Conference Proceeding
Refine
Year of publication
Document Type
- Conference Proceeding (208) (remove)
Language
- English (208) (remove)
Keywords
- Biosensor (25)
- CAD (7)
- Finite-Elemente-Methode (7)
- civil engineering (7)
- Bauingenieurwesen (6)
- Clusterion (4)
- Limit analysis (4)
- Natural language processing (4)
- Air purification (3)
- Einspielen <Werkstoff> (3)
- Hämoglobin (3)
- Luftreiniger (3)
- Plasmacluster ion technology (3)
- Raumluft (3)
- Shakedown analysis (3)
- Sonde (3)
- shakedown analysis (3)
- Bruchmechanik (2)
- Clustering (2)
- Eisschicht (2)
- Erythrozyt (2)
- FEM (2)
- Information extraction (2)
- Kohlenstofffaser (2)
- Lipopolysaccharide (2)
- Shakedown (2)
- Stickstoffmonoxid (2)
- biosensor (2)
- celldrum technology (2)
- limit analysis (2)
- lipopolysaccharides (2)
- nitric oxide gas (2)
- 3-nitrofluoranthene (1)
- Active learning (1)
- Adsorption (1)
- Agent-based simulation (1)
- Analytischer Zulaessigkeitsnachweis (1)
- Anastomose (1)
- Anastomosis (1)
- Autofluoreszenzverfahren (1)
- BTEX compounds (1)
- Bakterien (1)
- Bio-Sensors (1)
- Biomechanics (1)
- Biomechanik (1)
- Biomedizinische Technik (1)
- Biophoton (1)
- Biosensorik (1)
- Blitzschutz (1)
- CAD ; (1)
- CO (1)
- Chance constrained programming (1)
- Cloud Computing (1)
- Cloud Service Broker (1)
- Conducing polymer (1)
- Dattel (1)
- Deep learning (1)
- Dekontamination (1)
- ECT (1)
- EEG (1)
- EPN (1)
- Einspiel-Analyse (1)
- Einspielanalyse (1)
- Elastodynamik (1)
- Elektrodynamik (1)
- Endothelzelle (1)
- Energy market design (1)
- Evolution of damage (1)
- Exact Ilyushin yield surface (1)
- Extension fracture (1)
- Extension strain criterion (1)
- Festkörper (1)
- Fibroblast (1)
- Finite element method (1)
- First Order Reliabiblity Method (1)
- First-order reliability method (1)
- Fluorescence (1)
- Force (1)
- GaAs hot electron injector (1)
- Gas sensor (1)
- Grid Computing (1)
- Gunn diode (1)
- Heavy metal detection (1)
- High throughput experimentation (1)
- Hotplate (1)
- Hydrodynamik (1)
- Hydrogel (1)
- Hydrogen sensor (1)
- I3S 2005 (1)
- ISFET (1)
- Impedance Spectroscopy (1)
- Information Extraction (1)
- International Symposium on Sensor Science (1)
- Iterative learning control (1)
- Knee (1)
- Körpertemperatur (1)
- LED chip (1)
- Level sensor (1)
- Lichtstreuungsbasierte Instrumente (1)
- Load modeling (1)
- MEMS (1)
- Machine learning (1)
- Main sensitivity (1)
- Market modeling (1)
- Mechanische Beanspruchung (1)
- Microreactors (1)
- Mohr–Coulomb criterion (1)
- Multi-dimensional wave propagation (1)
- Nano Materials (1)
- Nanomaterial (1)
- Nanoparticles (1)
- Nanopartikel (1)
- Nanostructuring (1)
- Nanotechnologie (1)
- Nanotechnology ; Microelectronics ; Biosensors ; Superconductor ; MEMS (1)
- Natriumhypochlorit (1)
- Natural Language Processing (1)
- Natural language understanding (1)
- Nichtlineare Gleichung (1)
- Nichtlineare Optimierung (1)
- Nichtlineare Welle (1)
- Organophosphorus (1)
- Ostazine Orange (1)
- PFM (1)
- Pflanzenphysiologie (1)
- Pflanzenscanner (1)
- Phenylalanine determination (1)
- Potentiometry (1)
- Process model (1)
- Profile Extraction (1)
- Profile extraction (1)
- Proteine (1)
- Pseudomonas putida (1)
- Quartz crystal nanobalance (QCN) (1)
- Quartz micro balances (1)
- Query learning (1)
- Random variable (1)
- Ratcheting (1)
- Reaction-diffusion (1)
- Relation classification (1)
- Reliability of structures (1)
- Reproducible research (1)
- Sensitivity (1)
- Sepsis (1)
- Sleep EEG (1)
- Solid amalgam electrodes (1)
- Stochastic programming (1)
- Supraleiter (1)
- Technische Mechanik (1)
- Text Mining (1)
- Text mining (1)
- Tin oxide (1)
- Tobacco mosaic virus (1)
