Article
Refine
Year of publication
- 2024 (16)
- 2023 (59)
- 2022 (75)
- 2021 (80)
- 2020 (93)
- 2019 (95)
- 2018 (83)
- 2017 (72)
- 2016 (78)
- 2015 (83)
- 2014 (93)
- 2013 (96)
- 2012 (80)
- 2011 (128)
- 2010 (119)
- 2009 (119)
- 2008 (102)
- 2007 (94)
- 2006 (86)
- 2005 (99)
- 2004 (131)
- 2003 (74)
- 2002 (92)
- 2001 (88)
- 2000 (84)
- 1999 (88)
- 1998 (82)
- 1997 (79)
- 1996 (70)
- 1995 (68)
- 1994 (76)
- 1993 (51)
- 1992 (48)
- 1991 (25)
- 1990 (35)
- 1989 (38)
- 1988 (54)
- 1987 (32)
- 1986 (18)
- 1985 (32)
- 1984 (18)
- 1983 (17)
- 1982 (26)
- 1981 (18)
- 1980 (35)
- 1979 (23)
- 1978 (30)
- 1977 (14)
- 1976 (13)
- 1975 (10)
- 1974 (3)
- 1972 (2)
- 1971 (1)
- 1968 (1)
Document Type
- Article (3226) (remove)
Language
- English (3226) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- biosensors (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- CellDrum (3)
- Heparin (3)
- Label-free detection (3)
- additive manufacturing (3)
- capacitive field-effect sensor (3)
- hydrogen peroxide (3)
- magnetic nanoparticles (3)
- shakedown analysis (3)
- snow (3)
- tobacco mosaic virus (TMV) (3)
- Acyl-amino acids (2)
Institute
- Fachbereich Medizintechnik und Technomathematik (1343)
- INB - Institut für Nano- und Biotechnologien (501)
- Fachbereich Chemie und Biotechnologie (466)
- IfB - Institut für Bioengineering (408)
- Fachbereich Elektrotechnik und Informationstechnik (401)
- Fachbereich Energietechnik (360)
- Fachbereich Luft- und Raumfahrttechnik (247)
- Fachbereich Maschinenbau und Mechatronik (147)
- Fachbereich Wirtschaftswissenschaften (106)
- Fachbereich Bauingenieurwesen (68)
- Solar-Institut Jülich (43)
- ECSM European Center for Sustainable Mobility (27)
- Sonstiges (21)
- Institut fuer Angewandte Polymerchemie (20)
- Freshman Institute (17)
- Nowum-Energy (16)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (15)
- Fachbereich Gestaltung (12)
- Fachbereich Architektur (9)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (5)
Design of a Measurement Setup for the Impedance of Low-Resistance Plate-Conductors in the RF-Range
(2006)
The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in Jülich (ClearPET Neuro) is equipped with 10240 crystals on 80 PMTs. The paper will present an overview of the data acquisition system.
The ClearPET™ Neuro is the first full ring scanner within the Crystal Clear Collaboration (CCC). It consists of 80 detector modules allocated to 20 cassettes. LSO and LuYAP:Ce crystals in phoswich configuration in combination with position sensitive photomultiplier tubes are used to achieve high sensitivity and realize the acquisition of the depth of interaction (DOI) information. The complete system has been tested concerning the mechanical and electronical stability and interplay. Moreover, suitable corrections have been implemented into the reconstruction procedure to ensure high image quality. We present first results which show the successful operation of the ClearPET™ Neuro for artefact free and high resolution small animal imaging. Based on these results during the past few months the ClearPET™ Neuro System has been modified in order to optimize the performance.
