicillinase (1)
- performance analysis (1)
- performance testing (1)
- phenols (1)
- photoelectrochemistry (1)
- physiology (1)
- plant stress (1)
- plant virus detection (1)
- plasma generated ions (1)
- plastic deformation (1)
- plug-based microfluidic device (1)
- poly(d, l-lactic acid) (1)
- polyaniline (1)
- polymer composites (1)
- porous Pt electrode (1)
- portfolio risk (1)
- prevention (1)
- principal component (1)
- probabilistic fracture mechanics (1)
- protein (1)
- psychosocial (1)
- quantum charging (1)
- random effects (1)
- random effects meta-regression model (1)
- rehabilitation (1)
- reliability (1)
- reliability analysis (1)
- reliability of structures (1)
- retinal microvasculature (1)
- retinal vessels (1)
- rhAPC (1)
- running (1)
- rupture of the fibular ligament (1)
- sEMG (1)
- sarcomere operating length (1)
- scanned light pulse technique (1)
- screen-printing (1)
- second-order reliability method (1)
- self-aligned patterning (1)
- semantic role labeling (1)
- sensing properties (1)
- sensors (1)
- separable Hilbert space (1)
- series elastic element behavior (1)
- shakedown analyses (1)
- shotgun sequencing (1)
- shoulder (1)
- silanization (1)
- simulation (1)
- smooth muscle contraction (1)
- softs (1)
- spatial resolution (1)
- speaker attribution (1)
- sprint start (1)
- standard error of measurement (1)
- sterility tests (1)
- sterilization (1)
- sterilization conditions (1)
- sterilization efficacy (1)
- sterilization methods (1)
- stiffness (1)
- stochastic programming (1)
- strain energy function (1)
- stretch reflex (1)
- stretch-shortening cycle (1)
- subsurface ice research (1)
- subsurface probe (1)
- superparamagnetic bead (1)
- superparamagnetic nanoparticles (1)
- surface functionalization (1)
- survival (1)
- swift heavy ions (1)
- temperature (1)
- tendon rupture (1)
- test-retest reliability (1)
- testing hypotheses (1)
- thermal ratcheting (1)
- thick-film technology (1)
- thin-film microsensors (1)
- tilted constant illumination (1)
- titanium dioxide photoanode (1)
- training simulator (1)
- tri-lineage differentiation (1)
- turnip vein clearing virus (TVCV) (1)
- twin-fluid atomizer (1)
- ultrasonography (1)
- ultrathin gate insulators (1)
- uniformly most powerful invariant test (1)
- unloading (1)
- validation methods (1)
- videolaryngoscopy (1)
- virgin passive (1)
- virtual reality (1)
- viscoelasticity (1)
- visualization (1)
- voltammetry (1)
- wafer-level testing (1)
- walking (1)
- walking gait (1)
- water bridge phenomenon (1)
- wound healing (1)
- yield stress (1)
- · Psychiatrische Erkrankungen/Diagnostik (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (2052) (remove)
To study chemical and biological processes, spatially resolved determination of the concentrations of one or more analyte species is of distinct interest. With a light-addressable potentiometric sensor (LAPS), chemical images can be created, which visualize the concentration distribution above the sensor plate. One important challenge is to achieve a good lateral resolution in order to detect events that take place in a small and limited region. LAPS utilizes a focused light spot to address the measurement region. By moving this light spot along the semiconductor sensor plate, the concentration distribution can be observed. In this study, we show that utilizing a pulse as light excitation instead of a traditionally used continuously modulated light excitation, the lateral resolution can be improved by a factor of 6 or more.
A light-addressable potentiometric sensor (LAPS) can measure the concentration of one or several analytes at the sensor surface simultaneously in a spatially resolved manner. A modulated light pointer stimulates the semiconductor structure at the area of interest and a responding photocurrent can be read out. By simultaneous stimulation of several areas with light pointers of different modulation frequencies, the read out can be performed at the same time. With the new proposed controller electronic based on a field-programmable gate array (FPGA), it is possible to control the modulation frequencies, phase shifts, and light brightness of multiple light pointers independently and simultaneously. Thus, it is possible to investigate the frequency response of the sensor, and to examine the analyte concentration by the determination of the surface potential with the help of current/voltage curves and phase/voltage curves. Additionally, the ability to individually change the light intensities of each light pointer is used to perform signal correction.
