Article
Refine
Year of publication
Document Type
- Article (1531) (remove)
Has Fulltext
- no (1531) (remove)
Keywords
- LAPS (4)
- CellDrum (3)
- hydrogen peroxide (3)
- Bacillus atrophaeus (2)
- Empirical process (2)
- Field-effect sensor (2)
- Goodness-of-fit test (2)
- Independence test (2)
- Light-addressable potentiometric sensor (2)
- Paired sample (2)
- Parametric bootstrap (2)
- Raman spectroscopy (2)
- Stiffness (2)
- constructive alignment (2)
- damage (2)
- examination (2)
- field-effect sensor (2)
- frequency mixing magnetic detection (2)
- impedance spectroscopy (2)
- likelihood ratio test (2)
- locomotion (2)
- long-term retention (2)
- multimodal (2)
- muscle fascicle behavior (2)
- not identically distributed (2)
- practical learning (2)
- tobacco mosaic virus (TMV) (2)
- ultrasound (2)
- ultrasound imaging (2)
- (Bio)degradation (1)
- Acceleration (1)
- Achilles tendon (1)
- Adaptive control (1)
- Afterload (1)
- Ageing (1)
- AlterG (1)
- Alzheimer's disease (1)
- Anastomotic leakage (1)
- Anatomy (1)
- Annulus Fibrosus (1)
- Architectural gear ratio (1)
- Assistive technology (1)
- Asymptotic efficiency (1)
- Autolysis (1)
- Automatic control (1)
- Bacillus atrophaeus spores (1)
- Bacillus sp (1)
- Balance (1)
- Biocomposites (1)
- Biomechanical simulation (1)
- Biosolubilization (1)
- Booster Station (1)
- Bootstrap (1)
- Bootstrapping (1)
- Brownian Pillow (1)
- CNOT (1)
- Calorimetric gas sensor (1)
- Capacitive field-effect (1)
- Capacitive model (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- Categorial variable (1)
- Cell permeability (1)
- Cellular force (1)
- Cementoblast (1)
- Censored data (1)
- Chemical images (1)
- Chemical imaging sensor (1)
- Chemical sensor (1)
- Circular Dichroism (1)
- Co-managed care (1)
- Collective risk model (1)
- Competitiveness (1)
- Complex System (1)
- Complex-valued eigenvalues (1)
- Compliance (1)
- Compression (1)
- Computational biomechanics (1)
- Concomitant (1)
- Conductive Boundary Condition (1)
- Constitutive model (1)
- Contractile tension (1)
- Contractility (1)
- Coverage probability (1)
- Cramér-von-Mises statistic (1)
- Cramér-von-Mises test (1)
- Cross border adjustment mechanism (1)
- Crámer–von-Mises distance (1)
- C–V method (1)
- DNA biosensor (1)
- DNA hybridization (1)
- DPA (dipicolinic acid) (1)
- Damage mechanics theory (1)
- Decomposition (1)
- Deep Learning (1)
- Dehydrogenase (1)
- Diaphorase (1)
- Disc Degeneration (1)
- Discontinuous fractures (1)
- Discrete Optimization (1)
- Distorsion des oberen Sprunggelenks (1)
- Drug simulation (1)
- E-Mobility (1)
- EIS capacitive sensor (1)
- ES-FEM (1)
- Eigenvalue trajectories (1)
- Elderly (1)
- Electrolyte–insulator–semiconductor (1)
- Electromagnetism (1)
- Electromechanical modeling (1)
- Elektroenzephalographie (1)
- Elemental (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Endothelial dysfunction (1)
- Energy-intensive industry (1)
- Enzymatic biosensor (1)
- Enzyme coverage (1)
- Enzyme logic gate (1)
- Equivalence test (1)
- Esophageal Doppler monitor (1)
- External knee adduction moments (1)
- FS-FEM (1)
- Fall prevention (1)
- Field effect (1)
- Field-effect biosensor (1)
- Finite element analysis (1)
- Finite element modelling (1)
- Floor prices (1)
- Force (1)
- Forces (1)
- Fracture configuration (1)
- Fracture simulation (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Frequency mixing magnetic detection (1)
- Functional Delta Method (1)
- Gamma distribution (1)
- Glaucoma (1)
- Goodness-of-fit tests for uniformity (1)
- Ground-level falls (1)
- Hadamard differentiability (1)
- Haemodialysis (1)
- Handbike (1)
- Heart tissue culture (1)
- Heterostructure (1)
- Hodgkin–Huxley models (1)
- Hoeffding-Blum-Kiefer-Rosenblatt independence test (1)
