Refine
Year of publication
Document Type
- Article (5464) (remove)
Language
Has Fulltext
- no (5464) (remove)
Keywords
- avalanche (5)
- Earthquake (4)
- LAPS (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- CellDrum (3)
- Heparin (3)
- capacitive field-effect sensor (3)
- hydrogen peroxide (3)
- magnetic nanoparticles (3)
- snow (3)
- tobacco mosaic virus (TMV) (3)
- Bacillus atrophaeus (2)
- Chemometrics (2)
- Datenschutz (2)
- Datenschutzgrundverordnung (2)
- Drinfeld modules (2)
- Empirical process (2)
- Field-effect sensor (2)
- Goodness-of-fit test (2)
Institute
- Fachbereich Medizintechnik und Technomathematik (1531)
- Fachbereich Wirtschaftswissenschaften (683)
- Fachbereich Elektrotechnik und Informationstechnik (617)
- Fachbereich Energietechnik (597)
- Fachbereich Chemie und Biotechnologie (585)
- INB - Institut für Nano- und Biotechnologien (523)
- Fachbereich Maschinenbau und Mechatronik (463)
- IfB - Institut für Bioengineering (426)
- Fachbereich Luft- und Raumfahrttechnik (364)
- Fachbereich Bauingenieurwesen (324)
- Solar-Institut Jülich (105)
- Fachbereich Architektur (76)
- Fachbereich Gestaltung (55)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (39)
- ECSM European Center for Sustainable Mobility (33)
- Nowum-Energy (28)
- Sonstiges (23)
- Institut fuer Angewandte Polymerchemie (20)
- Freshman Institute (18)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (15)
Museen und neue Medien
(1997)
Metamorphose und Morphing
(1995)
Focus Artaud : Textcollage
(1997)
Learning from Brachelen
(2002)
Chicks off speed
(2009)
Im Reich der Sinne
(2011)
Pepräsentatives Dösen
(2013)
Sisyphus wird Steiff
(2010)
The Kremer–Grest (KG) polymer model is a standard model for studying generic polymer properties in molecular dynamics simulations. It owes its popularity to its simplicity and computational efficiency, rather than its ability to represent specific polymers species and conditions. Here we show that by tuning the chain stiffness it is possible to adapt the KG model to model melts of real polymers. In particular, we provide mapping relations from KG to SI units for a wide range of commodity polymers. The connection between the experimental and the KG melts is made at the Kuhn scale, i.e., at the crossover from the chemistry-specific small scale to the universal large scale behavior. We expect Kuhn scale-mapped KG models to faithfully represent universal properties dominated by the large scale conformational statistics and dynamics of flexible polymers. In particular, we observe very good agreement between entanglement moduli of our KG models and the experimental moduli of the target polymers.
Möglichkeiten der ottomotorischen Prozeßführung bei Verwendung des elektromechanischen Ventiltriebs
(1998)
Low emission zones and truck bans, the rising price of diesel and increases in road tolls: all of these factors are putting serious pressure on the transport industry. Commercial vehicle manufacturers and their suppliers are in the process of identifying new solutions to these challenges as part of their efforts to meet the EEV (enhanced environmentally friendly vehicle) limits, which are currently the most robust European exhaust and emissions standards for trucks and buses.
Purpose — to compare the chemical elemental composition of vitreous cavity content taken from cadaveric eyes compared to samples taken from the eyes with terminal stage refractory glaucoma with decompensated intraocular pressure (IOP). Material and methods. The vitreous contents of the eyes from 2 groups were studied. The 1st group included 15 cadaveric eyes; the 2nd group included 15 eyes with refractory glaucoma in the terminal stage of the disease with decompensated IOP in patients with hypertension pain. The vitreal content samples were taken in the course of antiglaucoma surgery aimed at preserving the eye as an organ and involving employment of drainage in the vitreous cavity. The study of virtual contents was carried out on energy dispersive spectrometer Oxford X-Max 50 integrated into scanning electron microscope Zeiss EVO LS10. Results. Increased concentrations of Kalium and Phosphorus were detected in the vitreous content of cadaveric eyes compared with the vitreal content from the eyes with terminal glaucoma with decompensated IOP taken in vivo (K — 0.172/0.093; P — 0.045/0.025 mmol/L). In the vitreous cavity in the eyes with end-stage glaucoma with decompensated IOP, the concentration of Nitrogen was higher in comparison with human cadaver eyes (2.030/1.424 mmol/L). Conclusion. The increased concentrations of Kalium and Phosphorus in the vitreous content of cadaveric eyes is associated with postmortem autolytic processes and with the release of intracellular content in the destruction of cell membranes. The increased Nitrogen concentration in the vitreal contents of the eyes with terminal stage glaucoma with decompensated IOP may be associated with the presence of osmotically active nitrogen-containing compounds in the eyes with increased IOP.