- Traglast (1)
- Traglastanalyse (1)
- Training (1)
- Trustworthy artificial intelligence (1)
- UML (1)
- Unified Modeling Language (1)
- Wafer (1)
- Wasserbrücke (1)
- Wasserstoffperoxid (1)
- Wellen (1)
- Workflow (1)
- Workflow Orchestration (1)
- acetoin (1)
- activated nanostructured carbon (1)
- aktivierte nanostrukturierte Kohlenstofffaser (1)
- ammonia gas sensors (1)
- amperometric sensor (1)
- antimony doped tin oxide (1)
- autofluorescence-based detection system (1)
- biopotential electrodes (1)
- capacitive field-effect biosensor (1)
- capillary micro-droplet cell (1)
- carcinogens (1)
- catalytic decomposition (1)
- chemical reduction method (1)
- contractile tension (1)
- cross sensitivity (1)
- cytosolic water diffusion (1)
- date palm tree (1)
- design-by-analysis (1)
- doped metal oxide (1)
- doped silicon (1)
- doping (1)
- electrical capacitance tomography (1)
- electro-migration (1)
- electronic noses dendronized polymers inverted mesa technology (1)
- enzymatic methods (1)
- enzyme immobilisation (1)
- enzyme immobilization (1)
- fenitrothion (1)
- finite element analysis (1)
- fluidic (1)
- gas sensor (1)
- gas sensor array (1)
- heater metallisation (1)
- hemoglobin (1)
- hemoglobin dynamics (1)
- high-temperature stability (1)
- humidity (1)
- hydrogel (1)
- hydrogen peroxide (1)
- image sensor (1)
- imaging (1)
- impedance spectroscopy (1)
- ion-selective electrodes (1)
- kontraktile Spannung (1)
- lab-on-a-chip (1)
- lab-on-chip (1)
- layer expansion (1)
- lenslet array (1)
- light scattering analysis (1)
- lightning flash (1)
- limit and shakedown analysis (1)
- limit load (1)
- linear kinematic hardening (1)
- lower bound theorem (1)
- magnetic particles (1)
- material shakedown (1)
- matrix method (1)
- mechanical waves (1)
- metal oxide (1)
- microreactor (1)
- microwave generation (1)
- modeling biosensor (1)
- modelling (1)
- modified electrode (1)
- multi-interface measurement (1)
- nanostructured carbonized plant parts (1)
- nanostrukturierte carbonisierte Pflanzenteile (1)
- nitrogen oxides (1)
- nonlinear kinematic hardening (1)
- nonlinear optimization (1)
- nonlinear solids (1)
- nonlinear tensor constitutive equation (1)
- organic PVC membranes (1)
- pH-based biosensing (1)
- pattern-size reduction (1)
- plant scanner (1)
- plasma generated ions (1)
- polymer composites (1)
- porous Pt electrode (1)
- principal component (1)
- probabilistic fracture mechanics (1)
- protein (1)
- quantum charging (1)
- ratchetting (1)
- reliability (1)
- rhAPC (1)
- screen-printing (1)
- second-order reliability method (1)
- self-aligned patterning (1)
- sensing properties (1)
- sensors (1)
- shakedown (1)
- sterilisation (1)
- subsurface ice research (1)
- subsurface probe (1)
- surface modification (1)
- swift heavy ions (1)
- thick-film technology (1)
- thin-film microsensors (1)
- voltammetry (1)
- wafer-level testing (1)
- water bridge phenomenon (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (208) (remove)
The workflow of a high throughput screening setup for the rapid identification of new and improved sensor materials is presented. The polyol method was applied to prepare nanoparticular metal oxides as base materials, which were functionalised by surface doping. Using multi-electrode substrates and high throughput impedance spectroscopy (HT-IS) a wide range of materials could be screened in a short time. Applying HT-IS in search of new selective gas sensing materials a NO2-tolerant NO sensing material with reduced sensitivities towards other test gases was identified based on iridium doped zinc oxide. Analogous behaviour was observed for iridium doped indium oxide.