- Homogenization (1)
- Hotelling’s T² test (1)
- Human-Computer interaction (1)
- Hydrogen peroxide (1)
- Image Reconstruction (1)
- Impedance spectroscopy (1)
- Incomplete data (1)
- Induced pluripotent stem cells (1)
- Inotropic compounds (1)
- Integrated empirical distribution (survival) function (1)
- Interior transmission problem (1)
- Intervertebral Disc (1)
- Intradiscal Pressure (1)
- Inverse Scattering (1)
- Inverse dynamic problem (1)
- Inverse kinematic problem (1)
- Ion channels (1)
- Iterative learning control (1)
- Kinetic energy (1)
- LPS (1)
- Lab-on-Chip (1)
- Label-free detection (1)
- Langevin theory (1)
- Layer-by-layer adsorption (1)
- LbL films (1)
- Light-addressable Potentiometric Sensor (1)
- Lipopolysaccharide (1)
- Liver (1)
- Long COVID (1)
- MOS (1)
- Machine learning (1)
- Magnetic nanoparticles (1)
- Manipulated variables (1)
- Marginal homogeneity test (1)
- Mechanotransduction (1)
- Metascintillator (1)
- Microcirculation (1)
- Micromagnetic simulation (1)
- Mild cognitive impairment (1)
- Mobility (1)
- Mobility tests (1)
- Mobility transition (1)
- Multi-criteria decision analysis (1)
- Multi-sample problem (1)
- Multianalyte detection (1)
- Multiple TOF kernels (1)
- Muscle (1)
- Muscle Fascicle (1)
- Muscle Force (1)
- Musculoskeletal model (1)
- Musculoskeletal system (1)
- Myocardial infarction and cardiac death (1)
- NONOate (1)
- Natural fibres (1)
- Negative impedance convertor (1)
- Neural Network (1)
- Nitric Oxide (1)
- Nitric Oxide Donor (1)
- Non-parallel fissures (1)
- Nonequilibrium dynamics (1)
- Nonlinear Dynamics (1)
- Nucleus Pulposus (1)
- Numerical inversion of Laplace transforms (1)
- Numerical linear algebra (1)
- O2 plasma (1)
- Ocular blood flow (1)
- Organic light-emitting diode display (1)
- Paralympic sport (1)
- Penicillin (1)
- Pharmacology (1)
- Physiology (1)
- Poly(allylamine hydrochloride) (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Polymer-matrix composites (1)
- Post-COVID-19 syndrome (1)
- Preference assessment (1)
- Product-integration (1)
- Proximal humerus fracture (1)
- Psychiatrische Biomarker (1)
- Pulsations (1)
- Pump System (1)
- RVA (1)
- Real-time monitoring (1)
- Recombinant activated protein C (1)
- Regionalization (1)
- Rehabilitation Technology and Prosthetics (1)
- Rehabilitation engineering (1)
- Resampling test (1)
- Resolvent Operator (1)
- Resonance-mode measurement (1)
- Retinal vessel analysis (1)
- Retinal vessels (1)
- Robotic rehabilitation (1)
- Rotator cuff (1)
- Running (1)
- S-FEM (1)
- ScaLAPACK (1)
- Schlafspindeldetektion (1)
- Semi-parametric random censorship model (1)
- Septic cardiomyopathy (1)
- Simulation (1)
- Simultaneous determination (1)
- Sn₃O₄ (1)
- Spleen (1)
- Sprunggelenkorthesen (1)
- Steel industry (1)
- Sterilisation process (1)
- Stress concentrations (1)
- SunRav BookEditor (1)
- Surgical Navigation and Robotics (1)
- Surgical staplers (1)
- Survival analysis (1)
- TMV adsorption (1)
- TOF PET (1)
- Ta₂O₅ gate (1)
- Technical Operations Research (TOR) (1)
- Tendon Rupture (1)
- Tendon properties (1)
- Tension (1)
- Tinetti test (1)
- Transmission Eigenvalues (1)
- Uniaxial compression test (1)
- Vapnik–Čhervonenkis class (1)
- Variable height stapler design (1)
- Vascular response (1)
- Vasomotions (1)
- Velocity (1)
- Visual field asymmetry (1)
- Volterra integral equation (1)
- Volume of confidence regions (1)
- Volume status (1)
- XOR (1)
- achilles tendon (1)
- actin cytoskeleton (1)
- adipose-derived stromal cells (ASCs) (1)
- adsorption (1)
- agility (1)
- allocation (1)
- anaesthetic complications (1)
- anisotropy (1)
- ankle braces (1)
- ankle sprain (1)
- annealing (1)
- aortic perfusion (1)
- artificial olfactory image (1)