Semiconductor-based chemical imaging sensors, like the light-addressable potentiometric sensor (LAPS) or the pH-imaging sensor based on a charge-coupled device (CCD), are becoming a powerful tool for label-free imaging of biological phenomena. We have proposed a polyion-based enzymatic membrane to develop an acetylcholine (ACh) imaging sensor for neural cell-activity observations. In this study, a CCD-type ACh-imaging sensor and a LAPS-type ACh-imaging sensor were fabricated and the prospect of both sensors was clarified by making a comparison of their basic characteristics.
Light-addressable potentiometric sensors (LAPS) are field-effect-based sensors. A modulated light source is used to define the particular measurement spot to perform spatially resolved measurements of chemical species and to generate chemical images. In this work, an organic-LED (OLED) display has been chosen as a light source. This allows high measurement resolution and miniaturisation of the system. A new developed driving method for the OLED display optimised for LAPS-based measurements is demonstrated. The new method enables to define modulation frequencies between 1 kHz and 16 kHz and hence, reduces the measurement time of a chemical image by a factor of 40 compared to the traditional addressing of an OLED display.
Light-addressable potentiometric sensors (LAPS) are semiconductor-based potentiometric sensors, with the advantage to detect the concentration of a chemical species in a liquid solution above the sensor surface in a spatially resolved manner. The addressing is achieved by a modulated and focused light source illuminating the semiconductor and generating a concentration-depending photocurrent. This work introduces a LAPS set-up that is able to monitor the electrical impedance in addition to the photocurrent. The impedance spectra of a LAPS structure, with and without illumination, as well as the frequency behaviour of the LAPS measurement are investigated. The measurements are supported by electrical equivalent circuits to explain the impedance and the LAPS-frequency behaviour. The work investigates the influence of different parameters on the frequency behaviour of the LAPS. Furthermore, the phase shift of the photocurrent, the influence of the surface potential as well as the changes of the sensor impedance will be discussed.
Glucose oxidase (GOx) is an enzyme frequently used in glucose biosensors. As increased temperatures can enhance the performance of electrochemical sensors, we investigated the impact of temperature pulses on GOx that was drop-coated on flattened Pt microwires. The wires were heated by an alternating current. The sensitivity towards glucose and the temperature stability of GOx was investigated by amperometry. An up to 22-fold increase of sensitivity was observed. Spatially resolved enzyme activity changes were investigated via scanning electrochemical microscopy. The application of short (<100 ms) heat pulses was associated with less thermal inactivation of the immobilized GOx than long-term heating.
Ein 34-jähriger männlicher Patient stellte sich zur Abklärung einer seit dem 9. Lebensjahr bestehenden und im letzten Jahr rasch progredienten Visusminderung beider Augen bei uns vor. Er beschrieb eine subjektiv zunehmende, im Spiegel für ihn selbst sichtbare, weißliche Trübung in der Pupille beidseits und eine starke Blendempfindlichkeit. Nebenbefundlich gab er rezidivierende Konjunktivitiden und morgens verklebte Lider an. Eine Allergie auf Gräserpollen und eine Unverträglichkeit auf Alkohol sowie mehrere Lebensmittel seien ebenfalls bekannt.
Zusätzlich leidet der Patient an stark ausgeprägtem atopischem Ekzem. Dieses wurde nie systemisch, sondern nur bei Bedarf mit kortisonhaltiger Salbe therapiert.
DNA-hybridization detection using light-addressable potentiometric sensor modified with gold layer
(2014)
A multi-spot (4 × 4 spots) light-addressable potentiometric sensor (MLAPS) consisting of an Al–p-Si–SiO2 structure has been applied for the label-free electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge for the first time. Single-stranded probe ssDNA molecules (20 bases) were covalently immobilized onto the silanized SiO2 gate surface. The unspecific adsorption of mismatch ssDNA on the MLAPS gate surface was blocked by bovine serum albumin molecules. To reduce the screening effect and to achieve a high sensor signal, the measurements were performed in a low ionic-strength solution. The photocurrent–voltage (I–V) curves were simultaneously recorded on all 16 spots after each surface functionalization step. Large shifts of I–V curves of 25 mV were registered after the DNA immobilization and hybridization event. In contrast, a small potential shift (∼5 mV) was observed in case of mismatch ssDNA, revealing good specificity of the sensor. The obtained results demonstrate the potential of the MLAPS as promising transducer platform for the multi-spot label-free electrical detection of DNA molecules by their intrinsic molecular charge.