Applications of Graph Transformations with Industrial Relevance Lecture Notes in Computer Science, 2004, Volume 3062/2004, 434-439, DOI: http://dx.doi.org/10.1007/978-3-540-25959-6_33 This paper gives a brief overview of the tools we have developed to support conceptual design in civil engineering. Based on the UPGRADE framework, two applications, one for the knowledge engineer and another for architects allow to store domain specific knowledge and to use this knowledge during conceptual design. Consistency analyses check the design against the defined knowledge and inform the architect if rules are violated.
In: Advances in intelligent computing in engineering : proceedings of the 9.International EG-ICE Workshop ; Darmstadt, (01 - 03 August) 2002 / Martina Schnellenbach-Held ... (eds.) . - Düsseldorf: VDI-Verl., 2002 .- Fortschritt-Berichte VDI, Reihe 4, Bauingenieurwesen ; 180 ; S. 1-35 The paper describes a novel way to support conceptual design in civil engineering. The designer uses semantical tools guaranteeing certain internal structures of the design result but also the fulfillment of various constraints. Two different approaches and corresponding tools are discussed: (a) Visually specified tools with automatic code generation to determine a design structure as well as fixing various constraints a design has to obey. These tools are also valuable for design knowledge specialist. (b) Extensions of existing CAD tools to provide semantical knowledge to be used by an architect. It is sketched how these different tools can be combined in the future. The main part of the paper discusses the concepts and realization of two prototypes following the two above approaches. The paper especially discusses that specific graphs and the specification of their structure are useful for both tool realization projects.
ITCE-2003 - 4th Joint Symposium on Information Technology in Civil Engineering ed Flood, I., Seite 1-12, ASCE (CD-ROM), Nashville, USA In this paper we discussed graph based tools to support architects during the conceptual design phase. Conceptual Design is defined before constructive design; the used concepts are more abstract. We develop two graph based approaches, a topdown using the graph rewriting system PROGRES and a more industrially oriented approach, where we extend the CAD system ArchiCAD. In both approaches, knowledge can be defined by a knowledge engineer, in the top-down approach in the domain model graph, in the bottom-up approach in the in an XML file. The defined knowledge is used to incrementally check the sketch and to inform the architect about violations of the defined knowledge. Our goal is to discover design error as soon as possible and to support the architect to design buildings with consideration of conceptual knowledge.
In: Proc. of the 11th Intl. Conf. on Computing in Civil and Building Engineering (ICCCBE-XI) ed. Hugues Rivard, Montreal, Canada, Seite 1-12, ACSE (CD-ROM), 2006 Currently, the conceptual design phase is not adequately supported by any CAD tool. Neither the support while elaborating conceptual sketches, nor the automatic proof of correctness with respect to effective restrictions is currently provided by any commercial tool. To enable domain experts to store the common as well as their personal domain knowledge, we develop a visual language for knowledge formalization. In this paper, a major extension to the already existing concepts is introduced. The possibility to define rule dependencies extends the expressiveness of the knowledge definition language and contributes to the usability of our approach.