- asymptotic relative efficiency (1)
- barium strontium titanate (1)
- biaxial tensile experiment (1)
- biomechanics (1)
- biopotential electrodes (1)
- biosensor (1)
- biosensors (1)
- bootstrap (1)
- calorimetric gas sensor (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- capacitive field-effect sensor (1)
- carbonized rice husk (1)
- cardiomyocyte biomechanics (1)
- catalytic metal (1)
- cell aerosolization (1)
- cell atomization (1)
- central symmetry test (1)
- cerebral small vessel disease (1)
- chance constrained programming (1)
- chemical sensor (1)
- cognitive impairment (1)
- community dwelling (1)
- complete block symmetry (1)
- computational fluid dynamics analysis (1)
- conditional excess distribution (1)
- conditional expectation principle (1)
- confidence interval (1)
- connective tissue (1)
- constitutive modeling (1)
- contactless conductivity sensor (1)
- correlation (1)
- coupled Néel–Brownian relaxation dynamics (1)
- covariance principle (1)
- dental trauma (1)
- dialysis (1)
- difficult airway (1)
- distance learning (1)
- distorted element (1)
- double-lumen tube intubation (1)
- drop jump (1)
- e-books (1)
- e-issues (1)
- eigensolvers (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- electromyography (1)
- electronic nose (1)
- endoluminal (1)
- endospores (1)
- energy absorption (1)
- energy dissipation (1)
- enzymatic (bio)degradation (1)
- enzyme cascade (1)
- exchangeability test (1)
- extracorporeal membrane oxygenation (1)
- fibulare Bandruptur (1)
- field-effect structure (1)
- force generation (1)
- forecast (1)
- forehead EEG (1)
- frequency mixing (1)
- functional data (1)
- gait (1)
- gas sensor (1)
- glucose oxidase (GOx) (1)
- goodness-of-fit test (1)
- healthy aging (1)
- heavy metals (1)
- hiPS cardiomyocytes (1)
- high-intensity exercise (1)
- high-k material (1)
- horseradish peroxidase (HRP) (1)
- huge dimensional data (1)
- humic acid (1)
- hydroxylation (1)
- hyper-gravity (1)
- hyperelastic (1)
- hypo-gravity (1)
- immobilization (1)
- in-ear EEG (1)
- in-situ monitoring (1)
- independence test (1)
- intraclass correlation coefficient (1)
- key performance indicators (1)
- lable-free detection (1)
- light-addressable potentiometric sensor (1)
- light-addressing technologies (1)
- lignite (1)
- limit analysis (1)
- lipopolysaccharide (1)
- magnetic actuation (1)
- magnetic beads (1)
- magnetic biosensing (1)
- magnetic nanoparticles (1)
- magnetic relaxation (1)
- magnetic sandwich immunoassay (1)
- magnetic sensing (1)
- magnetic separation (1)
- magnetic tweezers (1)
- magnetophoretic velocity (1)
- mechanical buffer (1)
- metal-oxide-semiconductor structure (1)
- micromagnetic simulation (1)
- multi-functional material (1)
- multinomial distribution (1)
- multiparametric immunoassays (1)
- multivariate normal distribution (1)
- muscle mechanics (1)
- nanobelts (1)
- non-simplex S-FEM elements (1)
- novel photoexcitation method (1)
- optical sensor setup (1)
- optical spore trapping (1)
- optical trapping (1)
- organosilanes (1)
- overload (1)
- parabolic flight (1)
- performance analysis (1)
- performance testing (1)
- physiology (1)
- plant virus detection (1)
- plug-based microfluidic device (1)
- poly(d, l-lactic acid) (1)
- portfolio risk (1)
- prevention (1)
- psychosocial (1)
- random effects (1)
- random effects meta-regression model (1)
- rehabilitation (1)
- reliability of structures (1)
- retinal microvasculature (1)
- retinal vessels (1)
- running (1)
- rupture of the fibular ligament (1)
- sEMG (1)
- sarcomere operating length (1)
- scanned light pulse technique (1)
- separable Hilbert space (1)
- series elastic element behavior (1)
- shakedown analysis (1)
- shoulder (1)
- silanization (1)
