Refine
Year of publication
- 2017 (154) (remove)
Document Type
- Article (72)
- Conference Proceeding (66)
- Part of a Book (12)
- Other (2)
- Book (1)
- Patent (1)
Language
- English (154) (remove)
Keywords
- MASCOT (2)
- 3D nonlinear finite element model (1)
- Acceptance tests (1)
- Automated Optimization (1)
- Autonomous mobile robots (1)
- Biomolecular logic gate (1)
- CNOT (1)
- Capacitive field-effect (1)
- Chemical images (1)
- Chemical sensor (1)
- Chimeric liver-humanized mice (1)
- Competence Developing Games (1)
- DNA (1)
- Dehydrogenase (1)
- Diaphorase (1)
- Diversity (1)
- Diversity Management (1)
- Drug distribution (1)
- Drug metabolism (1)
- Dry-low-NOx (DLN) combustion (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (61)
- IfB - Institut für Bioengineering (32)
- INB - Institut für Nano- und Biotechnologien (26)
- Fachbereich Elektrotechnik und Informationstechnik (25)
- Fachbereich Luft- und Raumfahrttechnik (22)
- Fachbereich Energietechnik (14)
- Fachbereich Chemie und Biotechnologie (12)
- Fachbereich Maschinenbau und Mechatronik (10)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (10)
- Fachbereich Bauingenieurwesen (7)
- Solar-Institut Jülich (5)
- Institut fuer Angewandte Polymerchemie (4)
- ECSM European Center for Sustainable Mobility (3)
- Fachbereich Wirtschaftswissenschaften (2)
- Fachbereich Architektur (1)
- Kommission für Forschung und Entwicklung (1)
- Nowum-Energy (1)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (1)
The capacitive electrolyte–insulator–semiconductor (EIS) structure is a typical device based on a field-effect sensor platform. With a simple silicon-based structure, EIS have been useful for several sensing applications, especially with incorporation of nanostructured films to modulate the ionic transport and the flat-band potential. In this paper, we report on ion transport and changes in flat-band potential in EIS sensors made with layer-by-layer films containing poly(amidoamine) (PAMAM) dendrimer and single-walled carbon nanotubes (SWNTs) adsorbed on p-Si/SiO 2 /Ta 2 O 5 chips with an Al ohmic contact. The impedance spectra were fitted using an equivalent circuit model, from which we could determine parameters such as the double-layer capacitance. This capacitance decreased with the number of bilayers owing to space charge accumulated at the electrolyte–insulator interface, up to three PAMAM/SWNTs bilayers, after which it stabilized. The charge-transfer resistance was also minimum for three bilayers, thus indicating that this is the ideal architecture for an optimized EIS performance. The understanding of the influence of nanostructures and the fine control of operation parameters pave the way for optimizing the design and performance of new EIS sensors.
Detection of Adrenaline Based on Bioelectrocatalytical System to Support Tumor Diagnostic Technology
(2017)
Cyber-physical systems are ever more common in manufacturing industries. Increasing their autonomy has been declared an explicit goal, for example, as part of the Industry 4.0 vision. To achieve this system intelligence, principled and software-driven methods are required to analyze sensing data, make goal-directed decisions, and eventually execute and monitor chosen tasks. In this chapter, we present a number of knowledge-based approaches to these problems and case studies with in-depth evaluation results of several different implementations for groups of autonomous mobile robots performing in-house logistics in a smart factory. We focus on knowledge-based systems because besides providing expressive languages and capable reasoning techniques, they also allow for explaining how a particular sequence of actions came about, for example, in the case of a failure.
The integration of biomolecular logic principles with electronic transducers allows designing novel digital biosensors with direct electrical output, logically triggered drug-release, and closed-loop sense/act/treat systems. This opens new opportunities for advanced personalized medicine in the context of theranostics. In the present work, we will discuss selected examples of recent developments in the field of interfacing enzyme logic gates with electrodes and semiconductor field-effect devices. Special attention is given to an enzyme OR/Reset logic gate based on a capacitive field-effect electrolyte-insulator-semiconductor sensor modified with a multi-enzyme membrane. Further examples are a digital adrenaline biosensor based on an AND logic gate with binary YES/NO output and an integrated closed-loop sense/act/treat system comprising an amperometric glucose sensor, a hydrogel actuator, and an insulin (drug) sensor.
The invention pertains to a CellDrum electrode arrangement for measuring mechanical stress, comprising a mechanical holder (1 ) and a non-conductive membrane (4), whereby the membrane (4) is at least partially fixed at its circumference to the mechanical holder (1), keeping it in place when the membrane (4) may bend due to forces acting on the membrane (4), the mechanical holder (1) and the membrane (4) forming a container, whereby the membrane (1) within the container comprises an cell- membrane compound layer or biological material (3) adhered to the deformable membrane 4 which in response to stimulation by an agent may exert mechanical stress to the membrane (4) such that the membrane bending stage changes whereby the container may be filled with an electrolyte, whereby an electric contact (2) is arranged allowing to contact said electrolyte when filled into to the container, whereby within a predefined geometry to the fixing of the membrane (4) an electrode (7) is arranged, whereby the electrode (7) is electrically insulated with respect to the electric contact (2) as well as said electrolyte, whereby mechanical stress due to an agent may be measured as a change in capacitance.