In: Computer Aided Architectural Design Futures 2005 2005, Part 4, 207-216, DOI: http://dx.doi.org/10.1007/1-4020-3698-1_19 The conceptual design at the beginning of the building construction process is essential for the success of a building project. Even if some CAD tools allow elaborating conceptual sketches, they rather focus on the shape of the building elements and not on their functionality. We introduce semantic roomobjects and roomlinks, by way of example to the CAD tool ArchiCAD. These extensions provide a basis for specifying the organisation and functionality of a building and free architects being forced to directly produce detailed constructive sketches. Furthermore, we introduce consistency analyses of the conceptual sketch, based on an ontology containing conceptual relevant knowledge, specific to one class of buildings.
In: Net-distributed Co-operation : Xth International Conference on Computing in Civil and Building Engineering, Weimar, June 02 - 04, 2004 ; proceedings / [ed. by Karl Beuke ...] . - Weimar: Bauhaus-Univ. Weimar 2004. - 1. Aufl. . Seite 1-14 ISBN 3-86068-213-X International Conference on Computing in Civil and Building Engineering <10, 2004, Weimar> Summary In our project, we develop new tools for the conceptual design phase. During conceptual design, the coarse functionality and organization of a building is more important than a detailed worked out construction. We identify two roles, first the knowledge engineer who is responsible for knowledge definition and maintenance; second the architect who elaborates the conceptual de-sign. The tool for the knowledge engineer is based on graph technology, it is specified using PROGRES and the UPGRADE framework. The tools for the architect are integrated to the in-dustrial CAD tool ArchiCAD. Consistency between knowledge and conceptual design is en-sured by the constraint checker, another extension to ArchiCAD.
Proc. of the 2005 ASCE Intl. Conf. on Computing in Civil Engineering (ICCC 2005) eds. L. Soibelman und F. Pena-Mora, Seite 1-14, ASCE (CD-ROM), Cancun, Mexico, 2005 Current CAD tools are not able to support the fundamental conceptual design phase, and none of them provides consistency analyses of sketches produced by architects. To give architects a greater support at the conceptual design phase, we develop a CAD tool for conceptual design and a knowledge specification tool allowing the definition of conceptually relevant knowledge. The knowledge is specific to one class of buildings and can be reused. Based on a dynamic knowledge model, different types of design rules formalize the knowledge in a graph-based realization. An expressive visual language provides a user-friendly, human readable representation. Finally, consistency analyses enable conceptual designs to be checked against this defined knowledge. In this paper we concentrate on the knowledge specification part of our project.
An array of 50 MHz quartz microbalances (QMBs) coated with a dendronized polymer was used to detect small amounts of volatile organic compounds (VOCs) in the gas phase. The results were compared to those obtained with the commonly used 10 MHz QMBs. The 50 MHz QMBs proved to be a powerful tool for the detection of VOCs in the gas phase; therefore, they represent a promising alternative to the much more delicate surface acoustic wave devices (SAWs).
In energy economy forecasts of different time series are rudimentary. In this study, a prediction for the German day-ahead spot market is created with Apache Spark and R. It is just an example for many different applications in virtual power plant environments. Other examples of use as intraday price processes, load processes of machines or electric vehicles, real time energy loads of photovoltaic systems and many more time series need to be analysed and predicted.
This work gives a short introduction into the project where this study is settled. It describes the time series methods that are used in energy industry for forecasts shortly. As programming technique Apache Spark, which is a strong cluster computing technology, is utilised. Today, single time series can be predicted. The focus of this work is on developing a method to parallel forecasting, to process multiple time series simultaneously with R and Apache Spark.
This paper reports a first microbial biosensor for rapid and cost-effective determination of organophosphorus pesticides fenitrothion and EPN. The biosensor consisted of recombinant PNP-degrading/oxidizing bacteria Pseudomonas putida JS444 anchoring and displaying organophosphorus hydrolase (OPH) on its cell surface as biological sensing element and a dissolved oxygen electrode as the transducer. Surfaceexpressed OPH catalyzed the hydrolysis of fenitrothion and EPN to release 3-methyl-4-nitrophenol and p-nitrophenol, respectively, which were oxidized by the enzymatic machinery of Pseudomonas putida JS444 to carbon dioxide while consuming oxygen, which was measured and correlated to the concentration of organophosphates. Under the optimum operating conditions, the biosensor was able to measure as low as 277 ppb of fenitrothion and 1.6 ppm of EPN without interference from phenolic compounds and other commonly used pesticides such as carbamate pesticides, triazine herbicides and organophosphate pesticides without nitrophenyl substituent. The applicability of the biosensor to lake water was also demonstrated.