- simulation (1)
- smooth muscle contraction (1)
- softs (1)
- spatial resolution (1)
- sprint start (1)
- standard error of measurement (1)
- sterilisation (1)
- sterilization (1)
- sterilization conditions (1)
- stiffness (1)
- stochastic programming (1)
- strain energy function (1)
- stretch reflex (1)
- stretch-shortening cycle (1)
- superparamagnetic bead (1)
- superparamagnetic nanoparticles (1)
- surface functionalization (1)
- surface modification (1)
- survival (1)
- temperature (1)
- tendon rupture (1)
- test-retest reliability (1)
- tilted constant illumination (1)
- tri-lineage differentiation (1)
- turnip vein clearing virus (TVCV) (1)
- twin-fluid atomizer (1)
- ultrasonography (1)
- uniformly most powerful invariant test (1)
- unloading (1)
- videolaryngoscopy (1)
- virgin passive (1)
- viscoelasticity (1)
- visualization (1)
- walking (1)
- walking gait (1)
- · Psychiatrische Erkrankungen/Diagnostik (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (1531) (remove)
A Classical Reformulation of Finite-Dimensional Quantum Mechanics. Hellwig, K.-E.; Stulpe, W.
(1993)
The readout of gamma detectors is considerably simplified when the event intensity is encoded as a pulse width (Pulse Width Modulation, PWM). Time-to-Digital-Converters (TDC) replace the conventional ADCs and multiple TDCs can be realized easily in one PLD chip (Programmable Logic Device). The output of a PWM stage is only one digital signal per channel which is well suited for transport so that further processing can be performed apart from the detector. This is particularly interesting for large systems with high channel density (e.g. high resolution scanners). In this work we present a circuit with a linear transfer function that requires a minimum of components by performing the PWM already in the preamp stage. This allows a very compact and also cost-efficient implementation of the front-end electronics.
A nonparametric goodness-of-fit test for random variables with values in a separable Hilbert space is investigated. To verify the null hypothesis that the data come from a specific distribution, an integral type test based on a Cramér-von-Mises statistic is suggested. The convergence in distribution of the test statistic under the null hypothesis is proved and the test's consistency is concluded. Moreover, properties under local alternatives are discussed. Applications are given for data of huge but finite dimension and for functional data in infinite dimensional spaces. A general approach enables the treatment of incomplete data. In simulation studies the test competes with alternative proposals.
A Formulation of Quantum Stochastic Processes and Some of its Properties. Hellwig, K.-E.; Stulpe, W.
(1983)
A generalized shear-lag theory for fibres with variable radius is developed to analyse elastic fibre/matrix stress transfer. The theory accounts for the reinforcement of biological composites, such as soft tissue and bone tissue, as well as for the reinforcement of technical composite materials, such as fibre-reinforced polymers (FRP). The original shear-lag theory proposed by Cox in 1952 is generalized for fibres with variable radius and with symmetric and asymmetric ends. Analytical solutions are derived for the distribution of axial and interfacial shear stress in cylindrical and elliptical fibres, as well as conical and paraboloidal fibres with asymmetric ends. Additionally, the distribution of axial and interfacial shear stress for conical and paraboloidal fibres with symmetric ends are numerically predicted. The results are compared with solutions from axisymmetric finite element models. A parameter study is performed, to investigate the suitability of alternative fibre geometries for use in FRP.