A multi-spot (16 spots) light-addressable potentiometric sensor (MLAPS) consisting of an Al–p-Si–SiO2 structure modified with a weak polyelectrolyte layer of PAH (poly(allylamine hydrochloride)) was applied for the label-free electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge for the first time. To achieve a preferentially flat orientation of DNA strands and thus, to reduce the distance between the DNA charge and MLAPS surface, the negatively charged probe single-stranded DNAs (ssDNA) were electrostatically adsorbed onto the positively charged PAH layer using a simple layer-by-layer (LbL) technique. In this way, more DNA charge can be positioned within the Debye length, yielding a higher sensor signal. The surface potential changes in each spot induced due to the surface modification steps (PAH adsorption, probe ssDNA immobilization, hybridization with complementary target DNA (cDNA), non-specific adsorption of mismatched ssDNA) were determined from the shifts of photocurrent–voltage curves along the voltage axis. A high sensor signal of 83 mV was registered after immobilization of probe ssDNA onto the PAH layer. The hybridization signal increases from 5 mV to 32 mV with increasing the concentration of cDNA from 0.1 nM to 5 μM. In contrast, a small signal of 5 mV was recorded in the case of non-specific adsorption of fully mismatched ssDNA (5 μM). The obtained results demonstrate the potential of the MLAPS in combination with the simple and rapid LbL immobilization technique as a promising platform for the future development of multi-spot light-addressable label-free DNA chips with direct electrical readout.
A multi-spot light-addressable potentiometric sensor (LAPS), which belongs to the family of semiconductor field-effect devices, was applied for label-free detection of double-stranded deoxyribonucleic acid (dsDNA) molecules by their intrinsic molecular charge. To reduce the distance between the DNA charge and sensor surface and thus, to enhance the electrostatic coupling between the dsDNA molecules and the LAPS, the negatively charged dsDNA molecules were electrostatically adsorbed onto the gate surface of the LAPS covered with a positively charged weak polyelectrolyte layer of PAH (poly(allylamine hydrochloride)). The surface potential changes in each spot of the LAPS, induced by the layer-by-layer adsorption of a PAH/dsDNA bilayer, were recorded by means of photocurrent-voltage and constant-photocurrent measurements. In addition, the surface morphology of the gate surface before and after consecutive electrostatic adsorption of PAH and dsDNA layers was studied by atomic force microscopy measurements. Moreover, fluorescence microscopy was used to verify the successful adsorption of dsDNA molecules onto the PAH-modified LAPS surface. A high sensor signal of 25 mV was registered after adsorption of 10 nM dsDNA molecules. The lower detection limit is down to 0.1 nM dsDNA. The obtained results demonstrate that the PAH-modified LAPS device provides a convenient and rapid platform for the direct label-free electrical detection of in-solution hybridized dsDNA molecules.
An application of a scanning light-addressable potentiometric sensor for label-free DNA detection
(2013)
The light-addressable potentiometric sensor (LAPS) and scanning photo-induced impedance microscopy (SPIM) are two closely related methods to visualise the distributions of chemical species and impedance, respectively, at the interface between the sensing surface and the sample solution. They both have the same field-effect structure based on a semiconductor, which allows spatially resolved and label-free measurement of chemical species and impedance in the form of a photocurrent signal generated by a scanning light beam. In this article, the principles and various operation modes of LAPS and SPIM, functionalisation of the sensing surface for measuring various species, LAPS-based chemical imaging and high-resolution sensors based on silicon-on-sapphire substrates are described and discussed, focusing on their technical details and prospective applications.
The light-addressable potentiometric sensor (LAPS) is an electrochemical sensor with a field-effect structure to detect the variation of the Nernst potential at its sensor surface, the measured area on which is defined by illumination. Thanks to this light-addressability, the LAPS can be applied to chemical imaging sensor systems, which can visualize the two-dimensional distribution of a particular target ion on the sensor surface. Chemical imaging sensor systems are expected to be useful for analysis of reaction and diffusion in various electrochemical and biological samples. Recent developments of LAPS-based chemical imaging sensor systems, in terms of the spatial resolution, measurement speed, image quality, miniaturization and integration with microfluidic devices, are summarized and discussed.