Conventional EEG devices cannot be used in everyday life and
hence, past decade research has been focused on Ear-EEG for mobile,
at-home monitoring for various applications ranging from
emotion detection to sleep monitoring. As the area available for
electrode contact in the ear is limited, the electrode size and location
play a vital role for an Ear-EEG system. In this investigation, we
present a quantitative study of ear-electrodes with two electrode
sizes at different locations in a wet and dry configuration. Electrode
impedance scales inversely with size and ranges from 450 kΩ to
1.29 MΩ for dry and from 22 kΩ to 42 kΩ for wet contact at 10 Hz.
For any size, the location in the ear canal with the lowest impedance
is ELE (Left Ear Superior), presumably due to increased contact
pressure caused by the outer-ear anatomy. The results can be used
to optimize signal pickup and SNR for specific applications. We
demonstrate this by recording sleep spindles during sleep onset
with high quality (5.27 μVrms).
The sorption of LPS toxic shock by nanoparticles on base of carbonized vegetable raw materials
(2008)
Immobilization of lactobacillus on high temperature carbonizated vegetable raw material (rice husk, grape stones) increases their physiological activity and the quantity of the antibacterial metabolits, that consequently lead to increase of the antagonistic activity of lactobacillus. It is implies that the use of the nanosorbents for the attachment of the probiotical microorganisms are highly perspective for decision the important problems, such as the probiotical preparations delivery to the right address and their attachment to intestines mucosa with the following detoxication of gastro-intestinal tract and the normalization of it’s microecology. Besides that, thus, the received carbonizated nanoparticles have peculiar properties – ability to sorption of LPS toxical shock and, hence, to the detoxication of LPS.
Useful market simulations are key to the evaluation of diferent market designs existing of multiple market mechanisms or rules. Yet a simulation framework which has a comparison of diferent market mechanisms in mind was not found. The need to create an objective view on different sets of market rules while investigating meaningful agent strategies concludes that such a simulation framework is needed to advance the research on this subject. An overview of diferent existing market simulation models is given which also shows the research gap and the missing capabilities of those systems. Finally, a methodology is outlined how a novel market simulation which can answer the research questions can be developed.
Market abstraction of energy markets and policies - application in an agent-based modeling toolbox
(2023)
In light of emerging challenges in energy systems, markets are prone to changing dynamics and market design. Simulation models are commonly used to understand the changing dynamics of future electricity markets. However, existing market models were often created with specific use cases in mind, which limits their flexibility and usability. This can impose challenges for using a single model to compare different market designs. This paper introduces a new method of defining market designs for energy market simulations. The proposed concept makes it easy to incorporate different market designs into electricity market models by using relevant parameters derived from analyzing existing simulation tools, morphological categorization and ontologies. These parameters are then used to derive a market abstraction and integrate it into an agent-based simulation framework, allowing for a unified analysis of diverse market designs. Furthermore, we showcase the usability of integrating new types of long-term contracts and over-the-counter trading. To validate this approach, two case studies are demonstrated: a pay-as-clear market and a pay-as-bid long-term market. These examples demonstrate the capabilities of the proposed framework.
Quartz crystal nanobalance (QCN) sensors are considered as powerful masssensitive sensors to determine materials in the sub-nanogram level. In this study, a single piezoelectric quartz crystal nanobalance modified with polystyrene was employed to detect benzene, toluene, ethylbenzene and xylene (BTEX compounds). The frequency shift of the QCN sensor was found to be linear against the BTEX compound concentrations in the range about 1-45 mg l-1. The correlation coefficients for benzene, toluene, ethylbenzene, and xylene were 0.991, 0.9977, 0.9946 and 0.9971, respectively. The principal component analysis was also utilized to process the frequency response data of the single piezoelectric crystal at different times, considering to the different adsorption-desorption dynamics of BTEX compounds. Using principal component analysis, it was found that over 90% of the data variance could still be explained by use of two principal components (PC1 and PC2). Subsequently, the successful identification of benzene and toluene was possible through the principal component analysis of the transient responses of the polystyrene modified QCN sensor. The results showed that the polystyrene-modified QCN had favorable identification and quantification performances for the BTEX compounds.