On the basis of bivariate data, assumed to be observations of independent copies of a random vector (S,N), we consider testing the hypothesis that the distribution of (S,N) belongs to the parametric class of distributions that arise with the compound Poisson exponential model. Typically, this model is used in stochastic hydrology, with N as the number of raindays, and S as total rainfall amount during a certain time period, or in actuarial science, with N as the number of losses, and S as total loss expenditure during a certain time period. The compound Poisson exponential model is characterized in the way that a specific transform associated with the distribution of (S,N) satisfies a certain differential equation. Mimicking the function part of this equation by substituting the empirical counterparts of the transform we obtain an expression the weighted integral of the square of which is used as test statistic. We deal with two variants of the latter, one of which being invariant under scale transformations of the S-part by fixed positive constants. Critical values are obtained by using a parametric bootstrap procedure. The asymptotic behavior of the tests is discussed. A simulation study demonstrates the performance of the tests in the finite sample case. The procedure is applied to rainfall data and to an actuarial dataset. A multivariate extension is also discussed.
A high-Q resonance-mode measurement of EIS capacitive sensor by elimination of series resistance
(2017)
An EIS capacitive sensor is a semiconductor-based potentiometric sensor, which is sensitive to the ion concentration or pH value of the solution in contact with the sensing surface. To detect a small change in the ion concentration or pH, a small capacitance change must be detected. Recently, a resonance-mode measurement was proposed, in which an inductor was connected to the EIS capacitive sensor and the resonant frequency was correlated with the pH value. In this study, the Q factor of the resonant circuit was enhanced by canceling the internal resistance of the reference electrode and the internal resistance of the inductor coil with the help of a bypass capacitor and a negative impedance converter, respectively. 1% variation of the signal in the developed system corresponded to a pH change of 3.93 mpH, which was about 1/12 of the conventional method, suggesting a better performance in detection of a small pH change.
Monitoring the cellular metabolism of bacteria in (bio)fermentation processes is crucial to control and steer them, and to prevent undesired disturbances linked to metabolically inactive microorganisms. In this context, cell-based biosensors can play an important role to improve the quality and increase the yield of such processes. This work describes the simultaneous analysis of the metabolic behavior of three different types of bacteria by means of a differential light-addressable potentiometric sensor (LAPS) set-up. The study includes Lactobacillus brevis, Corynebacterium glutamicum, and Escherichia coli, which are often applied in fermentation processes in bioreactors. Differential measurements were carried out to compensate undesirable influences such as sensor signal drift, and pH value variation during the measurements. Furthermore, calibration curves of the cellular metabolism were established as a function of the glucose concentration or cell number variation with all three model microorganisms. In this context, simultaneous (bio)sensing with the multi-organism LAPS-based set-up can open new possibilities for a cost-effective, rapid detection of the extracellular acidification of bacteria on a single sensor chip. It can be applied to evaluate the metabolic response of bacteria populations in a (bio)fermentation process, for instance, in the biogas fermentation process.
Results are presented on the ratios of the nucleon structure function in copper to deuterium from two separate experiments. The data confirm that the nucleon structure function,F 2, is different for bound nucleons than for the quasi-free ones in the deuteron. The redistribution in the fraction of the nucleon's momentum carried by quarks is investigated and it is found that the data are compatible with no integral loss of quark momenta due to nuclear effects.
The spin asymmetry in deep inelastic scattering of longitudinally polarised muons by longitudinally polarised protons has been measured over a large x range (0.01<x<0.7). The spin-dependent structure function g1(x) for the proton has been determined and its integral over x found to be 0.114±0.012±0.026, in disagreement with the Ellis-Jaffe sum rule. Assuming the validity of the Bjorken sum rule, this result implies a significant negative value for the integral of g1 for the neutron. These values for the integrals of g1 lead to the conclusion that the total quark spin constitutes a rather small fraction of the spin of the nucleon.
A microscopic photometric method for measuring erythrocyte deformability. Artmann, Gerhard Michael
(1986)
Purpose
Two semi-empirical models were recently published, both making use of existing literature data, but each taking into account different physical phenomena that trigger hemolysis. In the first model, hemoglobin (Hb) release is described as a permeation procedure across the membrane, assuming a shear stress-dependent process (sublethal model). The second model only accounts for hemoglobin release that is caused by cell membrane breakdown, which occurs when red blood cells (RBC) undergo mechanically induced shearing for a period longer than the threshold time (nonuniform threshold model). In this paper, we introduce a model that considers the hemolysis generated by both these possible phenomena.
Methods
Since hemolysis can possibly be caused by permeation of hemoglobin through the RBC functional membrane as well as by release of hemoglobin from RBC membrane breakdown, our proposed model combines both these models. An experimental setup consisting of a Couette device was utilized for validation of our proposed model.
