Article
Refine
Year of publication
Document Type
- Article (3149) (remove)
Language
- English (3149) (remove)
Has Fulltext
- no (3149) (remove)
Keywords
- avalanche (5)
- Earthquake (4)
- LAPS (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- CellDrum (3)
- Heparin (3)
- capacitive field-effect sensor (3)
- hydrogen peroxide (3)
- magnetic nanoparticles (3)
- snow (3)
- tobacco mosaic virus (TMV) (3)
- Bacillus atrophaeus (2)
- Chemometrics (2)
- Drinfeld modules (2)
- Empirical process (2)
- Field-effect sensor (2)
- Goodness-of-fit test (2)
- Hot S-parameter (2)
- IR spectroscopy (2)
Institute
- Fachbereich Medizintechnik und Technomathematik (1299)
- INB - Institut für Nano- und Biotechnologien (484)
- Fachbereich Chemie und Biotechnologie (454)
- Fachbereich Elektrotechnik und Informationstechnik (400)
- IfB - Institut für Bioengineering (388)
- Fachbereich Energietechnik (354)
- Fachbereich Luft- und Raumfahrttechnik (240)
- Fachbereich Maschinenbau und Mechatronik (142)
- Fachbereich Wirtschaftswissenschaften (105)
- Fachbereich Bauingenieurwesen (64)
- Solar-Institut Jülich (41)
- ECSM European Center for Sustainable Mobility (23)
- Sonstiges (21)
- Institut fuer Angewandte Polymerchemie (20)
- Freshman Institute (17)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (14)
- Fachbereich Gestaltung (12)
- Nowum-Energy (12)
- Fachbereich Architektur (9)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (5)
HisT/PLIER : A Two-Fold Provenance Approach for Grid-Enabled Scientific Workflows Using WS-VLAM
(2011)
This paper describes the modeling of a high-temperature storage system for an existing solar tower power plant with open volumetric receiver technology, which uses air as heat transfer medium (HTF). The storage system model has been developed in the simulation environment Matlab/Simulink®. The storage type under investigation is a packed bed thermal energy storage system which has the characteristics of a regenerator. Thermal energy can be stored and discharged as required via the HTF air. The air mass flow distribution is controlled by valves, and the mass flow by two blowers. The thermal storage operation strategy has a direct and significant impact on the energetic and economic efficiency of the solar tower power plants.
High-spin states in ¹⁸⁰ Os
(1979)
High-spin states in ¹³³ La
(1982)
High-spin states in ¹³³ La
(1980)
High-spin isomer in ¹³⁷ Ce
(1978)
The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the spatial distribution of specific ions on the sensing surface. The conventional chemical imaging system based on the light-addressable potentiometric sensor (LAPS), however, required a long time to obtain a chemical image, due to the slow mechanical scan of a single light beam. For high-speed imaging, a plurality of light beams modulated at different frequencies can be employed to measure the ion concentrations simultaneously at different locations on the sensor plate by frequency division multiplex (FDM). However, the conventional measurement geometry of back-side illumination limited the bandwidth of the modulation frequency required for FDM measurement, because of the low-pass filtering characteristics of carrier diffusion in the Si substrate. In this study, a high-speed chemical imaging system based on front-side-illuminated LAPS was developed, which achieved high-speed spatiotemporal recording of pH change at a rate of 70 frames per second.
In this study, a high-speed chemical imaging system was developed for visualization of the interior of a microfluidic channel. A microfluidic channel was constructed on the sensor surface of the light-addressable potentiometric sensor (LAPS), on which the ion concentrations could be measured in parallel at up to 64 points illuminated by optical fibers. The temporal change of pH distribution inside the microfluidic channel was recorded at a maximum rate of 100 frames per second (fps). The high frame rate allowed visualization of moving interfaces and plugs in the channel even at a flow velocity of 111 mm/s, which suggests the feasibility of plug-based microfluidic devices for flow-injection analysis (FIA).
Yrast states up to spin 18 have been identified in ¹³²Ce. The energies and spins of the levels suggest the existence of two fairly well-behaved collective bands. The results are compared with those obtained in the rare-earth deformed region.
High spin states in ¹⁹¹ Au
(1975)
High spin states in ¹⁹¹ Au
(1975)
High spin states in ¹⁸⁸ Au
(1982)
High spin states in ¹³⁶ Ce
(1975)
High spin states in ¹³⁶ Ce
(1975)
Light-addressable potentiometric sensors (LAPS) are field-effect-based sensors. A modulated light source is used to define the particular measurement spot to perform spatially resolved measurements of chemical species and to generate chemical images. In this work, an organic-LED (OLED) display has been chosen as a light source. This allows high measurement resolution and miniaturisation of the system. A new developed driving method for the OLED display optimised for LAPS-based measurements is demonstrated. The new method enables to define modulation frequencies between 1 kHz and 16 kHz and hence, reduces the measurement time of a chemical image by a factor of 40 compared to the traditional addressing of an OLED display.
High resolution temperature measurement technique for materials sciences experiments in space
(1998)
The ClearPET™ Neuro is the first full ring scanner within the Crystal Clear Collaboration (CCC). It consists of 80 detector modules allocated to 20 cassettes. LSO and LuYAP:Ce crystals in phoswich configuration in combination with position sensitive photomultiplier tubes are used to achieve high sensitivity and realize the acquisition of the depth of interaction (DOI) information. The complete system has been tested concerning the mechanical and electronical stability and interplay. Moreover, suitable corrections have been implemented into the reconstruction procedure to ensure high image quality. We present first results which show the successful operation of the ClearPET™ Neuro for artefact free and high resolution small animal imaging. Based on these results during the past few months the ClearPET™ Neuro System has been modified in order to optimize the performance.
Clostridium propionicum is the only organism known to ferment β-alanine, a constituent of coenzyme A (CoA) and the phosphopantetheinyl prosthetic group of holo-acyl carrier protein. The first step in the fermentation is a CoA-transfer to β-alanine. Subsequently, the resulting β-alanyl-CoA is deaminated by the enzyme β-alanyl-CoA:ammonia lyase (Acl) to reversibly form ammonia and acrylyl-CoA. We have determined the crystal structure of Acl in its apo-form at a resolution of 0.97 Å as well as in complex with CoA at a resolution of 1.59 Å. The structures reveal that the enyzme belongs to a superfamily of proteins exhibiting a so called “hot dog fold” which is characterized by a five-stranded antiparallel β-sheet with a long α-helix packed against it. The functional unit of all “hot dog fold” proteins is a homodimer containing two equivalent substrate binding sites which are established by the dimer interface. In the case of Acl, three functional dimers combine to a homohexamer strongly resembling the homohexamer formed by YciA-like acyl-CoA thioesterases. Here, we propose an enzymatic mechanism based on the crystal structure of the Acl·CoA complex and molecular docking. Proteins 2014; 82:2041–2053. © 2014 Wiley Periodicals, Inc.