Detection of Adrenaline Based on Bioelectrocatalytical System to Support Tumor Diagnostic Technology
(2017)
An H2O2 sensor for the application in industrial sterilisation processes has been developed. Therefore, automated sterilisation equipment at laboratory scale has been constructed using parts from industrial sterilisation facilities. In addition, a software tool has been developed for the control of the sterilisation equipment at laboratory scale. First measurements with the developed sensor set-up as part of the sterilisation equipment have been performed and the sensor has been physically characterised by optical microscopy and SEM.
The absence of a general method for endotoxin removal from liquid interfaces gives an opportunity to find new methods and materials to overcome this gap. Activated nanostructured carbon is a promising material that showed good adsorption properties due to its vast pore network and high surface area. The aim of this study is to find the adsorption rates for a carboneous material produced at different temperatures, as well as to reveal possible differences between the performance of the material for each of the adsorbates used during the study (hemoglobin, serum albumin and lipopolysaccharide, LPS).
In positron emission tomography improving time, energy and spatial detector resolutions and using Compton kinematics introduces the possibility to reconstruct a radioactivity distribution image from scatter coincidences, thereby enhancing image quality. The number of single scattered coincidences alone is in the same order of magnitude as true coincidences. In this work, a compact Compton camera module based on monolithic scintillation material is investigated as a detector ring module. The detector interactions are simulated with Monte Carlo package GATE. The scattering angle inside the tissue is derived from the energy of the scattered photon, which results in a set of possible scattering trajectories or broken line of response. The Compton kinematics collimation reduces the number of solutions. Additionally, the time of flight information helps localize the position of the annihilation. One of the questions of this investigation is related to how the energy, spatial and temporal resolutions help confine the possible annihilation volume. A comparison of currently technically feasible detector resolutions (under laboratory conditions) demonstrates the influence on this annihilation volume and shows that energy and coincidence time resolution have a significant impact. An enhancement of the latter from 400 ps to 100 ps leads to a smaller annihilation volume of around 50%, while a change of the energy resolution in the absorber layer from 12% to 4.5% results in a reduction of 60%. The inclusion of single tissue-scattered data has the potential to increase the sensitivity of a scanner by a factor of 2 to 3 times. The concept can be further optimized and extended for multiple scatter coincidences and subsequently validated by a reconstruction algorithm.
In this paper, methods of sample preparation for potentiometric measurement of phenylalanine are presented. Basing on the spectrophotometric measurements of phenylalanine, the concentrations of reagents of the enzymatic reaction (10 mM L-Phe, 0,4 mM NAD+, 2U L-PheDH) were determined. Then, the absorption spectrum of the reaction product, NADH, was monitored (maximum peak at 340 nm). The results obtained by the spectrophotometric method were compared with the results obtained by the colourimetry, using pH indicators. The above-mentioned two methods will be used as references for potentiometric measurements of phenylalanine concentration.
In this paper, methods of surface modification of different supports, i.e. glass and polymeric beads for enzyme immobilisation are described. The developed method of enzyme immobilisation is based on Schiff’s base formation between the amino groups on the enzyme surface and the aldehyde groups on the chemically modified surface of the supports. The surface of silicon modified by APTS and GOPS with immobilised enzyme was characterised by atomic force microscopy (AFM), time-of-flight secondary ion mass spectroscopy (ToF-SIMS) and infrared spectroscopy (FTIR). The supports with immobilised enzyme (urease) were also tested in combination with microreactors fabricated in silicon and Perspex, operating in a flow-through system. For microreactors filled with urease immobilised on glass beads (Sigma) and on polymeric beads (PAN), a very high and stable signal (pH change) was obtained. The developed method of urease immobilisation can be stated to be very effective.