Results
A comparison is presented between the damage index (DI) predicted by the proposed model vs. the sublethal model vs. the nonthreshold model and experimental datasets. This comparison covers a wide range of shear stress for both human and porcine blood. An appropriate agreement between the measured DI and the DI predicted by the present model was obtained.
Conclusions
The semiempirical hemolysis model introduced in this paper aims for significantly enhanced conformity with experimental data. Two phenomenological outcomes become possible with the proposed approach: an estimation of the average time after which cell membrane breakdown occurs under the applied conditions, and a prediction of the ratio between the phenomena involved in hemolysis.
A new in vitro tool to investigate cardiac contractility under physiological mechanical conditions
(2019)
Advances in polymer science have significantly increased polymer applications in life sciences. We report the use of free-standing, ultra-thin polydimethylsiloxane (PDMS) membranes, called CellDrum, as cell culture substrates for an in vitro wound model. Dermal fibroblast monolayers from 28- and 88-year-old donors were cultured on CellDrums. By using stainless steel balls, circular cell-free areas were created in the cell layer (wounding). Sinusoidal strain of 1 Hz, 5% strain, was applied to membranes for 30 min in 4 sessions. The gap circumference and closure rate of un-stretched samples (controls) and stretched samples were monitored over 4 days to investigate the effects of donor age and mechanical strain on wound closure. A significant decrease in gap circumference and an increase in gap closure rate were observed in trained samples from younger donors and control samples from older donors. In contrast, a significant decrease in gap closure rate and an increase in wound circumference were observed in the trained samples from older donors. Through these results, we propose the model of a cell monolayer on stretchable CellDrums as a practical tool for wound healing research. The combination of biomechanical cell loading in conjunction with analyses such as gene/protein expression seems promising beyond the scope published here.
A novel scheme for precise diagnostics and effective stabilization of currents in a fuel cell stack
(2010)
Within the developments for the Crystal Clear small animal PET project (CLEARPET) a dual head PET system has been established. The basic principle is the early digitization of the detector pulses by free running ADCs. The determination of the γ-energy and also the coincidence detection is performed by data processing of the sampled pulses on the host computer. Therefore a time mark is attached to each pulse identifying the current cycle of the 40 MHz sampling clock. In order to refine the time resolution the pulse starting time is interpolated from the samples of the pulse rise. The detector heads consist of multichannel PMTs with a single LSO scintillator crystal coupled to each channel. For each PMT only one ADC is required. The position of an event is obtained separately from trigger signals generated for each single channel. An FPGA is utilized for pulse buffering, generation of the time mark and for the data transfer to the host via a fast I/O-interface.
A small PET system has been built up with two multichannel photomultipliers, which are attached to a matrix of 64 single LSO crystals each. The signal from each multiplier is being sampled continuously by a 12 bit ADC at a sampling frequency of 40 MHz. In case of a scintillation pulse a subsequent FPGA sends the corresponding set of samples together with the channel information and a time mark to the host computer. The data transfer is performed with a rate of 20 MB/s. On the host all necessary information is extracted from the data. The pulse energy is determined, coincident events are detected and multiple hits within one matrix can be identified. In order to achieve a narrow time window the pulse starting time is refined further than the resolution of the time mark (=25 ns) would allow. This is possible by interpolating between the pulse samples. First data obtained from this system will be presented. The system is part of developments for a much larger system and has been created to study the feasibility and performance of the technique and the hardware architecture.
To prevent the reduction of muscle mass and loss of strength coming along with the human aging process, regular training with e.g. a leg press is suitable. However, the risk of training-induced injuries requires the continuous monitoring and controlling of the forces applied to the musculoskeletal system as well as the velocity along the motion trajectory and the range of motion. In this paper, an adaptive norm-optimal iterative learning control algorithm to minimize the knee joint loadings during the leg extension training with an industrial robot is proposed. The response of the algorithm is tested in simulation for patients with varus, normal and valgus alignment of the knee and compared to the results of a higher-order iterative learning control algorithm, a robust iterative learning control and a recently proposed conventional norm-optimal iterative learning control algorithm. Although significant improvements in performance are made compared to the conventional norm-optimal iterative learning control algorithm with a small learning factor, for the developed approach as well as the robust iterative learning control algorithm small steady state errors occur.