The artificial olfactory image was proposed by Lundström et al. in 1991 as a new strategy for an electronic nose system which generated a two-dimensional mapping to be interpreted as a fingerprint of the detected gas species. The potential distribution generated by the catalytic metals integrated into a semiconductor field-effect structure was read as a photocurrent signal generated by scanning light pulses. The impact of the proposed technology spread beyond gas sensing, inspiring the development of various imaging modalities based on the light addressing of field-effect structures to obtain spatial maps of pH distribution, ions, molecules, and impedance, and these modalities have been applied in both biological and non-biological systems. These light-addressing technologies have been further developed to realize the position control of a faradaic current on the electrode surface for localized electrochemical reactions and amperometric measurements, as well as the actuation of liquids in microfluidic devices.
Light-addressable potentiometric sensors for quantitative spatial imaging of chemical species
(2017)
A light-addressable potentiometric sensor (LAPS) is a semiconductor-based chemical sensor, in which a measurement site on the sensing surface is defined by illumination. This light addressability can be applied to visualize the spatial distribution of pH or the concentration of a specific chemical species, with potential applications in the fields of chemistry, materials science, biology, and medicine. In this review, the features of this chemical imaging sensor technology are compared with those of other technologies. Instrumentation, principles of operation, and various measurement modes of chemical imaging sensor systems are described. The review discusses and summarizes state-of-the-art technologies, especially with regard to the spatial resolution and measurement speed; for example, a high spatial resolution in a submicron range and a readout speed in the range of several tens of thousands of pixels per second have been achieved with the LAPS. The possibility of combining this technology with microfluidic devices and other potential future developments are discussed.
The deformation and damage laws of non-homogeneous irregular structural planes in rocks are the basis for studying the stability of rock engineering. To investigate the damage characteristics of rock containing non-parallel fissures, uniaxial compression tests and numerical simulations were conducted on sandstone specimens containing three non-parallel fissures inclined at 0°, 45° and 90° in this study. The characteristics of crack initiation and crack evolution of fissures with different inclinations were analyzed. A constitutive model for the discontinuous fractures of fissured sandstone was proposed. The results show that the fracture behaviors of fissured sandstone specimens are discontinuous. The stress–strain curves are non-smooth and can be divided into nonlinear crack closure stage, linear elastic stage, plastic stage and brittle failure stage, of which the plastic stage contains discontinuous stress drops. During the uniaxial compression test, the middle or ends of 0° fissures were the first to crack compared to 45° and 90° fissures. The end with small distance between 0° and 45° fissures cracked first, and the end with large distance cracked later. After the final failure, 0° fissures in all specimens were fractured, while 45° and 90° fissures were not necessarily fractured. Numerical simulation results show that the concentration of compressive stress at the tips of 0°, 45° and 90° fissures, as well as the concentration of tensile stress on both sides, decreased with the increase of the inclination angle. A constitutive model for the discontinuous fractures of fissured sandstone specimens was derived by combining the logistic model and damage mechanic theory. This model can well describe the discontinuous drops of stress and agrees well with the whole processes of the stress–strain curves of the fissured sandstone specimens.
Bacterial lipopolysaccharides (endotoxins) show strong biological effects at very low concentrations in human beings and many animals when entering the blood stream. These include affecting structure and function of organs and cells, changing metabolic functions, raising body temperature, triggering the coagulation cascade, modifying hemodynamics and causing septic shock. Because of this toxicity, the removal of even minute amounts is essential for safe parenteral administration of drugs and also for septic shock patients' care. The absence of a general method for endotoxin removal from liquid interfaces urgently requires finding new methods and materials to overcome this gap. Nanostructured carbonized plant parts is a promising material that showed good adsorption properties due to its vast pore network and high surface area. The aim of this study was comparative measurement of endotoxin- and blood proteins-related adsorption rate and adsorption capacity for different carboneous materials produced at different temperatures and under different surface modifications. As a main surface modificator, positively cbarged polymer, polyethileneimine (PEl) was used. Activated carbon materials showed good adsorption properties for LPS and some proteins used in the experiments. During the batch experiments, several techniques (dust removal, autoclaving) were used and optimized for improving the material's adsorption behavior. Also, with the results obtained it was possible to differentiate the materials according to their adsorption capacity and kinetic characteristics. Modification of the surface apparently has not affected hemoglobin binding to the adsorbent's surface. Obtained adsorption isotherms can be used as a powerful tool for designing of future column-based setups for blood purification from LPS, which is especially important for septic shock treatment.