A new and simple method for nanostructuring using conventional photolithography and layer expansion or pattern-size reduction technique is presented, which can further be applied for the fabrication of different nanostructures and nano-devices. The method is based on the conversion of a photolithographically patterned metal layer to a metal-oxide mask with improved pattern-size resolution using thermal oxidation. With this technique, the pattern size can be scaled down to several nanometer dimensions. The proposed method is experimentally demonstrated by preparing nanostructures with different configurations and layouts, like circles, rectangles, trapezoids, “fluidic-channel”-, “cantilever”- and meander-type structures.
Label-free Electrostatic Detection of DNA Amplification by PCR Using Capacitive Field-effect Devices
(2016)
A capacitive field-effect EIS (electrolyte-insulator-semiconductor) sensor modified with a positively charged weak polyelectrolyte of poly(allylamine hydrochloride) (PAH)/single-stranded probe DNA (ssDNA) bilayer has been used for a label-free electrostatic detection of pathogen-specific DNA amplification via polymerase chain reaction (PCR). The sensor is able to distinguish between positive and negative PCR solutions, to detect the existence of target DNA amplicons in PCR samples and thus, can be used as tool for a quick verification of DNA amplification and the successful PCR process.
Label-free sensing of biomolecules by their intrinsic molecular charge using field-effect devices
(2015)
Functional testing and characterisation of ISFETs on wafer level by means of a micro-droplet cell
(2006)
A wafer-level functionality testing and characterisation system for ISFETs (ionsensitive field-effect transistor) is realised by means of integration of a specifically designed capillary electrochemical micro-droplet cell into a commercial wafer prober-station. The developed system allows the identification and selection of “good” ISFETs at the earliest stage and to avoid expensive bonding, encapsulation and packaging processes for nonfunctioning ISFETs and thus, to decrease costs, which are wasted for bad dies. The developed system is also feasible for wafer-level characterisation of ISFETs in terms of sensitivity, hysteresis and response time. Additionally, the system might be also utilised for wafer-level testing of further electrochemical sensors.
A concept for a sensitive micro total analysis system for high throughput fluorescence imaging
(2006)
This paper discusses possible methods for on-chip fluorescent imaging for integrated bio-sensors. The integration of optical and electro-optical accessories, according to suggested methods, can improve the performance of fluorescence imaging. It can boost the signal to background ratio by a few orders of magnitudes in comparison to conventional discrete setups. The methods that are present in this paper are oriented towards building reproducible arrays for high-throughput micro total analysis systems (µTAS). The first method relates to side illumination of the fluorescent material placed into microcompartments of the lab-on-chip. Its significance is in high utilization of excitation energy for low concentration of fluorescent material. The utilization of a transparent µLED chip, for the second method, allows the placement of the excitation light sources on the same optical axis with emission detector, such that the excitation and emission rays are directed controversly. The third method presents a spatial filtering of the excitation background.
Human induced pluripotent stem cells (hiPSCs) have shown to be promising in disease studies and drug screenings [1]. Cardiomyocytes derived from hiPSCs have been extensively investigated using patch-clamping and optical methods to compare their electromechanical behaviour relative to fully matured adult cells. Mathematical models can be used for translating findings on hiPSCCMs to adult cells [2] or to better understand the mechanisms of various ion channels when a drug is applied [3,4]. Paci et al. (2013) [3] developed the first model of hiPSC-CMs, which they later refined based on new data [3]. The model is based on iCells® (Fujifilm Cellular Dynamics, Inc. (FCDI), Madison WI, USA) but major differences among several cell lines and even within a single cell line have been found and motivate an approach for creating sample-specific models. We have developed an optimisation algorithm that parameterises the conductances (in S/F=Siemens/Farad) of the latest Paci et al. model (2018) [5] using current-voltage data obtained in individual patch-clamp experiments derived from an automated patch clamp system (Patchliner, Nanion Technologies GmbH, Munich).