The esophageal Doppler monitor (EDM) is a minimally-invasive hemodynamic device which evaluates both cardiac output (CO), and fluid status, by estimating stroke volume (SV) and calculating heart rate (HR). The measurement of these parameters is based upon a continuous and accurate approximation of distal thoracic aortic blood flow. Furthermore, the peak velocity (PV) and mean acceleration (MA), of aortic blood flow at this anatomic location, are also determined by the EDM. The purpose of this preliminary report is to examine additional clinical hemodynamic calculations of: compliance (C), kinetic energy (KE), force (F), and afterload (TSVRi). These data were derived using both velocity-based measurements, provided by the EDM, as well as other contemporaneous physiologic parameters. Data were obtained from anesthetized patients undergoing surgery or who were in a critical care unit. A graphical inspection of these measurements is presented and discussed with respect to each patient’s clinical situation. When normalized to each of their initial values, F and KE both consistently demonstrated more discriminative power than either PV or MA. The EDM offers additional applications for hemodynamic monitoring. Further research regarding the accuracy, utility, and limitations of these parameters is therefore indicated.
Neuromuscular strength training of the leg extensor muscles plays an important role in the rehabilitation and prevention of age and wealth related diseases. In this paper, we focus on the design and implementation of a Cartesian admittance control scheme for isotonic training, i.e. leg extension and flexion against a predefined weight. For preliminary testing and validation of the designed algorithm an experimental research and development platform consisting of an
industrial robot and a force plate mounted at its end-effector has been used. Linear, diagonal and arbitrary two-dimensional motion trajectories with different weights for the leg extension and flexion part are applied. The proposed algorithm is easily adaptable to trajectories consisting of arbitrary six-dimensional poses and allows the implementation of individualized trajectories.
The scope of this study is the measurement of endotoxin adsorption rate for carbonized rice husk. It showed good adsorption properties for LPS. During the batch experiments, several techniques were used and optimized for improving the material’s adsorption behavior. Also, with the results obtained it was possible to differentiate the materials according to their adsorption capacity and kinetic characteristics.
Wearable EEG has gained popularity in recent years driven by promising uses outside of clinics and research. The ubiquitous application of continuous EEG requires unobtrusive form-factors that are easily acceptable by the end-users. In this progression, wearable EEG systems have been moving from full scalp to forehead and recently to the ear. The aim of this study is to demonstrate that emerging ear-EEG provides similar impedance and signal properties as established forehead EEG. EEG data using eyes-open and closed alpha paradigm were acquired from ten healthy subjects using generic earpieces fitted with three custom-made electrodes and a forehead electrode (at Fpx) after impedance analysis. Inter-subject variability in in-ear electrode impedance ranged from 20 kΩ to 25 kΩ at 10 Hz. Signal quality was comparable with an SNR of 6 for in-ear and 8 for forehead electrodes. Alpha attenuation was significant during the eyes-open condition in all in-ear electrodes, and it followed the structure of power spectral density plots of forehead electrodes, with the Pearson correlation coefficient of 0.92 between in-ear locations ELE (Left Ear Superior) and ERE (Right Ear Superior) and forehead locations, Fp1 and Fp2, respectively. The results indicate that in-ear EEG is an unobtrusive alternative in terms of impedance, signal properties and information content to established forehead EEG.
The necessity of e-books as a primary of learning, its opportunities for realization of competence during training biologist and biotechnologist specialists are determined. Definitions and requirements to the e-books, its advantages in comparison with traditional textbooks, and the ways of creation of e-books in the SunRav BookEditor program are considered.
Aggregatelager
(1990)
Exercise training effectively mitigates aging-induced health and fitness impairments. Traditional training recommendations for the elderly focus separately on relevant physiological fitness domains, such as balance, flexibility, strength and endurance. Thus, a more holistic and functional training framework is needed. The proposed agility training concept integratively tackles spatial orientation, stop and go, balance and strength. The presented protocol aims at introducing a two-armed, one-year randomized controlled trial, evaluating the effects of this concept on neuromuscular, cardiovascular, cognitive and psychosocial health outcomes in healthy older adults. Eighty-five participants were enrolled in this ongoing trial. Seventy-nine participants completed baseline testing and were block-randomized to the agility training group or the inactive control group. All participants undergo pre- and post-testing with interim assessment after six months. The intervention group currently receives supervised, group-based agility training twice a week over one year, with progressively demanding perceptual, cognitive and physical exercises. Knee extension strength, reactive balance, dual task gait speed and the Agility Challenge for the Elderly (ACE) serve as primary endpoints and neuromuscular, cognitive, cardiovascular, and psychosocial meassures serve as surrogate secondary outcomes. Our protocol promotes a comprehensive exercise training concept for older adults, that might facilitate stakeholders in health and exercise to stimulate relevant health outcomes without relying on excessively time-consuming physical activity recommendations.