The most of conventional methods of air purification use the power of a fan to draw in air and pass it through a filter. The problem of bacterial contamination of inner parts of such a type of air conditioners in some cases draws attention towards alternative air-cleaning systems. Some manufacturers offer to use the ozone's bactericidal and deodorizing effects, but the wide spreading of such systems is restricted by the fact that toxic effects of ozone in respect of human beings are well known. In 2000 Sharp Inc. introduced "Plasma Cluster Ions (PCI)" air purification technology, which uses plasma discharge to generate cluster ions (I 0-14 ). This technology has been developed for those customers that are conscious about health and hygiene. In our experiments, we focused on some principal aspects of plasma-generated ions application - time-dependency and irreversibility of bactericidal action, spatial and kinetic characteristics of emitted cluster particles, their chemical targets in the microbial cells.
This chapter shows that nanomaterials obtained by high-temperature carbonization of inexpensive plant raw material such as rice husk, grape seeds, and walnut shells can serve as a basis for the production of highly efficient microbial drugs, biodestructors, biosorbents, and biocatalysts, which are promising for the remediation of the ecosystem contaminated with heavy and radioactive metals, oil and oil products. A strong interest in engineering zymology is dictated by the necessity to address the issues of monitoring enzymatic processes, treatment, and diagnosis of a number of common human diseases, environmental pollution, quality control of pharmaceuticals and food. Nanomaterials obtained by high-temperature carbonization of cheap plant raw material such as-rice husks, grape seeds and walnut shells, can serve as a basis for creating of highly effective microbial preparations-biodestructors, biosorbents and biocatalysts, which are promising for the use of contaminated ecosystems, and for restoration of human intestine microecology.
The spin asymmetry in deep inelastic scattering of longitudinally polarised muons by longitudinally polarised protons has been measured over a large x range (0.01<x<0.7). The spin-dependent structure function g1(x) for the proton has been determined and its integral over x found to be 0.114±0.012±0.026, in disagreement with the Ellis-Jaffe sum rule. Assuming the validity of the Bjorken sum rule, this result implies a significant negative value for the integral of g1 for the neutron. These values for the integrals of g1 lead to the conclusion that the total quark spin constitutes a rather small fraction of the spin of the nucleon.
The spin asymmetry in deep inelastic scattering of longitudinally polarised muons by longitudinally polarised protons has been measured in the range 0.01<×<0.7. The spin dependent structure function g1(x) for the proton has been determined and, combining the data with earlier SLAC measurements, its integral over x found to be 0.126±0.010(stat.)±0.015(syst.), in disagreement with the Ellis-Jaffe sum rule. Assuming the validity of the Biorken sum rule, this result implies a significant negative value for the integral of g1 for the neutron. These integrals lead to the conclusion, in the naïve quark parton model, that the total quark spin constitutes a rather small fraction of the spin of the nucleon. Results are also presented on the asymmetries in inclusive hadron production which are consistent with the above picture.
Differential multiplicities of forward produced hadrons in deep inelastic muon scattering on nuclear targets have been compared with those from deuterium. The ratios are observed to increase towards unity as the virtual photon energy increases with no significant dependence on the other muon kinematic variables. The hadron transverse momentum distribution is observed to be broadened in nuclear targets. The dependence on the remaining hadron variables is investigated and the results are discussed in the framework of intranuclear interaction models and in the context of the EMC effect.
Measurements are presented of the inclusive distributions of the J/Ψ meson produced by muons of energy 200 GeV from an ammonia target. The gluon distribution of the nucleon has been derived from the data in the range 0.04<x<0.36 using a technique based on the colour singlet model. An arbitrary normalisation factor is required to obtain a reasonable integral of the gluon distribution. Some comments are made on the use of J/Ψ productionby virtual photons to extract the gluon distribution at HERA.
Results are presented on the ratios of the nucleon structure function in copper to deuterium from two separate experiments. The data confirm that the nucleon structure function,F 2, is different for bound nucleons than for the quasi-free ones in the deuteron. The redistribution in the fraction of the nucleon's momentum carried by quarks is investigated and it is found that the data are compatible with no integral loss of quark momenta due to nuclear effects.