The small animal PET scanners developed by the Crystal Clear Collaboration (ClearPETtrade) detect coincidences by analyzing timemarks which are attached to each event. The scanners are able to save complete single list mode data which allows analysis and modification of the timemarks after data acquisition. The timemarks are obtained from the digitally sampled detector pulses by calculating the baseline crossing of the rising edge of the pulse which is approximated as a straight line. But the limited sampling frequency causes a systematic error in the determination of the timemark. This error depends on the phase of the sampling clock at the time of the event. A statistical method that corrects these errors will be presented
Development of an optimized LSO/LuYAP phoswich detector head for the Lausanne ClearPET demonstrator
(2006)
This paper describes the LSO/LuYAP phoswich detector head developed for the ClearPET small animal PET scanner demonstrator that is under construction in Lausanne within the Crystal Clear Collaboration. The detector head consists of a dual layer of 8×8 LSO and LuYAP crystal arrays coupled to a multi-anode photomultiplier tube (Hamamatsu R7600-M64). Equalistion of the LSO/LuYAP light collection is obtained through partial attenuation of the LSO scintillation light using a thin aluminum deposit of 20-35 nm on LSO and appropriate temperature regulation of the phoswich head between 30°C to 60°C. At 511keV, typical FWHM energy resolutions of the pixels of a phoswich head amounts to (28±2)% for LSO and (25±2)% for LuYAP. The LSO versus LuYAP crystal identification efficiency is better than 98%. Six detector modules have been mounted on a rotating gantry. Axial and tangential spatial resolutions were measured up to 4 cm from the scanner axis and compared to Monte Carlo simulations using GATE. FWHM spatial resolution ranges from 1.3 mm on axis to 2.6 mm at 4 cm from the axis.
Table of Contents Introduction 1. Generative Manufacturing Processes 2. Classification of Generative Manufacturing Processes 3. Application of Generative Processes on the Fabrication of Ceramic Parts 3.1 Extrusion 3.2 3D-Printing 3.3 Sintering – Laser Sintering 3.4 Layer-Laminate Processes 3.5 Stereolithography (sometimes written: Stereo Lithography) 4. Layer Milling 5. Conclusion - Vision
In: Advanced Engineering Informatics. Vol 21, Issue 1, 2007, Pages 67-83 http://dx.doi.org/10.1016/j.aei.2006.10.001 eds. J.C. Kunz, I.F.C. Smith and T. Tomiyama, Elsevier, Seite 1-22 Current CAD tools are not able to support the conceptual design phase, and none of them provides a consistency analysis for sketches produced by architects. This phase is fundamental and crucial for the whole design and construction process of a building. To give architects a better support, we developed a CAD tool for conceptual design and a knowledge specification tool. The knowledge is specific to one class of buildings and it can be reused. Based on a dynamic and domain-specific knowledge ontology, different types of design rules formalize this knowledge in a graph-based form. An expressive visual language provides a user-friendly, human readable representation. Finally, a consistency analysis tool enables conceptual designs to be checked against this formal conceptual knowledge. In this article, we concentrate on the knowledge specification part. For that, we introduce the concepts and usage of a novel visual language and describe its semantics. To demonstrate the usability of our approach, two graph-based visual tools for knowledge specification and conceptual design are explained.
The most of conventional methods of air purification use the power of a fan to draw in air and pass it through a filter. The problem of bacterial contamination of inner parts of such a type of air conditioners in some cases draws attention towards alternative air-cleaning systems. Some manufacturers offer to use the ozone's bactericidal and deodorizing effects, but the wide spreading of such systems is restricted by the fact that toxic effects of ozone in respect of human beings are well known. In 2000 Sharp Inc. introduced "Plasma Cluster Ions (PCI)" air purification technology, which uses plasma discharge to generate cluster ions (I 0-14 ). This technology has been developed for those customers that are conscious about health and hygiene. In our experiments, we focused on some principal aspects of plasma-generated ions application - time-dependency and irreversibility of bactericidal action, spatial and kinetic characteristics of emitted cluster particles, their chemical targets in the microbial cells.
Handheld measurement device for field-effect sensor structures: Practical evaluation and limitations
(2007)