The hybrid K+/Ca2+ sensor based on laser scanned silicon transducer for multi-component analysis
(2002)
Modellfabrik im Zeichen der Automatisierungstechnik / Gall, Jan ; Enning, Manfred ; Abel, Dirk
(2008)
Universelle hydraulische Try-Out Presse / Teilprojekt A6 / Wiendahl, H.-P. ; Doege, E. ; Engels, E.
(1999)
Pressen - Vergleich zwischen Raumlenker- und Exzenterantrieb / Doege, Eckhart ; Engels, Elmar
(1999)
Pressen - Hubzahlregelung an Schnelläuferpressen mit Fuzzy-Reglern / Doege, Eckhart ; Engels, Elmar
(1998)
Frequency mixing magnetic detection (FMMD) is a sensitive and selective technique to detect magnetic nanoparticles (MNPs) serving as probes for binding biological targets. Its principle relies on the nonlinear magnetic relaxation dynamics of a particle ensemble interacting with a dual frequency external magnetic field. In order to increase its sensitivity, lower its limit of detection and overall improve its applicability in biosensing, matching combinations of external field parameters and internal particle properties are being sought to advance FMMD. In this study, we systematically probe the aforementioned interaction with coupled Néel–Brownian dynamic relaxation simulations to examine how key MNP properties as well as applied field parameters affect the frequency mixing signal generation. It is found that the core size of MNPs dominates their nonlinear magnetic response, with the strongest contributions from the largest particles. The drive field amplitude dominates the shape of the field-dependent response, whereas effective anisotropy and hydrodynamic size of the particles only weakly influence the signal generation in FMMD. For tailoring the MNP properties and parameters of the setup towards optimal FMMD signal generation, our findings suggest choosing large particles of core sizes dc > 25 nm nm with narrow size distributions (σ < 0.1) to minimize the required drive field amplitude. This allows potential improvements of FMMD as a stand-alone application, as well as advances in magnetic particle imaging, hyperthermia and magnetic immunoassays.
Dual frequency magnetic excitation of magnetic nanoparticles (MNP) enables enhanced biosensing applications. This was studied from an experimental and theoretical perspective: nonlinear sum-frequency components of MNP exposed to dual-frequency magnetic excitation were measured as a function of static magnetic offset field. The Langevin model in thermodynamic equilibrium was fitted to the experimental data to derive parameters of the lognormal core size distribution. These parameters were subsequently used as inputs for micromagnetic Monte-Carlo (MC)-simulations. From the hysteresis loops obtained from MC-simulations, sum-frequency components were numerically demodulated and compared with both experiment and Langevin model predictions. From the latter, we derived that approximately 90% of the frequency mixing magnetic response signal is generated by the largest 10% of MNP. We therefore suggest that small particles do not contribute to the frequency mixing signal, which is supported by MC-simulation results. Both theoretical approaches describe the experimental signal shapes well, but with notable differences between experiment and micromagnetic simulations. These deviations could result from Brownian relaxations which are, albeit experimentally inhibited, included in MC-simulation, or (yet unconsidered) cluster-effects of MNP, or inaccurately derived input for MC-simulations, because the largest particles dominate the experimental signal but concurrently do not fulfill the precondition of thermodynamic equilibrium required by Langevin theory.