Air-pulse corneal applanation signal curve parameters for the characterisation of keratoconus
(2011)
We consider time-dependent portfolios and discuss the allocation of changes in the risk of a portfolio to changes in the portfolio’s components. For this purpose we adopt established allocation principles. We also use our approach to obtain forecasts for changes in the risk of the portfolio’s components. To put the approach into practice we present an implementation based on the output of a simulation. Allocation is illustrated with an example portfolio in the context of Solvency II. The quality of the forecasts is investigated with an empirical study.
Altered gastrocnemius contractile behavior in former achilles tendon rupture patients during walking
(2022)
Achilles tendon rupture (ATR) remains associated with functional limitations years after injury. Architectural remodeling of the gastrocnemius medialis (GM) muscle is typically observed in the affected leg and may compensate force deficits caused by a longer tendon. Yet patients seem to retain functional limitations during—low-force—walking gait. To explore the potential limits imposed by the remodeled GM muscle-tendon unit (MTU) on walking gait, we examined the contractile behavior of muscle fascicles during the stance phase. In a cross-sectional design, we studied nine former patients (males; age: 45 ± 9 years; height: 180 ± 7 cm; weight: 83 ± 6 kg) with a history of complete unilateral ATR, approximately 4 years post-surgery. Using ultrasonography, GM tendon morphology, muscle architecture at rest, and fascicular behavior were assessed during walking at 1.5 m⋅s–1 on a treadmill. Walking patterns were recorded with a motion capture system. The unaffected leg served as control. Lower limbs kinematics were largely similar between legs during walking. Typical features of ATR-related MTU remodeling were observed during the stance sub-phases corresponding to series elastic element (SEE) lengthening (energy storage) and SEE shortening (energy release), with shorter GM fascicles (36 and 36%, respectively) and greater pennation angles (8° and 12°, respectively). However, relative to the optimal fascicle length for force production, fascicles operated at comparable length in both legs. Similarly, when expressed relative to optimal fascicle length, fascicle contraction velocity was not different between sides, except at the time-point of peak series elastic element (SEE) length, where it was 39 ± 49% lower in the affected leg. Concomitantly, fascicles rotation during contraction was greater in the affected leg during the whole stance-phase, and architectural gear ratios (AGR) was larger during SEE lengthening. Under the present testing conditions, former ATR patients had recovered a relatively symmetrical walking gait pattern. Differences in seen AGR seem to accommodate the profound changes in MTU architecture, limiting the required fascicle shortening velocity. Overall, the contractile behavior of the GM fascicles does not restrict length- or velocity-dependent force potentials during this locomotor task.
Altered neurovascular coupling as measured by optical imaging: a biomarker for Alzheimer’s disease
(2017)
Retinal vessels are similar to cerebral vessels in their structure and function. Moderately low oscillation frequencies of around 0.1 Hz have been reported as the driving force for paravascular drainage in gray matter in mice and are known as the frequencies of lymphatic vessels in humans. We aimed to elucidate whether retinal vessel oscillations are altered in Alzheimer's disease (AD) at the stage of dementia or mild cognitive impairment (MCI). Seventeen patients with mild-to-moderate dementia due to AD (ADD); 23 patients with MCI due to AD, and 18 cognitively healthy controls (HC) were examined using Dynamic Retinal Vessel Analyzer. Oscillatory temporal changes of retinal vessel diameters were evaluated using mathematical signal analysis. Especially at moderately low frequencies around 0.1 Hz, arterial oscillations in ADD and MCI significantly prevailed over HC oscillations and correlated with disease severity. The pronounced retinal arterial vasomotion at moderately low frequencies in the ADD and MCI groups would be compatible with the view of a compensatory upregulation of paravascular drainage in AD and strengthen the amyloid clearance hypothesis.